Vitamin D3 for Life. Live Enlightened.

Research libraryVitamin D3 For Life
Study design and methods

Primary relevance to vitamin D Vitamin D is a stated subject of this paper.

Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.

Why this paper is included

Supporting source evidence:

Statistical analysis showed no statistical significance results (P value 0.277) regarding the positive correlation between vitamin D levels and implant success/ failure, it also showed no statistical significance (P value 0.663) regarding the relationship between Vitamin D levels and implant success/failure based on the implant location.

Source: Abstract. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Cohort study.

Cohort study

Examines exposures and outcomes over time within a defined group.

Meta-analysis unclear · Blinding unclear / not reported · Human research reported

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

Correlation between vitamin D blood levels and implant success: a prospective cohort study

Source: Article title.

After implant placement, patients were not advised to receive any supplements for 3 months.

Source: Abstract.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Abstracts

Correlation between vitamin D blood levels and implant success: a prospective cohort study

Cohort study · BMC Oral Health · 2026

Original publication title

Correlation between vitamin D blood levels and implant success: a prospective cohort study

Shaimaa Saieed Nasr; Ramy Moustafa Moustafa Ali; Rania Ihab Younis; Shahinaz Gamaleldin Mohamed Elashiry; Nabil Ahmad Ibrahim; Mohamed Hamdy Mahmoud Ismail

© The Author(s) 2026

Original publication · Publisher record · CC BY 4.0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

Authors’ conclusion

Serum vitamin D level has no direct effect on the success or failure of dental implants.

An extract from the source publication. Read it in context.

At a glance

Abstract: What objectives does the paper state?

The aim of this study was to find out if there was a correlation between serum vitamin D levels and implant success.

Source: Aim

Abstract: What methods does the paper describe?

This study was conducted on 100 patients divided into two equal groups who received single dental implant to restore single missing tooth. After implant placement, patients were not advised to receive any supplements for 3 months. Patient’s serum level of vitamin D was tested after 3 months of implant placement (osseointegration period). Clinical and radiographic assessment of dental implants were performed after 3 months postoperatively.

Source: Methods

Abstract: Results

Statistical analysis showed no statistical significance results (P value 0.277) regarding the positive correlation between vitamin D levels and implant success/ failure, it also showed no statistical significance (P value 0.663) regarding the relationship between Vitamin D levels and implant success/failure based on the implant location.

Source: Results

Abstract: Conclusion

Serum vitamin D level has no direct effect on the success or failure of dental implants.

Source: Conclusion
Authors’ abstract

Background

Vitamin D is a fat-soluble hormone that can be produced in the skin by Ultra-Violet (UV) light exposure or acquired through diet. Vitamin D is currently of relevance to dentists placing dental implants because it plays a role in bone metabolism and controls the immune system. There is some evidence that the osseointegration process of dental implants is favorably correlated with the proper concentration of this prohormone. Several studies have demonstrated that vitamin D may be crucial for both the integration of the implant into bone tissue and the postoperative tissue repair process.

Aim

The aim of this study was to find out if there was a correlation between serum vitamin D levels and implant success.

Methods

This study was conducted on 100 patients divided into two equal groups who received single dental implant to restore single missing tooth. After implant placement, patients were not advised to receive any supplements for 3 months. Patient’s serum level of vitamin D was tested after 3 months of implant placement (osseointegration period). Clinical and radiographic assessment of dental implants were performed after 3 months postoperatively.

Results

Statistical analysis showed no statistical significance results (P value 0.277) regarding the positive correlation between vitamin D levels and implant success/ failure, it also showed no statistical significance (P value 0.663) regarding the relationship between Vitamin D levels and implant success/failure based on the implant location.

Conclusion

Serum vitamin D level has no direct effect on the success or failure of dental implants.

Publication and source details

Original title: Correlation between vitamin D blood levels and implant success: a prospective cohort study

Shaimaa Saieed Nasr; Ramy Moustafa Moustafa Ali; Rania Ihab Younis; Shahinaz Gamaleldin Mohamed Elashiry; Nabil Ahmad Ibrahim; Mohamed Hamdy Mahmoud Ismail

BMC Oral Health · 2026

© The Author(s) 20262026https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.Open access funding provided by The Science, Technology & Innovation Funding Authority (STDF) in cooperation with The Egyptian Knowledge Bank (EKB). This research was self-funded.

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-26T17:31:06.527268+00:00

DOI: 10.1186/s12903-026-09885-0 · PMC13770324