Secondary relevance to vitamin D This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.
This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.
Why this paper is included
Supporting source evidence:
Patients with aPWV of ≥ 10 m/s were older (72.9 ± 10.3 vs. 52.6 ± 14.4 years, p < 0.01) with a higher ECW/TBW ratio (40.6 ± 1.3 vs. 39.6 ± 1.7, p < 0.001), with no differences in active vitamin D3 or calcium‐containing medications.
Source: Abstract. View original paper
Relevance classification does not establish study quality, causation or editorial approval.
Study design Study design awaiting verification.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.
Meta-analysis unclear · Blinding unclear / not reported · Human research reported
How this paper was classified
Automatic source-based classification; awaiting editorial verification. This is not a quality score.
All patients were prescribed cholecalciferol 20 000 IU weekly.
Source: Methods.
What the study types mean
- Systematic review
- Uses explicit methods to identify, assess and summarise research on a defined question.
- Scoping review
- Maps the extent and characteristics of research on a topic.
- Narrative review
- Discusses existing research; systematic-review methods have not been established by this classification.
- Review / evidence synthesis
- Reviews existing research; the exact review methods need further assessment.
- Randomised controlled trial
- Assigns participants or groups to comparison interventions by chance.
- Non-randomised intervention study
- Examines an intervention without random allocation.
- Cohort study
- Examines exposures and outcomes over time within a defined group.
- Case-control study
- Compares people with an outcome against people without it, examining exposures.
- Cross-sectional study
- Examines a population at a particular point in time.
- Observational study
- Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
- Case report
- Describes an individual case.
- Case series
- Describes a group of individual cases.
- Secondary analysis
- Analyses existing study data; this paper is not automatically another independent trial.
- Laboratory study
- Investigates biological processes in a laboratory setting.
- Qualitative study
- Examines experiences or meanings using qualitative methods.
- Genetic instrumental-variable study
- Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
- Study protocol
- Describes planned methods and is not evidence that the planned study has reported results.
- Multiple reported designs
- More than one design is explicitly reported; examine the supporting methods.
- Study design awaiting verification
- The available source does not establish a sufficiently clear study design.
Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.
Abstracts
Aortic Pulse Wave Velocity and Extracellular Water Expansion in Hemodialysis Patients
Study design awaiting verification · Artificial Organs · 2025
Original publication title
Aortic Pulse Wave Velocity and Extracellular Water Expansion in Hemodialysis Patients
© 2025 The Author(s). Artificial Organs published by International Center for Artificial Organ and Transplantation (ICAOT) and Wiley Periodicals LLC.
Original publication · Publisher record · CC BY 4.0
Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.
At a glance
Abstract: What background does the paper provide?
Pulse wave velocity (PWV), a measurement of arterial stiffness, is a risk factor for cardiovascular mortality in hemodialysis patients. Debate continues as to whether PWV is increased by volume overload. As such, we reviewed the association between volume overload and PWV.
Source: BackgroundAbstract: What methods does the paper describe?
We measured aortic PWV (aPWV) in hemodialysis patients attending routine dialysis sessions with contemporaneous measurements of extracellular water/total body water (ECW/TBW) ratios using multifrequency bioimpedance.
Source: MethodsAbstract: Results
A total of 102 patients, 63.7% male, mean age 63.5 ± 15.9 years, 44.1% diabetic, median dialysis duration 22.2 (4.9 to 52.8) months, weight 73.7 ± 15.8 kg, and central systolic blood pressure 157 ± 35 mmHg had a mean aPWV of 10.1 ± 2.5 m/s. Patients dialyzed with a low dialysate calcium (median 1.0 [1.0 to 1.25] mmol/L). Patients with aPWV of ≥ 10 m/s were older (72.9 ± 10.3 vs. 52.6 ± 14.4 years, p < 0.01) with a higher ECW/TBW ratio (40.6 ± 1.3 vs. 39.6 ± 1.7, p < 0.001), with no differences in active vitamin D3 or calcium‐containing medications.
Aortic PWV was associated with age (r = 0.9, p < 0.001) and ECW/TBW (r = 0.33, p = < 0.001), and after adjusting aPWV for age, ECW/TBW remained higher (40.5 ± 1.5 vs. 39.5 ± 1.5, p < 0.001). On multivariable testing, ECW/TBW remained independently associated with a raised aPWV (odds ratio [OR] 1.59 (95% confidence intervals [CI] 1.06 to 2.41), p = 0.026), and after age adjustment (OR 1.74 (95% CI 1.19 to 2.53, p = 0.004)).
Source: ResultsAbstract: Conclusions
This study highlights the association between volume overload, as determined by bioimpedance in hemodialysis patients, and arterial stiffness measured by aPWV. These results would reinforce the importance of improving volume control in hemodialysis patients to reduce cardiovascular risk.
Source: ConclusionsAuthors’ abstract
ABSTRACT
Background
Pulse wave velocity (PWV), a measurement of arterial stiffness, is a risk factor for cardiovascular mortality in hemodialysis patients. Debate continues as to whether PWV is increased by volume overload. As such, we reviewed the association between volume overload and PWV.
Methods
We measured aortic PWV (aPWV) in hemodialysis patients attending routine dialysis sessions with contemporaneous measurements of extracellular water/total body water (ECW/TBW) ratios using multifrequency bioimpedance.
Results
A total of 102 patients, 63.7% male, mean age 63.5 ± 15.9 years, 44.1% diabetic, median dialysis duration 22.2 (4.9 to 52.8) months, weight 73.7 ± 15.8 kg, and central systolic blood pressure 157 ± 35 mmHg had a mean aPWV of 10.1 ± 2.5 m/s. Patients dialyzed with a low dialysate calcium (median 1.0 [1.0 to 1.25] mmol/L). Patients with aPWV of ≥ 10 m/s were older (72.9 ± 10.3 vs. 52.6 ± 14.4 years, p < 0.01) with a higher ECW/TBW ratio (40.6 ± 1.3 vs. 39.6 ± 1.7, p < 0.001), with no differences in active vitamin D3 or calcium‐containing medications.
Aortic PWV was associated with age (r = 0.9, p < 0.001) and ECW/TBW (r = 0.33, p = < 0.001), and after adjusting aPWV for age, ECW/TBW remained higher (40.5 ± 1.5 vs. 39.5 ± 1.5, p < 0.001). On multivariable testing, ECW/TBW remained independently associated with a raised aPWV (odds ratio [OR] 1.59 (95% confidence intervals [CI] 1.06 to 2.41), p = 0.026), and after age adjustment (OR 1.74 (95% CI 1.19 to 2.53, p = 0.004)).
Conclusions
This study highlights the association between volume overload, as determined by bioimpedance in hemodialysis patients, and arterial stiffness measured by aPWV. These results would reinforce the importance of improving volume control in hemodialysis patients to reduce cardiovascular risk.
Publication and source details
Original title: Aortic Pulse Wave Velocity and Extracellular Water Expansion in Hemodialysis Patients
Roohi Chhabra; Andrew Davenport
Artificial Organs · 2025
* Correspondence:Roohi Chhabra (roohi.chhabra.20@ucl.ac.uk)
© 2025 The Author(s). Artificial Organs published by International Center for Artificial Organ and Transplantation (ICAOT) and Wiley Periodicals LLC.https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Repository JATS snapshot; version as supplied
Source retrieved: 2026-11-11T01:39:00.917685+00:00