Study at a glance
Can different laboratory tests change how vitamin D results are understood?
Researchers examined whether different laboratory tests change how vitamin D results are understood. They studied blood samples and population surveys. The measurement was total 25-hydroxyvitamin D, the usual vitamin D blood marker. The page also considers real differences between groups of people.
Does a consistent vitamin D test result always mean an accurate result?
In one comparison, 13 tests measured blood samples from 50 donors. All tests gave sufficiently consistent repeated results, but only nine met the study’s accuracy limit. Across the same samples, average results ranged from 69.0 to 93.3 nmol/L. The reference average was 77.1 nmol/L. A test could therefore give consistent results while still reading too high or too low.
Can different tests put the same vitamin D sample above or below a cut-off?
Different tests can place the same person above or below a chosen blood-level cut-off. In an Irish survey, using a shared measurement standard changed the estimated percentage below 30 nmol/L from 6.5% to about 11%. This was a change in measurement, not a new change in the people studied.
Does using shared standards remove every difference in vitamin D results?
Shared standards improve comparisons, but people also differ because of season, sunlight, body size and other factors. A range found in one population is not automatically a personal target. These findings do not mean all vitamin D tests are unreliable. They also do not show that every difference between results comes from a laboratory error.
Read the full article below ↓Vitamin D blood-test results are influenced not only by the person’s biology but also by the measurement system and the population against which the result is interpreted. Studies comparing assays and national survey data show that differences in calibration and analytical bias can change both individual classifications and estimates of how common low vitamin D status is.
What question did this evidence investigate?
The evidence asks how much assay choice, laboratory performance, standardisation and population variation can influence interpretation of serum 25-hydroxyvitamin D, or 25(OH)D.
How much can assays differ?
In a Vitamin D Standardization Program comparison, 13 assays were tested against reference measurement values using 50 individual-donor serum samples. All assays met the study’s overall precision criterion, but only nine met its mean-bias criterion.
Across the same donor samples, mean measured total 25(OH)D ranged from 69.0 to 93.3 nmol/L between assays, compared with a NIST reference mean of 77.1 nmol/L. Some immunoassays also responded differently when samples contained relatively high concentrations of 25(OH)D2.
This demonstrates why repeatability and accuracy are not the same thing. An assay can produce consistent results while remaining systematically above or below a reference value.
Can assay differences change classification?
Yes. Earlier laboratory comparisons found that clinically similar samples could produce markedly different concentrations in different laboratories. In one experiment, mean 25(OH)D across six laboratories ranged from 17.1 to 35.6 ng/mL for samples drawn from the same group of healthy adults.
When results sit near a threshold, this degree of variation can change whether a person is classified above or below it.
Why does this matter in population research?
Measurement bias can alter estimates for an entire country or cohort. In an Irish national survey, the estimated prevalence below 30 nmol/L changed from 6.5 percent using the original ELISA measurements to approximately 11 percent after VDSP standardisation or LC-MS/MS reanalysis.
British cohort research likewise showed substantial average differences between commercial assays. Standardisation and harmonisation are therefore necessary when researchers compare vitamin D distributions across studies, laboratories or time periods.
What is population-level variation?
Not all population variation is measurement error. Different populations genuinely have different 25(OH)D distributions because of season, geography, sunlight exposure, body size, age, diet, supplementation and other factors.
Biological-variation research has also shown that between-person variation can be much larger than within-person variation. This limits the amount of information that a broad population reference interval can provide about change within one individual.
This is why Population Reference Ranges Explained should be read as population context rather than as a universal personal target.
Does LC-MS/MS solve the problem?
LC-MS/MS has important advantages, including separate measurement of 25(OH)D2 and 25(OH)D3. But the method is not automatically accurate simply because mass spectrometry is used. Calibration, traceability, extraction, chromatography and laboratory performance still matter.
The important distinction is therefore between measurements with demonstrated standardisation and performance and measurements for which those properties have not been established.
What does this evidence support?
It supports interpreting vitamin D results with knowledge of the assay and laboratory context, particularly when comparing results generated by different methods or applying numerical thresholds. Standardisation improves comparability and reduces the risk that measurement bias will masquerade as biological difference.
It also supports distinguishing assay noise from genuine population heterogeneity. Both affect interpretation, but they are different scientific problems.
What does this evidence not establish?
It does not show that vitamin D testing is inherently unreliable. Modern assays can perform well. It does not show that every difference between two results is caused by the laboratory. It does not establish one universal reference range or prove that a population interval is equivalent to an optimal individual target.
Why this matters within vitamin D testing
A numerical 25(OH)D result acquires meaning from both the person and the measurement system. Biological context determines what concentration is present. Analytical performance determines how faithfully that concentration is reported. Population context influences how the reported number is classified. Keeping those levels separate is essential for responsible interpretation.
The broader measurement problem is explored in Variability in Vitamin D Measurements. For the full methods, numerical results, standardisation evidence and limitations, see the paired Analytical and Population-Level Noise in Vitamin D Test Interpretation: Full Study.
Primary sources and publication details
Wise SA, Camara JE, Sempos CT, et al. Vitamin D Standardization Program (VDSP) intralaboratory study for the assessment of 25-hydroxyvitamin D assay variability and bias. Journal of Steroid Biochemistry and Molecular Biology. 2021;212:105917. Read the full study.
Hyppönen E, Turner S, Cumberland P, Power C, Gibb I. Serum 25-hydroxyvitamin D measurement in a large population survey with statistical harmonization of assay variation to an international standard. Journal of Clinical Endocrinology and Metabolism. 2007;92(12):4615-4622. Read the study record.
Cashman KD, Kiely M, Kinsella M, et al. Evaluation of Vitamin D Standardization Program protocols for standardizing serum 25-hydroxyvitamin D data. American Journal of Clinical Nutrition. 2013. Read the full study.
Viljoen A, Singh DK, Farrington K, Twomey PJ. Analytical quality goals for 25-vitamin D based on biological variation. Journal of Clinical Laboratory Analysis. 2011;25(2):130-133. Read the full study.
Related reading
Knowledge of vitamin D and perceptions and attitudes toward sunlight among Chinese middle-aged and elderly women: a population survey in Hong Kong
Physical and biological risk factors for vitamin D inadequacy are known; however, cultural: and population-specific behaviours and attitudes that influence these risk factors, particularly among Asian people, are less well documented.
Original paper ↗Read more →Association between daily sunlight exposure duration and diabetic retinopathy in Korean adults with diabetes: A nationwide population-based cross-sectional study
To investigate the association between daily sunlight exposure duration and diabetic retinopathy in Korean adults with diabetes.
Original paper ↗Read more →Development and validation of sunlight exposure measurement questionnaire (SEM-Q) for use in adult population residing in Pakistan
Hence, the aim of this study was to develop and validate questionnaires to assess sunlight exposure in healthy individuals residing in Karachi, Pakistan.
Original paper ↗Read more →Is Sunlight Exposure Enough to Avoid Wintertime Vitamin D Deficiency in United Kingdom Population Groups?
Our objectives are to examine the sun exposure behaviours of different United Kingdom sectors and to identify if their exposure is enough to maintain winter circulating 25-hydroxyvitamin D above deficiency (>25 nmol/L).
Original paper ↗Read more →A 6-month “self-monitoring” lifestyle modification with increased sunlight exposure modestly improves vitamin D status, lipid profile and glycemic status in overweight and obese Saudi adults with varying glycemic levels
The over-all age-adjusted prevalence of diabetes mellitus type 2 (DMT2) in Saudi Arabia is unprecedented at 31%.
Original paper ↗Read more →Association between sunlight exposure and risk of rheumatic diseases: a prospective cohort study in the UK
Data were derived from the UK Biobank (a nationwide prospective cohort in the United Kingdom), including 363,873 participants followed up from 2006 to 2022.
Original paper ↗Read more →Can the supplementation of vitamin D, sun exposure, and isolation during the COVID-19 pandemic affect the seasonal concentration of 25(OH)D and selected blood parameters among young soccer players in a one-year training season?
Forty elite young soccer players (age: 17.2 ± 1.16 years, body mass: 70.2 ± 5.84, and body height: 179.1 ± 4.26 cm) participated in the research.
Original paper ↗Read more →Changes of 25(OH)D Concentration, Bone Resorption Markers and Physical Performance as an Effect of Sun Exposure, Supplementation of Vitamin D and Lockdown among Young Soccer Players during a One-Year Training Season
The main purpose of this research was to demonstrate the changes in 25(OH)D concentration, bone resorption markers, and physical fitness along the one-year training season in young soccer players.
Original paper ↗Read more →Effectiveness of Educational Practices in University Students’ Knowledge about Sun Protection and Its Relation to Sunlight Exposure: An Exploratory Study in a Portuguese Higher Education Institution
Nowadays, there is worldwide recognition that health and educational outcomes are inextricably linked.
Original paper ↗Read more →Influence of Sunlight and Oral D3 Supplementation on Serum 25(OH)D Concentration and Exercise Performance in Elite Soccer Players
The aim of this study was to evaluate the influence of natural sun exposure and six weeks of a high dose of vitamin D supplementation on vitamin D, testosterone and cortisol serum concentrations as well as speed, power and VO2max in professional soccer players.
Original paper ↗Read more →Latitude, sun exposure and vitamin D supplementation: associations with quality of life and disease outcomes in a large international cohort of people with multiple sclerosis
Of 2301 participants, 82.3 % were female, median age was 45 years (IQR 38 to 53 years), with a median time since diagnosis of 6 years (IQR 3-12 years), the majority (61.6 %) having relapsing-remitting MS.
Original paper ↗Read more →Poor Status of Vitamin D: A Survey of Area With Lowest Sunlight Radiation in Sichuan, China
This study aimed to assess serum 25-hydroxyvitamin D [25(OH)D] levels among adult women in Sichuan basin with the lowest sunlight radiation in China, and the associations with sunlight exposure and age.
Original paper ↗Read more →Positive Association between Blood 25-Hydroxyvitamin D Levels and Pterygium after Control for Sunlight Exposure
A total of 19,178 participants aged ≥ 30 years were evaluated for blood 25-hydroxyvitamin D levels and performed ophthalmic slit lamp examinations.
Original paper ↗Read more →Sunlight, dietary habits, genetic polymorphisms and vitamin D deficiency in urban and rural infants of Bangladesh
We conducted an observational study to assess the prevalence and risk factors of vitamin D deficiency in 12 to 24 months old children living in urban and rural Bangladesh.
Original paper ↗Read more →Sunlight exposed body surface area is associated with serum 25-hydroxyvitamin D (25(OH)D) level in pregnant Minangkabau women, Indonesia
This study was aimed to elucidate the association of sunlight exposed body surface area with serum 25(OH)D in pregnant Minangkabau women of Indonesia.
Original paper ↗Read more →Ultraviolet B Light Emitting Diodes (LEDs) Are More Efficient and Effective in Producing Vitamin D3 in Human Skin Compared to Natural Sunlight
Vitamin D, the sunshine vitamin is important for health.
Original paper ↗Read more →Vitamin D and Sunlight Exposure in Newly-Diagnosed Parkinson’s Disease
Therefore, we evaluated the associations between serum vitamin D, vitamin D intake, sunlight exposure, and newly-diagnosed PD patients in a Chinese population.
Original paper ↗Read more →Analytical and Population-Level Noise in Vitamin D Test Interpretation: Full Study
Review how assay bias, laboratory methods, standardisation and population differences can influence vitamin D test results and their interpretation.
Read more →Lack of significant seasonal association between serum 25(OH)D concentration, muscle mass and strength in postmenopausal women from the D-FINES longitudinal study
The aim of the present study was to assess the seasonal relationship between serum 25(OH)D concentration, lean mass and muscle strength.
Original paper ↗Read more →Low dose ultraviolet B irradiation at 308 nm with light-emitting diode device effectively increases serum levels of 25(OH)D
This animal study aimed to elucidate the relationship of low-dose, narrow-band UVB at 308 nm with vitamin D synthesis.
Original paper ↗Read more →Seasonal variation of 25-Hydroxyvitamin D and indices of carbohydrate and lipid metabolism in postmenopausal women
Therefore, the purpose of this study was to evaluate the level of carbohydrate and lipid metabolism indices in relation to seasonal changes in 25-hydroxyvitamin D (25(OH)D) concentration in postmenopausal women.
Original paper ↗Read more →Original sources
Read the full study
Wise SA, Camara JE, Sempos CT, et al.
Publication details
Wise SA, Camara JE, Sempos CT, et al. Vitamin D Standardization Program (VDSP) intralaboratory study for the assessment of 25-hydroxyvitamin D assay variability and bias. Journal of Steroid Biochemistry and Molecular Biology. 2021;212:105917. Read the full study.
Read the study record
Hyppönen E, Turner S, Cumberland P, Power C, Gibb I.
Publication details
Hyppönen E, Turner S, Cumberland P, Power C, Gibb I. Serum 25-hydroxyvitamin D measurement in a large population survey with statistical harmonization of assay variation to an international standard. Journal of Clinical Endocrinology and Metabolism. 2007;92(12):4615-4622. Read the study record.
Read the full study
Cashman KD, Kiely M, Kinsella M, et al.
Publication details
Cashman KD, Kiely M, Kinsella M, et al. Evaluation of Vitamin D Standardization Program protocols for standardizing serum 25-hydroxyvitamin D data. American Journal of Clinical Nutrition. 2013. Read the full study.
Read the full study
Viljoen A, Singh DK, Farrington K, Twomey PJ.
Publication details
Viljoen A, Singh DK, Farrington K, Twomey PJ. Analytical quality goals for 25-vitamin D based on biological variation. Journal of Clinical Laboratory Analysis. 2011;25(2):130-133. Read the full study.