Vitamin D3 for Life. Live Enlightened.

Research libraryVitamin D3 For Life
Study design and methods

Secondary relevance to vitamin D This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.

This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.

Why this paper is included

Supporting source evidence:

PV and total mass of retinol (r = 0.90), 25(OH)D (r = 0.75), zinc (r = 0.88), copper (r = 0.83), magnesium (r = 0.93), manganese (r = 0.72), and iron (r = 0.92) were strongly correlated (all p < 0.05).

Source: Abstract. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Study design awaiting verification.

Study design awaiting verification

The available source does not establish a sufficiently clear study design.

Meta-analysis unclear · Blinding unclear / not reported · Human research reported

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

The participants were pre-screened via telephone.

Source: Methods.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Abstracts

A methodology for examining the association between plasma volume and micronutrient biomarker mass and concentration in healthy eumenorrheic women

Study design awaiting verification · PeerJ · 2020

Original publication title

A methodology for examining the association between plasma volume and micronutrient biomarker mass and concentration in healthy eumenorrheic women

Sixtus Aguree; Alison D. Gernand

©2020 Aguree and Gernand

Original publication · Publisher record · CC BY 4.0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

Authors’ conclusion

Though there appear to be some association between micronutrient biomarker mass and plasma volume, we are unable to draw a firm conclusion about any relationship from these results because of the small sample size. We consider these findings as a preliminary analysis to establish methods for future studies.

An extract from the source publication. Read it in context.

At a glance

Abstract: What background does the paper provide?

Accurate estimation and interpretation of nutritional biomarker concentrations are important in nutritional research, clinical care, and public health surveillance. Plasma volume (PV) may affect the interpretation of plasma biomarkers but is rarely measured. We aimed to examine the association between plasma volume (PV) and micronutrient biomarker concentrations and mass as part of pilot work to develop methods.

Source: Background

Abstract: What methods does the paper describe?

Nine healthy women with regular menstrual cycles provided fasting blood samples to measure micronutrient biomarkers. Indocyanine green was injected, and five timed blood draws were taken from 2 to 5 min to measure PV. Visits were scheduled around menstrual cycle day 2. Retinol, 25-hydroxyvitamin D, riboflavin, alpha-tocopherol, zinc, copper, magnesium, manganese, cobalt, iron, and ferritin concentrations were measured in serum. Total circulating micronutrient biomarker mass was calculated from PV and concentration.

Source: Methods

Abstract: Results

The mean PV was 2067 ±  470 mL. PV correlated positively with concentration of iron (r = 0.87, P = 0.005); other correlations were weaker with p > 0.05. PV and total mass of retinol (r = 0.90), 25(OH)D (r = 0.75), zinc (r = 0.88), copper (r = 0.83), magnesium (r = 0.93), manganese (r = 0.72), and iron (r = 0.92) were strongly correlated (all p < 0.05). PV was positively correlated with circulating micronutrient mass for most biomarkers, implying that concentrations are maintained at different volumes of plasma.

Larger studies are needed to further examine these relationships.

Source: Results

Abstract: Conclusion

Though there appear to be some association between micronutrient biomarker mass and plasma volume, we are unable to draw a firm conclusion about any relationship from these results because of the small sample size. We consider these findings as a preliminary analysis to establish methods for future studies.

Source: Conclusion
Authors’ abstract

Background

Accurate estimation and interpretation of nutritional biomarker concentrations are important in nutritional research, clinical care, and public health surveillance. Plasma volume (PV) may affect the interpretation of plasma biomarkers but is rarely measured. We aimed to examine the association between plasma volume (PV) and micronutrient biomarker concentrations and mass as part of pilot work to develop methods.

Methods

Nine healthy women with regular menstrual cycles provided fasting blood samples to measure micronutrient biomarkers. Indocyanine green was injected, and five timed blood draws were taken from 2 to 5 min to measure PV. Visits were scheduled around menstrual cycle day 2. Retinol, 25-hydroxyvitamin D, riboflavin, alpha-tocopherol, zinc, copper, magnesium, manganese, cobalt, iron, and ferritin concentrations were measured in serum. Total circulating micronutrient biomarker mass was calculated from PV and concentration.

Results

The mean PV was 2067 ±  470 mL. PV correlated positively with concentration of iron (r = 0.87, P = 0.005); other correlations were weaker with p > 0.05. PV and total mass of retinol (r = 0.90), 25(OH)D (r = 0.75), zinc (r = 0.88), copper (r = 0.83), magnesium (r = 0.93), manganese (r = 0.72), and iron (r = 0.92) were strongly correlated (all p < 0.05). PV was positively correlated with circulating micronutrient mass for most biomarkers, implying that concentrations are maintained at different volumes of plasma.

Larger studies are needed to further examine these relationships.

Conclusion

Though there appear to be some association between micronutrient biomarker mass and plasma volume, we are unable to draw a firm conclusion about any relationship from these results because of the small sample size. We consider these findings as a preliminary analysis to establish methods for future studies.

Publication and source details

Original title: A methodology for examining the association between plasma volume and micronutrient biomarker mass and concentration in healthy eumenorrheic women

Sixtus Aguree; Alison D. Gernand

PeerJ · 2020

©2020 Aguree and Gernand2020Aguree and Gernandhttps://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, reproduction and adaptation in any medium and for any purpose provided that it is properly attributed. For attribution, the original author(s), title, publication source (PeerJ) and either DOI or URL of the article must be cited. College of Health and Human Development, The Pennsylvania State University National Center for Advancing Translational Sciences National Institutes of Health, through GrantUL1 TR002014This work was supported by the College of Health and Human Development, The Pennsylvania State University. Additionally, the project described was supported by the National Center for Advancing Translational Sciences, National Institutes of Health, through Grant UL1 TR002014. The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-11T15:00:10.442537+00:00

DOI: 10.7717/peerj.10535 · PMC7759127