Vitamin D3 for Life. Live Enlightened.

Research libraryVitamin D3 For Life
Study design and methods

Primary relevance to vitamin D Vitamin D is a stated subject of this paper.

Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.

Why this paper is included

Supporting source evidence:

Analysis of Osteocalcin Hormone Proteoforms with Vitamin D Deficiency in Patients with Diabetes Mellitus Using Multiple-Reaction Monitoring–Mass Spectrometric Immunoassay Approach

Source: Article title. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Study design awaiting verification.

Study design awaiting verification

The available source does not establish a sufficiently clear study design.

Meta-analysis unclear · Blinding unclear / not reported · Human research reported

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

Patients were assessed for their vit D status and categorized accordingly.

Source: Methods.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Full studies

Analysis of Osteocalcin Hormone Proteoforms with Vitamin D Deficiency in Patients with Diabetes Mellitus Using Multiple-Reaction Monitoring-Mass Spectrometric Immunoassay Approach

Study design awaiting verification · Methods and Protocols · 2026

Original publication title

Analysis of Osteocalcin Hormone Proteoforms with Vitamin D Deficiency in Patients with Diabetes Mellitus Using Multiple-Reaction Monitoring–Mass Spectrometric Immunoassay Approach

Refat M. Nimer; Hicham Benabdelkamel; Afshan Masood; Maha Al Mogren; Salini Scaria Joy; Anas M. Abdel Rahman; Assim A. Alfadda

© 2026 by the authors.

Original publication · Publisher record · CC BY 4.0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

Authors’ conclusion

The multiple reaction monitoring–mass spectrometric immunoassay (MRM-MSIA) assay has proven to be useful in the quantitation of OC proteoforms as it demonstrated good analytical performance characterized by low LLOD and LLOQ, good precision, reproducibility, stability, and recovery. The results highlight the substantial potential of OC proteoforms as potential biomarkers for monitoring in patients with T2DM and vit D deficiency. Additionally, further investigation is warranted to establish a definitive relationship between vit D supplementation and the distribution of OC proteoforms.

An extract from the source publication. Read it in context.

At a glance

Study background

What background does the paper provide?

Osteocalcin (OC), also known as bone gamma-carboxyglutamic acid (Gla) protein (BGP), is a 5.7 kDa peptide comprising 49 amino acids. It is synthesized by osteoblasts and is the most abundant noncollagenous protein in the bone matrix [1]. OC is initially produced as a 98-amino-acid pre-pro-protein, which undergoes proteolytic processing to yield the mature form. This mature OC, called carboxylated OC (cOC), binds strongly to bone and the extracellular matrix. It undergoes γ-carboxylation at three glutamic acid residues (positions 17, 21, and 24) by the enzyme γ-glutamyl carboxylase.

Alongside vit D (vit D), OC was originally postulated to function in extracellular matrix mineralization and has been employed as a circulating biomarker of osteoblastic bone formation [2,3].

In recent years, studies have highlighted the involvement of both vit D and OC in insulin resistance and the development of metabolic diseases such as type 2 diabetes mellitus (T2DM) [4,5,6]. Uncarboxylated OC (ucOC) has been shown to stimulate insulin secretion from pancreatic islets and plays a key role in glucose homeostasis [7].

Deficiency of vit D is common worldwide, particularly among individuals suffering from T2DM. Recent studies have shown that more than 50% of patients with T2DM are suffering from vit D deficiency [8,9]. Furthermore, vit D adequacy is important for better glycemic control, particularly in vulnerable populations or individuals who have vitamin D deficiency. These findings highlight the strong link between low vit D status and glucose metabolism, and the significance of the investigation of vit D-based biomarkers and the interrelation between vit D and OC in diabetes [10].

OC levels have been associated with serum 25-hydroxyvitamin D [25(OH)D] concentrations, which are frequently reduced in individuals who are overweight or at elevated risk for developing T2DM [11]. Vit D status is typically classified as deficient when levels are <50 nmol/L, insufficient between 50 and 70 nmol/L, and sufficient when >75 nmol/L [12].

The γ-carboxylated residues of OC are essential for calcium binding. However, under the acidic conditions of osteoclast resorption compartments, OC undergoes decarboxylation, reducing its bone-binding affinity and promoting the release of ucOC into the bloodstream [13]. In addition to the intact protein, multiple OC fragments are present in the bloodstream [14]. Vit D directly increases OC gene transcription via a vit D responsive element, while vitamin K regulates its γ-carboxylation [15].

Numerous commercial immunoassays have been developed to quantify circulating OC levels. These include radioimmunoassay (RIA), enzyme-linked immunosorbent assay (ELISA), electrochemiluminescence immunoassays (ECLIA), chemiluminescent immunoassays (CLIA). These tests are commonly used in clinical settings because they are easy to use, fast, and efficient [16,17,18]. However, significant variability arises from preanalytical factors, the lack of international standardization, and the coexistence of both intact OC (amino acids 1–49) and its fragments, particularly the stable N-terminal/mid-region (N-MID) fragment (amino acids 1–43).

The full-length OC molecule is relatively unstable due to cleavage between amino acids 43 and 44. Although the N-MID fragment is more stable, conventional immunoassays lack the specificity to distinguish between cOC and ucOC [19]. However, these methods are insufficient for detailed proteoform analysis, particularly under metabolic conditions such as T2DM, underscoring the need for a more robust, proteoform-specific approach. Undercarboxylated OC plays an important role in the regulation of insulin secretion in pancreatic beta-cells, adiponectin expression in adipocytes, insulin sensitivity, and energy balance [20].

Given the potential role of OC proteoforms in glucose metabolism and their modulation by vit D status, characterizing these forms may provide insights into diabetes pathophysiology and support the development of improved diagnostic tools.

Therefore, developing and validating robust analytical methods is required to accurately quantify known OC variants and to examine additional proteoforms.

In clinical and routine practice, OC is usually analyzed using immunoassays that measure total OC without distinguishing the proteoforms [21]. These assays have limitations and do not measure specific OC proteoforms for metabolic disorders. Mass spectrometry-based assays for the analysis of 25-hydroxyvitamin D, steroid hormones, and parathyroid hormone have entered clinical use due to their higher specificity and lower interference [22,23,24]. The liquid chromatography–mass spectrometry method (LC-MS) may be used as an additional approach and as a possible replacement for the future of immunoassays with enhanced specificity, increased speed, expanded analyte coverage, greater throughput, multiplexing capacity, lower cost per sample, and reduced sample volume requirements [25].

At the moment, no clinically validated mass spectrometry assay is available for measuring OC proteoforms, creating a clear gap for testing. In order to address this gap, we validated a multiple reaction monitoring–mass spectrometric immunoassay (MRM-MSIA) assay to identify circulating OC proteoforms in subjects with T2DM based on their vitamin D status.

Mass spectrometric immunoassays (MSIA) have emerged as powerful tools for biomarker analysis, providing exceptional specificity and sensitivity [26]. MSIA combines the target-binding potential of immunoassays with the precision of mass spectrometry (MS). The first MSIA, developed by Nelson et al. in 1995 using matrix-assisted laser desorption/ionization (MALDI)-MS, enabled the identification of myotoxin αI via antibodies conjugated to agarose beads [27]. MSIA allows for microscale capture, identification, and quantification of target proteins. Clinically important proteoforms such as apolipoprotein A-I, apolipoprotein C-III, insulin-like growth factor 1, and amyloid A have been successfully measured using validated MSIA methods [28,29,30,31].

There is a relationship between vit D and pancreatic β-cell function. In this case, the progression of prediabetes has been related to vitamin D and its inhibitory effect on pathological progression [32]. This is because vitamin D has demonstrated potential to increase the likelihood of a normal metabolic state, an essential factor in the progression of diabetes [32]. Moreover, reports indicate that vit D reduces the risk of diabetes development by up to 15%, especially when it exceeds the normal limit for bone health [33].

Thus, the validated MSIA approach allows specific detection and characterization of distinct OC proteoforms, thereby potentially providing additional pathophysiological insight. This study aimed to characterize the various OC proteoforms in relation to vit D insufficiency in patients with T2DM and to describe an MSIA specifically developed for the identification and quantification of OC proteoforms.

Source: 1. Introduction Source: 1. Introduction Source: 1. Introduction Source: 1. Introduction Source: 1. Introduction Source: 1. Introduction Source: 1. Introduction Source: 1. Introduction Source: 1. Introduction Source: 1. Introduction

Study methods

What methods does the paper describe?

2.1. Materials and Chemicals

The anti-osteocalcin monoclonal antibody (OCG4, Cat. No. MA1-20788), modified Dulbecco’s phosphate-buffered saline (PBS, Cat. No. 28344), and PBS with Tween-20 (PBST, Cat. No. 28346) were purchased from Thermo Fisher Scientific, Waltham, MA, USA. Protein A/G 96 tips (MSIA D. A. R. T.; Cat. No. 991PRT15) and Finnipipette Novus multichannel electronic pipettes were also obtained from Thermo Scientific. All reagents and chemicals, including acetonitrile (ACN), methanol (MeOH), formic acid (FA), dithiothreitol (DTT), iodoacetamide (IAA), and ammonium bicarbonate (ABC), were purchased from Sigma-Aldrich (St.

Louis, MO, USA). Both stable isotope-labeled (13C6, 15N2-labeled lysine and 13C6, 15N4-labeled arginine) and their unlabeled counterparts were synthesized by Biomatik Corporation (Kitchener, ON, Canada).

2.2. Ethical Considerations

All procedures adhered to the ethical principles outlined in the Declaration of Helsinki and followed the guidelines established by the International Conference on Harmonization for Good Clinical Practice (ICH-GCP) [34,35]. The study was approved by the Institutional Review Board (IRB) of the College of Medicine, King Saud University (Approval No: E-16-1752). Written informed consent was obtained from all participants before their enrollment in the study.

2.3. Subjects and Sample Collection

A total of 40 patients with T2DM receiving primary care at the outpatient clinics of King Saud University Medical City were enrolled. No participants had comorbidities related to cardiovascular disease, chronic kidney disease, liver disease, thyroid disorders, active infections, malignancy, or autoimmune diseases. Blood samples were collected into EDTA tubes (BD Biosciences, San Jose, CA, USA) after a 10 h overnight fast. Plasma was separated by centrifugation at 3000× g for 15 min and stored at −80 °C for later analysis.

Routine laboratory investigations and estimations of 25 (OH) Vit D levels were carried out at the central biochemistry lab at King Khalid University Hospital, Riyadh, Saudi Arabia. The 25(OH)D levels were measured using electrochemiluminescence (ECLIA) immunoassay (Modular Analytics E170, Roche Diagnostics GmbH, Mannheim, Germany). Patients were assessed for their vit D status and categorized accordingly. Patients with serum vit D levels >75 nmol/L were classified as having T2DM with normal vit D levels (DN, n = 20), whereas those with levels <50 nmol/L were categorized as having T2DM with deficient vit D levels (DD, n = 20).

Characteristics of study participants are presented in Table S1.

2.4. Selection of Signature Peptides

The full-length protein sequence of OC from Homo sapiens (accession number P02818) was retrieved from the National Center for Biotechnology Information (NCBI) protein database. To identify potential signature peptides suitable for targeted proteomics, the sequence was subjected to in silico trypsin digestion using the PeptideMass tool (https://web.expasy.org/peptide_mass/, accessed 12 August 2024) available at the ExPASy Bioinformatics Resource Portal. Peptide specificity was confirmed using the Basic Local Alignment Search Tool (BLAST) (https://ftp.ncbi.nlm.nih.gov/blast/, accessed 12 August 2024) by comparing the sequences against other human proteins in the NCBI database.

Several criteria were applied to select optimal signature peptides. First, peptides with 5–25 amino acids were considered for efficient ionization and detection by LC-MS/MS. Second, water solubility was evaluated using PepCalc (https://pepcalc.com/, accessed 12 August, 2024Innovagen). Third, peptide stability was assessed using the ProtParam tool (http://web.expasy.org/protparam/, accessed 12 August 2024). Fourth, selected peptides were verified as OC-specific using the SIM alignment tool (https://web.expasy.org/sim/, accessed 12 August 2024) to prevent cross-reactivity. Finally, potential post-translational modifications (PTMs), including methylation, glycosylation, and phosphorylation, were screened using UniProt and Phospho.ELM databases.

Regions containing known γ-carboxylated glutamate residues were evaluated during peptide selection. Peptides containing these labile or variable post-translational modification sites were excluded to ensure analytical robustness and reproducibility in the MRM assay.

Characteristic OC peptides were identified via in silico tryptic digestion and subsequently confirmed using Skyline software v23.1. Table S2 summarizes the features of the selected OC-specific signature peptides used for quantification. Light and heavy peptide pairs served as analytes and internal standards. Each peptide pair co-eluted at identical retention times, ensuring reliable quantification. Calibration curves constructed from standard reference materials demonstrated consistent ionization efficiencies between the unknown samples and calibration standards.

2.5. MRM Transition Development

The candidate OC proteoforms were identified from LC-MS/MS data by analyzing their intact mass and fragmentation patterns. These were then aligned with recommended practices for proteoform identification and validation [36,37]. The selection was further guided by the known biological processing of OC, as documented in protein databases such as Uniprot, and by the presence or absence of PTMs on OC, specifically the γ-carboxylation and truncation variants, which are well-known [38,39]. From the different proteoforms present, only those supported by reproducible spectral data, precise mass measurements, and confident sequence assignment, adhering to current proteoform reporting standards, were retained [40].

Features lacking sufficient confidence or clear proteoform specificity were excluded from further analysis.

2.5.1. Preparation of Synthetic Peptides

Unlabeled and stable-isotope-labeled peptides corresponding to each OC proteoform were first prepared as stock solutions at a concentration of 1.0 mg/mL in water. For LC-MS/MS analysis, a working solution of each peptide was prepared by diluting the stock to a final concentration of 10.0 µg/mL in the mobile phase, which consisted of solvent A (0.1% FA in distilled water) and solvent B (0.1% FA in 50% (v/v) ACN: MeOH).

2.5.2. Liquid Chromatography–Mass Spectrometry (LC-MS/MS) Analysis

Each peptide was analyzed at a final concentration of 10.0 µg/mL using a Waters Acquity UPLC coupled to an XEVO TQ-MS operated in positive electrospray ionization (ESI) mode. Chromatographic separation employed a UHPLC BEH C18 column (1.7 µm, 2.1 × 100 mm) at a flow rate of 0.3 mL/min [41]. The gradient program started with 90% solvent A and 10% solvent B for 1 min, followed by a linear gradient over 10 min to reach 10% solvent A and 90% solvent B.

The gradient then returned to its initial condition over 3 min, resulting in a total run time of 15 min. For LC-MS/MS, adjustments were made to the overall mass spectrometry (MS) settings. MS parameters included a desolvation temperature of 450 °C, desolvation gas flow of 900 L/h, cone gas flow of 50 L/h, cone voltage of 40 V, and capillary voltage of 2 kV.

The MRM transitions for each OC peptide and their respective internal standards were optimized and chosen based on signal strength and specificity. The specific transitions used were as follows: OC-1 (327.32 > 183.133) and its labeled internal standard (417.37 > 282.16); OC-2 (412.42 > 272.194) and its labeled internal standard (417.37 > 282.16); OC-3 (837.9 > 253.1) and its labeled internal standard (840.2 > 253.02) (Table S2). These transitions were selected for their signal intensity and fragmentation patterns to enable precise quantification of the targeted proteoforms.

2.6. Sample Preparation and Enrichment Using MSIA D.A.R.Ts

Plasma samples were processed using MSIA D.A.R.Ts (Thermo Scientific, Waltham, MA, USA) according to the manufacturer’s protocol to isolate the target OC proteoforms. Novus i multichannel pipettes equipped with protein A/G MSIA™ tips were used to facilitate sample enrichment through repeated aspiration and dispensing cycles (Table S3). For each sample, plasma was diluted 10-fold in PBST. Then, 15 μL of the diluted plasma was mixed with 135 μL of 100× PBS, and the mixture was applied to the conditioned MSIA tips.

Before applying the sample, the tips were preconditioned with PBS and then loaded with 100 μL of anti-OC polyclonal antibody (0.05 mg/mL), which binds OC at epitopes 1–100. The antibody was immobilized via its interaction with protein A/G on the MSIA monolithic surface. Antigen–antibody binding enabled the selective extraction of native OC proteoforms. Four wash steps (alternating between PBS and water) were performed to remove any unbound components. Bound OC proteoforms were eluted using a buffer containing 40% ACN and 0.4% TFA in distilled water.

The eluted samples were then dried using a high-speed vacuum centrifuge and stored until LC-MS/MS analysis. A schematic of the overall MSIA workflow for IC is shown in Figure 1. Immunoaffinity capture using antibody-coated porous tips is shown in Figure S1.

2.6.1. In-Solution Tryptic Digestion

Tryptic digestion was performed by dissolving proteins in 40 μL of 50 mM ammonium bicarbonate and incubating the solution at 56 °C for 1 h with 10 mM dithiothreitol (DTT; Sigma, St. Louis, MO, USA) to reduce disulfide bonds. Proteins were then alkylated with 20 mM iodoacetamide (IAA; Sigma, St. Louis, MO, USA) at room temperature in the dark for 1 h. Subsequently, enzymatic digestion was carried out using trypsin (Promega, Madison, WI, USA) at a 1:50 (w/w) enzyme-to-substrate ratio, followed by overnight incubation at 37 °C.

The reaction was terminated by adding 7 μL of 10% FA.

2.6.2. Solid-Phase Extraction (SPE)

Tryptic peptides were purified and concentrated using solid-phase extraction (SPE), as described previously [42]. Oasis HLB 1 cc 30 mg cartridges (Waters Oasis PRiME, Waters Corporation, Milford, MA, USA) were conditioned with 100% MeOH, followed by equilibration with distilled water. Peptide samples, premixed with stable isotope-labeled internal standards and diluted in 0.1% FA in distilled water (loading buffer), were then loaded onto the SPE cartridges. Unbound substances were removed by two washes with distilled water. Finally, peptides were eluted using 1 mL of 50% ACN containing 0.1% FA.

2.7. Validation of the LC-MS/MS Method

The validation of the analytical method was conducted in accordance with the guidelines set by the United States Food and Drug Administration (US FDA) and the International Conference on Harmonization (ICH) [43,44,45,46]. Sample analysis utilized the LC-MS/MS method outlined in Section 2.5.2. All validation experiments adhered to predefined acceptance criteria and the number of replicates (n), which are detailed in the validation tables. The assay performance was summarized using standard statistical measures such as mean, SD, %CV, and % bias, as appropriate.

For LC-MS validation, precision was considered acceptable at ≤15% CV and accuracy within ±15% bias. At the lower limit of quantitation (LLOQ), acceptable limits were ≤20% CV and ±20% bias. These criteria were consistently applied to ensure a transparent and reproducible evaluation of the assay’s performance.

2.7.1. Linearity

A calibration curve was created using unlabeled peptides at concentrations from 0.1 to 1000 nM. Quality control (QC) samples were prepared at 1.5, 35, and 75 nM. Proteins from pooled plasma samples were precipitated by adding four volumes of ice-cold acetone, vortexing for 1 min, and incubating at −20 °C for 1 h. After centrifuging at 14,000× g for 15 min at 4 °C, the supernatant was discarded, and the pellet was air-dried. The pellets were resuspended in PBS and digested with trypsin to prepare the matrix.

Calibration standards and QC samples were then made by spiking synthetic peptides into this digested matrix. Before injection, each sample was diluted with 0.1% formic acid in deionized water and spiked with 20 µL of a 20 µg/mL internal standard prepared in 0.1% formic acid in a 50:50 (v/v) mixture of acetonitrile and methanol, then processed as described in Section 2.5.2. Calibration curves were built over three consecutive days, plotting the ratio of analyte to internal standard signal (y-axis) against the nominal concentration (x-axis).

Linearity was evaluated through regression analysis based on the correlation coefficient (R2), as well as precision and accuracy. Calibration curves were evaluated over three independent analytical runs (n = 3). Accuracy and precision acceptance criteria were ±15% bias and ≤15% CV, respectively.

2.7.2. Specificity and Sensitivity

Calibration curves collected over three consecutive days were used to determine the lower limit of detection (LLOD) and LLOQ. The LLOD and LLOQ were defined as concentrations with signal-to-noise (S/N) ratios of at least 3 and 10, respectively. The LLOD and LLOQ were calculated as follows: LLOD = 3.3σ/S while LLOQ = 10σ/S, where σ represents the standard deviation of the response, and S represents the slope of the calibration curve. The LLOQ was needed to demonstrate accuracy within 80–120% and precision (coefficient of variation) of 20% or less.

Specificity was evaluated by confirming that the detected signals were uniquely linked to the targeted OC proteoforms using precise mass measurements, consistent retention times, and confirmatory MS/MS fragmentation. Additionally, potential interference from endogenous background, co-eluting species, and related peptide/proteoform forms was assessed. Control and blank samples were checked to ensure that no significant interfering signals were present at the relevant retention times and m/z ranges.

2.7.3. Inter- and Intraday Validation

Precision and accuracy were evaluated at three quality control (QC) levels: low (QCL), medium (QCM), and high (QCH) using six replicate injections on the same day at concentrations of 35, 150, and 300 nM, respectively. Intraday (within-day) precision and accuracy were evaluated based on these replicates, while interday (between-day) reproducibility was determined by analyzing the same QC levels over three consecutive days under identical experimental conditions. Precision was expressed as % relative standard deviation (%RSD). Intraday accuracy was calculated as

[(mean estimated concentration on a given day)/(nominal concentration)] × 100

Interday accuracy was calculated as

[(mean concentration over 3 days)/(nominal concentration)] × 100

Acceptable accuracy criteria were defined as 80–120% for the LOQ calibrators and 85–115% for all other calibration levels.

2.7.4. Peptide Stability

QC samples (at high, medium, and low concentrations) were stored at room temperature, 4 °C, and −20 °C to evaluate peptide stability. After storage, these samples were analyzed and compared to freshly prepared QC samples. Peptide stability was calculated as [(mean area ratio of stored sample)/(mean area ratio of fresh sample)] × 100%.

2.7.5. Carryover

Carryover was evaluated by injecting three blank samples following the injection of the highest standard concentration, and this step was repeated six times to ensure consistency. Carryover was considered acceptable if a signal detected in the blank samples did not exceed 20% of the LLOQ [47].

2.8. Data and Statistical Analysis

GraphPad Prism 6.01 (La Jolla, CA, USA) was used to perform statistical comparisons of clinical variables between groups. A p-value < 0.05 was considered statistically significant. LC-MS/MS data acquisition and processing were performed using MassLynx software version 4.1 (Waters Corporation, Milford, MA, USA). All quantitative results are reported as mean ± standard deviation (SD). OC1-3 proteoform levels were compared between patients with T2DM associated with vit D deficiency and those with normal vit D levels.

Source: 2. Materials and Methods Source: 2. Materials and Methods Source: 2. Materials and Methods Source: 2. Materials and Methods Source: 2. Materials and Methods Source: 2. Materials and Methods Source: 2. Materials and Methods Source: 2. Materials and Methods

Results: Participant Characteristics

All participants had T2DM and were classified as either DN (normal vit D) or DD (vit D deficient). The mean ages of the DN and DD groups were 50.3 ± 13.2 years and 45.3 ± 10.6 years, respectively. No significant differences were observed between the groups in age or biochemical parameters (p > 0.05), whereas vit D levels were significantly different (p < 0.01).

Source: 3.1. Participant Characteristics

Results: Characteristics of Signature Peptides

Three signature peptides, 64PDPLEPRR71, 64PDPLEPR70, and 72EVCELNPDCDELADHIGFQEAY93, were selected based on the criteria in Section 2.4. These peptides were synthesized in both unlabeled and stable isotope-labeled forms. These were used to construct calibration curves and served as peptides generated in both regular and stable-isotope-labeled forms as internal standards (IS). All peptides had a purity > 95% (confirmed by HPLC) and underwent sequence confirmation. High-resolution mass spectrometry (HRMS) was employed to verify isotopic labeling sites.

The manufacturer verified the quality of the standard peptide through MS spectra and HPLC chromatograms.

Source: 3.2. Characteristics of Signature Peptides

Results: Method Validation Results

3.3.1. Establishment of Linear Curve

The quantification range and linearity for each selected OC signature peptide (aa64–71, aa64–70, and aa72–93) were established using calibration curves. The calibration curves demonstrated excellent linearity over the range of 0.5 to 1000 nM, with coefficients of determination (R2) of 0.9992, 0.9999, and 0.9949, respectively (Figure 2 and Figure 3). Table 1 shows the results of the sensitivity evaluation. The calibration curves for the three OC peptides had coefficients of determination (R2) > 0.99, confirming accurate quantification across a broad concentration range (0.5 to 1000 nM).

In addition, no significant interfering signals were observed in blank or control samples at the retention times and monitored MRM transitions corresponding to the targeted OC proteoforms, confirming the specificity of the assay.

The LLOQ was 0.5 nM for the characteristic peptides, confirmed over three days. Calibration curves for the three signature OC peptides demonstrated high linearity with R2 values of 0.9993, 0.9998, and 0.9950. No significant interference was observed in specificity testing, and blank samples showed signals below 20% of the LLOQ.

The attained LLOQ of 0.5 nM for all three OC peptides demonstrates adequate sensitivity for detecting physiological concentrations of OC fragments in plasma. Circulating OC fragment levels typically range from approximately 0.9 to 3.9 ng/mL, corresponding to ~0.16–0.76 nM, depending on assay methodology and population studied. These values often fall within the sub-nanomolar to low-nanomolar range, especially for certain OC proteoforms [48]. Consequently, the sensitivity of our technique allows accurate measurement of low-abundance osteocalcin fragments, underscoring its appropriateness for clinical diagnostic applications and proteoform-specific biomarker investigations.

Analytically, the MSIA approach offers sensitivity comparable to that of the enzyme-linked immunosorbent assay (ELISA) [49]; however, it provides significantly enhanced specificity for proteoform-resolved quantification of OC fragments.

3.3.2. Inter- and Intraday Precision

Intra- and interday variability was less than 15%, and accuracy ranged from 88.8% to 110.1% (Table 2 and Table 3), meeting ICH and FDA acceptance criteria. These results indicate minimal analytical variability and support the method’s reproducibility over multiple runs and days.

3.3.3. Peptide Stability Study

Stability testing showed peptide integrity ranging from 81.3% to 107.5% (Table S4). This suggests that the method is not only analytically reliable but also feasible for routine use in clinical laboratories, where samples may be subjected to varying storage and handling conditions.

Table 1

Linearity and sensitivity summary over three days.

Signature Peptide IDLLOQ (n = 6)Slope
(n = 3)
Intercept
(n = 3)
R2
(n = 3)
Concentration
(nM)
Inter-Day
Accuracy (%)
Inter-Day
Precision (%)
OC-10.5098.77.10.02311−0.086300.9993
OC-20.50105.32.90.04440−0.048900.9998
OC-30.50101.34.10.042890.25200.9950

OC, osteocalcin; LLOQ, Lower Limit of Quantification; R2, coefficient of determination.

Table 2

Inter-day validation summary.

Signature Peptide IDQCL 35.0 nM
(n = 6)
QCM 150.0 nM
(n = 6)
QCH 300.0 nM
(n = 6)
Mean
(nM)
SD Accuracy
%
Precision %Mean (nM) SD Accuracy %Precision
%
Mean
(nM)
SD Accuracy
%
Precision
%
OC-134.91.5799.714.5155.22.6103.471.70330.322.0110.16.7
OC-233.41.0695.43.17154.078.16102.75.3310.34.7103.41.5
OC-335.22.65100.577.5158.99.4105.95.9311.314.2103.74.6

QCL, Quality Control Low; QCM, Quality Control Medium; QCH, Quality Control High; SD, standard deviation; OC, osteocalcin.

Table 3

Intra-day validation summary.

Signature Peptide IDQCL 35.0 nM
(n = 18)
QCM 150.0 nM
(n = 18)
QCH 300.0 nM
(n = 18)
Mean (nM) SD Accuracy
%
Precision %Mean (nM) SD Accuracy
%
Precision %Mean (nM)SD Accuracy
%
Precision
%
OC-135.23.9100.711.0153.27.7102.15.0308.517.5102.85.7
OC-231.02.788.88.9159.25.0106.13.1298.515.299.55.1
OC-331.62.090.26.3147.511.498.37.7303.216.4101.15.4

QCL, Quality Control Low; QCM, Quality Control Medium; QCH, Quality Control High, SD, standard deviation, OC, osteocalcin.

Source: 3.3. Method Validation Results Source: 3.3. Method Validation Results Source: 3.3. Method Validation Results Source: 3.3. Method Validation Results Source: 3.3. Method Validation Results Source: 3.3. Method Validation Results

Evaluation of OC Variants in Clinical Samples

Results: Evaluation of OC Variants in Clinical Samples

Significantly elevated levels of OC-1 (aa64–71) were observed in patients with T2DM and vit D deficiency compared to those with normal vit D levels (p ≤ 0.01) (Figure 4A). The between-group comparison for the remaining proteoforms OC-2 and OC-3 showed no significant difference between the two groups. The ROC curve analysis for OC-1 yielded an AUC of 0.8263 (95% confidence interval [CI], p = 0.0004) (Figure 4B).

Source: 3.4. Evaluation of OC Variants in Clinical Samples

Discussion

Different OC variants have distinct clinical roles. Among the known variants that are commonly measured using immunoassays are the carboxylated and uncarboxylated OC (ucOC). Carboxylated OC is a key marker of bone health, supporting bone strength and mineralization, and ucOC is known to influence metabolic processes such as glucose and energy metabolism. Higher ucOC levels correlate with increased insulin sensitivity and a lower incidence of T2DM [50]. OC levels also monitor bone remodeling in diseases like osteoporosis, Paget’s disease, and chronic renal disease, guiding clinical management [48,51,52].

Changes in OC carboxylation and calcium coordination markedly affect its structure and biological functions [53]. Vit D deficiency is known to lower OC gene expression in osteoblasts, resulting in reduced blood OC levels [54]. It also impairs calcium absorption, which may affect OC activation [55]. Guney et al. found a positive correlation between OC and vit D levels in patients with metabolic syndrome [56]. Vit D supplementation, on the other hand, is known to increase OC levels, while decreasing ucOC levels [57].

These data suggest that vit D levels modulate the balance of OC proteoforms.

Traditional antibody-based methods for biomarker measurement are limited by their inability to differentiate proteoforms and polymorphic variants in a single assay and often face issues with stability, sensitivity, and cost [58]. Recent advances include biosensors, chemiluminescent immunoassays, and LC-MS/MS techniques that improve specificity and sensitivity [21,58,59] and identify these different proteoforms.

A previous study reported successful quantification of parathyroid hormone fragments using MRM-MSIA, demonstrating the method’s specificity and sensitivity [60]. This study is the first to apply MSIA for reliable detection and quantification of OC fragments in normal vit D and patients with T2DM, validating this approach.

OC plays a central role at the intersection of bone metabolism and systemic glucose homeostasis. It acts as a hormone, influencing insulin secretion, insulin sensitivity, and overall glucose regulation. Vitamin K-dependent carboxylation converts osteocalcin into the carboxylated form that binds hydroxyapatite and supports mineralization, and the carboxylation status has been associated with type 2 diabetes in recent population studies [61]. On the other hand, ucOC exhibits endocrine activity and is the active form in glucose metabolism. It enhances insulin secretion, β-cell proliferation, and insulin sensitivity stimulating insulin secretion potentially improving insulin sensitivity in muscle and adipose tissue [62].

Similarly, vit D is essential for OC synthesis and carboxylation in osteoblasts, and its deficiency may disrupt these processes, leading to altered levels and functionality of circulating osteocalcin. In diabetes, impaired bone turnover and oxidative stress further affect osteocalcin expression and processing [63]. The mechanistic basis for a vitamin D influence on osteocalcin is reinforced by interventional evidence. In a randomized, double-blind trial in patients with type 2 diabetes mellitus, supplementation with vitamin D3 significantly reduced circulating undercarboxylated osteocalcin and lowered the undercarboxylated-to-carboxylated ratio, whereas vitamin K2 raised the carboxylated form [64].

This indicates that vitamin D status actively shapes the balance of osteocalcin species rather than merely correlating with total concentrations, and it provides a plausible framework for interpreting the altered osteocalcin profile observed in our vitamin D–deficient cohort. The combination of vit D deficiency and diabetes creates a unique biochemical environment that shifts OC proteoform balance, potentially influencing both bone remodeling and metabolic regulation. Our findings of altered OC-1 levels in this context may reflect such underlying pathophysiological changes. This study demonstrates, for the first time, the application of MSIA-LC-MS/MS to detect and quantify OC proteoforms in T2DM patients with vit D deficiency, offering high specificity and sensitivity over traditional immunoassays that can only distinguish between carboxylated and undercarboxylated OC.

These findings suggest the potential utility of OC proteoform profiling in assessing vit D status and metabolic dysfunction in T2DM.

The observed elevation of the proteoform OC-1 (aa64–71) in vit D-deficient T2DM patients may reflect a shift in osteocalcin processing, likely influenced by dysregulated bone remodeling. One possible explanation is enhanced proteolytic cleavage at the C-terminal region, potentially mediated by vit D-regulated enzymes such as matrix metalloproteinases or cathepsin K. Alternatively, OC-1 may exhibit greater biochemical stability or resistance to further degradation compared to other overlapping fragments, contributing to its increased abundance. The findings from our study may suggest that vit D deficiency may alter the balance of OC proteoforms, with potential implications for bone–metabolism cross-talk in metabolic disease.

Key strengths of the study include the use of stable isotope-labeled peptides, rigorous validation using standard reference materials, and peptide-level quantification, which addresses limitations of antibody cross-reactivity. However, limitations include a relatively small sample size, lack of longitudinal data, the absence of formal evaluation of matrix effects and recovery, and the requirement for specialized equipment and technical expertise, which may constrain broader clinical adoption. Limitation of MRM include that accuracy can be impacted by factors such as the quality of peptide selection, digestion efficiency, sample processing consistency, and potential interference from matrix effects or co-eluting compounds.

MSIA is also limited by challenges such as experimental complexity, low signal intensity in MS, and the restricted availability of high-quality antibodies [65]. Future studies involving larger, diverse cohorts and therapeutic monitoring, such as vit D supplementation, are warranted to further validate clinical applicability and explore the prognostic value of specific OC proteoforms in metabolic and bone disorders.

Source: 4. Discussion Source: 4. Discussion Source: 4. Discussion Source: 4. Discussion Source: 4. Discussion Source: 4. Discussion

Results

3.1. Participant Characteristics

All participants had T2DM and were classified as either DN (normal vit D) or DD (vit D deficient). The mean ages of the DN and DD groups were 50.3 ± 13.2 years and 45.3 ± 10.6 years, respectively. No significant differences were observed between the groups in age or biochemical parameters (p > 0.05), whereas vit D levels were significantly different (p < 0.01).

3.2. Characteristics of Signature Peptides

Three signature peptides, 64PDPLEPRR71, 64PDPLEPR70, and 72EVCELNPDCDELADHIGFQEAY93, were selected based on the criteria in Section 2.4. These peptides were synthesized in both unlabeled and stable isotope-labeled forms. These were used to construct calibration curves and served as peptides generated in both regular and stable-isotope-labeled forms as internal standards (IS). All peptides had a purity > 95% (confirmed by HPLC) and underwent sequence confirmation. High-resolution mass spectrometry (HRMS) was employed to verify isotopic labeling sites.

The manufacturer verified the quality of the standard peptide through MS spectra and HPLC chromatograms.

3.3. Method Validation Results

3.3.1. Establishment of Linear Curve

The quantification range and linearity for each selected OC signature peptide (aa64–71, aa64–70, and aa72–93) were established using calibration curves. The calibration curves demonstrated excellent linearity over the range of 0.5 to 1000 nM, with coefficients of determination (R2) of 0.9992, 0.9999, and 0.9949, respectively (Figure 2 and Figure 3). Table 1 shows the results of the sensitivity evaluation. The calibration curves for the three OC peptides had coefficients of determination (R2) > 0.99, confirming accurate quantification across a broad concentration range (0.5 to 1000 nM).

In addition, no significant interfering signals were observed in blank or control samples at the retention times and monitored MRM transitions corresponding to the targeted OC proteoforms, confirming the specificity of the assay.

The LLOQ was 0.5 nM for the characteristic peptides, confirmed over three days. Calibration curves for the three signature OC peptides demonstrated high linearity with R2 values of 0.9993, 0.9998, and 0.9950. No significant interference was observed in specificity testing, and blank samples showed signals below 20% of the LLOQ.

The attained LLOQ of 0.5 nM for all three OC peptides demonstrates adequate sensitivity for detecting physiological concentrations of OC fragments in plasma. Circulating OC fragment levels typically range from approximately 0.9 to 3.9 ng/mL, corresponding to ~0.16–0.76 nM, depending on assay methodology and population studied. These values often fall within the sub-nanomolar to low-nanomolar range, especially for certain OC proteoforms [48]. Consequently, the sensitivity of our technique allows accurate measurement of low-abundance osteocalcin fragments, underscoring its appropriateness for clinical diagnostic applications and proteoform-specific biomarker investigations.

Analytically, the MSIA approach offers sensitivity comparable to that of the enzyme-linked immunosorbent assay (ELISA) [49]; however, it provides significantly enhanced specificity for proteoform-resolved quantification of OC fragments.

3.3.2. Inter- and Intraday Precision

Intra- and interday variability was less than 15%, and accuracy ranged from 88.8% to 110.1% (Table 2 and Table 3), meeting ICH and FDA acceptance criteria. These results indicate minimal analytical variability and support the method’s reproducibility over multiple runs and days.

3.3.3. Peptide Stability Study

Stability testing showed peptide integrity ranging from 81.3% to 107.5% (Table S4). This suggests that the method is not only analytically reliable but also feasible for routine use in clinical laboratories, where samples may be subjected to varying storage and handling conditions.

3.4. Evaluation of OC Variants in Clinical Samples

Significantly elevated levels of OC-1 (aa64–71) were observed in patients with T2DM and vit D deficiency compared to those with normal vit D levels (p ≤ 0.01) (Figure 4A). The between-group comparison for the remaining proteoforms OC-2 and OC-3 showed no significant difference between the two groups. The ROC curve analysis for OC-1 yielded an AUC of 0.8263 (95% confidence interval [CI], p = 0.0004) (Figure 4B).

Table 1

Linearity and sensitivity summary over three days.

Signature Peptide IDLLOQ (n = 6)Slope
(n = 3)
Intercept
(n = 3)
R2
(n = 3)
Concentration
(nM)
Inter-Day
Accuracy (%)
Inter-Day
Precision (%)
OC-10.5098.77.10.02311−0.086300.9993
OC-20.50105.32.90.04440−0.048900.9998
OC-30.50101.34.10.042890.25200.9950

OC, osteocalcin; LLOQ, Lower Limit of Quantification; R2, coefficient of determination.

Table 2

Inter-day validation summary.

Signature Peptide IDQCL 35.0 nM
(n = 6)
QCM 150.0 nM
(n = 6)
QCH 300.0 nM
(n = 6)
Mean
(nM)
SD Accuracy
%
Precision %Mean (nM) SD Accuracy %Precision
%
Mean
(nM)
SD Accuracy
%
Precision
%
OC-134.91.5799.714.5155.22.6103.471.70330.322.0110.16.7
OC-233.41.0695.43.17154.078.16102.75.3310.34.7103.41.5
OC-335.22.65100.577.5158.99.4105.95.9311.314.2103.74.6

QCL, Quality Control Low; QCM, Quality Control Medium; QCH, Quality Control High; SD, standard deviation; OC, osteocalcin.

Table 3

Intra-day validation summary.

Signature Peptide IDQCL 35.0 nM
(n = 18)
QCM 150.0 nM
(n = 18)
QCH 300.0 nM
(n = 18)
Mean (nM) SD Accuracy
%
Precision %Mean (nM) SD Accuracy
%
Precision %Mean (nM)SD Accuracy
%
Precision
%
OC-135.23.9100.711.0153.27.7102.15.0308.517.5102.85.7
OC-231.02.788.88.9159.25.0106.13.1298.515.299.55.1
OC-331.62.090.26.3147.511.498.37.7303.216.4101.15.4

QCL, Quality Control Low; QCM, Quality Control Medium; QCH, Quality Control High, SD, standard deviation, OC, osteocalcin.

Source: 3. Results Source: 3. Results Source: 3. Results Source: 3. Results Source: 3. Results Source: 3. Results Source: 3. Results

Conclusions

The multiple reaction monitoring–mass spectrometric immunoassay (MRM-MSIA) assay has proven to be useful in the quantitation of OC proteoforms as it demonstrated good analytical performance characterized by low LLOD and LLOQ, good precision, reproducibility, stability, and recovery. The results highlight the substantial potential of OC proteoforms as potential biomarkers for monitoring in patients with T2DM and vit D deficiency. Additionally, further investigation is warranted to establish a definitive relationship between vit D supplementation and the distribution of OC proteoforms.

Source: 5. Conclusions
Authors’ abstract

Osteocalcin (OC), a bone protein, is evaluated by its proteoforms, which are implicated in various illnesses. Rapid, clinically used immunoassays are well-established. Epitope dependence, fragment cross-reactivity, uneven identification across carboxylation states, and lack of standardization restrict their efficacy. This study aims to characterize various OC proteoforms in patients with type 2 diabetes mellitus (T2DM) and vitamin D insufficiency and to develop a mass spectrometric immunoassay (MSIA) for their detection. The first MRM-MSIA test to specifically detect OC proteoforms in plasma with vitamin D deficiency-induced alterations in T2DM patients was developed and validated.

A precise and selective MRM-MSIA was developed to assess OC fragments in plasma from T2DM patients with normal (DN) or deficient (DD) vitamin D levels. The approach examined OC-1 (aa64–71), OC-2 (aa64–70), and OC-3 (aa72–93) proteoforms. It met international linearity, precision, and accuracy criteria with variability <15% and intra/inter-day accuracy of 88.8% to 110.1%. The DD group had significantly higher OC-1 levels than the DN group. The receiver operating characteristic (ROC) curve for OC-1 produced an AUC of 0.8263 (95% confidence interval [CI], p = 0.0004).

The developed MRM-MSIA measures plasma OC proteoforms with good specificity and sensitivity, making it a promising clinical diagnostic tool.

Read the full paper

1. Introduction

Osteocalcin (OC), also known as bone gamma-carboxyglutamic acid (Gla) protein (BGP), is a 5.7 kDa peptide comprising 49 amino acids. It is synthesized by osteoblasts and is the most abundant noncollagenous protein in the bone matrix [1]. OC is initially produced as a 98-amino-acid pre-pro-protein, which undergoes proteolytic processing to yield the mature form. This mature OC, called carboxylated OC (cOC), binds strongly to bone and the extracellular matrix. It undergoes γ-carboxylation at three glutamic acid residues (positions 17, 21, and 24) by the enzyme γ-glutamyl carboxylase.

Alongside vit D (vit D), OC was originally postulated to function in extracellular matrix mineralization and has been employed as a circulating biomarker of osteoblastic bone formation [2,3].

In recent years, studies have highlighted the involvement of both vit D and OC in insulin resistance and the development of metabolic diseases such as type 2 diabetes mellitus (T2DM) [4,5,6]. Uncarboxylated OC (ucOC) has been shown to stimulate insulin secretion from pancreatic islets and plays a key role in glucose homeostasis [7].

Deficiency of vit D is common worldwide, particularly among individuals suffering from T2DM. Recent studies have shown that more than 50% of patients with T2DM are suffering from vit D deficiency [8,9]. Furthermore, vit D adequacy is important for better glycemic control, particularly in vulnerable populations or individuals who have vitamin D deficiency. These findings highlight the strong link between low vit D status and glucose metabolism, and the significance of the investigation of vit D-based biomarkers and the interrelation between vit D and OC in diabetes [10].

OC levels have been associated with serum 25-hydroxyvitamin D [25(OH)D] concentrations, which are frequently reduced in individuals who are overweight or at elevated risk for developing T2DM [11]. Vit D status is typically classified as deficient when levels are <50 nmol/L, insufficient between 50 and 70 nmol/L, and sufficient when >75 nmol/L [12].

The γ-carboxylated residues of OC are essential for calcium binding. However, under the acidic conditions of osteoclast resorption compartments, OC undergoes decarboxylation, reducing its bone-binding affinity and promoting the release of ucOC into the bloodstream [13]. In addition to the intact protein, multiple OC fragments are present in the bloodstream [14]. Vit D directly increases OC gene transcription via a vit D responsive element, while vitamin K regulates its γ-carboxylation [15].

Numerous commercial immunoassays have been developed to quantify circulating OC levels. These include radioimmunoassay (RIA), enzyme-linked immunosorbent assay (ELISA), electrochemiluminescence immunoassays (ECLIA), chemiluminescent immunoassays (CLIA). These tests are commonly used in clinical settings because they are easy to use, fast, and efficient [16,17,18]. However, significant variability arises from preanalytical factors, the lack of international standardization, and the coexistence of both intact OC (amino acids 1–49) and its fragments, particularly the stable N-terminal/mid-region (N-MID) fragment (amino acids 1–43).

The full-length OC molecule is relatively unstable due to cleavage between amino acids 43 and 44. Although the N-MID fragment is more stable, conventional immunoassays lack the specificity to distinguish between cOC and ucOC [19]. However, these methods are insufficient for detailed proteoform analysis, particularly under metabolic conditions such as T2DM, underscoring the need for a more robust, proteoform-specific approach. Undercarboxylated OC plays an important role in the regulation of insulin secretion in pancreatic beta-cells, adiponectin expression in adipocytes, insulin sensitivity, and energy balance [20].

Given the potential role of OC proteoforms in glucose metabolism and their modulation by vit D status, characterizing these forms may provide insights into diabetes pathophysiology and support the development of improved diagnostic tools.

Therefore, developing and validating robust analytical methods is required to accurately quantify known OC variants and to examine additional proteoforms.

In clinical and routine practice, OC is usually analyzed using immunoassays that measure total OC without distinguishing the proteoforms [21]. These assays have limitations and do not measure specific OC proteoforms for metabolic disorders. Mass spectrometry-based assays for the analysis of 25-hydroxyvitamin D, steroid hormones, and parathyroid hormone have entered clinical use due to their higher specificity and lower interference [22,23,24]. The liquid chromatography–mass spectrometry method (LC-MS) may be used as an additional approach and as a possible replacement for the future of immunoassays with enhanced specificity, increased speed, expanded analyte coverage, greater throughput, multiplexing capacity, lower cost per sample, and reduced sample volume requirements [25].

At the moment, no clinically validated mass spectrometry assay is available for measuring OC proteoforms, creating a clear gap for testing. In order to address this gap, we validated a multiple reaction monitoring–mass spectrometric immunoassay (MRM-MSIA) assay to identify circulating OC proteoforms in subjects with T2DM based on their vitamin D status.

Mass spectrometric immunoassays (MSIA) have emerged as powerful tools for biomarker analysis, providing exceptional specificity and sensitivity [26]. MSIA combines the target-binding potential of immunoassays with the precision of mass spectrometry (MS). The first MSIA, developed by Nelson et al. in 1995 using matrix-assisted laser desorption/ionization (MALDI)-MS, enabled the identification of myotoxin αI via antibodies conjugated to agarose beads [27]. MSIA allows for microscale capture, identification, and quantification of target proteins. Clinically important proteoforms such as apolipoprotein A-I, apolipoprotein C-III, insulin-like growth factor 1, and amyloid A have been successfully measured using validated MSIA methods [28,29,30,31].

There is a relationship between vit D and pancreatic β-cell function. In this case, the progression of prediabetes has been related to vitamin D and its inhibitory effect on pathological progression [32]. This is because vitamin D has demonstrated potential to increase the likelihood of a normal metabolic state, an essential factor in the progression of diabetes [32]. Moreover, reports indicate that vit D reduces the risk of diabetes development by up to 15%, especially when it exceeds the normal limit for bone health [33].

Thus, the validated MSIA approach allows specific detection and characterization of distinct OC proteoforms, thereby potentially providing additional pathophysiological insight. This study aimed to characterize the various OC proteoforms in relation to vit D insufficiency in patients with T2DM and to describe an MSIA specifically developed for the identification and quantification of OC proteoforms.

2. Materials and Methods

2.1. Materials and Chemicals

The anti-osteocalcin monoclonal antibody (OCG4, Cat. No. MA1-20788), modified Dulbecco’s phosphate-buffered saline (PBS, Cat. No. 28344), and PBS with Tween-20 (PBST, Cat. No. 28346) were purchased from Thermo Fisher Scientific, Waltham, MA, USA. Protein A/G 96 tips (MSIA D. A. R. T.; Cat. No. 991PRT15) and Finnipipette Novus multichannel electronic pipettes were also obtained from Thermo Scientific. All reagents and chemicals, including acetonitrile (ACN), methanol (MeOH), formic acid (FA), dithiothreitol (DTT), iodoacetamide (IAA), and ammonium bicarbonate (ABC), were purchased from Sigma-Aldrich (St.

Louis, MO, USA). Both stable isotope-labeled (13C6, 15N2-labeled lysine and 13C6, 15N4-labeled arginine) and their unlabeled counterparts were synthesized by Biomatik Corporation (Kitchener, ON, Canada).

2.2. Ethical Considerations

All procedures adhered to the ethical principles outlined in the Declaration of Helsinki and followed the guidelines established by the International Conference on Harmonization for Good Clinical Practice (ICH-GCP) [34,35]. The study was approved by the Institutional Review Board (IRB) of the College of Medicine, King Saud University (Approval No: E-16-1752). Written informed consent was obtained from all participants before their enrollment in the study.

2.3. Subjects and Sample Collection

A total of 40 patients with T2DM receiving primary care at the outpatient clinics of King Saud University Medical City were enrolled. No participants had comorbidities related to cardiovascular disease, chronic kidney disease, liver disease, thyroid disorders, active infections, malignancy, or autoimmune diseases. Blood samples were collected into EDTA tubes (BD Biosciences, San Jose, CA, USA) after a 10 h overnight fast. Plasma was separated by centrifugation at 3000× g for 15 min and stored at −80 °C for later analysis.

Routine laboratory investigations and estimations of 25 (OH) Vit D levels were carried out at the central biochemistry lab at King Khalid University Hospital, Riyadh, Saudi Arabia. The 25(OH)D levels were measured using electrochemiluminescence (ECLIA) immunoassay (Modular Analytics E170, Roche Diagnostics GmbH, Mannheim, Germany). Patients were assessed for their vit D status and categorized accordingly. Patients with serum vit D levels >75 nmol/L were classified as having T2DM with normal vit D levels (DN, n = 20), whereas those with levels <50 nmol/L were categorized as having T2DM with deficient vit D levels (DD, n = 20).

Characteristics of study participants are presented in Table S1.

2.4. Selection of Signature Peptides

The full-length protein sequence of OC from Homo sapiens (accession number P02818) was retrieved from the National Center for Biotechnology Information (NCBI) protein database. To identify potential signature peptides suitable for targeted proteomics, the sequence was subjected to in silico trypsin digestion using the PeptideMass tool (https://web.expasy.org/peptide_mass/, accessed 12 August 2024) available at the ExPASy Bioinformatics Resource Portal. Peptide specificity was confirmed using the Basic Local Alignment Search Tool (BLAST) (https://ftp.ncbi.nlm.nih.gov/blast/, accessed 12 August 2024) by comparing the sequences against other human proteins in the NCBI database.

Several criteria were applied to select optimal signature peptides. First, peptides with 5–25 amino acids were considered for efficient ionization and detection by LC-MS/MS. Second, water solubility was evaluated using PepCalc (https://pepcalc.com/, accessed 12 August, 2024Innovagen). Third, peptide stability was assessed using the ProtParam tool (http://web.expasy.org/protparam/, accessed 12 August 2024). Fourth, selected peptides were verified as OC-specific using the SIM alignment tool (https://web.expasy.org/sim/, accessed 12 August 2024) to prevent cross-reactivity. Finally, potential post-translational modifications (PTMs), including methylation, glycosylation, and phosphorylation, were screened using UniProt and Phospho.ELM databases.

Regions containing known γ-carboxylated glutamate residues were evaluated during peptide selection. Peptides containing these labile or variable post-translational modification sites were excluded to ensure analytical robustness and reproducibility in the MRM assay.

Characteristic OC peptides were identified via in silico tryptic digestion and subsequently confirmed using Skyline software v23.1. Table S2 summarizes the features of the selected OC-specific signature peptides used for quantification. Light and heavy peptide pairs served as analytes and internal standards. Each peptide pair co-eluted at identical retention times, ensuring reliable quantification. Calibration curves constructed from standard reference materials demonstrated consistent ionization efficiencies between the unknown samples and calibration standards.

2.5. MRM Transition Development

The candidate OC proteoforms were identified from LC-MS/MS data by analyzing their intact mass and fragmentation patterns. These were then aligned with recommended practices for proteoform identification and validation [36,37]. The selection was further guided by the known biological processing of OC, as documented in protein databases such as Uniprot, and by the presence or absence of PTMs on OC, specifically the γ-carboxylation and truncation variants, which are well-known [38,39]. From the different proteoforms present, only those supported by reproducible spectral data, precise mass measurements, and confident sequence assignment, adhering to current proteoform reporting standards, were retained [40].

Features lacking sufficient confidence or clear proteoform specificity were excluded from further analysis.

2.5.1. Preparation of Synthetic Peptides

Unlabeled and stable-isotope-labeled peptides corresponding to each OC proteoform were first prepared as stock solutions at a concentration of 1.0 mg/mL in water. For LC-MS/MS analysis, a working solution of each peptide was prepared by diluting the stock to a final concentration of 10.0 µg/mL in the mobile phase, which consisted of solvent A (0.1% FA in distilled water) and solvent B (0.1% FA in 50% (v/v) ACN: MeOH).

2.5.2. Liquid Chromatography–Mass Spectrometry (LC-MS/MS) Analysis

Each peptide was analyzed at a final concentration of 10.0 µg/mL using a Waters Acquity UPLC coupled to an XEVO TQ-MS operated in positive electrospray ionization (ESI) mode. Chromatographic separation employed a UHPLC BEH C18 column (1.7 µm, 2.1 × 100 mm) at a flow rate of 0.3 mL/min [41]. The gradient program started with 90% solvent A and 10% solvent B for 1 min, followed by a linear gradient over 10 min to reach 10% solvent A and 90% solvent B.

The gradient then returned to its initial condition over 3 min, resulting in a total run time of 15 min. For LC-MS/MS, adjustments were made to the overall mass spectrometry (MS) settings. MS parameters included a desolvation temperature of 450 °C, desolvation gas flow of 900 L/h, cone gas flow of 50 L/h, cone voltage of 40 V, and capillary voltage of 2 kV.

The MRM transitions for each OC peptide and their respective internal standards were optimized and chosen based on signal strength and specificity. The specific transitions used were as follows: OC-1 (327.32 > 183.133) and its labeled internal standard (417.37 > 282.16); OC-2 (412.42 > 272.194) and its labeled internal standard (417.37 > 282.16); OC-3 (837.9 > 253.1) and its labeled internal standard (840.2 > 253.02) (Table S2). These transitions were selected for their signal intensity and fragmentation patterns to enable precise quantification of the targeted proteoforms.

2.6. Sample Preparation and Enrichment Using MSIA D.A.R.Ts

Plasma samples were processed using MSIA D.A.R.Ts (Thermo Scientific, Waltham, MA, USA) according to the manufacturer’s protocol to isolate the target OC proteoforms. Novus i multichannel pipettes equipped with protein A/G MSIA™ tips were used to facilitate sample enrichment through repeated aspiration and dispensing cycles (Table S3). For each sample, plasma was diluted 10-fold in PBST. Then, 15 μL of the diluted plasma was mixed with 135 μL of 100× PBS, and the mixture was applied to the conditioned MSIA tips.

Before applying the sample, the tips were preconditioned with PBS and then loaded with 100 μL of anti-OC polyclonal antibody (0.05 mg/mL), which binds OC at epitopes 1–100. The antibody was immobilized via its interaction with protein A/G on the MSIA monolithic surface. Antigen–antibody binding enabled the selective extraction of native OC proteoforms. Four wash steps (alternating between PBS and water) were performed to remove any unbound components. Bound OC proteoforms were eluted using a buffer containing 40% ACN and 0.4% TFA in distilled water.

The eluted samples were then dried using a high-speed vacuum centrifuge and stored until LC-MS/MS analysis. A schematic of the overall MSIA workflow for IC is shown in Figure 1. Immunoaffinity capture using antibody-coated porous tips is shown in Figure S1.

2.6.1. In-Solution Tryptic Digestion

Tryptic digestion was performed by dissolving proteins in 40 μL of 50 mM ammonium bicarbonate and incubating the solution at 56 °C for 1 h with 10 mM dithiothreitol (DTT; Sigma, St. Louis, MO, USA) to reduce disulfide bonds. Proteins were then alkylated with 20 mM iodoacetamide (IAA; Sigma, St. Louis, MO, USA) at room temperature in the dark for 1 h. Subsequently, enzymatic digestion was carried out using trypsin (Promega, Madison, WI, USA) at a 1:50 (w/w) enzyme-to-substrate ratio, followed by overnight incubation at 37 °C.

The reaction was terminated by adding 7 μL of 10% FA.

2.6.2. Solid-Phase Extraction (SPE)

Tryptic peptides were purified and concentrated using solid-phase extraction (SPE), as described previously [42]. Oasis HLB 1 cc 30 mg cartridges (Waters Oasis PRiME, Waters Corporation, Milford, MA, USA) were conditioned with 100% MeOH, followed by equilibration with distilled water. Peptide samples, premixed with stable isotope-labeled internal standards and diluted in 0.1% FA in distilled water (loading buffer), were then loaded onto the SPE cartridges. Unbound substances were removed by two washes with distilled water. Finally, peptides were eluted using 1 mL of 50% ACN containing 0.1% FA.

2.7. Validation of the LC-MS/MS Method

The validation of the analytical method was conducted in accordance with the guidelines set by the United States Food and Drug Administration (US FDA) and the International Conference on Harmonization (ICH) [43,44,45,46]. Sample analysis utilized the LC-MS/MS method outlined in Section 2.5.2. All validation experiments adhered to predefined acceptance criteria and the number of replicates (n), which are detailed in the validation tables. The assay performance was summarized using standard statistical measures such as mean, SD, %CV, and % bias, as appropriate.

For LC-MS validation, precision was considered acceptable at ≤15% CV and accuracy within ±15% bias. At the lower limit of quantitation (LLOQ), acceptable limits were ≤20% CV and ±20% bias. These criteria were consistently applied to ensure a transparent and reproducible evaluation of the assay’s performance.

2.7.1. Linearity

A calibration curve was created using unlabeled peptides at concentrations from 0.1 to 1000 nM. Quality control (QC) samples were prepared at 1.5, 35, and 75 nM. Proteins from pooled plasma samples were precipitated by adding four volumes of ice-cold acetone, vortexing for 1 min, and incubating at −20 °C for 1 h. After centrifuging at 14,000× g for 15 min at 4 °C, the supernatant was discarded, and the pellet was air-dried. The pellets were resuspended in PBS and digested with trypsin to prepare the matrix.

Calibration standards and QC samples were then made by spiking synthetic peptides into this digested matrix. Before injection, each sample was diluted with 0.1% formic acid in deionized water and spiked with 20 µL of a 20 µg/mL internal standard prepared in 0.1% formic acid in a 50:50 (v/v) mixture of acetonitrile and methanol, then processed as described in Section 2.5.2. Calibration curves were built over three consecutive days, plotting the ratio of analyte to internal standard signal (y-axis) against the nominal concentration (x-axis).

Linearity was evaluated through regression analysis based on the correlation coefficient (R2), as well as precision and accuracy. Calibration curves were evaluated over three independent analytical runs (n = 3). Accuracy and precision acceptance criteria were ±15% bias and ≤15% CV, respectively.

2.7.2. Specificity and Sensitivity

Calibration curves collected over three consecutive days were used to determine the lower limit of detection (LLOD) and LLOQ. The LLOD and LLOQ were defined as concentrations with signal-to-noise (S/N) ratios of at least 3 and 10, respectively. The LLOD and LLOQ were calculated as follows: LLOD = 3.3σ/S while LLOQ = 10σ/S, where σ represents the standard deviation of the response, and S represents the slope of the calibration curve. The LLOQ was needed to demonstrate accuracy within 80–120% and precision (coefficient of variation) of 20% or less.

Specificity was evaluated by confirming that the detected signals were uniquely linked to the targeted OC proteoforms using precise mass measurements, consistent retention times, and confirmatory MS/MS fragmentation. Additionally, potential interference from endogenous background, co-eluting species, and related peptide/proteoform forms was assessed. Control and blank samples were checked to ensure that no significant interfering signals were present at the relevant retention times and m/z ranges.

2.7.3. Inter- and Intraday Validation

Precision and accuracy were evaluated at three quality control (QC) levels: low (QCL), medium (QCM), and high (QCH) using six replicate injections on the same day at concentrations of 35, 150, and 300 nM, respectively. Intraday (within-day) precision and accuracy were evaluated based on these replicates, while interday (between-day) reproducibility was determined by analyzing the same QC levels over three consecutive days under identical experimental conditions. Precision was expressed as % relative standard deviation (%RSD). Intraday accuracy was calculated as

[(mean estimated concentration on a given day)/(nominal concentration)] × 100

Interday accuracy was calculated as

[(mean concentration over 3 days)/(nominal concentration)] × 100

Acceptable accuracy criteria were defined as 80–120% for the LOQ calibrators and 85–115% for all other calibration levels.

2.7.4. Peptide Stability

QC samples (at high, medium, and low concentrations) were stored at room temperature, 4 °C, and −20 °C to evaluate peptide stability. After storage, these samples were analyzed and compared to freshly prepared QC samples. Peptide stability was calculated as [(mean area ratio of stored sample)/(mean area ratio of fresh sample)] × 100%.

2.7.5. Carryover

Carryover was evaluated by injecting three blank samples following the injection of the highest standard concentration, and this step was repeated six times to ensure consistency. Carryover was considered acceptable if a signal detected in the blank samples did not exceed 20% of the LLOQ [47].

2.8. Data and Statistical Analysis

GraphPad Prism 6.01 (La Jolla, CA, USA) was used to perform statistical comparisons of clinical variables between groups. A p-value < 0.05 was considered statistically significant. LC-MS/MS data acquisition and processing were performed using MassLynx software version 4.1 (Waters Corporation, Milford, MA, USA). All quantitative results are reported as mean ± standard deviation (SD). OC1-3 proteoform levels were compared between patients with T2DM associated with vit D deficiency and those with normal vit D levels.

3. Results

3.1. Participant Characteristics

All participants had T2DM and were classified as either DN (normal vit D) or DD (vit D deficient). The mean ages of the DN and DD groups were 50.3 ± 13.2 years and 45.3 ± 10.6 years, respectively. No significant differences were observed between the groups in age or biochemical parameters (p > 0.05), whereas vit D levels were significantly different (p < 0.01).

3.2. Characteristics of Signature Peptides

Three signature peptides, 64PDPLEPRR71, 64PDPLEPR70, and 72EVCELNPDCDELADHIGFQEAY93, were selected based on the criteria in Section 2.4. These peptides were synthesized in both unlabeled and stable isotope-labeled forms. These were used to construct calibration curves and served as peptides generated in both regular and stable-isotope-labeled forms as internal standards (IS). All peptides had a purity > 95% (confirmed by HPLC) and underwent sequence confirmation. High-resolution mass spectrometry (HRMS) was employed to verify isotopic labeling sites.

The manufacturer verified the quality of the standard peptide through MS spectra and HPLC chromatograms.

3.3. Method Validation Results

3.3.1. Establishment of Linear Curve

The quantification range and linearity for each selected OC signature peptide (aa64–71, aa64–70, and aa72–93) were established using calibration curves. The calibration curves demonstrated excellent linearity over the range of 0.5 to 1000 nM, with coefficients of determination (R2) of 0.9992, 0.9999, and 0.9949, respectively (Figure 2 and Figure 3). Table 1 shows the results of the sensitivity evaluation. The calibration curves for the three OC peptides had coefficients of determination (R2) > 0.99, confirming accurate quantification across a broad concentration range (0.5 to 1000 nM).

In addition, no significant interfering signals were observed in blank or control samples at the retention times and monitored MRM transitions corresponding to the targeted OC proteoforms, confirming the specificity of the assay.

The LLOQ was 0.5 nM for the characteristic peptides, confirmed over three days. Calibration curves for the three signature OC peptides demonstrated high linearity with R2 values of 0.9993, 0.9998, and 0.9950. No significant interference was observed in specificity testing, and blank samples showed signals below 20% of the LLOQ.

The attained LLOQ of 0.5 nM for all three OC peptides demonstrates adequate sensitivity for detecting physiological concentrations of OC fragments in plasma. Circulating OC fragment levels typically range from approximately 0.9 to 3.9 ng/mL, corresponding to ~0.16–0.76 nM, depending on assay methodology and population studied. These values often fall within the sub-nanomolar to low-nanomolar range, especially for certain OC proteoforms [48]. Consequently, the sensitivity of our technique allows accurate measurement of low-abundance osteocalcin fragments, underscoring its appropriateness for clinical diagnostic applications and proteoform-specific biomarker investigations.

Analytically, the MSIA approach offers sensitivity comparable to that of the enzyme-linked immunosorbent assay (ELISA) [49]; however, it provides significantly enhanced specificity for proteoform-resolved quantification of OC fragments.

3.3.2. Inter- and Intraday Precision

Intra- and interday variability was less than 15%, and accuracy ranged from 88.8% to 110.1% (Table 2 and Table 3), meeting ICH and FDA acceptance criteria. These results indicate minimal analytical variability and support the method’s reproducibility over multiple runs and days.

3.3.3. Peptide Stability Study

Stability testing showed peptide integrity ranging from 81.3% to 107.5% (Table S4). This suggests that the method is not only analytically reliable but also feasible for routine use in clinical laboratories, where samples may be subjected to varying storage and handling conditions.

3.4. Evaluation of OC Variants in Clinical Samples

Significantly elevated levels of OC-1 (aa64–71) were observed in patients with T2DM and vit D deficiency compared to those with normal vit D levels (p ≤ 0.01) (Figure 4A). The between-group comparison for the remaining proteoforms OC-2 and OC-3 showed no significant difference between the two groups. The ROC curve analysis for OC-1 yielded an AUC of 0.8263 (95% confidence interval [CI], p = 0.0004) (Figure 4B).

4. Discussion

Different OC variants have distinct clinical roles. Among the known variants that are commonly measured using immunoassays are the carboxylated and uncarboxylated OC (ucOC). Carboxylated OC is a key marker of bone health, supporting bone strength and mineralization, and ucOC is known to influence metabolic processes such as glucose and energy metabolism. Higher ucOC levels correlate with increased insulin sensitivity and a lower incidence of T2DM [50]. OC levels also monitor bone remodeling in diseases like osteoporosis, Paget’s disease, and chronic renal disease, guiding clinical management [48,51,52].

Changes in OC carboxylation and calcium coordination markedly affect its structure and biological functions [53]. Vit D deficiency is known to lower OC gene expression in osteoblasts, resulting in reduced blood OC levels [54]. It also impairs calcium absorption, which may affect OC activation [55]. Guney et al. found a positive correlation between OC and vit D levels in patients with metabolic syndrome [56]. Vit D supplementation, on the other hand, is known to increase OC levels, while decreasing ucOC levels [57].

These data suggest that vit D levels modulate the balance of OC proteoforms.

Traditional antibody-based methods for biomarker measurement are limited by their inability to differentiate proteoforms and polymorphic variants in a single assay and often face issues with stability, sensitivity, and cost [58]. Recent advances include biosensors, chemiluminescent immunoassays, and LC-MS/MS techniques that improve specificity and sensitivity [21,58,59] and identify these different proteoforms.

A previous study reported successful quantification of parathyroid hormone fragments using MRM-MSIA, demonstrating the method’s specificity and sensitivity [60]. This study is the first to apply MSIA for reliable detection and quantification of OC fragments in normal vit D and patients with T2DM, validating this approach.

OC plays a central role at the intersection of bone metabolism and systemic glucose homeostasis. It acts as a hormone, influencing insulin secretion, insulin sensitivity, and overall glucose regulation. Vitamin K-dependent carboxylation converts osteocalcin into the carboxylated form that binds hydroxyapatite and supports mineralization, and the carboxylation status has been associated with type 2 diabetes in recent population studies [61]. On the other hand, ucOC exhibits endocrine activity and is the active form in glucose metabolism. It enhances insulin secretion, β-cell proliferation, and insulin sensitivity stimulating insulin secretion potentially improving insulin sensitivity in muscle and adipose tissue [62].

Similarly, vit D is essential for OC synthesis and carboxylation in osteoblasts, and its deficiency may disrupt these processes, leading to altered levels and functionality of circulating osteocalcin. In diabetes, impaired bone turnover and oxidative stress further affect osteocalcin expression and processing [63]. The mechanistic basis for a vitamin D influence on osteocalcin is reinforced by interventional evidence. In a randomized, double-blind trial in patients with type 2 diabetes mellitus, supplementation with vitamin D3 significantly reduced circulating undercarboxylated osteocalcin and lowered the undercarboxylated-to-carboxylated ratio, whereas vitamin K2 raised the carboxylated form [64].

This indicates that vitamin D status actively shapes the balance of osteocalcin species rather than merely correlating with total concentrations, and it provides a plausible framework for interpreting the altered osteocalcin profile observed in our vitamin D–deficient cohort. The combination of vit D deficiency and diabetes creates a unique biochemical environment that shifts OC proteoform balance, potentially influencing both bone remodeling and metabolic regulation. Our findings of altered OC-1 levels in this context may reflect such underlying pathophysiological changes. This study demonstrates, for the first time, the application of MSIA-LC-MS/MS to detect and quantify OC proteoforms in T2DM patients with vit D deficiency, offering high specificity and sensitivity over traditional immunoassays that can only distinguish between carboxylated and undercarboxylated OC.

These findings suggest the potential utility of OC proteoform profiling in assessing vit D status and metabolic dysfunction in T2DM.

The observed elevation of the proteoform OC-1 (aa64–71) in vit D-deficient T2DM patients may reflect a shift in osteocalcin processing, likely influenced by dysregulated bone remodeling. One possible explanation is enhanced proteolytic cleavage at the C-terminal region, potentially mediated by vit D-regulated enzymes such as matrix metalloproteinases or cathepsin K. Alternatively, OC-1 may exhibit greater biochemical stability or resistance to further degradation compared to other overlapping fragments, contributing to its increased abundance. The findings from our study may suggest that vit D deficiency may alter the balance of OC proteoforms, with potential implications for bone–metabolism cross-talk in metabolic disease.

Key strengths of the study include the use of stable isotope-labeled peptides, rigorous validation using standard reference materials, and peptide-level quantification, which addresses limitations of antibody cross-reactivity. However, limitations include a relatively small sample size, lack of longitudinal data, the absence of formal evaluation of matrix effects and recovery, and the requirement for specialized equipment and technical expertise, which may constrain broader clinical adoption. Limitation of MRM include that accuracy can be impacted by factors such as the quality of peptide selection, digestion efficiency, sample processing consistency, and potential interference from matrix effects or co-eluting compounds.

MSIA is also limited by challenges such as experimental complexity, low signal intensity in MS, and the restricted availability of high-quality antibodies [65]. Future studies involving larger, diverse cohorts and therapeutic monitoring, such as vit D supplementation, are warranted to further validate clinical applicability and explore the prognostic value of specific OC proteoforms in metabolic and bone disorders.

5. Conclusions

The multiple reaction monitoring–mass spectrometric immunoassay (MRM-MSIA) assay has proven to be useful in the quantitation of OC proteoforms as it demonstrated good analytical performance characterized by low LLOD and LLOQ, good precision, reproducibility, stability, and recovery. The results highlight the substantial potential of OC proteoforms as potential biomarkers for monitoring in patients with T2DM and vit D deficiency. Additionally, further investigation is warranted to establish a definitive relationship between vit D supplementation and the distribution of OC proteoforms.

Acknowledgments

We acknowledge the National Plan for Science, Technology, and Innovation (MAARIFAH) and King Abdulaziz City for Science and Technology, Saudi Arabia, for their support of this project (Project No. 14-MED-543-02). The authors used ChatGPT (GPT-5; OpenAI, San Francisco, CA, USA) during manuscript preparation to assist with minor language editing.

Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Supplementary Materials

The following supporting information can be downloaded at: https://www.mdpi.com/article/10.3390/mps9040117/s1, Table S1: Characteristics of study participants. Table S2: List of osteocalcin signature peptides and their internal standard details, including the instrumental conditions. Table S3: Outlines the pipetting technique for OC purification using a Thermo Finnpipette Novus i Multichannel Electronic Pipette equipped with Protein A/G MSIA-tips. Table S4: Summary of osteocalcin peptides stability under various storage environments for a specified duration. Figure S1: Immunoaffinity capture using antibody-coated porous tips.

Supplement file at the original source — open the original paper. This file is not included in this text import.

Author Contributions

All authors meet CRediT requirements. Detailed roles were as follows: R.M.N. contributed to Data curation, Formal analysis, Writing—original draft, and Writing—review & editing. H.B. contributed to Conceptualization, Methodology & Laboratory Investigation, Supervision, Data curation, Formal analysis, Writing—original draft, and Writing—review & editing. A.M. contributed to Conceptualization, Patient Recruitment, Methodology & Laboratory Investigation, Supervision, Data curation, Formal analysis, Writing—original draft, and Writing—review & editing. M.A.M. contributed to Methodology & Laboratory Investigation. S.S.J. contributed to Data curation, Formal analysis, Writing—original draft, and Writing—review & editing.

A.M.A.R. contributed to Methodology & Laboratory Investigation, Data curation, Formal analysis, Writing—original draft, and Writing—review & editing. A.A.A. contributed to Conceptualization, Patient Recruitment, Data curation, Formal analysis, Writing—original draft, and Writing—review & editing. All authors have read and agreed to the published version of the manuscript.

Institutional Review Board Statement

The study was conducted in accordance with the ethical principles of the Declaration of Helsinki. The Institutional Review Board of the College of Medicine, King Saud University, approved the study (Approval No: E-16-1752), and all participants provided written informed consent before joining.

Informed Consent Statement

Informed consent was obtained from all subjects involved in the study.

Data Availability Statement

The datasets generated, used, and/or analyzed during the current study are available from the corresponding author upon reasonable request.

Conflicts of Interest

The authors report there are no competing interests to declare. The authors have no relevant affiliations or financial involvement with any organization or entity with a financial interest in or financial conflict with the subject matter or materials discussed in the manuscript. This includes employment, consultancies, honoraria, stock ownership or options, expert testimony, grants or patents received or pending, or royalties.

Abbreviations

The following abbreviations are used in this manuscript: 25(OH)D25-hydroxyvitamin DABCammonium bicarbonateACNacetonitrileBLASTBasic Local Alignment Search ToolcOCcarboxylated OCDTTdithiothreitolEICExtracted ion chromatogramsFAformic acidHRMSHigh-resolution mass spectrometryIAAiodoacetamideICH-GCPInternational Conference on Harmonization for Good Clinical PracticeIRBInstitutional Review BoardLC-MS/MSLiquid Chromatography–Mass SpectrometryLODlower limit of detectionLLOQlower limit of quantitation(MALDI)-MSmatrix-assisted laser desorption/ionization mass spectrometryMeOHmethanolMRM-MSIAmultiple reaction monitoring–mass spectrometric immunoassayMSmass spectrometryMSIAmass spectrometric immunoassayNCBINational Center for Biotechnology InformationN-MIDN-terminal/mid-regionOCOsteocalcinPCpost-translational modificationsQCQuality controlQCHQuality Control HighQCLQuality Control LowQCMQuality Control MediumSPEsolid-phase extractionT2DMtype 2 diabetes mellitusucOCuncarboxylated OCVit Dvitamin D

References

1. Komori T. Functions of Osteocalcin in Bone, Pancreas, Testis, and Muscle Int. J. Mol. Sci. 2020 21 7513 10.3390/ijms21207513 33053789 PMC7589887
2. Delmas P. Eastell R. Garnero P. Seibel M. Stepan J. Committee of Scientific Advisors of the International Osteoporosis Foundation The use of biochemical markers of bone turnover in osteoporosis Osteoporos. Int. 2000 11 S2 10.1007/s001980070002 11193237
3. Burt L.A. Billington E.O. Rose M.S. Raymond D.A. Hanley D.A. Boyd S.K. Effect of High-Dose Vitamin D Supplementation on Volumetric Bone Density and Bone Strength: A Randomized Clinical Trial JAMA 2019 322 736 745 10.1001/jama.2019.11889 31454046 PMC6714464
4. Lei H. Liu J. Wang W. Yang X. Feng Z. Zang P. Lu B. Shao J. Association between osteocalcin, a pivotal marker of bone metabolism, and secretory function of islet beta cells and alpha cells in Chinese patients with type 2 diabetes mellitus: An observational study Diabetol. Metab. Syndr. 2022 14 160 10.1186/s13098-022-00932-8 36307866 PMC9615358
5. Abugoukh T.M. Al Sharaby A. Elshaikh A.O. Joda M. Madni A. Ahmed I. Abdalla R.S. Ahmed K. Elazrag S.E. Abdelrahman N. Does Vitamin D Have a Role in Diabetes? Cureus 2022 14 e30432 10.7759/cureus.30432 36407246 PMC9671203
6. Desentis-Desentis M.F. Rivas-Carrillo J.D. Sánchez-Enríquez S. Protective role of osteocalcin in diabetes pathogenesis J. Bone Miner. Metab. 2020 38 765 771 10.1007/s00774-020-01130-0 32725267
7. Wei J. Hanna T. Suda N. Karsenty G. Ducy P. Osteocalcin promotes β-cell proliferation during development and adulthood through Gprc6a Diabetes 2014 63 1021 1031 10.2337/db13-0887 24009262 PMC3931403
8. Taderegew M.M. Woldeamanuel G.G. Wondie A. Getawey A. Abegaz A.N. Adane F. Vitamin D deficiency and its associated factors among patients with type 2 diabetes mellitus: A systematic review and meta-analysis BMJ Open 2023 13 e075607 10.1136/bmjopen-2023-075607 37798019 PMC10565281
9. Mangal D.K. Shaikh N. Tolani H. Gautam D. Pandey A.K. Sonnathi Y. Gupta S.D. Kalra S. Sharma K.C. Prasad J. Burden of micronutrient deficiency among patients with type 2 diabetes: Systematic review and meta-analysis BMJ Nutr. Prev. Health 2025 8 e000950 10.1136/bmjnph-2024-000950 40771523 PMC12322531
10. Saadon H.B. Vitamin D and type 2 diabetes mellitus: Mechanisms, clinical evidence, and future perspectives Bull. Natl. Res. Cent. 2025 49 82 10.1186/s42269-025-01377-5
11. Giudici K.V. Fisberg R.M. Marchioni D.M.L. Peters B.S.E. Martini L.A. Crosstalk between bone and fat tissue: Associations between vitamin D, osteocalcin, adipokines, and markers of glucose metabolism among adolescents J. Am. Coll. Nutr. 2017 36 273 280 10.1080/07315724.2016.1274923 28443718
12. Holick M.F. Binkley N.C. Bischoff-Ferrari H.A. Gordon C.M. Hanley D.A. Heaney R.P. Murad M.H. Weaver C.M. Evaluation, treatment, and prevention of vitamin D deficiency: An Endocrine Society clinical practice guideline J. Clin. Endocrinol. Metab. 2011 96 1911 1930 10.1210/jc.2011-0385 21646368
13. Malashkevich V.N. Almo S.C. Dowd T.L. X-ray crystal structure of bovine 3 Glu-osteocalcin Biochemistry 2013 52 8387 8392 10.1021/bi4010254 24138653 PMC4517604
14. Salehi M. Leung-Pineda V. Chapter 12—Disorders of calcium and phosphate metabolism in infants and children Biochemical and Molecular Basis of Pediatric Disease 5th ed. Dietzen D. Bennett M. Wong E. Haymond S. Academic PressCambridge, MA, USA2021 379 410
15. Patti A. Gennari L. Merlotti D. Dotta F. Nuti R. Endocrine actions of osteocalcin Int. J. Endocrinol. 2013 2013 846480 10.1155/2013/846480 23737779 PMC3657394
16. Eick G.N. Madimenos F.C. Cepon-Robins T.J. Devlin M.J. Kowal P. Sugiyama L.S. Snodgrass J.J. Validation of an enzyme-linked immunoassay assay for osteocalcin, a marker of bone formation, in dried blood spots Am. J. Hum. Biol. 2020 32 e23394 10.1002/ajhb.23394 32017301
17. Alajam R.A. Alqahtani A.S. Moon S. Sarmento C.V.M. Smirnova I.V. Pang M.Y.C. Liu W. Evaluating Biomarkers of Bone Health After an 8-Week Walking Program in Non-Ambulatory Stroke Survivors: A Pilot Study J. Clin. Med. 2024 13 6453 10.3390/jcm13216453 39518593 PMC11547151
18. Wang Y. Zhou H. Wang H. Ma J. Chen X. Yang H. Zheng H. Wang A. Serum osteocalcin as a novel biomarker for differentiating growth hormone deficiency from idiopathic short stature Front. Endocrinol. 2026 17 1745971 10.3389/fendo.2026.1745971 41890194 PMC13013015
19. Tian Y. Ming J. The role of circadian rhythm in osteoporosis; a review Front. Cell Dev. Biol. 2022 10 960456 10.3389/fcell.2022.960456 36238690 PMC9550872
20. Derwich W. Feć K. Gawda A. Kopa K. Kopeć J. Nowak I. Seńcio N. Rauf A. Ahmad Z. Świątek-Pawelczak A. Osteocalcin Beyond Bone: Molecular Mechanisms, Endocrine Networks, and Translational Perspectives Across Metabolism, Neurobiology, and Chronic Disease Int. J. Mol. Sci. 2026 27 2992 10.3390/ijms27072992 41977179 PMC13074106
21. Han S. Xue Y. Zhang J. Huang J. Liu X. Yang Y. Bai Z. Wang C. A chemiluminescent immunoassay for osteocalcin in human serum and a solution to the “hook effect” J. Anal. Methods Chem. 2020 2020 8891437 10.1155/2020/8891437 33376621 PMC7744234
22. Alexandridou A. Stokes C.S. Volmer D.A. Measurement of Serum Free Vitamin D Concentrations: Importance, Challenges, and the Emerging Role of Mass Spectrometry Clin. Chem. 2024 71 254 265 10.1093/clinchem/hvae202 39661472
23. Braun V. Ceglarek U. Gaudl A. Gawinecka J. Müller D. Rauh M. Weber M. Seger C. Evaluation of five multisteroid LC–MS/MS methods used for routine clinical analysis: Comparable performance was obtained for nine analytes Clin. Chem. Lab. Med. 2024 62 900 910 38038605 10.1515/cclm-2023-0847
24. Fatica E.M. Larkey N.E. Singh R.J. Quantification of Parathyroid Hormone and its Fragments in Serum by Liquid Chromatography–High-Resolution Mass Spectrometry Clinical Applications of Mass Spectrometry in Biomolecular Analysis: Methods and Protocols HumanaNew York, NY, USA2022 365 373 10.1007/978-1-0716-2565-1_32 36127604
25. Determe W. Hauge S.C. Demeuse J. Massonnet P. Grifnée E. Huyghebaert L. Dubrowski T. Schoumacher M. Peeters S. Le Goff C. Osteocalcin: A bone protein with multiple endocrine functions Clin. Chim. Acta 2025 567 120067 10.1016/j.cca.2024.120067 39631494
26. Liu M. Miao D. Qin S. Liu H. Bai Y. Mass tag-based mass spectrometric immunoassay and its bioanalysis applications TrAC Trends Anal. Chem. 2022 157 116745 10.1016/j.trac.2022.116745
27. Nelson R.W. Krone J.R. Bieber A.L. Williams P. Mass spectrometric immunoassay Anal. Chem. 1995 67 1153 1158 10.1021/ac00103a003 15134097
28. Yassine H.N. Jackson A.M. Reaven P.D. Nedelkov D. Nelson R.W. Lau S.S. Borchers C.H. The Application of Multiple Reaction Monitoring to Assess Apo A-I Methionine Oxidations in Diabetes and Cardiovascular Disease Transl. Proteom. 2014 4–5 18 24 10.1016/j.trprot.2014.10.001 25705587 PMC4331021
29. Yassine H.N. Trenchevska O. He H. Borges C.R. Nedelkov D. Mack W. Kono N. Koska J. Reaven P.D. Nelson R.W. Serum amyloid a truncations in type 2 diabetes mellitus PLoS ONE 2015 10 e0115320 10.1371/journal.pone.0115320 25607823 PMC4301920
30. Oran P.E. Trenchevska O. Nedelkov D. Borges C.R. Schaab M.R. Rehder D.S. Jarvis J.W. Sherma N.D. Shen L. Krastins B. Parallel workflow for high-throughput (>1,000 samples/day) quantitative analysis of human insulin-like growth factor 1 using mass spectrometric immunoassay PLoS ONE 2014 9 e92801 10.1371/journal.pone.0092801 24664114 PMC3963945
31. Yassine H.N. Trenchevska O. Ramrakhiani A. Parekh A. Koska J. Walker R.W. Billheimer D. Reaven P.D. Yen F.T. Nelson R.W. The association of human apolipoprotein C-III sialylation proteoforms with plasma triglycerides PLoS ONE 2015 10 e0144138 10.1371/journal.pone.0144138 26633899 PMC4669142
32. Mitri J. Pittas A.G. Vitamin D and diabetes Endocrinol. Metab. Clin. N. Am. 2014 43 205 232 10.1016/j.ecl.2013.09.010 24582099 PMC3942667
33. Fuentes-Barría H. Aguilera-Eguía R. Flores-Fernández C. Angarita-Davila L. Rojas-Gómez D. Alarcón-Rivera M. López-Soto O. Maureira-Sánchez J. Vitamin D and Type 2 Diabetes Mellitus: Molecular Mechanisms and Clinical Implications—A Narrative Review Int. J. Mol. Sci. 2025 26 2153 10.3390/ijms26052153 40076782 PMC11900948
34. International Council for Harmonisation of Technical Requirements for Pharmaceuticals for Human Use Integrated Addendum to ICH E6(R2): Guideline for Good Clinical Practice ICHGeneva, Switzerland2016
35. World Medical Association World Medical Association Declaration of Helsinki: Ethical principles for medical research involving human subjects JAMA 2013 310 2191 2194 24141714 10.1001/jama.2013.281053
36. Smith L.M. Kelleher N.L. Proteoform: A single term describing protein complexity Nat. Methods 2013 10 186 187 10.1038/nmeth.2369 23443629 PMC4114032
37. Aebersold R. Agar J.N. Amster I.J. Baker M.S. Bertozzi C.R. Boja E.S. Costello C.E. Cravatt B.F. Fenselau C. Garcia B.A. How many human proteoforms are there? Nat. Chem. Biol. 2018 14 206 214 10.1038/nchembio.2576 29443976 PMC5837046
38. Hauschka P.V. Lian J.B. Cole D.E. Gundberg C.M. Osteocalcin and matrix Gla protein: Vitamin K-dependent proteins in bone Physiol. Rev. 1989 69 990 1047 10.1152/physrev.1989.69.3.990 2664828
39. Gundberg C.M. Lian J.B. Booth S.L. Vitamin K-Dependent Carboxylation of Osteocalcin: Friend or Foe? Adv. Nutr. 2012 3 149 157 10.3945/an.112.001834 22516722 PMC3648715
40. Smith L.M. Kelleher N.L. Proteoforms as the next proteomics currency Science 2018 359 1106 1107 10.1126/science.aat1884 29590032 PMC5944612
41. Nimer R.M. Sumaily K.M. Almuslat A. Abdel Jabar M. Sabi E.M. Al-Muhaizea M.A. Abdel Rahman A.M. Dystrophin Protein Quantification as a Duchenne Muscular Dystrophy Diagnostic Biomarker in Dried Blood Spots Using Multiple Reaction Monitoring Tandem Mass Spectrometry: A Preliminary Study Molecules 2022 27 3662 10.3390/molecules27123662 35744792 PMC9231037
42. Malkawi A.K. Nimer R.M. Almogren M. Masood A. Alarfaj A.S. Benabdelkamel H. Abdel Rahman A.M. Siaj M. Quantitative analysis of soluble costimulatory molecules as potential diagnostic biomarkers for rheumatoid arthritis using LC-MS/MS in MRM mode Clin. Chim. Acta 2023 548 117501 10.1016/j.cca.2023.117501 37516334
43. Sumaily K.M. Nimer R. Alzahrani M. Jabar M.A. Alodib A. Sabi E.M. Nizami I. Rahman A.M.A. CFTR protein quantification as a cystic fibrosis diagnostic biomarker in dried blood spots using multiple reaction monitoring tandem mass spectrometry J. Pharm. Biomed. Anal. 2022 216 114801 10.1016/j.jpba.2022.114801 35504217
44. Garofolo F. Michon J. Leclaire V. Booth B. Lowes S. Viswanathan C. Welink J. Haidar S. Teixeira L.d.S. Tang D. Conference Report: US FDA/EMA harmonization of their bioanalytical guidance/guideline and activities of the Global Bioanalytical Consortium Bioanalysis 2012 4 231 236 10.4155/bio.12.1 22303826
45. IHT Guideline. Validation of Analytical Procedures: Text And Methodology Q2 (R1). In Proceedings of the International Conference on Harmonization, Geneva, Switzerland 2005 Available online: https://somatek.com/wp-content/uploads/2014/06/sk140605h.pdf(accessed on 9 June 2026)
46. Galal M.A. Abdel Jabar M. Zhra M. Abdel Rahman A.M. Aljada A. Absolute quantification of senescence mediators in cells using multiple reaction monitoring liquid chromatography-Tandem mass spectrometry Anal. Chim. Acta 2021 1184 339009 10.1016/j.aca.2021.339009 34625254
47. U.S. Food and Drug Administration M10 Bioanalytical Method Validation and Study Sample Analysis Food and Drug Administration Center for Drug Evaluation and Research and Center for Biologics Evaluation and ResearchSilver Spring, MD, USA2022
48. Xu Y. Shen L. Liu L. Zhang Z. Hu W. Undercarboxylated osteocalcin and its associations with bone mineral density, bone turnover markers, and prevalence of osteopenia and osteoporosis in chinese population: A cross-sectional study Front. Endocrinol. 2022 13 843912 10.3389/fendo.2022.843912 35898467 PMC9309304
49. Vlot M.C. Boekel L. Kragt J. Killestein J. van Amerongen B.M. de Jonge R. den Heijer M. Heijboer A.C. Multiple Sclerosis Patients Show Lower Bioavailable 25(OH)D and 1,25(OH)2D, but No Difference in Ratio of 25(OH)D/24,25(OH)2D and FGF23 Concentrations Nutrients 2019 11 2774 10.3390/nu11112774 31731605 PMC6893545
50. Brennan-Speranza T.C. Conigrave A.D. Osteocalcin: An Osteoblast-Derived Polypeptide Hormone that Modulates Whole Body Energy Metabolism Calcif. Tissue Int. 2015 96 1 10 10.1007/s00223-014-9931-y 25416346
51. Chen L. Gao G. Shen L. Yue H. Zhang G. Zhang Z. Serum sclerostin and its association with bone turnover marker in metabolic bone diseases Dis. Markers 2022 2022 7902046 10.1155/2022/7902046 36124027 PMC9482545
52. Guo X. Li Y. Zhou Y. Zhang C. Liang S. Zheng Y. Chen X. Cai G. Osteocalcin association with vascular function in chronic kidney disease J. Clin. Hypertens. 2022 24 928 936 10.1111/jch.14523 35687487 PMC9278578
53. Kapoor K. Pi M. Nishimoto S.K. Quarles L.D. Baudry J. Smith J.C. The carboxylation status of osteocalcin has important consequences for its structure and dynamics Biochim. Biophys. Acta Gen. Subj. 2021 1865 129809 10.1016/j.bbagen.2020.129809 33340588 PMC8843000
54. Li Y. Zhao P. Jiang B. Liu K. Zhang L. Wang H. Tian Y. Li K. Liu G. Modulation of the vitamin D/vitamin D receptor system in osteoporosis pathogenesis: Insights and therapeutic approaches J. Orthop. Surg. Res. 2023 18 860 10.1186/s13018-023-04320-4 37957749 PMC10644527
55. van de Peppel J. van Leeuwen J.P. Vitamin D and gene networks in human osteoblasts Front. Physiol. 2014 5 137 10.3389/fphys.2014.00137 24782782 PMC3988399
56. Guney G. Sener-Simsek B. Tokmak A. Yucel A. Buyukkagnici U. Yilmaz N. Engin-Ustun Y. Ozgu-Erdinc A.S. Assessment of the Relationship between Serum Vitamin D and Osteocalcin Levels with Metabolic Syndrome in Non-Osteoporotic Postmenopausal Women Geburtshilfe Frauenheilkd. 2019 79 293 299 10.1055/a-0767-6572 30880828 PMC6414302
57. Sukumar D. Schneider S. Ambia-Sobhan H. Schlussel Y. Shapses S. Vitamin D supplementation increases osteocalcin but not other markers of bone turnover during short-term caloric restriction in women FASEB J. 2011 25 218.5 10.1096/fasebj.25.1_supplement.218.5
58. Uygun E. Deniz H. Use of osteocalcin-specific Gpr158 protein in biosensor technology for osteocalcin detection Chem. Pap. 2024 78 5577 5583 10.1007/s11696-024-03500-8
59. Zhang Z. Siddiqi H. Huang Y.-P. McClorry S. Ji P. Barile D. Slupsky C.M. An LC-MS/MS Method for the Simultaneous Quantification of Insulin, Cortisol, Glucagon-like Peptide 1, Ghrelin, and Osteocalcin Separations 2024 11 41 10.3390/separations11020041
60. Benabdelkamel H. Nimer R.M. Masood A. Al Mogren M. Abdel Rahman A.M. Alfadda A.A. Multiple Reaction Monitoring–Mass Spectrometric Immunoassay Analysis of Parathyroid Hormone Fragments with Vitamin D Deficiency in Patients with Diabetes Mellitus Proteomes 2024 12 30 10.3390/proteomes12040030 39449502 PMC11503337
61. Qi L. Wu H. Li X. Xu Y. Liu L. Osteocalcin carboxylation/undercarboxylation levels and gene variants associated with type 2 diabetes mellitus in the Chinese Han population: Osteocalcin carboxylation status and gene variants in T2DM Acta Biochim. Biophys. Sin. 2025 57 1901 10.3724/abbs.2025060 40302552 PMC12666668
62. Cipriani C. Colangelo L. Santori R. Renella M. Mastrantonio M. Minisola S. Pepe J. The Interplay Between Bone and Glucose Metabolism Front. Endocrinol. 2020 11 122 10.3389/fendo.2020.00122 32265831 PMC7105593
63. Sharma P. Sharma R.K. Gaur K. Understanding the impact of diabetes on bone health: A clinical review Metab. Open 2024 24 100330 10.1016/j.metop.2024.100330 39606009 PMC11600011
64. Aguayo-Ruiz J.I. García-Cobián T.A. Pascoe-González S. Sánchez-Enríquez S. Llamas-Covarrubias I.M. García-Iglesias T. López-Quintero A. Llamas-Covarrubias M.A. Trujillo-Quiroz J. Rivera-Leon E.A. Effect of supplementation with vitamins D3 and K2 on undercarboxylated osteocalcin and insulin serum levels in patients with type 2 diabetes mellitus: A randomized, double-blind, clinical trial Diabetol. Metab. Syndr. 2020 12 73 10.1186/s13098-020-00580-w 32831908 PMC7436967
65. Trenchevska O. Nelson R.W. Nedelkov D. Mass Spectrometric Immunoassays in Characterization of Clinically Significant Proteoforms Proteomes 2016 4 13 10.3390/proteomes4010013 28248223 PMC5217360
Figure 1

Experimental protocol for osteocalcin mass spectrometric immunoassay.

Figure image at the original source — open the original paper. This file is not included in this text import.
Figure 2

Extracted ion chromatograms (EIC) showing transitions of osteocalcin (OC) variants and their corresponding internal standard transitions, analyzed at a concentration of 10 µg/mL: (A) Quantitative transitions for OC-1 (327.32 > 183.133) and its labeled internal standard (417.37 > 282.16); (B) Quantitative transitions for OC-2 (412.42 > 272.194) and its labeled internal standard (417.37 > 282.16); (C) Quantitative transitions for OC-3 (837.9 > 253.1) and its labeled internal standard (840.2 > 253.02).

Figure image at the original source — open the original paper. This file is not included in this text import.
Figure 3

Representative calibration curves for (A) OC-1, (B) OC-2, and (C) OC-3, where the x-axis represents the nominal concentration of the proteoform in nM, and the y-axis represents the area ratio between the unlabeled-to-labeled signature peptide of each proteoform measured.

Figure image at the original source — open the original paper. This file is not included in this text import.
Figure 4

(A) Comparison of OC-1 (aa64–71) levels between subjects with T2DM and vit D insufficiency vs. those with normal vit D levels. A significant elevation in OC-1 was observed in the vit D insufficient group (p ≤ 0.01); (B) ROC curve evaluating the diagnostic performance of OC-1 in patients with T2DM and vit D insufficiency in comparison to those with T2DM and normal vit D levels. The area under the curve (AUC) for OC-1 was 0.8263 (95% CI, p = 0.0004).

The diagonal reference red line represents no discriminatory ability (AUC = 0.50), corresponding to classification performance expected by chance.

Figure image at the original source — open the original paper. This file is not included in this text import.
Table 1

Linearity and sensitivity summary over three days.

Signature Peptide IDLLOQ (n = 6)Slope
(n = 3)
Intercept
(n = 3)
R2
(n = 3)
Concentration
(nM)
Inter-Day
Accuracy (%)
Inter-Day
Precision (%)
OC-10.5098.77.10.02311−0.086300.9993
OC-20.50105.32.90.04440−0.048900.9998
OC-30.50101.34.10.042890.25200.9950

OC, osteocalcin; LLOQ, Lower Limit of Quantification; R2, coefficient of determination.

Table 2

Inter-day validation summary.

Signature Peptide IDQCL 35.0 nM
(n = 6)
QCM 150.0 nM
(n = 6)
QCH 300.0 nM
(n = 6)
Mean
(nM)
SD Accuracy
%
Precision %Mean (nM) SD Accuracy %Precision
%
Mean
(nM)
SD Accuracy
%
Precision
%
OC-134.91.5799.714.5155.22.6103.471.70330.322.0110.16.7
OC-233.41.0695.43.17154.078.16102.75.3310.34.7103.41.5
OC-335.22.65100.577.5158.99.4105.95.9311.314.2103.74.6

QCL, Quality Control Low; QCM, Quality Control Medium; QCH, Quality Control High; SD, standard deviation; OC, osteocalcin.

Table 3

Intra-day validation summary.

Signature Peptide IDQCL 35.0 nM
(n = 18)
QCM 150.0 nM
(n = 18)
QCH 300.0 nM
(n = 18)
Mean (nM) SD Accuracy
%
Precision %Mean (nM) SD Accuracy
%
Precision %Mean (nM)SD Accuracy
%
Precision
%
OC-135.23.9100.711.0153.27.7102.15.0308.517.5102.85.7
OC-231.02.788.88.9159.25.0106.13.1298.515.299.55.1
OC-331.62.090.26.3147.511.498.37.7303.216.4101.15.4

QCL, Quality Control Low; QCM, Quality Control Medium; QCH, Quality Control High, SD, standard deviation, OC, osteocalcin.

Publication and source details

Original title: Analysis of Osteocalcin Hormone Proteoforms with Vitamin D Deficiency in Patients with Diabetes Mellitus Using Multiple-Reaction Monitoring–Mass Spectrometric Immunoassay Approach

Refat M. Nimer; Hicham Benabdelkamel; Afshan Masood; Maha Al Mogren; Salini Scaria Joy; Anas M. Abdel Rahman; Assim A. Alfadda

Methods and Protocols · 2026

* Correspondence: helkamel@ksu.edu.sa (H.B.); aabdelrahman46@kfshrc.edu.sa (A.M.A.R.)© 2026 by the authors.2026https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license. King Abdulaziz City for Science and Technology, Saudi Arabiahttps://ror.org/05tdz6m39 14-MED-543-02This work was supported by the National Plan for Science, Technology, and Innovation (MAARIFAH) under Grant No. 14-MED-543-02, King Abdulaziz City for Science and Technology, Saudi Arabia.

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-08T15:06:55+00:00

DOI: 10.3390/mps9040117 · PMC13515257