Primary relevance to vitamin D Vitamin D is a stated subject of this paper.
Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.
Why this paper is included
Supporting source evidence:
A Comparison between Three Different Automated Total 25-hydroxyvitamin D Immunoassay Methods and Ultra Performance Liquid Chromatography
Source: Article title. View original paper
Relevance classification does not establish study quality, causation or editorial approval.
Study design Study design awaiting verification.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.
Meta-analysis unclear · Blinding unclear / not reported · Research setting awaiting verification
How this paper was classified
Automatic source-based classification; awaiting editorial verification. This is not a quality score.
What the study types mean
- Systematic review
- Uses explicit methods to identify, assess and summarise research on a defined question.
- Scoping review
- Maps the extent and characteristics of research on a topic.
- Narrative review
- Discusses existing research; systematic-review methods have not been established by this classification.
- Review / evidence synthesis
- Reviews existing research; the exact review methods need further assessment.
- Randomised controlled trial
- Assigns participants or groups to comparison interventions by chance.
- Non-randomised intervention study
- Examines an intervention without random allocation.
- Cohort study
- Examines exposures and outcomes over time within a defined group.
- Case-control study
- Compares people with an outcome against people without it, examining exposures.
- Cross-sectional study
- Examines a population at a particular point in time.
- Observational study
- Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
- Case report
- Describes an individual case.
- Case series
- Describes a group of individual cases.
- Secondary analysis
- Analyses existing study data; this paper is not automatically another independent trial.
- Laboratory study
- Investigates biological processes in a laboratory setting.
- Qualitative study
- Examines experiences or meanings using qualitative methods.
- Genetic instrumental-variable study
- Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
- Study protocol
- Describes planned methods and is not evidence that the planned study has reported results.
- Multiple reported designs
- More than one design is explicitly reported; examine the supporting methods.
- Study design awaiting verification
- The available source does not establish a sufficiently clear study design.
Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.
Abstracts
A Comparison between Three Different Automated Total 25-hydroxyvitamin D Immunoassay Methods and Ultra Performance Liquid Chromatography
Study design awaiting verification · Asian Pacific Journal of Cancer Prevention : APJCP · 2020
Original publication title
A Comparison between Three Different Automated Total 25-hydroxyvitamin D Immunoassay Methods and Ultra Performance Liquid Chromatography
Original publication · Publisher record · CC BY 3.0
Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.
At a glance
Abstract: What objectives does the paper state?
Vitamin D is a fat soluble vitamin responsible for calcium metabolism and more recently discovered effects. This led to an increase in requests for vitamin D test by clinicians. New automated assays have been introduced for 25-hydroxyvitamin D measurement.
Source: Objective:Abstract: What methods does the paper describe?
Results from these new method have to be related to a Standard method to obtain best results for practical usage. In our study, one hundred venous blood samples were analyzed for 25-OH vitamin D on three immunological methods in our lab and correlated with ultra-performance liquid chromatography (UPLC) method as a reference method.
Source: Methods:Abstract: Results
Statistically analysis of results obtained for correlations between the 3 methods against the reference UPLC was done by Spearman’s Correlation. It showed positive correlation in all methods with significant p value < 0.001. Differences and biases between methods were evaluated using a Bland-Altman plot and Cohen’s Kappa agreement. Best agreement was found in Cobas 6000 followed by the Access2 then comes Architect.
Source: Results:Abstract: Conclusions
All immunoassays can be used in routine 25(OH) D measurements, still some methods are better than others. A clinical laboratory must at least be aware of its method to avoid misinterpretation of results.
Source: Conclusions:Authors’ abstract
Objective:
Vitamin D is a fat soluble vitamin responsible for calcium metabolism and more recently discovered effects. This led to an increase in requests for vitamin D test by clinicians. New automated assays have been introduced for 25-hydroxyvitamin D measurement.
Methods:
Results from these new method have to be related to a Standard method to obtain best results for practical usage. In our study, one hundred venous blood samples were analyzed for 25-OH vitamin D on three immunological methods in our lab and correlated with ultra-performance liquid chromatography (UPLC) method as a reference method.
Results:
Statistically analysis of results obtained for correlations between the 3 methods against the reference UPLC was done by Spearman’s Correlation. It showed positive correlation in all methods with significant p value < 0.001. Differences and biases between methods were evaluated using a Bland-Altman plot and Cohen’s Kappa agreement. Best agreement was found in Cobas 6000 followed by the Access2 then comes Architect.
Conclusions:
All immunoassays can be used in routine 25(OH) D measurements, still some methods are better than others. A clinical laboratory must at least be aware of its method to avoid misinterpretation of results.
Publication and source details
Original title: A Comparison between Three Different Automated Total 25-hydroxyvitamin D Immunoassay Methods and Ultra Performance Liquid Chromatography
Hala Reda; Sonya Soliman; Hany Girguis; Mohamed Nagy; Yousra Mahmoud; Nouran Yasser
Asian Pacific Journal of Cancer Prevention : APJCP · 2020
* For Correspondence: Hala.Reda@57357.orghttps://creativecommons.org/licenses/by/3.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License, (http://creativecommons.org/licenses/by/3.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.Repository JATS snapshot; version as supplied
Source retrieved: 2026-11-11T17:44:07.680114+00:00
DOI: 10.31557/apjcp.2020.21.4.1039 · PMC7445983