Vitamin D3 for Life. Live Enlightened.

Research libraryVitamin D3 For Life
Study design and methods

Primary relevance to vitamin D Vitamin D is a stated subject of this paper.

Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.

Why this paper is included

Supporting source evidence:

In biochemistry analyses, the mean vitamin D level in Group A was lower than in the other groups.

Source: 3.1. Biochemistry Analysis. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Study design awaiting verification.

Study design awaiting verification

The available source does not establish a sufficiently clear study design.

Meta-analysis unclear · Blinding unclear / not reported · Animal research reported

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

Chronic Exposure to Static Magnetic Fields from Magnetic Resonance Imaging Devices Deserves Screening for Osteoporosis and Vitamin D Levels: A Rat Model

Source: Article title.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Abstracts

Chronic Exposure to Static Magnetic Fields from Magnetic Resonance Imaging Devices Deserves Screening for Osteoporosis and Vitamin D Levels: A Rat Model

Study design awaiting verification · International Journal of Environmental Research and Public Health · 2015

Original publication title

Chronic Exposure to Static Magnetic Fields from Magnetic Resonance Imaging Devices Deserves Screening for Osteoporosis and Vitamin D Levels: A Rat Model

Harun R. Gungor; Semih Akkaya; Nusret Ok; Aygun Yorukoglu; Cagdas Yorukoglu; Esat Kiter; Emin O. Oguz; Nazan Keskin; Gulcin A. Mete

© 2015 by the authors; licensee MDPI, Basel, Switzerland.

Original publication · Publisher record · CC BY 4.0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

At a glance

What does the authors’ abstract report?

Technicians often receive chronic magnetic exposures from magnetic resonance imaging (MRI) devices, mainly due to static magnetic fields (SMFs). Here, we ascertain the biological effects of chronic exposure to SMFs from MRI devices on the bone quality using rats exposed to SMFs in MRI examining rooms. Eighteen Wistar albino male rats were randomly assigned to SMF exposure (A), sham (B), and control (C) groups. Group A rats were positioned within 50 centimeters of the bore of the magnet of 1.5 T MRI machine during the nighttime for 8 weeks.

We collected blood samples for biochemical analysis, and bone tissue samples for electron microscopic and histological analysis. The mean vitamin D level in Group A was lower than in the other groups (p = 0.002). The mean cortical thickness, the mean trabecular wall thickness, and number of trabeculae per 1 mm2 were significantly lower in Group A (p = 0.003). TUNEL assay revealed that apoptosis of osteocytes were significantly greater in Group A than the other groups (p = 0.005).

The effect of SMFs in chronic exposure is related to movement within the magnetic field that induces low-frequency fields within the tissues. These fields can exceed the exposure limits necessary to deteriorate bone microstructure and vitamin D metabolism.

Authors’ abstract

Technicians often receive chronic magnetic exposures from magnetic resonance imaging (MRI) devices, mainly due to static magnetic fields (SMFs). Here, we ascertain the biological effects of chronic exposure to SMFs from MRI devices on the bone quality using rats exposed to SMFs in MRI examining rooms. Eighteen Wistar albino male rats were randomly assigned to SMF exposure (A), sham (B), and control (C) groups. Group A rats were positioned within 50 centimeters of the bore of the magnet of 1.5 T MRI machine during the nighttime for 8 weeks.

We collected blood samples for biochemical analysis, and bone tissue samples for electron microscopic and histological analysis. The mean vitamin D level in Group A was lower than in the other groups (p = 0.002). The mean cortical thickness, the mean trabecular wall thickness, and number of trabeculae per 1 mm2 were significantly lower in Group A (p = 0.003). TUNEL assay revealed that apoptosis of osteocytes were significantly greater in Group A than the other groups (p = 0.005).

The effect of SMFs in chronic exposure is related to movement within the magnetic field that induces low-frequency fields within the tissues. These fields can exceed the exposure limits necessary to deteriorate bone microstructure and vitamin D metabolism.

Publication and source details

Original title: Chronic Exposure to Static Magnetic Fields from Magnetic Resonance Imaging Devices Deserves Screening for Osteoporosis and Vitamin D Levels: A Rat Model

Harun R. Gungor; Semih Akkaya; Nusret Ok; Aygun Yorukoglu; Cagdas Yorukoglu; Esat Kiter; Emin O. Oguz; Nazan Keskin; Gulcin A. Mete

International Journal of Environmental Research and Public Health · 2015

* Author to whom correspondence should be addressed; E-Mail: hrgungor@gmail.com; Tel.: +90-258-444-0728 (ext. 5670); Fax: +90-258-213-1034.© 2015 by the authors; licensee MDPI, Basel, Switzerland.2015https://creativecommons.org/licenses/by/4.0/This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution license (http://creativecommons.org/licenses/by/4.0/).

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-12T10:36:15.235852+00:00

DOI: 10.3390/ijerph120808919 · PMC4555256