Secondary relevance to vitamin D This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.
This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.
Why this paper is included
Supporting source evidence:
Standard calibration curves and correlation factors for each analyte. Compound | Method | Concentration Range (mg L−1) | Calibration Curve | Coefficient of Determination (r2): Cholecalciferol | II | 0.005 to 2.56 | y = (76 ± 1.11) × 10−4 x + (16.25 ± 1.15) × 10−2 | 0.9998
Source: Results table. View original paper
Relevance classification does not establish study quality, causation or editorial approval.
Study design Study design awaiting verification.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.
Meta-analysis unclear · Blinding unclear / not reported · Research setting awaiting verification
How this paper was classified
Automatic source-based classification; awaiting editorial verification. This is not a quality score.
What the study types mean
- Systematic review
- Uses explicit methods to identify, assess and summarise research on a defined question.
- Scoping review
- Maps the extent and characteristics of research on a topic.
- Narrative review
- Discusses existing research; systematic-review methods have not been established by this classification.
- Review / evidence synthesis
- Reviews existing research; the exact review methods need further assessment.
- Randomised controlled trial
- Assigns participants or groups to comparison interventions by chance.
- Non-randomised intervention study
- Examines an intervention without random allocation.
- Cohort study
- Examines exposures and outcomes over time within a defined group.
- Case-control study
- Compares people with an outcome against people without it, examining exposures.
- Cross-sectional study
- Examines a population at a particular point in time.
- Observational study
- Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
- Case report
- Describes an individual case.
- Case series
- Describes a group of individual cases.
- Secondary analysis
- Analyses existing study data; this paper is not automatically another independent trial.
- Laboratory study
- Investigates biological processes in a laboratory setting.
- Qualitative study
- Examines experiences or meanings using qualitative methods.
- Genetic instrumental-variable study
- Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
- Study protocol
- Describes planned methods and is not evidence that the planned study has reported results.
- Multiple reported designs
- More than one design is explicitly reported; examine the supporting methods.
- Study design awaiting verification
- The available source does not establish a sufficiently clear study design.
Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.
Abstracts
Comparative Study for the Determination of Fat-Soluble Vitamins in Rice Cereal Baby Foods Using HPLC-DAD and UHPLC-APCI-MS/MS
Study design awaiting verification · Foods · 2021
Original publication title
Comparative Study for the Determination of Fat-Soluble Vitamins in Rice Cereal Baby Foods Using HPLC-DAD and UHPLC-APCI-MS/MS
© 2021 by the authors.
Original publication · Publisher record · CC BY 4.0
Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.
At a glance
What does the authors’ abstract report?
Two liquid chromatographic systems, one coupled to atmospheric pressure chemical ionization and tandem mass spectrometric methods (UHPLC-APCI-MS/MS) and the other a high-performance liquid chromatographic coupled to diode array detector (HPLC-DAD) were used to develop and validate methods for the simultaneous determination of fat-soluble vitamins A, D3 and E in rice cereal baby foods. The chromatographic separation was performed on C18 columns with a mixture of methanol-acetonitrile as mobile phase for all methods. The extraction of fat-soluble vitamins included enzymatic hydrolysis with α-amylase, saponification, extraction with petroleum ether or n-hexane and purification with silica cartridge (only for vitamin D3).
Quantification of vitamin D3 and E through UHPLC-APCI-MS/MS was performed by the use of internal standards (IS) D3-d3 and E-d6, respectively, while IS was not used for vitamin A. The methods were optimized and validated in terms of linearity, precision, trueness, limits of detection and quantification. The recoveries were in the range of 85.0 to 107% for retinol, 92.0 to 105% for α-tocopherol and 95.2 to 106% for cholecalciferol and the %RSD (Relative Standard Deviation) values ranged from 6.4% to 15%. The evaluation of the methods was also conducted through the estimation of uncertainties, the application in commercial samples and the participation in a proficiency test
Authors’ abstract
Two liquid chromatographic systems, one coupled to atmospheric pressure chemical ionization and tandem mass spectrometric methods (UHPLC-APCI-MS/MS) and the other a high-performance liquid chromatographic coupled to diode array detector (HPLC-DAD) were used to develop and validate methods for the simultaneous determination of fat-soluble vitamins A, D3 and E in rice cereal baby foods. The chromatographic separation was performed on C18 columns with a mixture of methanol-acetonitrile as mobile phase for all methods. The extraction of fat-soluble vitamins included enzymatic hydrolysis with α-amylase, saponification, extraction with petroleum ether or n-hexane and purification with silica cartridge (only for vitamin D3).
Quantification of vitamin D3 and E through UHPLC-APCI-MS/MS was performed by the use of internal standards (IS) D3-d3 and E-d6, respectively, while IS was not used for vitamin A. The methods were optimized and validated in terms of linearity, precision, trueness, limits of detection and quantification. The recoveries were in the range of 85.0 to 107% for retinol, 92.0 to 105% for α-tocopherol and 95.2 to 106% for cholecalciferol and the %RSD (Relative Standard Deviation) values ranged from 6.4% to 15%. The evaluation of the methods was also conducted through the estimation of uncertainties, the application in commercial samples and the participation in a proficiency test
Publication and source details
Original title: Comparative Study for the Determination of Fat-Soluble Vitamins in Rice Cereal Baby Foods Using HPLC-DAD and UHPLC-APCI-MS/MS
Maria Katsa; Natalia Papalouka; Theodora Mavrogianni; Irene Papagiannopoulou; Marios Kostakis; Charalampos Proestos; Nikolaos S. Thomaidis
Foods · 2021
* Correspondence: ntho@chem.uoa.gr; Tel.: +30-210-7274317© 2021 by the authors.2021https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).Repository JATS snapshot; version as supplied
Source retrieved: 2026-11-11T14:03:47.226697+00:00
DOI: 10.3390/foods10030648 · PMC8003111