Vitamin D3 for Life. Live Enlightened.

Research libraryVitamin D3 For Life
Study design and methods

Secondary relevance to vitamin D This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.

This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.

Why this paper is included

Supporting source evidence:

Background characteristics of the study participants. Variables | All patients (N = 119) | Non-osteoporosis (n = 70) | Osteoporosis (n = 49) | p value — Vitamin D (%) | 58.8 | 57.1 | 61.3 | 0.90

Source: Results table. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Study design awaiting verification.

Study design awaiting verification

The available source does not establish a sufficiently clear study design.

Meta-analysis unclear · Blinding unclear / not reported · Human research reported

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

This study retrospectively enrolled adult patients aged ≥18 years who had been receiving maintenance hemodialysis for ≥6 months and underwent plain abdominal CT and DEXA scans of the lumbar spine and femoral neck within the same week from April 2019 and March 2021 at Matsunami General Hospital, Kasamatsu, Gifu.

Source: Methods.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Full studies

Computed tomography-measured trabecular attenuation at first lumbar vertebra as a surrogate marker of bone mineral density and osteoporosis in patients undergoing hemodialysis

Study design awaiting verification · Renal Failure · 2026

Original publication title

Computed tomography-measured trabecular attenuation at first lumbar vertebra as a surrogate marker of bone mineral density and osteoporosis in patients undergoing hemodialysis

Takahiro Yajima; Ai Kurisawa; Maiko Arao

© 2026 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group.

Original publication · Publisher record · CC BY 4.0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

At a glance

Study background

What background does the paper provide?

Osteoporosis is a bone disorder characterized by decreased bone strength, which adversely affects bone quantity and quality and increasing fracture risk. The Kidney Disease: Improving Global Outcomes (KDIGO) Controversies Conference introduced chronic kidney disease (CKD)-associated osteoporosis as a new conceptual framework within CKD–mineral and bone disorders [1]. The occurrence of fractures is higher in patients with CKD than in the general population due to both CKD-specific and traditional risk factors [1,2]. Traditional risk factors include age and menopause, whereas CKD-specific risk factors include disturbances in mineral metabolism, uremic toxins, immune (systemic inflammation), endocrine (hyperparathyroidism and vitamin D deficiency), and neurohormonal disturbances, as well as a long dialysis duration [1,2].

Moreover, patients with CKD often have secondary risk factors for osteoporosis, such as hypogonadism, glucocorticoid use, diabetes mellitus, low body mass index (BMI), and malnutrition [1–3]. Because bone fractures are associated with a high risk of cardiovascular events and mortality [4–7], therefore, preventing osteoporosis is crucial in patients undergoing hemodialysis.

In patients with CKD, a history of fragility fractures or T-scores < −2.5 must be considered indicative of osteoporosis, regardless of disturbances in mineral metabolism [8]. Bone mineral density (BMD) is typically measured to assist in diagnosing and monitoring osteoporosis using dual-energy X-ray absorptiometry (DEXA). A Japanese cohort study revealed the association between a decreased BMD and an increased fracture risk in patients undergoing hemodialysis [9]. Thus, guidelines for CKD–mineral and bone disorders recommend BMD assessment in patients undergoing hemodialysis [10].

However, not all patients undergo DEXA. Recently, opportunistic assessment of trabecular attenuation values in vertebrae using routine abdominal computed tomography (CT) has gained attention as an increasingly valuable method for identifying high-risk patients for osteoporosis [11–26]. Among these approaches, average CT-attenuation values (in Hounsfield units, HU) at the first lumbar vertebral level (L1 CT-attenuation) has emerged as a reliable and clinically practical surrogate for BMD. Trabecular attenuation measured at the L1 level is as accurate as, or more accurate than, measurements at other levels for predicting osteoporosis [11].

Additionally, the L1 level is easy to identify and is included in standard chest and abdominal CT scans [11]. Thus, L1-level measurements have been widely used in studies of prior opportunistic osteoporosis screening [11–26]. Pickhardt et al. performed a cross-sectional analysis of patients who underwent abdominal CT and DEXA within 6 months and first proposed practical HU thresholds: < 110 HU strongly indicates osteoporosis, whereas > 160 HU indicates that osteoporosis is unlikely [11].

Thereafter, various cutoffs have been reported in different ethnic and clinical settings [15,22,24–26]. However, to our knowledge, the relationship between L1 CT-attenuation, BMD, and osteoporosis prediction has not been examined in patients on hemodialysis. Thus, the present study aimed to examine the association among L1 CT-attenuation, BMD, and osteoporosis in these patients.

Source: Introduction Source: Introduction

Study methods

What methods does the paper describe?

Participants and inclusion and exclusion criteria

This study retrospectively enrolled adult patients aged ≥18 years who had been receiving maintenance hemodialysis for ≥6 months and underwent plain abdominal CT and DEXA scans of the lumbar spine and femoral neck within the same week from April 2019 and March 2021 at Matsunami General Hospital, Kasamatsu, Gifu. At our institution, CT and DEXA scans are included in the annual checkup. Patients with bilateral femoral neck fractures and bedridden patients were excluded. We also excluded patients with symptomatic lumbar compression fractures at the L1 level or those who had undergone surgery, as L1 CT-attenuation or lumbar spine BMD could not be measured appropriately in these cases.

This study was conducted in accordance with the Declaration of Helsinki and was approved by the institutional review board of Matsunami General Hospital (‘Ethics Committee of Matsunami General Hospital Medical’; approval number: No. 643). The informed consent requirement was waived because the present retrospective study used chart reviews of previously performed CT and DEXA examinations.

Collection of clinical data

We retrieved all patient information from medical charts, including age, sex, BMI, smoking and alcohol consumption (self-reported current alcohol use), underlying kidney disease (nephrosclerosis, chronic glomerulonephritis, diabetic kidney disease, and others), history of diabetes mellitus, duration of hemodialysis, and medications, including a phosphorus binder (especially calcium-containing), oral or parenteral vitamin D, oral or parenteral calcium-sensing receptor agonists, and osteoporosis therapies (bisphosphonate, romosozumab, and selective estrogen receptor modulator). A blood test was performed in the supine position before the initiation of hemodialysis on Mondays or Tuesdays.

Laboratory data and findings of CT and DEXA performed within 1 month were used for data analyses.

Measurement of L1 CT-attenuation values

Non-enhanced abdominal CT was performed using a multidetector CT scanner (LightSpeed Series; GE HealthCare, Chicago, IL, USA). All CT scans were performed at 120 kVp with a 5 mm slice thickness and a 512 × 512 matrix. The in-plane pixel spacing, derived from the DICOM metadata, ranged from approximately 0.51 to 0.97 mm, depending on the field of view. A single axial computed tomography (CT) slice through the center of the L1 vertebral body was selected at the pedicular level.

L1 was defined as the first non-rib-bearing vertebra. HU measurements were retrospectively assessed using a picture archiving and communication system (XTREK View; J-MAC System, Inc., Sapporo, Japan) with a region-of-interest (ROI) tool. For each patient, the ROI was manually placed over the trabecular bone of L1, with the maximum possible elliptical diameter, avoiding the vertebral cortex and the posterior venous plexus, as previously reported (Figure 1) [11,19,26]. The mean CT value (HU) within the ROI was defined as the L1 CT-attenuation.

An example of L1 CT-attenuation measurement is shown in Figure 1. Two examiners, MA and TY, measured L1 CT-attenuation. They could vary the selection of an axial slice at the L1 level and the placement and size of the ROI within the trabecular bone. Both examiners were masked to patients’ clinical information, including DXA results and laboratory data. Each observer was also masked to the other’s measurements.

Figure 1.

An example of measuring L1 CT-attenuation value.

A single axial computed tomography (CT) slice of the first lumbar (L1) vertebral body was selected at the pedicular level. The region of interest (ROI) tool was used. The ROI was set to the maximum possible elliptical diameter without including the vertebral cortex or the basivertebral venous plexus. The average CT value within the ROI was defined as L1 CT-attenuation. In this case, the L1 CT-attenuation was 104.37 HU.

Axial abdominal CT scan with ROI highlighting structures, showing HU values: mean 104.37, min 41, max 169, standard deviation 18.25.This axial CT scan of the abdomen displays internal structures in grayscale, including organs like the liver, spleen, and kidneys. An irregular oval region of interest (ROI) is centered over a vertebral body. The quantitative metrics indicate a mean Hounsfield Unit (HU) of 104.37, a min of 41 HU, and a max of 169 HU, with a standard deviation of 18.25 HU. Anatomical orientation is marked with "R" and "L" for right and left. The varying tissue densities are rendered in different shades of gray, enhancing the visibility of the structures.Figure image at the original source — open the original paper. This file is not included in this text import.

BMD measurement using DEXA

BMDs measurements at the proximal femoral neck and lumbar vertebrae were assessed using standard techniques on a DEXA scanner with Smart BMD software (SONIALVISION G4; Shimadzu Corporation, Kyoto, Japan). BMD is expressed in g/cm2. Osteoporosis was defined as a low DEXA T-score of < −2.5 at either the femoral neck or lumbar spine, according to the WHO criteria [27,28].

Statistical analyses

Non-normally distributed variables are described as medians and interquartile ranges and normally distributed variables by means and standard deviations. Intra- and inter-rater reproducibility of L1 CT-attenuation values were evaluated using the intraclass correlation coefficient (ICC) and 95% confidence interval (CI). ICC >0.9 was considered excellent for reproducibility and clinical acceptability. The agreement was further evaluated using a Bland–Altman analysis. Continuous variables were compared using the t-test or the Wilcoxon signed-rank test and categorical variables using the chi-squared test between patients with and without osteoporosis.

The correlations among L1 CT-attenuation and T-scores of the femoral neck and lumbar spine were shown with scatter plots. Correlation between L1 CT-attenuation and femoral neck or lumbar spine BMD was assessed with Pearson’s correlation coefficient. Before applying linear models, the linearity between L1 CT-attenuation and BMD was visually assessed using scatter plots. Univariable regression analysis was performed to evaluate associations between baseline variables and L1 CT-attenuation. Thereafter, multivariable regression analysis was performed with a model that included all significant variables from the univariable regression analysis.

BMDs at the femoral neck and at the lumbar spine were analyzed in separate models to avoid multicollinearity arising from their strong correlation. We assessed multicollinearity using variance inflation factors (VIFs). The optimal cutoff value of L1 CT-attenuation for diagnosing osteoporosis was determined using receiver operating characteristic (ROC) curve analysis with the Youden index. In addition, we determined the L1 CT-attenuation thresholds that demonstrated high sensitivity (≥ 90%) and specificity (≥ 90%) for diagnosing osteoporosis. To account for potential non-linear relationships and to further assess the robustness of the association, logistic regression analyses were performed with osteoporosis (defined as a T-score < −2.5) as the outcome.

Non-linearity was evaluated using restricted cubic splines with three knots. Multivariable models were adjusted for clinically relevant covariates, including age, sex, and BMI.

Furthermore, unadjusted and sex–age–BMI-adjusted odds ratios (ORs) and 95% CIs for L1 CT-attenuation values were evaluated to assess their association with osteoporosis. Most variables were available for all participants; however, 25(OH)D levels were measured in a subset of patients (n = 90) because of the retrospective design of the present study. Analyses involving this variable were conducted using the available data. If minor missing data were present, a complete case analysis was performed. We used SPSS Statistics for Windows, version 31 (IBM Corp., Armonk, NY, USA) for statistical analyses and JMP®, version 19 (JMP Statistical Discovery LLC, Cary, NC, USA).

A p-value < 0.05 was considered significant.

Source: Methods Source: Methods Source: Methods Source: Methods Source: Methods

Background characteristics of study participants

Results: Background characteristics of study participants

We screened 128 Japanese patients receiving maintenance hemodialysis and excluded two patients with bilateral fractures of the femoral neck (bedridden status) and 7 patients with symptomatic vertebral fractures. We included 119 patients (mean age: 67.2 years; men: 63%; BMI: 22.4 kg/m2), of whom 49 patients were diagnosed with osteoporosis. Baseline characteristics are summarized in Table 1.

Table 1.

Background characteristics of the study participants.

VariablesAll patients (N = 119)Non-osteoporosis (n = 70)Osteoporosis (n = 49)p value
Age (year)67.2 ± 12.764.7 ± 13.070.9 ± 11.30.0076
Male (%)63.082.934.7<0.0001
Body mass index (kg/m2)22.4 ± 3.923.8 ± 3.820.5 ± 3.2<0.0001
Smoking (%)22.722.922.40.96
Alcohol consumption (%)28.632.922.40.21
Underlying kidney disease   0.74
Diabetic nephropathy41.244.336.7 
Chronic glomerulonephritis26.125.726.5 
Nephrosclerosis23.522.924.5 
Others9.27.112.2 
Diabetes mellitus (%)43.648.636.70.20
Hemodialysis duration (years)3.3 (1.7–6.4)3.5 (2.0–6.2)3.3 (1.3–6.8)0.57
Medications (%)    
 Calcium-containing phosphorous binder (%)50.460.036.70.012
 Vitamin D (%)58.857.161.30.90
  Oral (%)7.67.18.2 
  Parenteral (%)51.250.053.1 
 Calcium-sensing receptor agonists (%)13.410.018.40.24
  Oral (%)7.67.18.2 
  Parenteral (%)5.92.910.2 
 Therapy for osteoporosis (%)12.6030.6<0.0001
  Bisphosphonate (%)4.2010.2 
  Romosozumab (%)7.6018.4 
  Selective estrogen receptor modulator (%)0.802.0 
Serum albumin (g/dL)3.4 ± 0.33.4 ± 0.33.3 ± 0.30.14
Total cholesterol (mg/dL)145 ± 38140 ± 42153 ± 320.063
Serum creatinine (mg/dL)9.4 ± 3.210.0 ± 3.58.7 ± 2.40.029
Calcium (mg/dL)8.6 ± 0.68.6 ± 0.68.5 ± 0.70.50
Phosphorus (mg/dL)4.6 ± 1.14.5 ± 1.24.7 ± 1.10.46
Intact parathyroid hormone (pg/mL)135 (63–207)134 (63–191)143 (67–243)0.23
25(OH)D (ng/mL) (n = 90)11.9 ± 5.6 (n = 90)12.2 ± 5.3 (n = 56)11.4 ± 6.1 (n = 34)0.52
C-reactive protein (mg/dL)0.10 (0.03–0.28)0.12 (0.03–0.36)0.08 (0.04–0.19)0.35
Bone mineral density at the femoral neck (g/cm2)0.70 ± 0.110.78 ± 0.080.60 ± 0.06 
Femoral neck T-score−2.11 ± 1.03−1.46 ± 0.73−3.04 ± 0.58 
Bone mineral density at the lumbar spine (g/cm2)1.02 ± 0.181.11 ± 0.130.88 ± 0.15 
Lumber spine T-score−1.19 ± 1.24−0.54 ± 0.93−2.13 ± 1.00 
CT-measured trabecular attenuation at the L1 vertebral level (Hounsfield units)110.3 ± 41.0122.3 ± 40.293.1 ± 35.9<0.0001

CT, computed tomography.

Source: Background characteristics of study participants Source: Background characteristics of study participants

Reproducibility of L1 CT-attenuation measurements

Results: Reproducibility of L1 CT-attenuation measurements

Intra- and inter-rater reproducibility and agreement of L1 CT-attenuation measurements were assessed in 30 randomly selected patients using ICCs and Bland–Altman analysis. Intra-rater ICCs were 0.999 (95% CI: 0.998–0.999) for MA and 0.999 (95% CI: 0.998–1) for TY, and the inter-rater (MA and TY) ICC was 0.999 (95% CI: 0.997–0.999). Bland–Altman analysis demonstrated good intra-rater and inter-rater agreement (Figure 2).

Figure 2.

Bland–Altman analysis to assess agreement of L1 computed tomography (CT)-attenuation values.

Two investigators (MA and TY) measured L1 CT-attenuation values and described the differences and 95% confidence intervals for the plots. Intra-rater agreement of MA (a) and that of TY (b), and inter-rater agreement between MA and TY (c) were shown.

Three scatter plots showing L1 CT-attenuation trial differences versus their averages, with horizontal reference lines at zero.The figure presents three scatter plots (a, b, c) displaying L1 CT-attenuation differences for various trials. - **Panel a:** L1 CT-attenuation trial 2 minus trial 1, points cluster near zero; p-value is 0.46. - **Panel b:** Similar comparison with p-value 0.81, points also close to zero. - **Panel c:** Displays MA versus TY differences; p-value is 0.47, points concentrated around zero. Each plot has dotted lines at the 95% limits of agreement.Figure image at the original source — open the original paper. This file is not included in this text import.
Source: Reproducibility of L1 CT-attenuation measurements Source: Reproducibility of L1 CT-attenuation measurements

Association between L1 CT-attenuation and bone mineral density of the femoral neck and lumbar spine

Results: Association between L1 CT-attenuation and bone mineral density of the femoral neck and lumbar spine

The positive correlation of T-scores between the femoral neck and the lumbar spine (Figure 3a), and the positive correlation between CT-measured trabecular attenuation at the L1 vertebral level and T-scores of either the femoral neck (Figure 3b) or lumbar spine (Figure 3c) were shown. Femoral neck and lumbar spine BMDs were significantly correlated (r = 0.598; p < 0.0001). Moreover, L1 CT-attenuation was significantly correlated with the femoral neck (r = 0.527; p < 0.0001) and lumbar spine (r = 0.368; p < 0.0001) BMDs (Table 2).

L1 CT-attenuation was significantly correlated with age, diabetes mellitus, use of calcium-containing phosphorus binder or therapy for osteoporosis, and serum creatinine levels in the univariable regression analysis (Table 2). In addition, L1 CT-attenuation was independently associated with the femoral neck (β = 0.319; p = 0.0003) and lumbar spine (β = 0.265; p = 0.0006) BMDs in the multivariable regression analysis (Table 3).

Figure 3.

Correlation between CT-measured trabecular attenuation at the L1 vertebral level and T-scores of the femoral neck and lumbar spine.

The correlation of T-scores between the femoral neck and the lumbar spine (a), and the correlation between CT-measured trabecular attenuation at the L1 vertebral level and T-scores of either the femoral neck (b) or lumbar spine (c) were shown. The horizontal and vertical reference lines indicate osteoporosis thresholds according to DXA criteria (T-score < −2.5).

Scatterplots showing relationships between femoral neck and L2-L4 T-scores (Panel a, r=0.598), CT attenuation at L1 vs. femoral neck T-scores (Panel b, r=0.527), and CT attenuation at L1 vs. L2-L4 T-scores (Panel c, r=0.368).Panel a features a scatterplot with femoral neck T-scores (y-axis) vs. L2-L4 T-scores (x-axis), showing a positive correlation (r=0.598). Panel b plots CT attenuation at L1 (y-axis) vs. femoral neck T-scores (x-axis), indicating a positive trend (r=0.527). Panel c presents a scatterplot of CT attenuation at L1 vs. L2-L4 T-scores, depicting a weaker positive correlation (r=0.368). Each panel includes reference lines at -2.5 T-scores.Figure image at the original source — open the original paper. This file is not included in this text import.
Table 2.

Associations between CT-measured trabecular attenuation at the L1 vertebral level and baseline variables.

VariablesUnivariable (r)p value
Age −0.579<0.0001
Sex (male)0.0350.71
Body mass index0.1700.065
Smoking0.0800.39
Alcohol0.1030.26
Diabetes mellitus 0.2380.0092
Hemodialysis vintage0.1460.11
Medications  
 Calcium-containing phosphorus binder0.1950.033
 Vitamin D0.0970.29
 Calcium-sensing receptor agonists−0.1480.11
 Therapy for osteoporosis−0.1940.034
Serum albumin0.1480.11
Total cholesterol−0.0640.49
Serum creatinine 0.2360.0097
Calcium0.1380.14
Phosphorus0.0570.54
Intact parathyroid hormone−0.1020.27
25(OH)D (n = 90)−0.1470.17
C-reactive protein−0.0540.56
Bone mineral density at the femoral neck 0.527<0.0001
Femoral neck T-score 0.527<0.0001
Bone mineral density at the lumbar spine 0.368<0.0001
Lumber spine T-score 0.368<0.0001

CT, Computed tomography.

Table 3.

Associations between CT-measured trabecular attenuation at the L1 vertebral level and BMD measured at the femoral neck and lumbar spine.

VariablesMultivariable model including femoral neck BMD (β)p valueVIFMultivariable model including lumbar spine BMD (β)p valueVIF
Age−0.486<0.00011.66−0.596<0.00011.42
Diabetes mellitus0.1520.0341.060.1280.0791.11
Calcium-containing phosphorus binder0.0240.741.130.0210.781.13
Therapy for osteoporosis−0.0220.781.37−0.0940.201.14
Serum creatinine0.0780.351.510.1070.211.49
BMD at the femoral neck 0.3190.00031.57–– 
BMD at the lumbar spine –– 0.2650.00061.18

CT, computed tomography; BMD, bone mineral density; VIF, variation inflation factor.

Source: Association between L1 CT-attenuation and bone mineral density of the femoral neck and lumbar spine Source: Association between L1 CT-attenuation and bone mineral density of the femoral neck and lumbar spine Source: Association between L1 CT-attenuation and bone mineral density of the femoral neck and lumbar spine Source: Association between L1 CT-attenuation and bone mineral density of the femoral neck and lumbar spine

L1 CT-attenuation cutoffs for diagnosing osteoporosis

Results: L1 CT-attenuation cutoffs for diagnosing osteoporosis

The ROC-derived optimal cutoff for L1 CT-attenuation was 109.3 HU (area under the curve [AUC], 0.705; sensitivity, 0.735; specificity, 0.643; p < 0.0001) (Figure 4). An L1 CT-attenuation threshold of 71.3 HU achieved ≥90% specificity, whereas a threshold of 151.1 HU achieved ≥90% sensitivity for diagnosing osteoporosis.

Figure 4.

Receiver operating characteristic (ROC) analysis of CT-measured trabecular attenuation at the L1 vertebral level for osteoporosis diagnosis. Osteoporosis was defined as a low DEXA-measured T-score of < −2.5. T-scores for the femoral neck and lumbar spine were evaluated, and the lower value among these scores was used.

A ROC curve showing sensitivity against 1-specificity, with values from 0 to 1 on both axes.The figure depicts a receiver operating characteristic (ROC) curve on a Cartesian grid. The x-axis, labeled "1 - Specificity," ranges from 0 to 1, while the y-axis, labeled "Sensitivity," also spans from 0 to 1. A black staircase curve illustrates sensitivity rising as 1-specificity increases. It begins at the origin (0,0) and reaches a maximum sensitivity near 1 at (1,1), surpassing a diagonal reference line that indicates baseline performance. Gridlines assist in interpreting the values across both axes.Figure image at the original source — open the original paper. This file is not included in this text import.
Source: L1 CT-attenuation cutoffs for diagnosing osteoporosis Source: L1 CT-attenuation cutoffs for diagnosing osteoporosis

Association between L1 CT-attenuation and osteoporosis

Results: Association between L1 CT-attenuation and osteoporosis

In logistic regression analyses with restricted cubic splines, L1 CT-attenuation was significantly associated with osteoporosis both before and after adjusting for covariates (p = 0.0012 and p = 0.0041, respectively). There was no evidence of non-linearity in the association (p for non-linearity = 0.82 in the unadjusted model and p = 0.52 in the adjusted model), indicating that the relationship between L1 CT-attenuation and osteoporosis can be adequately described as linear (Figure 5).

Figure 5.

Association between L1 CT-attenuation and osteoporosis using restricted cubic spline analysis.

The curve shows the adjusted log odds ratio for osteoporosis by L1 CT-attenuation, with 95% confidence intervals shown as gray-shaded areas. The model was adjusted for age, sex, and body mass index. No significant non-linearity was observed (p for non-linearity = 0.52), supporting a linear relationship.

Line graph depicting a decreasing trend in log odds ratio as L1 CT-attenuation increases, with a shaded confidence interval.The graph illustrates the relationship between L1 CT-attenuation (x-axis, 60 to 160) and log odds ratio (y-axis, -1 to 4). A downward trending black line indicates a decrease in log odds ratio with increasing L1 CT-attenuation. Surrounding the line, a shaded gray area represents the confidence interval, showing variability which narrows at higher L1 CT-attenuation values. In the top right corner, the p-value for non-linearity is noted as 0.52.Figure image at the original source — open the original paper. This file is not included in this text import.
Source: Association between L1 CT-attenuation and osteoporosis Source: Association between L1 CT-attenuation and osteoporosis

Unadjusted and adjusted ORs of L1 CT-attenuation for diagnosing osteoporosis

Results: Unadjusted and adjusted ORs of L1 CT-attenuation for diagnosing osteoporosis

The unadjusted OR for diagnosing osteoporosis per 10-HU-increase in L1 CT-attenuation was 0.817 (95% CI, 0.722–0.904; p < 0.0001). Additionally, the sex–age–BMI-adjusted OR for diagnosing osteoporosis per 10-HU-increase in L1 CT-attenuation was 0.73 (95% CI, 0.592–0.868; p = 0.0003).

Source: Unadjusted and adjusted ORs of L1 CT-attenuation for diagnosing osteoporosis

Discussion

To the best of our knowledge, this is the first study to examine the association among L1 CT-attenuation, BMD, and osteoporosis in Japanese patients on hemodialysis. L1 CT-attenuation was independently associated with the femoral neck and lumbar vertebral BMD. The optimal L1 CT-attenuation cutoff for diagnosing osteoporosis was 109.3 HU, which demonstrated moderate diagnostic accuracy (AUC: 0.705). Moreover, thresholds of ≥151.1 HU exhibited over 90% sensitivity, whereas a threshold of 71.3 HU or lower exhibited over 90% specificity for distinguishing between patients with and without osteoporosis.

After adjusting for age, sex, and BMI, a low L1 CT-attenuation value was independently associated with osteoporosis. Therefore, CT screening may facilitate the early detection and intervention for osteoporosis in this population.

In this study, we measured L1 CT-attenuation using an abdominal CT image for kidney cancer screening. Two masked investigators evaluated L1 CT-attenuation in 30 randomly selected patients, demonstrating excellent reproducibility and agreement of L1 CT-attenuation measurements, as previously reported in healthy individuals [29]; this finding indicates that L1 CT-attenuation may be a clinically acceptable biomarker in patients on hemodialysis.

We examined the association between L1 CT-attenuation and BMD of the femoral neck and lumbar spine. Previous studies have reported stronger correlations of L1 CT-attenuation with lumbar spine BMD than with femoral neck BMD (r = 0.552 vs. 0.349 and 0.726 vs. 0.503, respectively) [18,30]. Conversely, in this study, the correlation between L1 CT-attenuation and femoral neck BMD (r = 0.527) was stronger than that between L1 CT-attenuation and lumbar spine BMD (r = 0.368).

This may reflect that DEXA findings incorporate posterior spinal elements, which can lead to inaccuracies in cases of previous lumbar surgery, scoliosis, or severe spinal degeneration [31,32]. In addition, the lumbar spine BMD may be overestimated in patients with CKD due to vascular calcification [33,34]. Although we excluded patients with a history of L1 vertebral fracture or lumbar surgery, the BMD measurement of the lumbar vertebra might have been less accurate than that of the femoral neck owing to lumbar degeneration or vascular calcification.

Moreover, the number of patients with osteoporosis with a T-score of femoral neck < − 2.5 was higher than the number of patients with a T-score of lumbar spine < − 2.5 (N = 46 vs. N = 20, respectively; details not shown). Because L1 CT-attenuation was derived from trabecular bone regions, the association between vertebral cortical bone and BMD could not be assessed in the present study. In CKD-mineral and bone disorders, trabecular bone is closely linked to changes in bone turnover, whereas cortical bone abnormality contributes to bone fragility and fracture risk.

Notably, cortical bone involvement is prominent, with increased cortical porosity representing a major skeletal abnormality in secondary hyperparathyroidism [35]. Thus, this pathophysiology might partly explain why L1 CT-attenuation correlated more strongly with femoral neck BMD than with lumbar spine BMD. However, whether the lumbar spine’s cortical bone is similarly affected by secondary hyperparathyroidism as the femoral neck’s cortical bone remains unknown.

Importantly, L1 CT-attenuation was independently associated with DEXA-measured BMDs of the femoral neck and lumbar vertebrae after adjusting for age, diabetes mellitus, use of calcium-containing phosphorus binders or osteoporosis therapy, and creatinine levels. These findings indicate that L1 CT-attenuation is a useful marker of BMD in patients undergoing hemodialysis. However, we have to acknowledge that some variables (i.e., age, BMD, and osteoporosis therapy) may not be fully independent in the multivariable regression models. We assessed multicollinearity using VIFs and observed no significant collinearity among the included variables.

Age is a well-known determinant of both BMD and L1 CT-attenuation values; therefore, age was included in the model to adjust for its confounding effect on the association between L1 CT-attenuation and BMD. Regarding osteoporosis therapy, we acknowledge that it is not independent of BMD, as it is typically initiated in patients with decreased BMD. For this reason, osteoporosis therapy was included as a covariate to account for its potential modifying effect rather than assuming independence. To assess this, we added a sensitivity analysis assessing the associations between L1 CT-attenuation and BMDs at the femoral neck and lumbar spine in patients who did not receive osteoporosis therapy (N = 104).

Results were similar to those in the primary analyses: L1 CT-attenuation was independently associated with BMD at the femoral neck (β = 0.287, p = 0.0006) and with BMD at the lumbar spine (β = 0.254, p = 0.0012) (details not shown in the manuscript). Moreover, L1 CT-attenuation was independently associated with diabetes mellitus in the model including femoral neck BMD, but not in the model including lumbar spine BMD. The lumbar spine is predominantly trabecular, whereas the femoral neck contains a relatively higher proportion of cortical bone in addition to trabecular bone.

Diabetes mellitus affects bone vulnerability through site-specific mechanisms with an increased cortical porosity in cortical bone rather than deterioration of trabecular microarchitecture in trabecular bone [36]. These differences in bone composition may have contributed to the observed discrepancy between models. In addition, given the relatively small sample size, the lack of significance in the model including lumbar spine BMD may be attributable to limited statistical power.

Thresholds for L1 CT-attenuation in diagnosing osteoporosis, including diagnostic performance and clinical interpretation, have been reported previously. Pickhardt et al. first reported an ROC-derived optimal threshold for L1 CT-attenuation of 135 HU with good diagnostic accuracy (AUC: 0.83) in a large USA-based cohort study [11]. Subsequently, many studies have shown that the optimal thresholds for osteoporosis diagnosis range from 95 to 180 HU, with moderate to good diagnostic accuracy (AUC 0.64–0.86) [12–23]. However, no such reports were found for the Japanese population; therefore, we could not compare our results with those of the general Japanese population.

Nevertheless, within the Asian population, the optimal L1 CT-attenuation thresholds for osteoporosis diagnosis ranged from 95 to 136 HU, with AUCs of 0.74–0.86 [16–18,21,23]. In the present study, the optimal L1 CT-attenuation cutoff value for osteoporosis diagnosis was 109.3 HU (AUC: 0.705). This value was remarkably consistent with the thresholds reported in previous studies on Asian populations and had an acceptable discriminatory ability for osteoporosis diagnosis. Moreover, Pickhardt et al. proposed thresholds of < 110 HU for > 90% specificity and > 160 HU for > 90% sensitivity to discriminate between patients with and without osteoporosis [11].

Subsequently, several studies have reported different thresholds for osteoporosis diagnosis: 73–104 HU for > 90% specificity and 139–180 HU for > 90% sensitivity [15,22,24–26]. In this study, we identified clinically meaningful thresholds of ≤ 71.3 HU for > 90% specificity and ≥ 151.1 HU for > 90% sensitivity, which may be useful for screening and risk stratification of osteoporosis in practice.

Differences in cutoff values and diagnostic accuracies have been reported for various cohorts. These differences may reflect factors such as osteoporosis diagnosis, imaging modalities (including CT and DEXA), interval between CT and BMD measurements, and population characteristics (including race, sex, age, and background diseases). In this study, osteoporosis was diagnosed according to the WHO diagnostic criteria: a T-score of less than −2.5 at the femoral neck or lumbar spine was considered osteoporosis [27,28]. We performed CT and DEXA analyses, which are widely used techniques in Japan.

Although in previous studies, the interval between CT and DEXA measurements varied (from 2 weeks to 2 years) [37], we performed CT and DEXA within the same week because they were part of a routine medical checkup for cancer screening at our hospital. Non-enhanced CT was performed at 120 kV to screen for renal cancer. CT attenuation is influenced by the kilovoltage, and these existing diagnostic thresholds are typically based on CT scans performed at 120 kV. A recent review reported that CT has higher diagnostic value for osteoporosis in Asian populations, particularly when non-enhanced CT is performed alone, participants are aged ≥ 65 years, and the proportion of women among the participants is high [38].

In this study, we enrolled Japanese patients undergoing hemodialysis who underwent non-enhanced CT; however, the patients were relatively young, and men outnumbered women. Patients undergoing hemodialysis represent a unique population characterized by profound disturbances in mineral metabolism, chronic inflammation, endocrine abnormalities, and accelerated bone loss [1,2]. Despite differences between our results and those of previous studies, the strength of the association between L1 CT-attenuation and BMD observed in our study was comparable to that reported in general population cohorts.

Additionally, the L1 CT-attenuation cutoffs for diagnostic performance and clinical interpretation in our study were comparable to those for the general population cohorts. Our findings may validate L1 CT-attenuation as a robust surrogate marker for BMD and a screening tool for osteoporosis in patients on hemodialysis. Furthermore, the excellent intra- and inter-rater reproducibility and agreement observed in this study support the feasibility of incorporating this measurement into routine clinical practice, potentially through automated, software-based analysis with artificial intelligence in the future [39,40].

In the present study, L1 CT-attenuation was significantly associated with osteoporosis. Importantly, analyses using restricted cubic splines showed no evidence of non-linearity, indicating that this association can be adequately described by a linear model. These findings support the validity of linear regression analyses and suggest that L1 CT-attenuation provides a consistent estimate of bone fragility risk across its observed range.

The present study has some limitations. First, it was a retrospective single-center study with only a small number of Japanese participants, which may limit the generalizability of the findings. In addition, our study population consisted of patients who underwent routine annual checkups, which may represent a relatively healthier subset of the hemodialysis population. This could introduce selection bias and also limit the generalizability of our findings to patients who do not undergo regular checkups. Second, because of the cross-sectional design, causal relationships cannot be established, and the possibility of reverse causation cannot be ruled out.

Third, the lack of internal or external validation, such as split-sample validation or an independent cohort, limits the external validity of our findings. Fourth, we cross-sectionally assessed L1 CT-attenuation and BMDs of femoral neck and lumbar spine at baseline; therefore, future fracture incidence and longitudinal changes in CT attenuation were not evaluated. Fifth, although L1 CT-attenuation provides valuable information on bone density, it cannot replace the comprehensive assessment of bone turnover or histological evaluation, which may be particularly relevant in CKD-related bone diseases.

Future prospective multicenter studies with larger, ethnically diverse cohorts are needed to validate these thresholds across different CT platforms; moreover, in these studies, the ability of L1 CT-attenuation to predict incident fractures can be examined in patients undergoing hemodialysis. Furthermore, automated CT-based bone assessment should be integrated into radiological workflows, which may further enhance the early detection of osteoporosis and improve patient outcomes.

In conclusion, L1 CT-attenuation was independently associated with BMD of the femoral neck and lumbar spine and may be a useful screening tool for osteoporosis in Japanese patients undergoing hemodialysis. Opportunistic evaluation of L1 CT-attenuation using abdominal CT scans is a valuable and cost-effective approach for identifying patients at a high risk of osteoporosis, thereby facilitating early intervention, and potentially reducing fracture-related morbidity in this vulnerable population.

Source: Discussion Source: Discussion Source: Discussion Source: Discussion Source: Discussion Source: Discussion Source: Discussion Source: Discussion Source: Discussion

Results

Background characteristics of study participants

We screened 128 Japanese patients receiving maintenance hemodialysis and excluded two patients with bilateral fractures of the femoral neck (bedridden status) and 7 patients with symptomatic vertebral fractures. We included 119 patients (mean age: 67.2 years; men: 63%; BMI: 22.4 kg/m2), of whom 49 patients were diagnosed with osteoporosis. Baseline characteristics are summarized in Table 1.

Table 1.

Background characteristics of the study participants.

VariablesAll patients (N = 119)Non-osteoporosis (n = 70)Osteoporosis (n = 49)p value
Age (year)67.2 ± 12.764.7 ± 13.070.9 ± 11.30.0076
Male (%)63.082.934.7<0.0001
Body mass index (kg/m2)22.4 ± 3.923.8 ± 3.820.5 ± 3.2<0.0001
Smoking (%)22.722.922.40.96
Alcohol consumption (%)28.632.922.40.21
Underlying kidney disease   0.74
Diabetic nephropathy41.244.336.7 
Chronic glomerulonephritis26.125.726.5 
Nephrosclerosis23.522.924.5 
Others9.27.112.2 
Diabetes mellitus (%)43.648.636.70.20
Hemodialysis duration (years)3.3 (1.7–6.4)3.5 (2.0–6.2)3.3 (1.3–6.8)0.57
Medications (%)    
 Calcium-containing phosphorous binder (%)50.460.036.70.012
 Vitamin D (%)58.857.161.30.90
  Oral (%)7.67.18.2 
  Parenteral (%)51.250.053.1 
 Calcium-sensing receptor agonists (%)13.410.018.40.24
  Oral (%)7.67.18.2 
  Parenteral (%)5.92.910.2 
 Therapy for osteoporosis (%)12.6030.6<0.0001
  Bisphosphonate (%)4.2010.2 
  Romosozumab (%)7.6018.4 
  Selective estrogen receptor modulator (%)0.802.0 
Serum albumin (g/dL)3.4 ± 0.33.4 ± 0.33.3 ± 0.30.14
Total cholesterol (mg/dL)145 ± 38140 ± 42153 ± 320.063
Serum creatinine (mg/dL)9.4 ± 3.210.0 ± 3.58.7 ± 2.40.029
Calcium (mg/dL)8.6 ± 0.68.6 ± 0.68.5 ± 0.70.50
Phosphorus (mg/dL)4.6 ± 1.14.5 ± 1.24.7 ± 1.10.46
Intact parathyroid hormone (pg/mL)135 (63–207)134 (63–191)143 (67–243)0.23
25(OH)D (ng/mL) (n = 90)11.9 ± 5.6 (n = 90)12.2 ± 5.3 (n = 56)11.4 ± 6.1 (n = 34)0.52
C-reactive protein (mg/dL)0.10 (0.03–0.28)0.12 (0.03–0.36)0.08 (0.04–0.19)0.35
Bone mineral density at the femoral neck (g/cm2)0.70 ± 0.110.78 ± 0.080.60 ± 0.06 
Femoral neck T-score−2.11 ± 1.03−1.46 ± 0.73−3.04 ± 0.58 
Bone mineral density at the lumbar spine (g/cm2)1.02 ± 0.181.11 ± 0.130.88 ± 0.15 
Lumber spine T-score−1.19 ± 1.24−0.54 ± 0.93−2.13 ± 1.00 
CT-measured trabecular attenuation at the L1 vertebral level (Hounsfield units)110.3 ± 41.0122.3 ± 40.293.1 ± 35.9<0.0001

CT, computed tomography.

Reproducibility of L1 CT-attenuation measurements

Intra- and inter-rater reproducibility and agreement of L1 CT-attenuation measurements were assessed in 30 randomly selected patients using ICCs and Bland–Altman analysis. Intra-rater ICCs were 0.999 (95% CI: 0.998–0.999) for MA and 0.999 (95% CI: 0.998–1) for TY, and the inter-rater (MA and TY) ICC was 0.999 (95% CI: 0.997–0.999). Bland–Altman analysis demonstrated good intra-rater and inter-rater agreement (Figure 2).

Figure 2.

Bland–Altman analysis to assess agreement of L1 computed tomography (CT)-attenuation values.

Two investigators (MA and TY) measured L1 CT-attenuation values and described the differences and 95% confidence intervals for the plots. Intra-rater agreement of MA (a) and that of TY (b), and inter-rater agreement between MA and TY (c) were shown.

Three scatter plots showing L1 CT-attenuation trial differences versus their averages, with horizontal reference lines at zero.The figure presents three scatter plots (a, b, c) displaying L1 CT-attenuation differences for various trials. - **Panel a:** L1 CT-attenuation trial 2 minus trial 1, points cluster near zero; p-value is 0.46. - **Panel b:** Similar comparison with p-value 0.81, points also close to zero. - **Panel c:** Displays MA versus TY differences; p-value is 0.47, points concentrated around zero. Each plot has dotted lines at the 95% limits of agreement.Figure image at the original source — open the original paper. This file is not included in this text import.

Association between L1 CT-attenuation and bone mineral density of the femoral neck and lumbar spine

The positive correlation of T-scores between the femoral neck and the lumbar spine (Figure 3a), and the positive correlation between CT-measured trabecular attenuation at the L1 vertebral level and T-scores of either the femoral neck (Figure 3b) or lumbar spine (Figure 3c) were shown. Femoral neck and lumbar spine BMDs were significantly correlated (r = 0.598; p < 0.0001). Moreover, L1 CT-attenuation was significantly correlated with the femoral neck (r = 0.527; p < 0.0001) and lumbar spine (r = 0.368; p < 0.0001) BMDs (Table 2).

L1 CT-attenuation was significantly correlated with age, diabetes mellitus, use of calcium-containing phosphorus binder or therapy for osteoporosis, and serum creatinine levels in the univariable regression analysis (Table 2). In addition, L1 CT-attenuation was independently associated with the femoral neck (β = 0.319; p = 0.0003) and lumbar spine (β = 0.265; p = 0.0006) BMDs in the multivariable regression analysis (Table 3).

Figure 3.

Correlation between CT-measured trabecular attenuation at the L1 vertebral level and T-scores of the femoral neck and lumbar spine.

The correlation of T-scores between the femoral neck and the lumbar spine (a), and the correlation between CT-measured trabecular attenuation at the L1 vertebral level and T-scores of either the femoral neck (b) or lumbar spine (c) were shown. The horizontal and vertical reference lines indicate osteoporosis thresholds according to DXA criteria (T-score < −2.5).

Scatterplots showing relationships between femoral neck and L2-L4 T-scores (Panel a, r=0.598), CT attenuation at L1 vs. femoral neck T-scores (Panel b, r=0.527), and CT attenuation at L1 vs. L2-L4 T-scores (Panel c, r=0.368).Panel a features a scatterplot with femoral neck T-scores (y-axis) vs. L2-L4 T-scores (x-axis), showing a positive correlation (r=0.598). Panel b plots CT attenuation at L1 (y-axis) vs. femoral neck T-scores (x-axis), indicating a positive trend (r=0.527). Panel c presents a scatterplot of CT attenuation at L1 vs. L2-L4 T-scores, depicting a weaker positive correlation (r=0.368). Each panel includes reference lines at -2.5 T-scores.Figure image at the original source — open the original paper. This file is not included in this text import.
Table 2.

Associations between CT-measured trabecular attenuation at the L1 vertebral level and baseline variables.

VariablesUnivariable (r)p value
Age −0.579<0.0001
Sex (male)0.0350.71
Body mass index0.1700.065
Smoking0.0800.39
Alcohol0.1030.26
Diabetes mellitus 0.2380.0092
Hemodialysis vintage0.1460.11
Medications  
 Calcium-containing phosphorus binder0.1950.033
 Vitamin D0.0970.29
 Calcium-sensing receptor agonists−0.1480.11
 Therapy for osteoporosis−0.1940.034
Serum albumin0.1480.11
Total cholesterol−0.0640.49
Serum creatinine 0.2360.0097
Calcium0.1380.14
Phosphorus0.0570.54
Intact parathyroid hormone−0.1020.27
25(OH)D (n = 90)−0.1470.17
C-reactive protein−0.0540.56
Bone mineral density at the femoral neck 0.527<0.0001
Femoral neck T-score 0.527<0.0001
Bone mineral density at the lumbar spine 0.368<0.0001
Lumber spine T-score 0.368<0.0001

CT, Computed tomography.

Table 3.

Associations between CT-measured trabecular attenuation at the L1 vertebral level and BMD measured at the femoral neck and lumbar spine.

VariablesMultivariable model including femoral neck BMD (β)p valueVIFMultivariable model including lumbar spine BMD (β)p valueVIF
Age−0.486<0.00011.66−0.596<0.00011.42
Diabetes mellitus0.1520.0341.060.1280.0791.11
Calcium-containing phosphorus binder0.0240.741.130.0210.781.13
Therapy for osteoporosis−0.0220.781.37−0.0940.201.14
Serum creatinine0.0780.351.510.1070.211.49
BMD at the femoral neck 0.3190.00031.57–– 
BMD at the lumbar spine –– 0.2650.00061.18

CT, computed tomography; BMD, bone mineral density; VIF, variation inflation factor.

L1 CT-attenuation cutoffs for diagnosing osteoporosis

The ROC-derived optimal cutoff for L1 CT-attenuation was 109.3 HU (area under the curve [AUC], 0.705; sensitivity, 0.735; specificity, 0.643; p < 0.0001) (Figure 4). An L1 CT-attenuation threshold of 71.3 HU achieved ≥90% specificity, whereas a threshold of 151.1 HU achieved ≥90% sensitivity for diagnosing osteoporosis.

Figure 4.

Receiver operating characteristic (ROC) analysis of CT-measured trabecular attenuation at the L1 vertebral level for osteoporosis diagnosis. Osteoporosis was defined as a low DEXA-measured T-score of < −2.5. T-scores for the femoral neck and lumbar spine were evaluated, and the lower value among these scores was used.

A ROC curve showing sensitivity against 1-specificity, with values from 0 to 1 on both axes.The figure depicts a receiver operating characteristic (ROC) curve on a Cartesian grid. The x-axis, labeled "1 - Specificity," ranges from 0 to 1, while the y-axis, labeled "Sensitivity," also spans from 0 to 1. A black staircase curve illustrates sensitivity rising as 1-specificity increases. It begins at the origin (0,0) and reaches a maximum sensitivity near 1 at (1,1), surpassing a diagonal reference line that indicates baseline performance. Gridlines assist in interpreting the values across both axes.Figure image at the original source — open the original paper. This file is not included in this text import.

Association between L1 CT-attenuation and osteoporosis

In logistic regression analyses with restricted cubic splines, L1 CT-attenuation was significantly associated with osteoporosis both before and after adjusting for covariates (p = 0.0012 and p = 0.0041, respectively). There was no evidence of non-linearity in the association (p for non-linearity = 0.82 in the unadjusted model and p = 0.52 in the adjusted model), indicating that the relationship between L1 CT-attenuation and osteoporosis can be adequately described as linear (Figure 5).

Figure 5.

Association between L1 CT-attenuation and osteoporosis using restricted cubic spline analysis.

The curve shows the adjusted log odds ratio for osteoporosis by L1 CT-attenuation, with 95% confidence intervals shown as gray-shaded areas. The model was adjusted for age, sex, and body mass index. No significant non-linearity was observed (p for non-linearity = 0.52), supporting a linear relationship.

Line graph depicting a decreasing trend in log odds ratio as L1 CT-attenuation increases, with a shaded confidence interval.The graph illustrates the relationship between L1 CT-attenuation (x-axis, 60 to 160) and log odds ratio (y-axis, -1 to 4). A downward trending black line indicates a decrease in log odds ratio with increasing L1 CT-attenuation. Surrounding the line, a shaded gray area represents the confidence interval, showing variability which narrows at higher L1 CT-attenuation values. In the top right corner, the p-value for non-linearity is noted as 0.52.Figure image at the original source — open the original paper. This file is not included in this text import.

Unadjusted and adjusted ORs of L1 CT-attenuation for diagnosing osteoporosis

The unadjusted OR for diagnosing osteoporosis per 10-HU-increase in L1 CT-attenuation was 0.817 (95% CI, 0.722–0.904; p < 0.0001). Additionally, the sex–age–BMI-adjusted OR for diagnosing osteoporosis per 10-HU-increase in L1 CT-attenuation was 0.73 (95% CI, 0.592–0.868; p = 0.0003).

Source: Results Source: Results Source: Results Source: Results Source: Results Source: Results
Authors’ abstract

Abstract

The risk of fractures and osteoporosis is higher in patients on hemodialysis than in the general population. We examined the association between computed tomography (CT)-measured trabecular attenuation at the first lumbar vertebra (L1 CT-attenuation), bone mineral density (BMD), and osteoporosis in patients on hemodialysis. We retrospectively included Japanese patients on hemodialysis who underwent non-enhanced abdominal CT and dual-energy X-ray absorptiometry (DEXA) analyses as part of a medical checkup between April 2019 and March 2021. L1 CT-attenuation (Hounsfield units, HU) and BMD of the femoral neck and lumbar spine were measured.

We analyzed associations between L1 CT-attenuation and BMD and examined its diagnostic accuracy and odds ratio for detecting osteoporosis, defined as a DEXA T-score of < −2.5 at either site. A total of 119 patients (mean age: 67.2 years; men; 63.0%; body mass index [BMI]: 22.4 ± 3.9 kg/m2) were included, of whom 49 had osteoporosis. L1 CT-attenuation was independently linked to BMD at the femoral neck and lumbar spine. The optimal cutoff derived from receiver operating characteristic curve analysis was 109.3 HU.

Thresholds of ≤71.3 HU and ≥151.1 HU provided 90% specificity and 90% sensitivity for distinguishing patients with and without osteoporosis. The age-, sex-, and BMI-adjusted odds ratio of L1 CT-attenuation (per 10 HU) for diagnosing osteoporosis was 0.73. L1 CT-attenuation was independently associated with BMD and may be utilized for osteoporosis screening in Japanese patients on hemodialysis. Opportunistic abdominal CT may aid early detection and intervention for osteoporosis in these patients.

Read the full paper

Introduction

Osteoporosis is a bone disorder characterized by decreased bone strength, which adversely affects bone quantity and quality and increasing fracture risk. The Kidney Disease: Improving Global Outcomes (KDIGO) Controversies Conference introduced chronic kidney disease (CKD)-associated osteoporosis as a new conceptual framework within CKD–mineral and bone disorders [1]. The occurrence of fractures is higher in patients with CKD than in the general population due to both CKD-specific and traditional risk factors [1,2]. Traditional risk factors include age and menopause, whereas CKD-specific risk factors include disturbances in mineral metabolism, uremic toxins, immune (systemic inflammation), endocrine (hyperparathyroidism and vitamin D deficiency), and neurohormonal disturbances, as well as a long dialysis duration [1,2].

Moreover, patients with CKD often have secondary risk factors for osteoporosis, such as hypogonadism, glucocorticoid use, diabetes mellitus, low body mass index (BMI), and malnutrition [1–3]. Because bone fractures are associated with a high risk of cardiovascular events and mortality [4–7], therefore, preventing osteoporosis is crucial in patients undergoing hemodialysis.

In patients with CKD, a history of fragility fractures or T-scores < −2.5 must be considered indicative of osteoporosis, regardless of disturbances in mineral metabolism [8]. Bone mineral density (BMD) is typically measured to assist in diagnosing and monitoring osteoporosis using dual-energy X-ray absorptiometry (DEXA). A Japanese cohort study revealed the association between a decreased BMD and an increased fracture risk in patients undergoing hemodialysis [9]. Thus, guidelines for CKD–mineral and bone disorders recommend BMD assessment in patients undergoing hemodialysis [10].

However, not all patients undergo DEXA. Recently, opportunistic assessment of trabecular attenuation values in vertebrae using routine abdominal computed tomography (CT) has gained attention as an increasingly valuable method for identifying high-risk patients for osteoporosis [11–26]. Among these approaches, average CT-attenuation values (in Hounsfield units, HU) at the first lumbar vertebral level (L1 CT-attenuation) has emerged as a reliable and clinically practical surrogate for BMD. Trabecular attenuation measured at the L1 level is as accurate as, or more accurate than, measurements at other levels for predicting osteoporosis [11].

Additionally, the L1 level is easy to identify and is included in standard chest and abdominal CT scans [11]. Thus, L1-level measurements have been widely used in studies of prior opportunistic osteoporosis screening [11–26]. Pickhardt et al. performed a cross-sectional analysis of patients who underwent abdominal CT and DEXA within 6 months and first proposed practical HU thresholds: < 110 HU strongly indicates osteoporosis, whereas > 160 HU indicates that osteoporosis is unlikely [11].

Thereafter, various cutoffs have been reported in different ethnic and clinical settings [15,22,24–26]. However, to our knowledge, the relationship between L1 CT-attenuation, BMD, and osteoporosis prediction has not been examined in patients on hemodialysis. Thus, the present study aimed to examine the association among L1 CT-attenuation, BMD, and osteoporosis in these patients.

Methods

Participants and inclusion and exclusion criteria

This study retrospectively enrolled adult patients aged ≥18 years who had been receiving maintenance hemodialysis for ≥6 months and underwent plain abdominal CT and DEXA scans of the lumbar spine and femoral neck within the same week from April 2019 and March 2021 at Matsunami General Hospital, Kasamatsu, Gifu. At our institution, CT and DEXA scans are included in the annual checkup. Patients with bilateral femoral neck fractures and bedridden patients were excluded. We also excluded patients with symptomatic lumbar compression fractures at the L1 level or those who had undergone surgery, as L1 CT-attenuation or lumbar spine BMD could not be measured appropriately in these cases.

This study was conducted in accordance with the Declaration of Helsinki and was approved by the institutional review board of Matsunami General Hospital (‘Ethics Committee of Matsunami General Hospital Medical’; approval number: No. 643). The informed consent requirement was waived because the present retrospective study used chart reviews of previously performed CT and DEXA examinations.

Collection of clinical data

We retrieved all patient information from medical charts, including age, sex, BMI, smoking and alcohol consumption (self-reported current alcohol use), underlying kidney disease (nephrosclerosis, chronic glomerulonephritis, diabetic kidney disease, and others), history of diabetes mellitus, duration of hemodialysis, and medications, including a phosphorus binder (especially calcium-containing), oral or parenteral vitamin D, oral or parenteral calcium-sensing receptor agonists, and osteoporosis therapies (bisphosphonate, romosozumab, and selective estrogen receptor modulator). A blood test was performed in the supine position before the initiation of hemodialysis on Mondays or Tuesdays.

Laboratory data and findings of CT and DEXA performed within 1 month were used for data analyses.

Measurement of L1 CT-attenuation values

Non-enhanced abdominal CT was performed using a multidetector CT scanner (LightSpeed Series; GE HealthCare, Chicago, IL, USA). All CT scans were performed at 120 kVp with a 5 mm slice thickness and a 512 × 512 matrix. The in-plane pixel spacing, derived from the DICOM metadata, ranged from approximately 0.51 to 0.97 mm, depending on the field of view. A single axial computed tomography (CT) slice through the center of the L1 vertebral body was selected at the pedicular level.

L1 was defined as the first non-rib-bearing vertebra. HU measurements were retrospectively assessed using a picture archiving and communication system (XTREK View; J-MAC System, Inc., Sapporo, Japan) with a region-of-interest (ROI) tool. For each patient, the ROI was manually placed over the trabecular bone of L1, with the maximum possible elliptical diameter, avoiding the vertebral cortex and the posterior venous plexus, as previously reported (Figure 1) [11,19,26]. The mean CT value (HU) within the ROI was defined as the L1 CT-attenuation.

An example of L1 CT-attenuation measurement is shown in Figure 1. Two examiners, MA and TY, measured L1 CT-attenuation. They could vary the selection of an axial slice at the L1 level and the placement and size of the ROI within the trabecular bone. Both examiners were masked to patients’ clinical information, including DXA results and laboratory data. Each observer was also masked to the other’s measurements.

Figure 1.

An example of measuring L1 CT-attenuation value.

A single axial computed tomography (CT) slice of the first lumbar (L1) vertebral body was selected at the pedicular level. The region of interest (ROI) tool was used. The ROI was set to the maximum possible elliptical diameter without including the vertebral cortex or the basivertebral venous plexus. The average CT value within the ROI was defined as L1 CT-attenuation. In this case, the L1 CT-attenuation was 104.37 HU.

Axial abdominal CT scan with ROI highlighting structures, showing HU values: mean 104.37, min 41, max 169, standard deviation 18.25.This axial CT scan of the abdomen displays internal structures in grayscale, including organs like the liver, spleen, and kidneys. An irregular oval region of interest (ROI) is centered over a vertebral body. The quantitative metrics indicate a mean Hounsfield Unit (HU) of 104.37, a min of 41 HU, and a max of 169 HU, with a standard deviation of 18.25 HU. Anatomical orientation is marked with "R" and "L" for right and left. The varying tissue densities are rendered in different shades of gray, enhancing the visibility of the structures.Figure image at the original source — open the original paper. This file is not included in this text import.

BMD measurement using DEXA

BMDs measurements at the proximal femoral neck and lumbar vertebrae were assessed using standard techniques on a DEXA scanner with Smart BMD software (SONIALVISION G4; Shimadzu Corporation, Kyoto, Japan). BMD is expressed in g/cm2. Osteoporosis was defined as a low DEXA T-score of < −2.5 at either the femoral neck or lumbar spine, according to the WHO criteria [27,28].

Statistical analyses

Non-normally distributed variables are described as medians and interquartile ranges and normally distributed variables by means and standard deviations. Intra- and inter-rater reproducibility of L1 CT-attenuation values were evaluated using the intraclass correlation coefficient (ICC) and 95% confidence interval (CI). ICC >0.9 was considered excellent for reproducibility and clinical acceptability. The agreement was further evaluated using a Bland–Altman analysis. Continuous variables were compared using the t-test or the Wilcoxon signed-rank test and categorical variables using the chi-squared test between patients with and without osteoporosis.

The correlations among L1 CT-attenuation and T-scores of the femoral neck and lumbar spine were shown with scatter plots. Correlation between L1 CT-attenuation and femoral neck or lumbar spine BMD was assessed with Pearson’s correlation coefficient. Before applying linear models, the linearity between L1 CT-attenuation and BMD was visually assessed using scatter plots. Univariable regression analysis was performed to evaluate associations between baseline variables and L1 CT-attenuation. Thereafter, multivariable regression analysis was performed with a model that included all significant variables from the univariable regression analysis.

BMDs at the femoral neck and at the lumbar spine were analyzed in separate models to avoid multicollinearity arising from their strong correlation. We assessed multicollinearity using variance inflation factors (VIFs). The optimal cutoff value of L1 CT-attenuation for diagnosing osteoporosis was determined using receiver operating characteristic (ROC) curve analysis with the Youden index. In addition, we determined the L1 CT-attenuation thresholds that demonstrated high sensitivity (≥ 90%) and specificity (≥ 90%) for diagnosing osteoporosis. To account for potential non-linear relationships and to further assess the robustness of the association, logistic regression analyses were performed with osteoporosis (defined as a T-score < −2.5) as the outcome.

Non-linearity was evaluated using restricted cubic splines with three knots. Multivariable models were adjusted for clinically relevant covariates, including age, sex, and BMI.

Furthermore, unadjusted and sex–age–BMI-adjusted odds ratios (ORs) and 95% CIs for L1 CT-attenuation values were evaluated to assess their association with osteoporosis. Most variables were available for all participants; however, 25(OH)D levels were measured in a subset of patients (n = 90) because of the retrospective design of the present study. Analyses involving this variable were conducted using the available data. If minor missing data were present, a complete case analysis was performed. We used SPSS Statistics for Windows, version 31 (IBM Corp., Armonk, NY, USA) for statistical analyses and JMP®, version 19 (JMP Statistical Discovery LLC, Cary, NC, USA).

A p-value < 0.05 was considered significant.

Results

Background characteristics of study participants

We screened 128 Japanese patients receiving maintenance hemodialysis and excluded two patients with bilateral fractures of the femoral neck (bedridden status) and 7 patients with symptomatic vertebral fractures. We included 119 patients (mean age: 67.2 years; men: 63%; BMI: 22.4 kg/m2), of whom 49 patients were diagnosed with osteoporosis. Baseline characteristics are summarized in Table 1.

Table 1.

Background characteristics of the study participants.

VariablesAll patients (N = 119)Non-osteoporosis (n = 70)Osteoporosis (n = 49)p value
Age (year)67.2 ± 12.764.7 ± 13.070.9 ± 11.30.0076
Male (%)63.082.934.7<0.0001
Body mass index (kg/m2)22.4 ± 3.923.8 ± 3.820.5 ± 3.2<0.0001
Smoking (%)22.722.922.40.96
Alcohol consumption (%)28.632.922.40.21
Underlying kidney disease   0.74
Diabetic nephropathy41.244.336.7 
Chronic glomerulonephritis26.125.726.5 
Nephrosclerosis23.522.924.5 
Others9.27.112.2 
Diabetes mellitus (%)43.648.636.70.20
Hemodialysis duration (years)3.3 (1.7–6.4)3.5 (2.0–6.2)3.3 (1.3–6.8)0.57
Medications (%)    
 Calcium-containing phosphorous binder (%)50.460.036.70.012
 Vitamin D (%)58.857.161.30.90
  Oral (%)7.67.18.2 
  Parenteral (%)51.250.053.1 
 Calcium-sensing receptor agonists (%)13.410.018.40.24
  Oral (%)7.67.18.2 
  Parenteral (%)5.92.910.2 
 Therapy for osteoporosis (%)12.6030.6<0.0001
  Bisphosphonate (%)4.2010.2 
  Romosozumab (%)7.6018.4 
  Selective estrogen receptor modulator (%)0.802.0 
Serum albumin (g/dL)3.4 ± 0.33.4 ± 0.33.3 ± 0.30.14
Total cholesterol (mg/dL)145 ± 38140 ± 42153 ± 320.063
Serum creatinine (mg/dL)9.4 ± 3.210.0 ± 3.58.7 ± 2.40.029
Calcium (mg/dL)8.6 ± 0.68.6 ± 0.68.5 ± 0.70.50
Phosphorus (mg/dL)4.6 ± 1.14.5 ± 1.24.7 ± 1.10.46
Intact parathyroid hormone (pg/mL)135 (63–207)134 (63–191)143 (67–243)0.23
25(OH)D (ng/mL) (n = 90)11.9 ± 5.6 (n = 90)12.2 ± 5.3 (n = 56)11.4 ± 6.1 (n = 34)0.52
C-reactive protein (mg/dL)0.10 (0.03–0.28)0.12 (0.03–0.36)0.08 (0.04–0.19)0.35
Bone mineral density at the femoral neck (g/cm2)0.70 ± 0.110.78 ± 0.080.60 ± 0.06 
Femoral neck T-score−2.11 ± 1.03−1.46 ± 0.73−3.04 ± 0.58 
Bone mineral density at the lumbar spine (g/cm2)1.02 ± 0.181.11 ± 0.130.88 ± 0.15 
Lumber spine T-score−1.19 ± 1.24−0.54 ± 0.93−2.13 ± 1.00 
CT-measured trabecular attenuation at the L1 vertebral level (Hounsfield units)110.3 ± 41.0122.3 ± 40.293.1 ± 35.9<0.0001

CT, computed tomography.

Reproducibility of L1 CT-attenuation measurements

Intra- and inter-rater reproducibility and agreement of L1 CT-attenuation measurements were assessed in 30 randomly selected patients using ICCs and Bland–Altman analysis. Intra-rater ICCs were 0.999 (95% CI: 0.998–0.999) for MA and 0.999 (95% CI: 0.998–1) for TY, and the inter-rater (MA and TY) ICC was 0.999 (95% CI: 0.997–0.999). Bland–Altman analysis demonstrated good intra-rater and inter-rater agreement (Figure 2).

Figure 2.

Bland–Altman analysis to assess agreement of L1 computed tomography (CT)-attenuation values.

Two investigators (MA and TY) measured L1 CT-attenuation values and described the differences and 95% confidence intervals for the plots. Intra-rater agreement of MA (a) and that of TY (b), and inter-rater agreement between MA and TY (c) were shown.

Three scatter plots showing L1 CT-attenuation trial differences versus their averages, with horizontal reference lines at zero.The figure presents three scatter plots (a, b, c) displaying L1 CT-attenuation differences for various trials. - **Panel a:** L1 CT-attenuation trial 2 minus trial 1, points cluster near zero; p-value is 0.46. - **Panel b:** Similar comparison with p-value 0.81, points also close to zero. - **Panel c:** Displays MA versus TY differences; p-value is 0.47, points concentrated around zero. Each plot has dotted lines at the 95% limits of agreement.Figure image at the original source — open the original paper. This file is not included in this text import.

Association between L1 CT-attenuation and bone mineral density of the femoral neck and lumbar spine

The positive correlation of T-scores between the femoral neck and the lumbar spine (Figure 3a), and the positive correlation between CT-measured trabecular attenuation at the L1 vertebral level and T-scores of either the femoral neck (Figure 3b) or lumbar spine (Figure 3c) were shown. Femoral neck and lumbar spine BMDs were significantly correlated (r = 0.598; p < 0.0001). Moreover, L1 CT-attenuation was significantly correlated with the femoral neck (r = 0.527; p < 0.0001) and lumbar spine (r = 0.368; p < 0.0001) BMDs (Table 2).

L1 CT-attenuation was significantly correlated with age, diabetes mellitus, use of calcium-containing phosphorus binder or therapy for osteoporosis, and serum creatinine levels in the univariable regression analysis (Table 2). In addition, L1 CT-attenuation was independently associated with the femoral neck (β = 0.319; p = 0.0003) and lumbar spine (β = 0.265; p = 0.0006) BMDs in the multivariable regression analysis (Table 3).

Figure 3.

Correlation between CT-measured trabecular attenuation at the L1 vertebral level and T-scores of the femoral neck and lumbar spine.

The correlation of T-scores between the femoral neck and the lumbar spine (a), and the correlation between CT-measured trabecular attenuation at the L1 vertebral level and T-scores of either the femoral neck (b) or lumbar spine (c) were shown. The horizontal and vertical reference lines indicate osteoporosis thresholds according to DXA criteria (T-score < −2.5).

Scatterplots showing relationships between femoral neck and L2-L4 T-scores (Panel a, r=0.598), CT attenuation at L1 vs. femoral neck T-scores (Panel b, r=0.527), and CT attenuation at L1 vs. L2-L4 T-scores (Panel c, r=0.368).Panel a features a scatterplot with femoral neck T-scores (y-axis) vs. L2-L4 T-scores (x-axis), showing a positive correlation (r=0.598). Panel b plots CT attenuation at L1 (y-axis) vs. femoral neck T-scores (x-axis), indicating a positive trend (r=0.527). Panel c presents a scatterplot of CT attenuation at L1 vs. L2-L4 T-scores, depicting a weaker positive correlation (r=0.368). Each panel includes reference lines at -2.5 T-scores.Figure image at the original source — open the original paper. This file is not included in this text import.
Table 2.

Associations between CT-measured trabecular attenuation at the L1 vertebral level and baseline variables.

VariablesUnivariable (r)p value
Age −0.579<0.0001
Sex (male)0.0350.71
Body mass index0.1700.065
Smoking0.0800.39
Alcohol0.1030.26
Diabetes mellitus 0.2380.0092
Hemodialysis vintage0.1460.11
Medications  
 Calcium-containing phosphorus binder0.1950.033
 Vitamin D0.0970.29
 Calcium-sensing receptor agonists−0.1480.11
 Therapy for osteoporosis−0.1940.034
Serum albumin0.1480.11
Total cholesterol−0.0640.49
Serum creatinine 0.2360.0097
Calcium0.1380.14
Phosphorus0.0570.54
Intact parathyroid hormone−0.1020.27
25(OH)D (n = 90)−0.1470.17
C-reactive protein−0.0540.56
Bone mineral density at the femoral neck 0.527<0.0001
Femoral neck T-score 0.527<0.0001
Bone mineral density at the lumbar spine 0.368<0.0001
Lumber spine T-score 0.368<0.0001

CT, Computed tomography.

Table 3.

Associations between CT-measured trabecular attenuation at the L1 vertebral level and BMD measured at the femoral neck and lumbar spine.

VariablesMultivariable model including femoral neck BMD (β)p valueVIFMultivariable model including lumbar spine BMD (β)p valueVIF
Age−0.486<0.00011.66−0.596<0.00011.42
Diabetes mellitus0.1520.0341.060.1280.0791.11
Calcium-containing phosphorus binder0.0240.741.130.0210.781.13
Therapy for osteoporosis−0.0220.781.37−0.0940.201.14
Serum creatinine0.0780.351.510.1070.211.49
BMD at the femoral neck 0.3190.00031.57–– 
BMD at the lumbar spine –– 0.2650.00061.18

CT, computed tomography; BMD, bone mineral density; VIF, variation inflation factor.

L1 CT-attenuation cutoffs for diagnosing osteoporosis

The ROC-derived optimal cutoff for L1 CT-attenuation was 109.3 HU (area under the curve [AUC], 0.705; sensitivity, 0.735; specificity, 0.643; p < 0.0001) (Figure 4). An L1 CT-attenuation threshold of 71.3 HU achieved ≥90% specificity, whereas a threshold of 151.1 HU achieved ≥90% sensitivity for diagnosing osteoporosis.

Figure 4.

Receiver operating characteristic (ROC) analysis of CT-measured trabecular attenuation at the L1 vertebral level for osteoporosis diagnosis. Osteoporosis was defined as a low DEXA-measured T-score of < −2.5. T-scores for the femoral neck and lumbar spine were evaluated, and the lower value among these scores was used.

A ROC curve showing sensitivity against 1-specificity, with values from 0 to 1 on both axes.The figure depicts a receiver operating characteristic (ROC) curve on a Cartesian grid. The x-axis, labeled "1 - Specificity," ranges from 0 to 1, while the y-axis, labeled "Sensitivity," also spans from 0 to 1. A black staircase curve illustrates sensitivity rising as 1-specificity increases. It begins at the origin (0,0) and reaches a maximum sensitivity near 1 at (1,1), surpassing a diagonal reference line that indicates baseline performance. Gridlines assist in interpreting the values across both axes.Figure image at the original source — open the original paper. This file is not included in this text import.

Association between L1 CT-attenuation and osteoporosis

In logistic regression analyses with restricted cubic splines, L1 CT-attenuation was significantly associated with osteoporosis both before and after adjusting for covariates (p = 0.0012 and p = 0.0041, respectively). There was no evidence of non-linearity in the association (p for non-linearity = 0.82 in the unadjusted model and p = 0.52 in the adjusted model), indicating that the relationship between L1 CT-attenuation and osteoporosis can be adequately described as linear (Figure 5).

Figure 5.

Association between L1 CT-attenuation and osteoporosis using restricted cubic spline analysis.

The curve shows the adjusted log odds ratio for osteoporosis by L1 CT-attenuation, with 95% confidence intervals shown as gray-shaded areas. The model was adjusted for age, sex, and body mass index. No significant non-linearity was observed (p for non-linearity = 0.52), supporting a linear relationship.

Line graph depicting a decreasing trend in log odds ratio as L1 CT-attenuation increases, with a shaded confidence interval.The graph illustrates the relationship between L1 CT-attenuation (x-axis, 60 to 160) and log odds ratio (y-axis, -1 to 4). A downward trending black line indicates a decrease in log odds ratio with increasing L1 CT-attenuation. Surrounding the line, a shaded gray area represents the confidence interval, showing variability which narrows at higher L1 CT-attenuation values. In the top right corner, the p-value for non-linearity is noted as 0.52.Figure image at the original source — open the original paper. This file is not included in this text import.

Unadjusted and adjusted ORs of L1 CT-attenuation for diagnosing osteoporosis

The unadjusted OR for diagnosing osteoporosis per 10-HU-increase in L1 CT-attenuation was 0.817 (95% CI, 0.722–0.904; p < 0.0001). Additionally, the sex–age–BMI-adjusted OR for diagnosing osteoporosis per 10-HU-increase in L1 CT-attenuation was 0.73 (95% CI, 0.592–0.868; p = 0.0003).

Discussion

To the best of our knowledge, this is the first study to examine the association among L1 CT-attenuation, BMD, and osteoporosis in Japanese patients on hemodialysis. L1 CT-attenuation was independently associated with the femoral neck and lumbar vertebral BMD. The optimal L1 CT-attenuation cutoff for diagnosing osteoporosis was 109.3 HU, which demonstrated moderate diagnostic accuracy (AUC: 0.705). Moreover, thresholds of ≥151.1 HU exhibited over 90% sensitivity, whereas a threshold of 71.3 HU or lower exhibited over 90% specificity for distinguishing between patients with and without osteoporosis.

After adjusting for age, sex, and BMI, a low L1 CT-attenuation value was independently associated with osteoporosis. Therefore, CT screening may facilitate the early detection and intervention for osteoporosis in this population.

In this study, we measured L1 CT-attenuation using an abdominal CT image for kidney cancer screening. Two masked investigators evaluated L1 CT-attenuation in 30 randomly selected patients, demonstrating excellent reproducibility and agreement of L1 CT-attenuation measurements, as previously reported in healthy individuals [29]; this finding indicates that L1 CT-attenuation may be a clinically acceptable biomarker in patients on hemodialysis.

We examined the association between L1 CT-attenuation and BMD of the femoral neck and lumbar spine. Previous studies have reported stronger correlations of L1 CT-attenuation with lumbar spine BMD than with femoral neck BMD (r = 0.552 vs. 0.349 and 0.726 vs. 0.503, respectively) [18,30]. Conversely, in this study, the correlation between L1 CT-attenuation and femoral neck BMD (r = 0.527) was stronger than that between L1 CT-attenuation and lumbar spine BMD (r = 0.368).

This may reflect that DEXA findings incorporate posterior spinal elements, which can lead to inaccuracies in cases of previous lumbar surgery, scoliosis, or severe spinal degeneration [31,32]. In addition, the lumbar spine BMD may be overestimated in patients with CKD due to vascular calcification [33,34]. Although we excluded patients with a history of L1 vertebral fracture or lumbar surgery, the BMD measurement of the lumbar vertebra might have been less accurate than that of the femoral neck owing to lumbar degeneration or vascular calcification.

Moreover, the number of patients with osteoporosis with a T-score of femoral neck < − 2.5 was higher than the number of patients with a T-score of lumbar spine < − 2.5 (N = 46 vs. N = 20, respectively; details not shown). Because L1 CT-attenuation was derived from trabecular bone regions, the association between vertebral cortical bone and BMD could not be assessed in the present study. In CKD-mineral and bone disorders, trabecular bone is closely linked to changes in bone turnover, whereas cortical bone abnormality contributes to bone fragility and fracture risk.

Notably, cortical bone involvement is prominent, with increased cortical porosity representing a major skeletal abnormality in secondary hyperparathyroidism [35]. Thus, this pathophysiology might partly explain why L1 CT-attenuation correlated more strongly with femoral neck BMD than with lumbar spine BMD. However, whether the lumbar spine’s cortical bone is similarly affected by secondary hyperparathyroidism as the femoral neck’s cortical bone remains unknown.

Importantly, L1 CT-attenuation was independently associated with DEXA-measured BMDs of the femoral neck and lumbar vertebrae after adjusting for age, diabetes mellitus, use of calcium-containing phosphorus binders or osteoporosis therapy, and creatinine levels. These findings indicate that L1 CT-attenuation is a useful marker of BMD in patients undergoing hemodialysis. However, we have to acknowledge that some variables (i.e., age, BMD, and osteoporosis therapy) may not be fully independent in the multivariable regression models. We assessed multicollinearity using VIFs and observed no significant collinearity among the included variables.

Age is a well-known determinant of both BMD and L1 CT-attenuation values; therefore, age was included in the model to adjust for its confounding effect on the association between L1 CT-attenuation and BMD. Regarding osteoporosis therapy, we acknowledge that it is not independent of BMD, as it is typically initiated in patients with decreased BMD. For this reason, osteoporosis therapy was included as a covariate to account for its potential modifying effect rather than assuming independence. To assess this, we added a sensitivity analysis assessing the associations between L1 CT-attenuation and BMDs at the femoral neck and lumbar spine in patients who did not receive osteoporosis therapy (N = 104).

Results were similar to those in the primary analyses: L1 CT-attenuation was independently associated with BMD at the femoral neck (β = 0.287, p = 0.0006) and with BMD at the lumbar spine (β = 0.254, p = 0.0012) (details not shown in the manuscript). Moreover, L1 CT-attenuation was independently associated with diabetes mellitus in the model including femoral neck BMD, but not in the model including lumbar spine BMD. The lumbar spine is predominantly trabecular, whereas the femoral neck contains a relatively higher proportion of cortical bone in addition to trabecular bone.

Diabetes mellitus affects bone vulnerability through site-specific mechanisms with an increased cortical porosity in cortical bone rather than deterioration of trabecular microarchitecture in trabecular bone [36]. These differences in bone composition may have contributed to the observed discrepancy between models. In addition, given the relatively small sample size, the lack of significance in the model including lumbar spine BMD may be attributable to limited statistical power.

Thresholds for L1 CT-attenuation in diagnosing osteoporosis, including diagnostic performance and clinical interpretation, have been reported previously. Pickhardt et al. first reported an ROC-derived optimal threshold for L1 CT-attenuation of 135 HU with good diagnostic accuracy (AUC: 0.83) in a large USA-based cohort study [11]. Subsequently, many studies have shown that the optimal thresholds for osteoporosis diagnosis range from 95 to 180 HU, with moderate to good diagnostic accuracy (AUC 0.64–0.86) [12–23]. However, no such reports were found for the Japanese population; therefore, we could not compare our results with those of the general Japanese population.

Nevertheless, within the Asian population, the optimal L1 CT-attenuation thresholds for osteoporosis diagnosis ranged from 95 to 136 HU, with AUCs of 0.74–0.86 [16–18,21,23]. In the present study, the optimal L1 CT-attenuation cutoff value for osteoporosis diagnosis was 109.3 HU (AUC: 0.705). This value was remarkably consistent with the thresholds reported in previous studies on Asian populations and had an acceptable discriminatory ability for osteoporosis diagnosis. Moreover, Pickhardt et al. proposed thresholds of < 110 HU for > 90% specificity and > 160 HU for > 90% sensitivity to discriminate between patients with and without osteoporosis [11].

Subsequently, several studies have reported different thresholds for osteoporosis diagnosis: 73–104 HU for > 90% specificity and 139–180 HU for > 90% sensitivity [15,22,24–26]. In this study, we identified clinically meaningful thresholds of ≤ 71.3 HU for > 90% specificity and ≥ 151.1 HU for > 90% sensitivity, which may be useful for screening and risk stratification of osteoporosis in practice.

Differences in cutoff values and diagnostic accuracies have been reported for various cohorts. These differences may reflect factors such as osteoporosis diagnosis, imaging modalities (including CT and DEXA), interval between CT and BMD measurements, and population characteristics (including race, sex, age, and background diseases). In this study, osteoporosis was diagnosed according to the WHO diagnostic criteria: a T-score of less than −2.5 at the femoral neck or lumbar spine was considered osteoporosis [27,28]. We performed CT and DEXA analyses, which are widely used techniques in Japan.

Although in previous studies, the interval between CT and DEXA measurements varied (from 2 weeks to 2 years) [37], we performed CT and DEXA within the same week because they were part of a routine medical checkup for cancer screening at our hospital. Non-enhanced CT was performed at 120 kV to screen for renal cancer. CT attenuation is influenced by the kilovoltage, and these existing diagnostic thresholds are typically based on CT scans performed at 120 kV. A recent review reported that CT has higher diagnostic value for osteoporosis in Asian populations, particularly when non-enhanced CT is performed alone, participants are aged ≥ 65 years, and the proportion of women among the participants is high [38].

In this study, we enrolled Japanese patients undergoing hemodialysis who underwent non-enhanced CT; however, the patients were relatively young, and men outnumbered women. Patients undergoing hemodialysis represent a unique population characterized by profound disturbances in mineral metabolism, chronic inflammation, endocrine abnormalities, and accelerated bone loss [1,2]. Despite differences between our results and those of previous studies, the strength of the association between L1 CT-attenuation and BMD observed in our study was comparable to that reported in general population cohorts.

Additionally, the L1 CT-attenuation cutoffs for diagnostic performance and clinical interpretation in our study were comparable to those for the general population cohorts. Our findings may validate L1 CT-attenuation as a robust surrogate marker for BMD and a screening tool for osteoporosis in patients on hemodialysis. Furthermore, the excellent intra- and inter-rater reproducibility and agreement observed in this study support the feasibility of incorporating this measurement into routine clinical practice, potentially through automated, software-based analysis with artificial intelligence in the future [39,40].

In the present study, L1 CT-attenuation was significantly associated with osteoporosis. Importantly, analyses using restricted cubic splines showed no evidence of non-linearity, indicating that this association can be adequately described by a linear model. These findings support the validity of linear regression analyses and suggest that L1 CT-attenuation provides a consistent estimate of bone fragility risk across its observed range.

The present study has some limitations. First, it was a retrospective single-center study with only a small number of Japanese participants, which may limit the generalizability of the findings. In addition, our study population consisted of patients who underwent routine annual checkups, which may represent a relatively healthier subset of the hemodialysis population. This could introduce selection bias and also limit the generalizability of our findings to patients who do not undergo regular checkups. Second, because of the cross-sectional design, causal relationships cannot be established, and the possibility of reverse causation cannot be ruled out.

Third, the lack of internal or external validation, such as split-sample validation or an independent cohort, limits the external validity of our findings. Fourth, we cross-sectionally assessed L1 CT-attenuation and BMDs of femoral neck and lumbar spine at baseline; therefore, future fracture incidence and longitudinal changes in CT attenuation were not evaluated. Fifth, although L1 CT-attenuation provides valuable information on bone density, it cannot replace the comprehensive assessment of bone turnover or histological evaluation, which may be particularly relevant in CKD-related bone diseases.

Future prospective multicenter studies with larger, ethnically diverse cohorts are needed to validate these thresholds across different CT platforms; moreover, in these studies, the ability of L1 CT-attenuation to predict incident fractures can be examined in patients undergoing hemodialysis. Furthermore, automated CT-based bone assessment should be integrated into radiological workflows, which may further enhance the early detection of osteoporosis and improve patient outcomes.

In conclusion, L1 CT-attenuation was independently associated with BMD of the femoral neck and lumbar spine and may be a useful screening tool for osteoporosis in Japanese patients undergoing hemodialysis. Opportunistic evaluation of L1 CT-attenuation using abdominal CT scans is a valuable and cost-effective approach for identifying patients at a high risk of osteoporosis, thereby facilitating early intervention, and potentially reducing fracture-related morbidity in this vulnerable population.

Consent to participate

The requirement for informed consent from the patients was waived because the present study was conducted retrospectively using chart reviews of CT and DEXA scans that had been performed previously.

Ethics statement

This study protocol was reviewed and approved by the Ethics Committee of Matsunami General Hospital Medical (approval number: No. 643).

Disclosure statement

The authors have no conflicts of interest to declare.

Data availability statement

The data that support the findings of this study are not publicly available due to privacy reasons but are available from the corresponding author upon reasonable request.

References

1 Ketteler M , Evenepoel P , Holden RM , et al. Chronic kidney disease-mineral and bone disorder: conclusions from a kidney disease: improving global outcomes (KDIGO) Controversies Conference . Kidney Int . 2025 ;107 (3 ):405 –423 . doi: 10.1016/j.kint.2024.11.013 . 39864017
2 Henry N , Hildebrand S , Cunningham J. Management of osteoporosis in chronic kidney disease . Clin Kidney J . 2025 ;18 (10 ):sfaf228 . doi: 10.1093/ckj/sfaf228 . 41104260 PMC12525161
3 Ebeling PR , Nguyen HH , Aleksova J , et al. Secondary osteoporosis . Endocr Rev . 2022 ;43 (2 ):240 –313 . doi: 10.1210/endrev/bnab028 . 34476488
4 Tentori F , McCullough K , Kilpatrick RD , et al. High rates of death and hospitalization follow bone fracture among hemodialysis patients . Kidney Int . 2014 ;85 (1 ):166 –173 . doi: 10.1038/ki.2013.279 . 23903367 PMC3910091
5 Wakasugi M , Kazama JJ , Wada A , et al. Long-term excess mortality after hip fracture in hemodialysis patients: a nationwide cohort study in Japan . J Bone Miner Metab . 2020 ;38 (5 ):718 –729 . doi: 10.1007/s00774-020-01110-4 . 32399676
6 Yu T-M , Lin C-L , Shu K-H , et al. Increased risk of cardiovascular events in end-stage renal disease patients with osteoporosis: a nationwide population-based cohort study . Osteoporos Int . 2015 ;26 (2 ):785 –793 . doi: 10.1007/s00198-014-2982-0 . 25491767
7 Kwon YE , Choi HY , Oh HJ , et al. Vertebral fracture is associated with myocardial infarction in incident hemodialysis patients: a Korean nationwide population-based study . Osteoporos Int . 2020 ;31 (10 ):1965 –1973 . doi: 10.1007/s00198-020-05423-y . 32394062
8 Evenepoel P , Cunningham J , Ferrari S , et al. European Consensus Statement on the diagnosis and management of osteoporosis in chronic kidney disease stages G4-G5D . Nephrol Dial Transplant . 2021 ;36 (1 ):42 –59 . doi: 10.1093/ndt/gfaa192 . 33098421
9 Iimori S , Mori Y , Akita W , et al. Diagnostic usefulness of bone mineral density and biochemical markers of bone turnover in predicting fracture in CKD stage 5D patients–a single-center cohort study . Nephrol Dial Transplant . 2012 ;27 (1 ):345 –351 . doi: 10.1093/ndt/gfr317 . 21652550
10 KDIGO . Clinical practice guideline update for the diagnosis, evaluation, prevention, and treatment of chronic kidney disease-mineral and bone disorder (CKD-MBD); 2017. Kidney Disease: improving Global Outcomes (KDIGO) CKD-MBD Update Work Group . Kidney Int Suppl . 2011 ;7 (1 ):1 –59 . 10.1016/j.kisu.2017.04.001 PMC6340919 30675420
11 Pickhardt PJ , Pooler BD , Lauder T , et al. Opportunistic screening for osteoporosis using abdominal computed tomography scans obtained for other indications . Ann Intern Med . 2013 ;158 (8 ):588 –595 . doi: 10.7326/0003-4819-158-8-201304160-00003 . 23588747 PMC3736840
12 Buckens CF , Dijkhuis G , de Keizer B , et al. Opportunistic screening for osteoporosis on routine computed tomography? An external validation study . Eur Radiol . 2015 ;25 (7 ):2074 –2079 . doi: 10.1007/s00330-014-3584-0 . 25591750
13 Lee SY , Kwon S-S , Kim HS , et al. Reliability and validity of lower extremity computed tomography as a screening tool for osteoporosis . Osteoporos Int . 2015 ;26 (4 ):1387 –1394 . doi: 10.1007/s00198-014-3013-x . 25592134
14 Burke CJ , Didolkar MM , Barnhart HX , et al. The use of routine non density calibrated clinical computed tomography data as a potentially useful screening tool for identifying patients with osteoporosis . Clin Cases Miner Bone Metab . 2016 ;13 (2 ):135 –140 . doi: 10.11138/ccmbm/2016.13.2.135 . 27920811 PMC5119712
15 Alacreu E , Moratal D , Arana E. Opportunistic screening for osteoporosis by routine CT in Southern Europe . Osteoporos Int . 2017 ;28 (3 ):983 –990 . doi: 10.1007/s00198-016-3804-3 . 28108802
16 Li Y-L , Wong K-H , Law MW-M , et al. Opportunistic screening for osteoporosis in abdominal computed tomography for Chinese population . Arch Osteoporos . 2018 ;13 (1 ):76 . doi: 10.1007/s11657-018-0492-y . 29987388
17 Zou D , Li W , Deng C , et al. The use of CT Hounsfield unit values to identify the undiagnosed spinal osteoporosis in patients with lumbar degenerative diseases . Eur Spine J . 2019 ;28 (8 ):1758 –1766 . doi: 10.1007/s00586-018-5776-9 . 30306332
18 Kim KJ , Kim DH , Lee JI , et al. Hounsfield units on lumbar computed tomography for predicting regional bone mineral density . Open Med (Wars) . 2019 ;14 (1 ):545 –551 . doi: 10.1515/med-2019-0061 . 31410366 PMC6689205
19 Cohen A , Foldes AJ , Hiller N , et al. Opportunistic screening for osteoporosis and osteopenia by routine computed tomography: a heterogeneous, multiethnic, Middle Eastern population validation study . Eur J Radiol . 2021 ;136 :109568 . doi: 10.1016/j.ejrad.2021.109568 . 33545629
20 Abbouchie H , Raju N , Lamanna A , et al. Screening for osteoporosis using L1 vertebral density on abdominal CT in an Australian population . Clin Radiol . 2022 ;77 (7 ):e540–8 –e548 . doi: 10.1016/j.crad.2022.04.002 . 35550303
21 Viswanathan VK , Shetty AP , Rai N , et al. What is the role of CT-based Hounsfield unit assessment in the evaluation of bone mineral density in patients undergoing 1- or 2-level lumbar spinal fusion for degenerative spinal pathologies? A prospective study . Spine J . 2023 ;23 (10 ):1427 –1434 . doi: 10.1016/j.spinee.2023.05.015 . 37271374
22 Vadera S , Osborne T , Shah V , et al. Opportunistic screening for osteoporosis by abdominal CT in a British population . Insights Imaging . 2023 ;14 (1 ):57 . doi: 10.1186/s13244-023-01400-1 . 37005941 PMC10067782
23 Wu L , Huang S , Xu L , et al. Comparison of thoracic vertebrae and L1 CT attenuation in predicting osteoporosis using opportunistic chest CT . Ther Adv Musculoskelet Dis . 2025 ;17 :1759720X251374134 . doi: 10.1177/1759720X251374134 . PMC12432313 40951813
24 Pickhardt PJ , Lauder T , Pooler BD , et al. Effect of IV contrast on lumbar trabecular attenuation at routine abdominal CT: correlation with DXA and implications for opportunistic osteoporosis screening . Osteoporos Int . 2016 ;27 (1 ):147 –152 . doi: 10.1007/s00198-015-3224-9 . 26153046
25 Chaisen M , Sritara C , Chitrapazt N , et al. Opportunistic screening for osteoporosis by CT as compared with DXA . Diagnostics (Basel) . 2024 ;14 (24 ):2846 . doi: 10.3390/diagnostics14242846 . 39767207 PMC11675021
26 Langer FW , Torri GB , Schaffazick F , et al. Opportunistic screening for low bone mineral density in routine computed tomography scans: a Brazilian validation study . J Clin Densitom . 2025 ;28 (1 ):101539 . doi: 10.1016/j.jocd.2024.101539 . 39549611
27 Kanis JA , Melton LJ , 3rd, Christiansen C , et al. The diagnosis of osteoporosis . J Bone Miner Res . 1994 ;9 (8 ):1137 –1141 . 7976495 10.1002/jbmr.5650090802
28 Cosman F , de Beur SJ , LeBoff MS , et al. Clinician’s guide to prevention and treatment of osteoporosis . Osteoporos Int . 2014 ;25 (10 ):2359 –2381 . doi: 10.1007/s00198-014-2794-2 . 25182228 PMC4176573
29 Gerety EL , Hopper MA , Bearcroft PW. The reliability of measuring the density of the L1 vertebral body on CT imaging as a predictor of bone mineral density . Clin Radiol . 2017 ;72 (2 ):177.e9 –177.e15 . doi: 10.1016/j.crad.2016.09.022 . 28340962
30 Kim YW , Kim JH , Yoon SH , et al. Vertebral bone attenuation on low-dose chest CT: quantitative volumetric analysis for bone fragility assessment . Osteoporos Int . 2017 ;28 (1 ):329 –338 . doi: 10.1007/s00198-016-3724-2 . 27480628
31 Bakhsheshian J , Dahdaleh NS , Fakurnejad S , et al. Evidence-based management of traumatic thoracolumbar burst fractures: a systematic review of nonoperative management . Neurosurg Focus . 2014 ;37 (1 ):E1 . doi: 10.3171/2014.4.FOCUS14159 . 24981897
32 Zou D , Jiang S , Zhou S , et al. Prevalence of osteoporosis in patients undergoing lumbar fusion for lumbar degenerative diseases: a combination of DXA and Hounsfield units . Spine (Phila Pa 1976) . 2020 ;45 (7 ):E406 –E410 . doi: 10.1097/BRS.0000000000003284 . 31725127
33 Campagnaro LS , Carvalho AB , Pina PM , et al. Bone mass measurement by DXA should be interpreted with caution in the CKD population with vascular calcification . Bone Rep . 2022 ;16 :101169 . doi: 10.1016/j.bonr.2022.101169 . 35146076 PMC8819399
34 Kim K , Song SH , Kim IJ , et al. Is dual-energy absorptiometry accurate in the assessment of bone status of patients with chronic kidney disease? Osteoporos Int . 2021 ;32 (9 ):1859 –1868 . doi: 10.1007/s00198-020-05670-z . 33598794
35 Nickolas TL , Stein EM , Dworakowski E , et al. Rapid cortical bone loss in patients with chronic kidney disease . J Bone Miner Res . 2013 ;28 (8 ):1811 –1820 . doi: 10.1002/jbmr.1916 . 23456850 PMC3720694
36 Samelson EJ , Demissie S , Cupples LA , et al. Diabetes and deficits in cortical bone density, microarchitecture, and bone size: Framingham HR-pQCT study . J Bone Miner Res . 2018 ;33 (1 ):54 –62 . doi: 10.1002/jbmr.3240 . 28929525 PMC5771832
37 Ahmad A , Crawford CH , Glassman SD , et al. Correlation between bone density measurements on CT or MRI versus DEXA scan: a systematic review . N Am Spine Soc J . 2023 ;14 :100204 . doi: 10.1016/j.xnsj.2023.100204 . 37090222 PMC10119682
38 Mousavi SZ , Moshfeghinia R , Molavi Vardanjani H , et al. Opportunistic screening of osteoporosis by CT scan compared to DXA: a systematic review and meta-analysis . Clin Imaging . 2025 ;118 :110372 . doi: 10.1016/j.clinimag.2024.110372 . 39615271
39 Paderno A , Ataide Gomes EJ , Gilberg L , et al. Artificial intelligence-enhanced opportunistic screening of osteoporosis in CT scan: a scoping review . Osteoporos Int . 2024 ;35 (10 ):1681 –1692 . doi: 10.1007/s00198-024-07179-1 . 38985200
40 Yang J , Liao M , Wang Y , et al. Opportunistic osteoporosis screening using chest CT with artificial intelligence . Osteoporos Int . 2022 ;33 (12 ):2547 –2561 . doi: 10.1007/s00198-022-06491-y . 35931902
Publication and source details

Original title: Computed tomography-measured trabecular attenuation at first lumbar vertebra as a surrogate marker of bone mineral density and osteoporosis in patients undergoing hemodialysis

Takahiro Yajima; Ai Kurisawa; Maiko Arao

Renal Failure · 2026

CONTACT Takahiro Yajima yajima5639@gmail.com Department of Nephrology, Matsunami General Hospital, 185-1 Dendai, Kasamatsu, Gifu, 501–6062, Japan© 2026 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group.2026The Author(s)https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The terms on which this article has been published allow the posting of the Accepted Manuscript in a repository by the author(s) or with their consent.

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-10T22:30:02.031387+00:00

DOI: 10.1080/0886022x.2026.2671455 · PMC13195716