Secondary relevance to vitamin D This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.
This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.
Why this paper is included
Supporting source evidence:
Both groups had comparable serum vitamin-D and creatinine levels.
Source: Results. View original paper
Relevance classification does not establish study quality, causation or editorial approval.
Study design Study design awaiting verification.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.
Meta-analysis unclear · Blinding unclear / not reported · Human research reported
How this paper was classified
Automatic source-based classification; awaiting editorial verification. This is not a quality score.
Participants were enrolled after written informed consent.
Source: Methods.
What the study types mean
- Systematic review
- Uses explicit methods to identify, assess and summarise research on a defined question.
- Scoping review
- Maps the extent and characteristics of research on a topic.
- Narrative review
- Discusses existing research; systematic-review methods have not been established by this classification.
- Review / evidence synthesis
- Reviews existing research; the exact review methods need further assessment.
- Randomised controlled trial
- Assigns participants or groups to comparison interventions by chance.
- Non-randomised intervention study
- Examines an intervention without random allocation.
- Cohort study
- Examines exposures and outcomes over time within a defined group.
- Case-control study
- Compares people with an outcome against people without it, examining exposures.
- Cross-sectional study
- Examines a population at a particular point in time.
- Observational study
- Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
- Case report
- Describes an individual case.
- Case series
- Describes a group of individual cases.
- Secondary analysis
- Analyses existing study data; this paper is not automatically another independent trial.
- Laboratory study
- Investigates biological processes in a laboratory setting.
- Qualitative study
- Examines experiences or meanings using qualitative methods.
- Genetic instrumental-variable study
- Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
- Study protocol
- Describes planned methods and is not evidence that the planned study has reported results.
- Multiple reported designs
- More than one design is explicitly reported; examine the supporting methods.
- Study design awaiting verification
- The available source does not establish a sufficiently clear study design.
Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.
Abstracts
Assessment of gait and posture characteristics using a smartphone wearable system for persons with osteoporosis with and without falls
Study design awaiting verification · Scientific Reports · 2023
Original publication title
Assessment of gait and posture characteristics using a smartphone wearable system for persons with osteoporosis with and without falls
© This is a U.S. Government work and not under copyright protection in the US; foreign copyright protection may apply 2023
Original publication · Publisher record · CC BY 4.0
Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.
At a glance
What does the authors’ abstract report?
We used smartphone technology to differentiate the gait characteristics of older adults with osteoporosis with falls from those without falls. We assessed gait mannerism and obtained activities of daily living (ADLs) with wearable sensor systems (smartphones and inertial measurement units [IMUs]) to identify fall-risk characteristics. We recruited 49 persons with osteoporosis: 14 who had a fall within a year before recruitment and 35 without falls. IMU sensor signals were sampled at 50 Hz using a customized smartphone app (Lockhart Monitor) attached at the pelvic region.
Longitudinal data was collected using MoveMonitor+ (DynaPort) IMU over three consecutive days. Given the close association between serum calcium, albumin, PTH, Vitamin D, and musculoskeletal health, we compared these markers in individuals with history of falls as compared to nonfallers. For the biochemical parameters fall group had significantly lower calcium (P = 0.01*) and albumin (P = 0.05*) and higher parathyroid hormone levels (P = 0.002**) than nonfall group. In addition, persons with falls had higher sway area (P = 0.031*), lower dynamic stability (P < 0.001***), gait velocity (P = 0.012*), and were less able to perform ADLs (P = 0.002**).
Thus, persons with osteoporosis with a history of falls can be differentiated by using dynamic real-time measurements that can be easily captured by a smartphone app, thus avoiding traditional postural sway and gait measures that require individuals to be tested in a laboratory setting.
Authors’ abstract
We used smartphone technology to differentiate the gait characteristics of older adults with osteoporosis with falls from those without falls. We assessed gait mannerism and obtained activities of daily living (ADLs) with wearable sensor systems (smartphones and inertial measurement units [IMUs]) to identify fall-risk characteristics. We recruited 49 persons with osteoporosis: 14 who had a fall within a year before recruitment and 35 without falls. IMU sensor signals were sampled at 50 Hz using a customized smartphone app (Lockhart Monitor) attached at the pelvic region.
Longitudinal data was collected using MoveMonitor+ (DynaPort) IMU over three consecutive days. Given the close association between serum calcium, albumin, PTH, Vitamin D, and musculoskeletal health, we compared these markers in individuals with history of falls as compared to nonfallers. For the biochemical parameters fall group had significantly lower calcium (P = 0.01*) and albumin (P = 0.05*) and higher parathyroid hormone levels (P = 0.002**) than nonfall group. In addition, persons with falls had higher sway area (P = 0.031*), lower dynamic stability (P < 0.001***), gait velocity (P = 0.012*), and were less able to perform ADLs (P = 0.002**).
Thus, persons with osteoporosis with a history of falls can be differentiated by using dynamic real-time measurements that can be easily captured by a smartphone app, thus avoiding traditional postural sway and gait measures that require individuals to be tested in a laboratory setting.
Publication and source details
Original title: Assessment of gait and posture characteristics using a smartphone wearable system for persons with osteoporosis with and without falls
Krupa B. Doshi; Seong Hyun Moon; Michael D. Whitaker; Thurmon E. Lockhart
Scientific Reports · 2023
© This is a U.S. Government work and not under copyright protection in the US; foreign copyright protection may apply 2023https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.Repository JATS snapshot; version as supplied
Source retrieved: 2026-11-11T08:08:43.449006+00:00
DOI: 10.1038/s41598-023-27788-w · PMC9834330