Secondary relevance to vitamin D This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.
This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.
Why this paper is included
Supporting source evidence:
All analytes had a sample type where the percentage difference concentration between 2-hour and 24-hour processed samples was ≤4% and was acceptable based on calculated limits, including for biomarkers of vitamin A, vitamin D, thiamin, folate, vitamin B-12, iron (ferritin), and zinc status and for selected clinical markers, C-reactive protein, HDL and total cholesterol, and triglycerides.
Source: Abstract. View original paper
Relevance classification does not establish study quality, causation or editorial approval.
Study design Study design awaiting verification.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.
Meta-analysis unclear · Blinding unclear / not reported · Human research reported
How this paper was classified
Automatic source-based classification; awaiting editorial verification. This is not a quality score.
Participants were male and female MRC EWL staff who voluntarily agreed to take part in the study, which was approved by the Cambridge Local Research Ethics Committee.
Source: Methods.
What the study types mean
- Systematic review
- Uses explicit methods to identify, assess and summarise research on a defined question.
- Scoping review
- Maps the extent and characteristics of research on a topic.
- Narrative review
- Discusses existing research; systematic-review methods have not been established by this classification.
- Review / evidence synthesis
- Reviews existing research; the exact review methods need further assessment.
- Randomised controlled trial
- Assigns participants or groups to comparison interventions by chance.
- Non-randomised intervention study
- Examines an intervention without random allocation.
- Cohort study
- Examines exposures and outcomes over time within a defined group.
- Case-control study
- Compares people with an outcome against people without it, examining exposures.
- Cross-sectional study
- Examines a population at a particular point in time.
- Observational study
- Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
- Case report
- Describes an individual case.
- Case series
- Describes a group of individual cases.
- Secondary analysis
- Analyses existing study data; this paper is not automatically another independent trial.
- Laboratory study
- Investigates biological processes in a laboratory setting.
- Qualitative study
- Examines experiences or meanings using qualitative methods.
- Genetic instrumental-variable study
- Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
- Study protocol
- Describes planned methods and is not evidence that the planned study has reported results.
- Multiple reported designs
- More than one design is explicitly reported; examine the supporting methods.
- Study design awaiting verification
- The available source does not establish a sufficiently clear study design.
Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.
Abstracts
Delayed Processing of Chilled Whole Blood for 24 Hours Does Not Affect the Concentration of the Majority of Micronutrient Status Biomarkers
Study design awaiting verification · The Journal of Nutrition · 2021
Original publication title
Delayed Processing of Chilled Whole Blood for 24 Hours Does Not Affect the Concentration of the Majority of Micronutrient Status Biomarkers
© The Author(s) 2021. Published by Oxford University Press on behalf of the American Society for Nutrition.
Original publication · Publisher record · CC BY 4.0
Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.
At a glance
Abstract: What objectives does the paper state?
The objective was to investigate the effects of delayed processing of whole blood on the stability of 25 micronutrient and selected clinical biomarkers.
Source: ObjectivesAbstract: What methods does the paper describe?
Blood from 16 healthy adults was collected into EDTA, lithium heparin (LH), or serum tubes. Samples were processed within 2 hours of collection (“2-hour processed”) or mailed overnight (boxed with frozen cold packs) before processing (“24-hour processed”). Micronutrient and clinical biomarker concentrations were quantified with validated methods. The concentration percentage difference between the 2: and 24-hour processed samples was calculated and was compared against quality specifications determined from intra: and interindividual variations.
Source: MethodsAbstract: Results
All analytes had a sample type where the percentage difference concentration between 2-hour and 24-hour processed samples was ≤4% and was acceptable based on calculated limits, including for biomarkers of vitamin A, vitamin D, thiamin, folate, vitamin B-12, iron (ferritin), and zinc status and for selected clinical markers, C-reactive protein, HDL and total cholesterol, and triglycerides. EDTA plasma vitamin C was lower compared to the 2-hour processed sample (geometric mean, 43%; 95% CI: 36%: 49%). Pyridoxal-5-phosphate (vitamin B-6 biomarker) decreased, with differences from the 2-hour processed samples of −8% (95% CI: −13% to −2%) and −14% (95% CI: −18% to −9%) in LH plasma and serum, respectively.
Source: ResultsAbstract: Conclusions
In blood collected from adult participants, delayed processing of chilled whole blood for 24 hours did not materially affect the measured concentrations of the majority of micronutrients and selected clinical biomarkers. This suggests that for these analytes, adherence to a 2-hour processing protocol may be unnecessary. This knowledge is valuable and may help to simplify logistics for sample transport and processing of blood samples for micronutrient status assessment.
Source: ConclusionsAuthors’ abstract
ABSTRACT
Background
The measurement of micronutrient status is essential to understand the health of individuals and populations, but there are limited data on the stability of micronutrients in whole blood.
Objectives
The objective was to investigate the effects of delayed processing of whole blood on the stability of 25 micronutrient and selected clinical biomarkers.
Methods
Blood from 16 healthy adults was collected into EDTA, lithium heparin (LH), or serum tubes. Samples were processed within 2 hours of collection (“2-hour processed”) or mailed overnight (boxed with frozen cold packs) before processing (“24-hour processed”). Micronutrient and clinical biomarker concentrations were quantified with validated methods. The concentration percentage difference between the 2: and 24-hour processed samples was calculated and was compared against quality specifications determined from intra: and interindividual variations.
Results
All analytes had a sample type where the percentage difference concentration between 2-hour and 24-hour processed samples was ≤4% and was acceptable based on calculated limits, including for biomarkers of vitamin A, vitamin D, thiamin, folate, vitamin B-12, iron (ferritin), and zinc status and for selected clinical markers, C-reactive protein, HDL and total cholesterol, and triglycerides. EDTA plasma vitamin C was lower compared to the 2-hour processed sample (geometric mean, 43%; 95% CI: 36%: 49%). Pyridoxal-5-phosphate (vitamin B-6 biomarker) decreased, with differences from the 2-hour processed samples of −8% (95% CI: −13% to −2%) and −14% (95% CI: −18% to −9%) in LH plasma and serum, respectively.
Conclusions
In blood collected from adult participants, delayed processing of chilled whole blood for 24 hours did not materially affect the measured concentrations of the majority of micronutrients and selected clinical biomarkers. This suggests that for these analytes, adherence to a 2-hour processing protocol may be unnecessary. This knowledge is valuable and may help to simplify logistics for sample transport and processing of blood samples for micronutrient status assessment.
Publication and source details
Original title: Delayed Processing of Chilled Whole Blood for 24 Hours Does Not Affect the Concentration of the Majority of Micronutrient Status Biomarkers
Kerry S Jones; Sarah R Meadows; Karen Chamberlain; Damon A Parkington; Dave Collins; Polly Page; Albert Koulman
The Journal of Nutrition · 2021
Address correspondence to KSJ (e-mail: kerry.jones@mrc-epid.cam.ac.uk).© The Author(s) 2021. Published by Oxford University Press on behalf of the American Society for Nutrition.2021https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (https://creativecommons.org/licenses/by/4.0/), which permits unrestricted reuse, distribution, and reproduction in any medium, provided the original work is properly cited. Medical Research Council Canada10.13039/501100007155 U105960384 National Institute for Health Research10.13039/501100000272 IS-BRC-1215- 20014Repository JATS snapshot; version as supplied
Source retrieved: 2026-11-11T12:40:09.666157+00:00
DOI: 10.1093/jn/nxab267 · PMC8564691