Vitamin D3 for Life. Live Enlightened.

Research libraryVitamin D3 For Life
Study design and methods

Primary relevance to vitamin D Vitamin D is a stated subject of this paper.

Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.

Why this paper is included

Supporting source evidence:

10 years of 25-hydroxyvitamin-D testing by LC-MS/MS-trends in vitamin-D deficiency and sufficiency

Source: Article title. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Study design awaiting verification.

Study design awaiting verification

The available source does not establish a sufficiently clear study design.

Meta-analysis unclear · Blinding unclear / not reported · Research setting awaiting verification

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Full studies

10 years of 25-hydroxyvitamin-D testing by LC-MS/MS-trends in vitamin-D deficiency and sufficiency

Study design awaiting verification · Bone Reports · 2018

Original publication title

10 years of 25-hydroxyvitamin-D testing by LC-MS/MS-trends in vitamin-D deficiency and sufficiency

Kornelia Galior; Hemamalini Ketha; Stefan Grebe; Ravinder J Singh

© 2018 The Authors

Original publication · Publisher record · CC BY 4.0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

At a glance

Study background

What background does the paper provide?

Vitamin-D and parathyroid hormone (PTH) are the principle regulators of calcium homeostasis in all tetrapods and play an important role in bone metabolism (Lips and van Schoor, 2011; Pettifor and Prentice, 2011; Rizzoli, 2014). Vitamin-D exists in two major forms, vitamin-D2 (ergocalciferol) and vitamin-D3 (cholecalciferol). Both are formed by UV irradiation of either 7-dehydroergosterol (phytoplankton, fungi and yeast) or 7-dehydrocholesterol (all vertebrates with the exception of fish [predominately dietary-derived vitamin-D2]). The two forms differ only in the substitution on the side chain.

It is believed that vitamin-D2 first emerged in phytoplankton about 750 million years ago and served as the vitamin-D source for marine vertebrates until the transition to terrestrial life occurred and vitamin-D3 production commenced in the skin of tetrapods (Holick, 2008a).

In modern humans, primary sources of vitamin-D include diet or supplements (vitamin-D2 and/or-D3) and vitamin-D3 derived from 7-dehydrocholesterol in the skin after exposure to UV light (Fig. 1) (Holick, 2008b; Singh, 1985). Endogenous or dietary vitamin-D binds to vitamin-D binding protein and is transported to the liver, where it is hydroxylated at the carbon 25-position, creating 25-hydroxyvitamin-D (25(OH)D). 25(OH)D is the most abundant circulating form of the vitamin-D. Vitamin-D and 25(OH)D have no established bioactivity and can be viewed as pro-hormones.

Fig. 1

The vitamin-D metabolic pathway.

Fig. 1Figure image at the original source — open the original paper. This file is not included in this text import.

25-hydroxyvitamin-D-1α-hydroxylase (CYP27B1) in the kidneys converts 25(OH)D to the active hormone, 1,25-(OH)2D (Figure 1). 1,25-(OH)2D belongs to the superfamily of thyroid- and steroid hormones, and exerts its effects through changes in gene transcription. It binds to a nuclear receptor (Vitamin-D receptor, VDR) that dimerizes with the retinoid X receptor (RxR) before binding to gene regulatory DNA elements. There are between 2000 and 8000 VDR response elements in the human genome. Transcriptional response depends on the number of available VDR and RxR, the concentrations of their respective ligands, the nature of the response element (enhancing or inhibiting), availability of co-factors and transcriptional accessibility of the respective genes (Pike, 2016).

Consequently, the actions of 1,25-(OH)2D across various tissues of an entire animal are complex and in most cases require detailed study to detect clinically relevant changes. The areas that are exceptions to this rule are calcium and phosphate metabolism and bone metabolism. 1,25-(OH)2D obvious principle role is (i) to increase intestinal calcium absorption, (ii) to increase calcium and phosphate reabsorption in the kidneys, (iii) to increase calcium release from bones in concert with PTH, and (iv) to downregulate PTH production.

The activity of the CYP27B1 in turn is regulated by PTH and other factors including calcium demand.

Due to these feedback mechanism, production of 1,25(OH)2D remains constant over a wide range of serum 25(OH)D concentrations, with excess 25(OH)D and 1,25(OH)2D being converted to inactive metabolites, 24,25(OH)2D and 1,24,25(OH)3D by 25-hydroxyvitaminD-24-hydroxylase (CYP24A1). Additional, independent inactivation is catalyzed by 3-epimerase, which isomerizes the C-3 OH group of 25(OH)D and 1,25(OH)2D from the α to β orientation, reducing bioactivity (Bikle, 2014).

Source: Background Source: Background Source: Background Source: Background Source: Background

Case histories

1.1

Vitamin-D toxicity due to intentional vitamin-D overdose

In 2015, we reported a pediatric case of vitamin-D intoxication with vitamin-D3 supplements (Ketha et al., 2015). Briefly, four-month-old infant was admitted to Mayo Clinic for significant dehydration, lethargy, and weight loss. Routine chemistry blood panel revealed total calcium levels of 18.7 mg/dL indicating severe hypercalcemia. PTH levels were suppressed (<6 pg/mL; normal range: 15–65 pg/mL) and serum phosphorous was 1.9 mg/dL; normal range: 2.5–4.5 mg/dL. Further medical evaluation revealed hypercalciuria and nephrocalcinosis. During the discussion with the mother it was discovered, that in the last two months the infant was receiving daily dosage of oral vitamin-D3 supplementation that was greater than the manufacturer's recommendation.

It was estimated that the baby was receiving ~50,000 IU of vitamin-D per day while recommended dose on the label was 2,000 IU. It was also determined that the actual amount of vitamin-D per drop was 6,000 IU, 3 fold higher than what it was stated on the label (2,000 IU). Vitamin-D metabolites were tested in the infant's blood and were as follows: 25(OH)D3, 293 ng/mL (optimal range of total 25(OH)D:20–50 ng/mL); 1,25(OH)2D3, 138–111 pg/mL (optimal range: 24–86 pg/mL); ratio of 24,25(OH)2D3 to 25(OH)D3 was 0.11–0.14 (normal range: 0.07–0.18) and suggesting normal Cyp24A1 function.

Baby was treated with fluids and calcitonin to reverse hypercalcemia and lower vitamin-D levels and both biomarkers reached the normal levels within 3 months.

1.2

Vitamin-D toxicity due to manufacturing error

In 2013, Kara et al. also described vitamin-D toxicity in children, but in her cases the error was exclusively caused by the manufacturer producing fish oil supplements with concentration of vitamin-D that was 4,000 times the concentration stated on the label (Kara et al., 2014). Seven children, below age 4.2, were admitted to the hospital due to significant hypercalcemia (median serum Ca was 16.5 mg/dL; range: 13.4–18.8; reference range: 8.8–10.8 mg/dL). Serum phosphorous and PTH levels were found to be in normal range.

All children presented with similar clinical manifestations: vomiting, dehydration, constipation and weight loss. Median concentration of serum 25(OH)D was 620 ng/mL (range: 340–962 ng/mL; reference range: 30–80 ng/mL). It was later estimated that the children were receiving daily vitamin-D3 dosage between 266,000 IU and 8,000,000 IU, which was significantly above the normal recommendation (2,000 IU). Calcium levels in all children were corrected within 3 days (range: 2–7 days) and vitamin-D levels normalized within 3 months.

1.3

Vitamin-D toxicity from overcorrecting vitamin-D deficiency

In 2015, Kaur et al. described 16 patients who overdosed with vitamin-D supplements to treat their vitamin-D deficiencies (Kaur et al., 2015). All patients presented with similar symptoms of vitamin-D toxicity: vomiting, weight loss, nausea and constipation. Upon admission, patients were noted to have median (range) serum calcium level of 13.0 mg/dL (11.1–15.7 mg/dL), median (range) serum 25(OH)D of 371 ng/mL and normal phosphorous and PTH results. It was determined that patients were taking ~77,000 IU of vitamin-D3 each day over a period of 4–7 weeks and this mega-dose resulted in vitamin-D toxicity in all patients.

Source: Case histories Source: Case histories Source: Case histories

vitamin-D metabolite measurement and health and disease

Role of vitamin-D metabolite measurement in health and disease

Since vitamin-D3 and vitamin-D2 are either stored in adipose tissue or rapidly metabolized to the corresponding 25-hydroxylated metabolites, their serum levels fluctuate widely and there is no clinical value in monitoring these forms of vitamin-D in the circulation.

Among the >40 vitamin-D metabolites discovered so far, three have been shown to be the most clinically relevant: 25(OH)D, 1,25(OH)2D and 24,25(OH)2D.

25(OH)D serum concentrations are useful for assessing vitamin-D reserves. 25(OH)D levels increase steadily upon exposure of skin to UV-containing light or after consuming supplements containing cholecalciferol or ergocalciferol. In recent times, many investigators have explored associations between vitamin-D metabolism and cardiovascular disease, obesity, cancer, and autoimmune diseases (Delvin et al., 2014; Wang, 2009; Kulie et al., 2009; Holick, 2007); however, no clear recommendations for clinical interventions have yet emerged from these studies. By contrast, studies of bone health and 25(OH)D levels have at least in part resulted in clinically useful, albeit not always uncontested, conclusions.

One study, which investigated the effect of calcium and vitamin-D (cholecalciferol) supplementation on bone density in men and women older than 65 years, found a moderate reduction in bone loss in the femoral neck, spine, and total body over the three-year study period and a reduced incidence of non-vertebral fractures in the group supplemented with 500 mg of calcium plus 700 IU of vitamin D3 (cholecalciferol) per day compared to placebo (Dawson-Hughes et al., 1997). Vitamin-D supplementation was also shown to reduce the risk of falls by >20% among ambulatory or institutionalized older individuals with stable health (Bischoff-Ferrari et al., 2004).

Benefits of vitamin-D supplementation on fracture prevention are related to its effect on intestinal calcium absorption and bone mineral density (Bikle, 2012). However, in years that followed, the findings for falls and fractures in the elderly were mixed when supplementation with intermittent single large doses of vitamin-D (50,000–100,000 IU) was examined in randomized controlled trials (RCTs). A meta-analysis of nine RCTs found that supplementation with intermittent, high dose vitamin-D might not be effective in preventing overall mortality, fractures, or falls among older adults (Zheng et al., 2015).

The paradoxical increase in fracture-risk in some of the reviewed studies has been hypothesized to be caused by an up-regulation of the CYP24A1 enzyme and an increased clearance of 1,25(OH)2D.

The Institute of Medicine has recommended that at the low end a serum 25(OH)D level of at least 20 ng/mL is sufficient for 97.5% of the population for effective prevention of bone disease and fractures, while a level of 50 ng/mL is considered as a safe upper healthy population cut-off. Serum 25(OH)D levels <20 ng/mL represent deficiency (Fig. 2). For every 100 IU of vitamin-D supplement administered, the 25(OH)D levels rise by 0.5 to 1 ng/mL. Deficiency of 25(OH)D can cause bone pain and muscle weakness, and in extreme cases osteomalacia in adults and rickets in children.

However, mild deficiency may not necessarily be associated with overt symptoms. On the other end of the spectrum, sustained levels of 25-OH-vitamin D > 50 ng/mL might lead to hypercalciuria, stone formation and ultimately decreased renal function. Frank vitamin-D toxicity might occur at even higher levels and is characterized biochemically by hypercalcemia, hyperphosphatermia, suppressed serum PTH concentrations, and markedly elevated 25(OH)D levels. Clinical manifestations of severe toxicity include vomiting, nausea, abdominal pain, fatigue, and weakness, and sometimes rapidly developing nephrocalcinosis (Misselwitz et al., 1990).

Fig. 2

Frequency of patients with different 25-OH vitamin-D concentrations collected between July 2006 and December 2017. A) Deficiency; B) Insufficiency; C) Sufficiency; D) Toxicity.

Fig. 2Figure image at the original source — open the original paper. This file is not included in this text import.

The tight regulation of 1,25(OH)2D production means that its levels fluctuate little. Except in cases of extreme vitamin-D deficiency or toxicity 1,25(OH)2D serum concentrations typically remain 22–65 pg/mL. Therefore, serum 1,25(OH)2D measurements are in the main only indicated when there is suspicion of unregulated conversion of 25(OH)D to 1,25(OH)2D, as might be seen in some granulomatous diseases, or if patients have advanced renal impairment with or without 1,25(OH)2D replacement therapy.

A combination of measurements of serum 25(OH)D, 1,25(OH)2D, 24,25(OH)2D and C3-epi-25(OH)D might be necessary in the differential diagnosis of acquired- (e.g. granulomatous diseases), iatrogenic- (e.g. over-supplementation) and genetic causes (e.g. 24-hydroxylase deficiency) of non-PTH driven hypercalcemia. In recent years, 24,25(OH)2D has received a lot of attention in this context. It is a marker for CYP24A1 function when used in conjunction with 25(OH)D measurements. In normal individuals, 24,25(OH)2D is 7–35% of the total 25(OH)D (Ornoy et al., 1978).

A 25(OH)D/24,25(OH)2D ratio of 99 or greater is indicative of CYP24A1 deficiency.

Once the cause of vitamin-D toxicity has been established, serum vitamin-D levels might need to be monitored until they fall to about 30–50 ng/mL.

Source: Role of vitamin-D metabolite measurement in health and disease Source: Role of vitamin-D metabolite measurement in health and disease Source: Role of vitamin-D metabolite measurement in health and disease Source: Role of vitamin-D metabolite measurement in health and disease Source: Role of vitamin-D metabolite measurement in health and disease Source: Role of vitamin-D metabolite measurement in health and disease Source: Role of vitamin-D metabolite measurement in health and disease

Vitamin-D assays

Methodologies for 25(OH)D measurements include high performance liquid chromatography (HPLC), radioimmunoassay (RIA), automated immunoassays and liquid chromatography-tandem mass spectrometry (LC-MS/MS), while current 1,25(OH)2D and 24,25(OH)2D measurements involve RIAs or LC-MS/MS. Analytical challenges have been reported for all of these methods (Singh, 2008), but currently measurement of vitamin-D compounds by HPLC with MS/MS detection (Heijboer et al., 2012; Eisman and Deluca, 1978) has been established as the gold standard for vitamin-D metabolite testing

Despite this, automated immunoassays are the mainstay for the majority of high volume analytes in clinical laboratories. They offer high throughput and automated sample handling and require minimal manual labor. Consequently, 90% of routine 25(OH)D analyses today are performed by automated immunoassay. However, most automated immunoassays suffer from the inherent narrow dynamic range and specificity limitations of competitive immunoassays. The former results in these assays frequently either underestimating or overestimating 25(OH)D concentrations at both the low and the high end of their measurement range, i.e. precisely at the concentrations where accuracy would be most important (Kocak et al., 2015; Holmes et al., 2013; Farrell et al., 2012), while the latter manifests itself as unequal affinity for 25(OH)D2 versus 25(OH)D3, and occasional interferences (Tolan et al., 2017).

In concert, these issues also result in significant differences between the results of different immunoassays. The discordance between 25(OH)D values from different assays is magnified by differences in standardization of each assay (Snellman et al., 2010).

LC-MS/MS overcomes these issues and has become widely accepted for routine use for many low molecular weight analytes in clinical laboratories due to improved analytical specificity and sensitivity and wider dynamic range compared to immunoassay methods (Muller and Volmer, 2015; El-Khoury et al., 2011; Singh, 2010). LC-MS/MS vitamin-D assays offer better accuracy at medical decision levels to correctly classify patients as vitamin-D deficient and sufficient. Several LC-MS/MS methods for measurement of all clinically relevant metabolites of vitamin-D including 25(OH)D (Thacher et al., 2010; Singh et al., 2006), 1,25(OH)2D (Hoofnagle et al., 2010; Strathmann et al., 2011) and 24,25(OH)2D (Ketha et al., 2016) have been reported.

However, although LC-MS/MS is considered the gold standard for 25(OH)D testing, according to the Accuracy-Based Vitamin-D 2016 Survey, only 74 out of 364 US laboratories used LC-MS/MS for 25(OH)D testing. Initial capital investment, the labor and time intensive nature of development and implementation of clinical LC-MS/MS assays and slower turnaround time might be the keys impediments towards a global adoption of LC-MS/MS for vitamin-D metabolite quantitation (Grebe and Singh, 2011).

The College of American Pathologists (CAP) and Vitamin-D External quality assessment scheme (DEQAS) surveys are used to monitor the performance of laboratories using various methods for testing of 25(OH)D (Burdette et al., 2017). The survey feedback does not assess the accuracy of 25(OH)D measurements by laboratories, but scores laboratories for agreement within the group using a particular method. Additionally, lack of standardization has been recognized as a challenge in steroid hormone testing. The Center for Disease Control and Prevention has established a Vitamin-D Standardization Certification Program (VDSCP) focused on providing reference measurements for 25(OH)2D, to assess the accuracy and precision of vitamin-D tests, to monitor their performance over time, and provide technical support to external quality assurance programs, proficiency testing programs, and research studies (VDSCP: Vitamin-D Standardized-Certification Program).

A recent study by VDSCP study established core performance criteria, namely CV ≤ 10% and mean bias ≤5% for 25(OH)D quantitation. Inter-laboratory performance of 25(OH)D measurement was compared by providing a set of 50 individual donor samples to 15 laboratories representing national nutrition survey laboratories, assay manufacturers, and clinical or research laboratories. Samples were analyzed using immunoassays and LC-MS/MS. All LC-MS/MS results achieved VDSCP criteria, whereas only 50% of immunoassays met the criterion for a ≤ 10% CV and only three of eight immunoassays achieved the ≤5% bias (Wise et al., 2017).

Perhaps some of these issues might be addressed with the availability of National Institute of Standards and Technology (NIST) standard reference materials (Burdette et al., 2017; Thienpont et al., 2012), but even then the inherent problems of immunoassays will likely continue to negatively impact vitamin-D laboratory testing quality.

Source: Vitamin-D assays Source: Vitamin-D assays Source: Vitamin-D assays Source: Vitamin-D assays

Decreasing vitamin-D deficiency in the US

Decreasing vitamin-D deficiency in the US: lessons learnt from 10 years of LC-MS/MS 25(OH)D testing

During the first decade of the 21st century, Vitamin-D deficiency was shown to be highly prevalent in the USA (Holick, 2007). In the years that followed, several studies echoing these findings were reported. Consequently, the current decade has witnessed an increased public awareness of vitamin-D supplementation.

The clinical laboratory at the Mayo Clinic in Rochester, MN is a referral laboratory for a vast network of clinical providers in the US. During the 2007–2017, ~5,000,000 patient samples were tested for 25(OH)D by LC-MS/MS in our laboratory (Netzel et al., 2011). Patient results were categorized into the following groups <10 ng/mL, 10–24 ng/mL, 25–80 ng/mL and > 80 ng/mL. Frequencies were calculated by using the formula: ((Number of patients in a 25(OH)D category / total number of patients tested in the corresponding week) ∗ 100), in order to gauge whether there have been any changes in the frequency of 25(OH)D in the four categories over time.

The frequency of patients in each serum 25(OH)D category is shown in Fig. 2. Seasonal variation, as a reflection of the amount of sunlight to which a person is exposed, was observed in the <10 ng/mL, 10–24 ng/mL, 25–80 ng/mL categories. As expected, serum concentrations of 25(OH)D were highest in late summer and lowest in spring. At the end of summer of 2006 (shown in red, Fig. 2a), 4.3% of the population being tested had serum 25(OH)D levels <10 ng/mL.

This number increased to 8.5% by the end of winter of 2007. After 10 years, a significantly lower percentage of the population had serum 25(OH)D levels <10 ng/mL (0.2% and 3.1% post-summer and post-winter of 2017, respectively). Similarly, the percentage of patients with 25(OH)D range of 10–24 ng/mL decreased steadily between 2007 and 2017 (green, Fig. 2b). By contrast, the percentage of patients with 25(OH)D levels (between 25 and 80 ng/mL) increased from 72.5% to 82.4% post-summer and from 60.6 to 72.9% post-winter during the ten-year period (blue, Fig. 2c).

Of note, the percentage of patients with levels >80 ng/mL remained constant (1.1%), without seasonal variation until the end of 2012 (Fig. 2d). Since then, it has been slowly increasing to 2–2.5% probably due to an increased awareness of vitamin-D deficiency and an increased use of over-the-counter supplements and prescriptions of high-dose vitamin-D. Given that our 25(OH)D vitamin-D assay is a laboratory developed test, we have verified that there were neither a shifts in the calibration over time, nor biases and trends in quality controls nor biases due to reagent lot-to-lot changes.

Based on our data obtained with this assay of demonstrably stable analytical performance, it appears that vitamin-D supplementation is driving improvements in population 25(OH)D levels. Our findings are consistent with a recent study which also found modest increases in the serum 25(OH)D concentrations in the US population from 1988 to 2010 (Grebe and Singh, 2011).

The observation that serum 25(OH)D levels in the general US population have increased during the last decade has important implications. Population based and basic science studies exploring the role of vitamin-D metabolism in health and disease pathways have raised public awareness about effective modes of vitamin-D supplementation. Of note, the increase in the percentage of patients who have circulating concentration of 25(OH)D of >80 ng/mL warrants further attention. Long-term physiological effects of persistently elevated 25(OH)D may need to be investigated in clinical studies.

Source: Decreasing vitamin-D deficiency in the US – lessons learnt from 10 years of LC-MS/MS 25(OH)D testing Source: Decreasing vitamin-D deficiency in the US – lessons learnt from 10 years of LC-MS/MS 25(OH)D testing Source: Decreasing vitamin-D deficiency in the US – lessons learnt from 10 years of LC-MS/MS 25(OH)D testing Source: Decreasing vitamin-D deficiency in the US – lessons learnt from 10 years of LC-MS/MS 25(OH)D testing

Conclusion

Over the last decade, the frequency of measurements of 25(OH)D in the healthy population has significantly increased due to an increased awareness of vitamin-D deficiency and its potential association with many diseases beyond its role in maintaining bone health. This also resulted in an increased demand for vitamin-D metabolite measurements. Quantification of 25(OH)D in serum is the best indicator of vitamin-D status of individuals. 25(OH)D accurately reflects the body's vitamin-D stores. At present, LC-MS/MS assays offer the best accuracy for vitamin-D metabolite analysis.

Accurately measuring vitamin-D metabolite levels is important to classify patients as vitamin-D deficient so appropriate supplementation can be recommended. Monitoring patients who receive high-dose vitamin-D supplementation is also of clinical value. Our retrospective study has shown seasonal changes of 25(OH)D as well as an overall change in frequency of patients with vitamin-D deficiency and sufficiency. Of note our data show that the frequency of patients with 25(OH)D deficiency decreased over the last decade (2007–2017). The flip side of this is that the percentage of the patients undergoing 25(OH)D testing who have serum 25(OH)D > 80 ng/mL has slowly increased during that time.

While the proportion of patients with potentially toxic levels remains relatively low, the consequences of toxicity can be severe, and prospective population studies to investigate clinical impact and long-term safety of higher circulating levels of 25(OH)D might be warranted.

Source: Conclusion
Authors’ abstract

In early 2000's vitamin-D deficiency was shown to be prevalent in several countries including the United States (US). Studies exploring the role of vitamin-D metabolism in diverse disease pathways generated an increased demand for vitamin-D supplementation and an immense public interest in measurement of vitamin-D metabolite levels. In this report, we review the role of vitamin-D metabolism in disease processes, clinical utility of measuring vitamin-D metabolites including 25-hydroxyvitamin-D (25(OH)D), 1,25-dihydroxyvitamin-D and 24,25-dihydroxyvitamin-D and discuss vitamin-D assay methodologies including immunoassays and liquid chromatography mass spectrometry (LC-MS/MS) assays.

We also provide examples of vitamin-D toxicity and insight into the trends in serum 25(OH)D levels in the US population based on 10 years of data from on serum 25(OH)D values from ~5,000,000 patients who were tested at the Mayo Medical Laboratories between February 2007–February 2017.

Read the full paper
1

Case histories

1.1

Vitamin-D toxicity due to intentional vitamin-D overdose

In 2015, we reported a pediatric case of vitamin-D intoxication with vitamin-D3 supplements (Ketha et al., 2015). Briefly, four-month-old infant was admitted to Mayo Clinic for significant dehydration, lethargy, and weight loss. Routine chemistry blood panel revealed total calcium levels of 18.7 mg/dL indicating severe hypercalcemia. PTH levels were suppressed (<6 pg/mL; normal range: 15–65 pg/mL) and serum phosphorous was 1.9 mg/dL; normal range: 2.5–4.5 mg/dL. Further medical evaluation revealed hypercalciuria and nephrocalcinosis. During the discussion with the mother it was discovered, that in the last two months the infant was receiving daily dosage of oral vitamin-D3 supplementation that was greater than the manufacturer's recommendation.

It was estimated that the baby was receiving ~50,000 IU of vitamin-D per day while recommended dose on the label was 2,000 IU. It was also determined that the actual amount of vitamin-D per drop was 6,000 IU, 3 fold higher than what it was stated on the label (2,000 IU). Vitamin-D metabolites were tested in the infant's blood and were as follows: 25(OH)D3, 293 ng/mL (optimal range of total 25(OH)D:20–50 ng/mL); 1,25(OH)2D3, 138–111 pg/mL (optimal range: 24–86 pg/mL); ratio of 24,25(OH)2D3 to 25(OH)D3 was 0.11–0.14 (normal range: 0.07–0.18) and suggesting normal Cyp24A1 function.

Baby was treated with fluids and calcitonin to reverse hypercalcemia and lower vitamin-D levels and both biomarkers reached the normal levels within 3 months.

1.2

Vitamin-D toxicity due to manufacturing error

In 2013, Kara et al. also described vitamin-D toxicity in children, but in her cases the error was exclusively caused by the manufacturer producing fish oil supplements with concentration of vitamin-D that was 4,000 times the concentration stated on the label (Kara et al., 2014). Seven children, below age 4.2, were admitted to the hospital due to significant hypercalcemia (median serum Ca was 16.5 mg/dL; range: 13.4–18.8; reference range: 8.8–10.8 mg/dL). Serum phosphorous and PTH levels were found to be in normal range.

All children presented with similar clinical manifestations: vomiting, dehydration, constipation and weight loss. Median concentration of serum 25(OH)D was 620 ng/mL (range: 340–962 ng/mL; reference range: 30–80 ng/mL). It was later estimated that the children were receiving daily vitamin-D3 dosage between 266,000 IU and 8,000,000 IU, which was significantly above the normal recommendation (2,000 IU). Calcium levels in all children were corrected within 3 days (range: 2–7 days) and vitamin-D levels normalized within 3 months.

1.3

Vitamin-D toxicity from overcorrecting vitamin-D deficiency

In 2015, Kaur et al. described 16 patients who overdosed with vitamin-D supplements to treat their vitamin-D deficiencies (Kaur et al., 2015). All patients presented with similar symptoms of vitamin-D toxicity: vomiting, weight loss, nausea and constipation. Upon admission, patients were noted to have median (range) serum calcium level of 13.0 mg/dL (11.1–15.7 mg/dL), median (range) serum 25(OH)D of 371 ng/mL and normal phosphorous and PTH results. It was determined that patients were taking ~77,000 IU of vitamin-D3 each day over a period of 4–7 weeks and this mega-dose resulted in vitamin-D toxicity in all patients.

2

Background

Vitamin-D and parathyroid hormone (PTH) are the principle regulators of calcium homeostasis in all tetrapods and play an important role in bone metabolism (Lips and van Schoor, 2011; Pettifor and Prentice, 2011; Rizzoli, 2014). Vitamin-D exists in two major forms, vitamin-D2 (ergocalciferol) and vitamin-D3 (cholecalciferol). Both are formed by UV irradiation of either 7-dehydroergosterol (phytoplankton, fungi and yeast) or 7-dehydrocholesterol (all vertebrates with the exception of fish [predominately dietary-derived vitamin-D2]). The two forms differ only in the substitution on the side chain.

It is believed that vitamin-D2 first emerged in phytoplankton about 750 million years ago and served as the vitamin-D source for marine vertebrates until the transition to terrestrial life occurred and vitamin-D3 production commenced in the skin of tetrapods (Holick, 2008a).

In modern humans, primary sources of vitamin-D include diet or supplements (vitamin-D2 and/or-D3) and vitamin-D3 derived from 7-dehydrocholesterol in the skin after exposure to UV light (Fig. 1) (Holick, 2008b; Singh, 1985). Endogenous or dietary vitamin-D binds to vitamin-D binding protein and is transported to the liver, where it is hydroxylated at the carbon 25-position, creating 25-hydroxyvitamin-D (25(OH)D). 25(OH)D is the most abundant circulating form of the vitamin-D. Vitamin-D and 25(OH)D have no established bioactivity and can be viewed as pro-hormones.

Fig. 1

The vitamin-D metabolic pathway.

Fig. 1Figure image at the original source — open the original paper. This file is not included in this text import.

25-hydroxyvitamin-D-1α-hydroxylase (CYP27B1) in the kidneys converts 25(OH)D to the active hormone, 1,25-(OH)2D (Figure 1). 1,25-(OH)2D belongs to the superfamily of thyroid- and steroid hormones, and exerts its effects through changes in gene transcription. It binds to a nuclear receptor (Vitamin-D receptor, VDR) that dimerizes with the retinoid X receptor (RxR) before binding to gene regulatory DNA elements. There are between 2000 and 8000 VDR response elements in the human genome. Transcriptional response depends on the number of available VDR and RxR, the concentrations of their respective ligands, the nature of the response element (enhancing or inhibiting), availability of co-factors and transcriptional accessibility of the respective genes (Pike, 2016).

Consequently, the actions of 1,25-(OH)2D across various tissues of an entire animal are complex and in most cases require detailed study to detect clinically relevant changes. The areas that are exceptions to this rule are calcium and phosphate metabolism and bone metabolism. 1,25-(OH)2D obvious principle role is (i) to increase intestinal calcium absorption, (ii) to increase calcium and phosphate reabsorption in the kidneys, (iii) to increase calcium release from bones in concert with PTH, and (iv) to downregulate PTH production.

The activity of the CYP27B1 in turn is regulated by PTH and other factors including calcium demand.

Due to these feedback mechanism, production of 1,25(OH)2D remains constant over a wide range of serum 25(OH)D concentrations, with excess 25(OH)D and 1,25(OH)2D being converted to inactive metabolites, 24,25(OH)2D and 1,24,25(OH)3D by 25-hydroxyvitaminD-24-hydroxylase (CYP24A1). Additional, independent inactivation is catalyzed by 3-epimerase, which isomerizes the C-3 OH group of 25(OH)D and 1,25(OH)2D from the α to β orientation, reducing bioactivity (Bikle, 2014).

3

Role of vitamin-D metabolite measurement in health and disease

Since vitamin-D3 and vitamin-D2 are either stored in adipose tissue or rapidly metabolized to the corresponding 25-hydroxylated metabolites, their serum levels fluctuate widely and there is no clinical value in monitoring these forms of vitamin-D in the circulation.

Among the >40 vitamin-D metabolites discovered so far, three have been shown to be the most clinically relevant: 25(OH)D, 1,25(OH)2D and 24,25(OH)2D.

25(OH)D serum concentrations are useful for assessing vitamin-D reserves. 25(OH)D levels increase steadily upon exposure of skin to UV-containing light or after consuming supplements containing cholecalciferol or ergocalciferol. In recent times, many investigators have explored associations between vitamin-D metabolism and cardiovascular disease, obesity, cancer, and autoimmune diseases (Delvin et al., 2014; Wang, 2009; Kulie et al., 2009; Holick, 2007); however, no clear recommendations for clinical interventions have yet emerged from these studies. By contrast, studies of bone health and 25(OH)D levels have at least in part resulted in clinically useful, albeit not always uncontested, conclusions.

One study, which investigated the effect of calcium and vitamin-D (cholecalciferol) supplementation on bone density in men and women older than 65 years, found a moderate reduction in bone loss in the femoral neck, spine, and total body over the three-year study period and a reduced incidence of non-vertebral fractures in the group supplemented with 500 mg of calcium plus 700 IU of vitamin D3 (cholecalciferol) per day compared to placebo (Dawson-Hughes et al., 1997). Vitamin-D supplementation was also shown to reduce the risk of falls by >20% among ambulatory or institutionalized older individuals with stable health (Bischoff-Ferrari et al., 2004).

Benefits of vitamin-D supplementation on fracture prevention are related to its effect on intestinal calcium absorption and bone mineral density (Bikle, 2012). However, in years that followed, the findings for falls and fractures in the elderly were mixed when supplementation with intermittent single large doses of vitamin-D (50,000–100,000 IU) was examined in randomized controlled trials (RCTs). A meta-analysis of nine RCTs found that supplementation with intermittent, high dose vitamin-D might not be effective in preventing overall mortality, fractures, or falls among older adults (Zheng et al., 2015).

The paradoxical increase in fracture-risk in some of the reviewed studies has been hypothesized to be caused by an up-regulation of the CYP24A1 enzyme and an increased clearance of 1,25(OH)2D.

The Institute of Medicine has recommended that at the low end a serum 25(OH)D level of at least 20 ng/mL is sufficient for 97.5% of the population for effective prevention of bone disease and fractures, while a level of 50 ng/mL is considered as a safe upper healthy population cut-off. Serum 25(OH)D levels <20 ng/mL represent deficiency (Fig. 2). For every 100 IU of vitamin-D supplement administered, the 25(OH)D levels rise by 0.5 to 1 ng/mL. Deficiency of 25(OH)D can cause bone pain and muscle weakness, and in extreme cases osteomalacia in adults and rickets in children.

However, mild deficiency may not necessarily be associated with overt symptoms. On the other end of the spectrum, sustained levels of 25-OH-vitamin D > 50 ng/mL might lead to hypercalciuria, stone formation and ultimately decreased renal function. Frank vitamin-D toxicity might occur at even higher levels and is characterized biochemically by hypercalcemia, hyperphosphatermia, suppressed serum PTH concentrations, and markedly elevated 25(OH)D levels. Clinical manifestations of severe toxicity include vomiting, nausea, abdominal pain, fatigue, and weakness, and sometimes rapidly developing nephrocalcinosis (Misselwitz et al., 1990).

Fig. 2

Frequency of patients with different 25-OH vitamin-D concentrations collected between July 2006 and December 2017. A) Deficiency; B) Insufficiency; C) Sufficiency; D) Toxicity.

Fig. 2Figure image at the original source — open the original paper. This file is not included in this text import.

The tight regulation of 1,25(OH)2D production means that its levels fluctuate little. Except in cases of extreme vitamin-D deficiency or toxicity 1,25(OH)2D serum concentrations typically remain 22–65 pg/mL. Therefore, serum 1,25(OH)2D measurements are in the main only indicated when there is suspicion of unregulated conversion of 25(OH)D to 1,25(OH)2D, as might be seen in some granulomatous diseases, or if patients have advanced renal impairment with or without 1,25(OH)2D replacement therapy.

A combination of measurements of serum 25(OH)D, 1,25(OH)2D, 24,25(OH)2D and C3-epi-25(OH)D might be necessary in the differential diagnosis of acquired- (e.g. granulomatous diseases), iatrogenic- (e.g. over-supplementation) and genetic causes (e.g. 24-hydroxylase deficiency) of non-PTH driven hypercalcemia. In recent years, 24,25(OH)2D has received a lot of attention in this context. It is a marker for CYP24A1 function when used in conjunction with 25(OH)D measurements. In normal individuals, 24,25(OH)2D is 7–35% of the total 25(OH)D (Ornoy et al., 1978).

A 25(OH)D/24,25(OH)2D ratio of 99 or greater is indicative of CYP24A1 deficiency.

Once the cause of vitamin-D toxicity has been established, serum vitamin-D levels might need to be monitored until they fall to about 30–50 ng/mL.

4

Vitamin-D assays

Methodologies for 25(OH)D measurements include high performance liquid chromatography (HPLC), radioimmunoassay (RIA), automated immunoassays and liquid chromatography-tandem mass spectrometry (LC-MS/MS), while current 1,25(OH)2D and 24,25(OH)2D measurements involve RIAs or LC-MS/MS. Analytical challenges have been reported for all of these methods (Singh, 2008), but currently measurement of vitamin-D compounds by HPLC with MS/MS detection (Heijboer et al., 2012; Eisman and Deluca, 1978) has been established as the gold standard for vitamin-D metabolite testing

Despite this, automated immunoassays are the mainstay for the majority of high volume analytes in clinical laboratories. They offer high throughput and automated sample handling and require minimal manual labor. Consequently, 90% of routine 25(OH)D analyses today are performed by automated immunoassay. However, most automated immunoassays suffer from the inherent narrow dynamic range and specificity limitations of competitive immunoassays. The former results in these assays frequently either underestimating or overestimating 25(OH)D concentrations at both the low and the high end of their measurement range, i.e. precisely at the concentrations where accuracy would be most important (Kocak et al., 2015; Holmes et al., 2013; Farrell et al., 2012), while the latter manifests itself as unequal affinity for 25(OH)D2 versus 25(OH)D3, and occasional interferences (Tolan et al., 2017).

In concert, these issues also result in significant differences between the results of different immunoassays. The discordance between 25(OH)D values from different assays is magnified by differences in standardization of each assay (Snellman et al., 2010).

LC-MS/MS overcomes these issues and has become widely accepted for routine use for many low molecular weight analytes in clinical laboratories due to improved analytical specificity and sensitivity and wider dynamic range compared to immunoassay methods (Muller and Volmer, 2015; El-Khoury et al., 2011; Singh, 2010). LC-MS/MS vitamin-D assays offer better accuracy at medical decision levels to correctly classify patients as vitamin-D deficient and sufficient. Several LC-MS/MS methods for measurement of all clinically relevant metabolites of vitamin-D including 25(OH)D (Thacher et al., 2010; Singh et al., 2006), 1,25(OH)2D (Hoofnagle et al., 2010; Strathmann et al., 2011) and 24,25(OH)2D (Ketha et al., 2016) have been reported.

However, although LC-MS/MS is considered the gold standard for 25(OH)D testing, according to the Accuracy-Based Vitamin-D 2016 Survey, only 74 out of 364 US laboratories used LC-MS/MS for 25(OH)D testing. Initial capital investment, the labor and time intensive nature of development and implementation of clinical LC-MS/MS assays and slower turnaround time might be the keys impediments towards a global adoption of LC-MS/MS for vitamin-D metabolite quantitation (Grebe and Singh, 2011).

The College of American Pathologists (CAP) and Vitamin-D External quality assessment scheme (DEQAS) surveys are used to monitor the performance of laboratories using various methods for testing of 25(OH)D (Burdette et al., 2017). The survey feedback does not assess the accuracy of 25(OH)D measurements by laboratories, but scores laboratories for agreement within the group using a particular method. Additionally, lack of standardization has been recognized as a challenge in steroid hormone testing. The Center for Disease Control and Prevention has established a Vitamin-D Standardization Certification Program (VDSCP) focused on providing reference measurements for 25(OH)2D, to assess the accuracy and precision of vitamin-D tests, to monitor their performance over time, and provide technical support to external quality assurance programs, proficiency testing programs, and research studies (VDSCP: Vitamin-D Standardized-Certification Program).

A recent study by VDSCP study established core performance criteria, namely CV ≤ 10% and mean bias ≤5% for 25(OH)D quantitation. Inter-laboratory performance of 25(OH)D measurement was compared by providing a set of 50 individual donor samples to 15 laboratories representing national nutrition survey laboratories, assay manufacturers, and clinical or research laboratories. Samples were analyzed using immunoassays and LC-MS/MS. All LC-MS/MS results achieved VDSCP criteria, whereas only 50% of immunoassays met the criterion for a ≤ 10% CV and only three of eight immunoassays achieved the ≤5% bias (Wise et al., 2017).

Perhaps some of these issues might be addressed with the availability of National Institute of Standards and Technology (NIST) standard reference materials (Burdette et al., 2017; Thienpont et al., 2012), but even then the inherent problems of immunoassays will likely continue to negatively impact vitamin-D laboratory testing quality.

5

Decreasing vitamin-D deficiency in the US – lessons learnt from 10 years of LC-MS/MS 25(OH)D testing

During the first decade of the 21st century, Vitamin-D deficiency was shown to be highly prevalent in the USA (Holick, 2007). In the years that followed, several studies echoing these findings were reported. Consequently, the current decade has witnessed an increased public awareness of vitamin-D supplementation.

The clinical laboratory at the Mayo Clinic in Rochester, MN is a referral laboratory for a vast network of clinical providers in the US. During the 2007–2017, ~5,000,000 patient samples were tested for 25(OH)D by LC-MS/MS in our laboratory (Netzel et al., 2011). Patient results were categorized into the following groups <10 ng/mL, 10–24 ng/mL, 25–80 ng/mL and > 80 ng/mL. Frequencies were calculated by using the formula: ((Number of patients in a 25(OH)D category / total number of patients tested in the corresponding week) ∗ 100), in order to gauge whether there have been any changes in the frequency of 25(OH)D in the four categories over time.

The frequency of patients in each serum 25(OH)D category is shown in Fig. 2. Seasonal variation, as a reflection of the amount of sunlight to which a person is exposed, was observed in the <10 ng/mL, 10–24 ng/mL, 25–80 ng/mL categories. As expected, serum concentrations of 25(OH)D were highest in late summer and lowest in spring. At the end of summer of 2006 (shown in red, Fig. 2a), 4.3% of the population being tested had serum 25(OH)D levels <10 ng/mL.

This number increased to 8.5% by the end of winter of 2007. After 10 years, a significantly lower percentage of the population had serum 25(OH)D levels <10 ng/mL (0.2% and 3.1% post-summer and post-winter of 2017, respectively). Similarly, the percentage of patients with 25(OH)D range of 10–24 ng/mL decreased steadily between 2007 and 2017 (green, Fig. 2b). By contrast, the percentage of patients with 25(OH)D levels (between 25 and 80 ng/mL) increased from 72.5% to 82.4% post-summer and from 60.6 to 72.9% post-winter during the ten-year period (blue, Fig. 2c).

Of note, the percentage of patients with levels >80 ng/mL remained constant (1.1%), without seasonal variation until the end of 2012 (Fig. 2d). Since then, it has been slowly increasing to 2–2.5% probably due to an increased awareness of vitamin-D deficiency and an increased use of over-the-counter supplements and prescriptions of high-dose vitamin-D. Given that our 25(OH)D vitamin-D assay is a laboratory developed test, we have verified that there were neither a shifts in the calibration over time, nor biases and trends in quality controls nor biases due to reagent lot-to-lot changes.

Based on our data obtained with this assay of demonstrably stable analytical performance, it appears that vitamin-D supplementation is driving improvements in population 25(OH)D levels. Our findings are consistent with a recent study which also found modest increases in the serum 25(OH)D concentrations in the US population from 1988 to 2010 (Grebe and Singh, 2011).

The observation that serum 25(OH)D levels in the general US population have increased during the last decade has important implications. Population based and basic science studies exploring the role of vitamin-D metabolism in health and disease pathways have raised public awareness about effective modes of vitamin-D supplementation. Of note, the increase in the percentage of patients who have circulating concentration of 25(OH)D of >80 ng/mL warrants further attention. Long-term physiological effects of persistently elevated 25(OH)D may need to be investigated in clinical studies.

6

Conclusion

Over the last decade, the frequency of measurements of 25(OH)D in the healthy population has significantly increased due to an increased awareness of vitamin-D deficiency and its potential association with many diseases beyond its role in maintaining bone health. This also resulted in an increased demand for vitamin-D metabolite measurements. Quantification of 25(OH)D in serum is the best indicator of vitamin-D status of individuals. 25(OH)D accurately reflects the body's vitamin-D stores. At present, LC-MS/MS assays offer the best accuracy for vitamin-D metabolite analysis.

Accurately measuring vitamin-D metabolite levels is important to classify patients as vitamin-D deficient so appropriate supplementation can be recommended. Monitoring patients who receive high-dose vitamin-D supplementation is also of clinical value. Our retrospective study has shown seasonal changes of 25(OH)D as well as an overall change in frequency of patients with vitamin-D deficiency and sufficiency. Of note our data show that the frequency of patients with 25(OH)D deficiency decreased over the last decade (2007–2017). The flip side of this is that the percentage of the patients undergoing 25(OH)D testing who have serum 25(OH)D > 80 ng/mL has slowly increased during that time.

While the proportion of patients with potentially toxic levels remains relatively low, the consequences of toxicity can be severe, and prospective population studies to investigate clinical impact and long-term safety of higher circulating levels of 25(OH)D might be warranted.

Conflict of interest

I have no conflict of Interest for the data in this publication.

References

Bikle D.D. Vitamin D and bone Curr. Osteoporos. Rep. 10 2 2012 151 159 (PubMed PMID: 22544628; PubMed Central PMCID: PMCPMC3688475) 22544628 10.1007/s11914-012-0098-z PMC3688475
Bikle D.D. Vitamin D metabolism, mechanism of action, and clinical applications Chem. Biol. 21 3 2014 319 329 (PubMed PMID: 24529992; PubMed Central PMCID: PMCPMC3968073) 24529992 10.1016/j.chembiol.2013.12.016 PMC3968073
Bischoff-Ferrari H.A. Dawson-Hughes B. Willett W.C. Staehelin H.B. Bazemore M.G. Zee R.Y. Effect of vitamin D on falls: a meta-analysis JAMA 291 16 2004 1999 2006 Epub 2004/04/29https://doi.org/10.1001/jama.291.16.1999(PubMed PMID: 15113819) 15113819 10.1001/jama.291.16.1999
Burdette C.Q. Camara J.E. Nalin F. Pritchett J. Sander L.C. Arid G.D.C. Establishing an accuracy basis for the vitamin D external quality assessment scheme (DEQAS) J. AOAC Int. 100 5 2017 1277 1287 (PubMed PMID: WOS:000411552000008) 28847346 10.5740/jaoacint.17-0306
Dawson-Hughes B. Harris S.S. Krall E.A. Dallal G.E. Effect of calcium and vitamin D supplementation on bone density in men and women 65 years of age or older New Engl. J. Med. 337 10 1997 670 676 (PubMed PMID: 9278463) 9278463 10.1056/NEJM199709043371003
Delvin E. Souberbielle J.C. Viard J.P. Salle B. Role of vitamin D in acquired immune and autoimmune diseases Crit. Rev. Clin. Lab. Sci. 51 4 2014 232 247 (PubMed PMID: 24813330) 24813330 10.3109/10408363.2014.901291
Eisman J.A. DeLuca H.F. Determination of vitamin D metabolites Methods Enzymol. 52 1978 388 398 (PubMed PMID: 209289) 209289 10.1016/s0076-6879(78)52043-0
El-Khoury J.M. Reineks E.Z. Wang S. Progress of liquid chromatography-mass spectrometry in measurement of vitamin D metabolites and analogues Clin. Biochem. 44 1 2011 66 76 (PubMed PMID: 20493831) 20493831 10.1016/j.clinbiochem.2010.05.007
Farrell C.J. Martin S. Mcwhinney B. Straub I. Williams P. Herrmann M. State-of-the-art vitamin D assays: a comparison of automated immunoassays with liquid chromatography-tandem mass spectrometry methods Clin. Chem. 58 3 2012 531 542 (PubMed PMID: 22230812) 22230812 10.1373/clinchem.2011.172155
Grebe S.K. Singh R.J. LC-MS/MS in the clinical laboratory - where to from here? Clin. Biochem. Rev. 32 1 2011 5 31 (Epub 2011/04/01. PubMed PMID: 21451775; PubMed Central PMCID: PMC3052391) 21451775 PMC3052391
Heijboer A.C. Blankenstein M.A. Kema I.P. Buijs M.M. Accuracy of 6 routine 25-hydroxyvitamin D assays: influence of vitamin D binding protein concentration Clin. Chem. 58 3 2012 543 548 (PubMed PMID: 22247500) 22247500 10.1373/clinchem.2011.176545
Holick M.F. Vitamin D deficiency N. Engl. J. Med. 357 3 2007 266 281 (PubMed PMID: 17634462) 17634462 10.1056/NEJMra070553
Holick M.F. Sunlight, Vitamin D and Health: a D-lightful Story2008 The Norwegian Academy of Sciences and Letters147 166
Holick M.F. Deficiency of sunlight and vitamin D BMJ 336 7657 2008 1318 1319 (PubMed PMID: 18556276; PubMed Central PMCID: PMCPMC2427138) 18556276 10.1136/bmj.39581.411424.80 PMC2427138
Holmes E.W. Garbincius J. Mckenna K.M. Analytical variability among methods for the measurement of 25-hydroxyvitamin D: still adding to the noise Am. J. Clin. Pathol. 140 4 2013 550 560 (PubMed PMID: 24045553) 24045553 10.1309/AJCPU2SKW1TFKSWY
Hoofnagle A.N. Laha T.J. Donaldson T.F. A rubber transfer gasket to improve the throughput of liquid-liquid extraction in 96-well plates: application to vitamin D testing J. Chromatogr. B Anal. Technol. Biomed. Life Sci. 878 19 2010 1639 1642 Epub 2010/05/07https://doi.org/10.1016/j.jchromb.2010.04.010(PubMed PMID: 20444657; PubMed Central PMCID: PMCPmc2877171) 10.1016/j.jchromb.2010.04.010 PMC2877171 20444657
Kara C. Gunindi F. Ustyol A. Aydin M. Vitamin D intoxication due to an erroneously manufactured dietary supplement in seven children Pediatrics 133 1 2014 e240 e244 (PubMed PMID: 24298009) 24298009 10.1542/peds.2013-0711
Kaur P. Mishra S.K. Mithal A. Vitamin D toxicity resulting from overzealous correction of vitamin D deficiency Clin. Endocrinol. 83 3 2015 327 331 Epub 2015/06/09https://doi.org/10.1111/cen.12836(PubMed PMID: 26053339) 10.1111/cen.12836 26053339
Ketha H. Wadams H. Lteif A. Singh R.J. Iatrogenic vitamin D toxicity in an infant—a case report and review of literature J. Steroid Biochem. Mol. Biol. 148 2015 14 18 (PubMed PMID: 25636720) 25636720 10.1016/j.jsbmb.2015.01.022
Ketha H. Kumar R. Singh R.J. LC-MS/MS for identifying patients with CYP24A1 mutations Clin. Chem. 62 1 2016 236 242 Epub 2015/11/21https://doi.org/10.1373/clinchem.2015.244459(PubMed PMID: 26585929) 26585929 10.1373/clinchem.2015.244459
Kocak F.E. Ozturk B. Isiklar O.O. Genc O. Unlu A. Altuntas I. A comparison between two different automated total 25-hydroxyvitamin D immunoassay methods using liquid chromatography-tandem mass spectrometry Biochem. Med. (Zagreb) 25 3 2015 430 438 (PubMed PMID: 26526462; PubMed Central PMCID: PMCPMC4622190) 26526462 10.11613/BM.2015.044 PMC4622190
Kulie T. Groff A. Redmer J. Hounshell J. Schrager S. Vitamin D: an evidence-based review J. Am. Board Fam. Med. 22 6 2009 698 706 (PubMed PMID: 19897699) 19897699 10.3122/jabfm.2009.06.090037
Lips P. van Schoor N.M. The effect of vitamin D on bone and osteoporosis Best Pract. Res. Clin. Endocrinol. Metab. 25 4 2011 585 591 (PubMed PMID: 21872800) 21872800 10.1016/j.beem.2011.05.002
Misselwitz J. Hesse V. Markestad T. Nephrocalcinosis, hypercalciuria and elevated serum levels of 1,25-dihydroxyvitamin D in children. Possible link to vitamin D toxicity Acta Paediatr. Scand. 79 6–7 1990 637 643 (PubMed PMID: 2386055) 2386055 10.1111/j.1651-2227.1990.tb11528.x
Muller M.J. Volmer D.A. Mass spectrometric profiling of vitamin D metabolites beyond 25-hydroxyvitamin D Clin. Chem. 61 8 2015 1033 1048 (PubMed PMID: 26130585) 26130585 10.1373/clinchem.2015.241430
Netzel B.C. Cradic K.W. Bro E.T. Girtman A.B. Cyr R.C. Singh R.J. Increasing liquid chromatography-tandem mass spectrometry throughput by mass tagging: a sample-multiplexed high-throughput assay for 25-hydroxyvitamin D2 and D3 Clin. Chem. 57 3 2011 431 440 Epub 2011/01/20https://doi.org/10.1373/clinchem.2010.157115(PubMed PMID: 21245371) 21245371 10.1373/clinchem.2010.157115
Ornoy A. Goodwin D. Noff D. Edelstein S. 24, 25-dihydroxyvitamin D is a metabolite of vitamin D essential for bone formation Nature 276 5687 1978 517 519 (PubMed PMID: 723936) 723936 10.1038/276517a0
Pettifor J.M. Prentice A. The role of vitamin D in paediatric bone health Best Pract. Res. Clin. Endocrinol. Metab. 25 4 2011 573 584 (PubMed PMID: 21872799) 21872799 10.1016/j.beem.2011.06.010
Pike W. Genomic determinants of vitamin D-regulated gene expression Vitam. Horm. 2016 21 44 26827947 10.1016/bs.vh.2015.10.011 PMC5113140
Rizzoli R. Nutritional aspects of bone health Best Pract. Res. Clin. Endocrinol. Metab. 28 6 2014 795 808 (PubMed PMID: 25432353) 25432353 10.1016/j.beem.2014.08.003
Singh R.B. Vitamin D supplementation J. Assoc. Physicians India 33 11 1985 751 752 (PubMed PMID: 4093398) 4093398
Singh R.J. Are clinical laboratories prepared for accurate testing of 25-hydroxy vitamin D? Clin. Chem. 54 1 2008 221 223 (PubMed PMID: 18160734) 18160734 10.1373/clinchem.2007.096156
Singh R.J. Quantitation of 25-OH-vitamin D (25OHD) using liquid tandem mass spectrometry (LC-MS-MS) Methods Mol. Biol. 603 2010 509 517 (PubMed PMID: 20077103) 20077103 10.1007/978-1-60761-459-3_50
Singh R.J. Taylor R.L. Reddy G.S. Grebe S.K. C-3 epimers can account for a significant proportion of total circulating 25-hydroxyvitamin D in infants, complicating accurate measurement and interpretation of vitamin D status J. Clin. Endocrinol. Metab. 91 8 2006 3055 3061 Epub 2006/05/25https://doi.org/10.1210/jc.2006-0710(PubMed PMID: 16720650) 16720650 10.1210/jc.2006-0710
Snellman G. Melhus H. Gedeborg R. Byberg L. Berglund L. Wernroth L. Determining vitamin D status: a comparison between commercially available assays PLoS One 5 7 2010 (PubMed PMID: 20644628; PubMed Central PMCID: PMCPMC2903481) 10.1371/journal.pone.0011555 PMC2903481 20644628
Strathmann F.G. Laha T.J. Hoofnagle A.N. Quantification of 1alpha,25-dihydroxy vitamin D by immunoextraction and liquid chromatography-tandem mass spectrometry Clin. Chem. 57 9 2011 1279 1285 Epub 2011/07/20https://doi.org/10.1373/clinchem.2010.161174(PubMed PMID: 21768219; PubMed Central PMCID: PMC3261234) 21768219 10.1373/clinchem.2010.161174 PMC3261234
Thacher T.D. Fischer P.R. Obadofin M.O. Levine M.A. Singh R.J. Pettifor J.M. Comparison of metabolism of vitamins D2 and D3 in children with nutritional rickets J. Bone Miner. Res. 25 9 2010 1988 1995 Epub 2010/05/26https://doi.org/10.1002/jbmr.99(PubMed PMID: 20499377; PubMed Central PMCID: PMC3153403) 20499377 10.1002/jbmr.99 PMC3153403
Thienpont L.M. Stepman H.C. Vesper H.W. Standardization of measurements of 25-hydroxyvitamin D3 and D2 Scand. J. Clin. Lab. Investig. Suppl. 243 2012 41 49 (PubMed PMID: 22536761; PubMed Central PMCID: PMCPMC5813281) 22536761 10.3109/00365513.2012.681950 [link unavailable; original address: https://doi.org/10.3109/00365513.2012.681950] PMC5813281
Tolan N.V. Yoon E.J. Brady A.R. Horowitz G.L. Price of high-throughput 25-Hydroxyvitamin D immunoassays: frequency of inaccurate results J. Appl. Lab. Med. 2017 10.1373/jalm.2017.024323 33636826
VDSCP: Vitamin D Standardization-Certification Program [cited 2018 3/9/2018]. Available fromhttps://www.cdc.gov/labstandards/vdscp.html [link unavailable]
Wang S. Epidemiology of vitamin D in health and disease Nutr. Res. Rev. 22 2 2009 188 203 (PubMed PMID: 19860998) 19860998 10.1017/S0954422409990151
Wise S.A. Phinney K.W. Tai S.S. Camara J.E. Myers G.L. Durazo-Arvizu R. Baseline assessment of 25-hydroxyvitamin D assay performance: a vitamin D standardization program (VDSP) interlaboratory comparison study J. AOAC Int. 100 5 2017 1244 1252 Epub 2017/08/22https://doi.org/10.5740/jaoacint.17-0258(PubMed PMID: 28822355) 28822355 10.5740/jaoacint.17-0258
Zheng Y.T. Cui Q.Q. Hong Y.M. Yao W.G. A meta-analysis of high dose, intermittent vitamin D supplementation among older adults PLoS One 10 1 2015 (PubMed PMID: 25602255; PubMed Central PMCID: PMCPMC4300188) 10.1371/journal.pone.0115850 PMC4300188 25602255
Publication and source details

Original title: 10 years of 25-hydroxyvitamin-D testing by LC-MS/MS-trends in vitamin-D deficiency and sufficiency

Kornelia Galior; Hemamalini Ketha; Stefan Grebe; Ravinder J Singh

Bone Reports · 2018

⁎ Corresponding author at: Department of Laboratory Medicine and Pathology, Mayo Clinic, 3050 Superior Dr NW, Rochester, MN 55901, United States. Singh.Ravinder@mayo.edu© 2018 The Authors2018https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/).

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-11T04:35:26.543251+00:00

DOI: 10.1016/j.bonr.2018.05.003 · PMC6020395