Vitamin D3 for Life

Live Enlightened

Research libraryVitamin D3 For Life
Study design and methods

Secondary relevance to vitamin D This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.

This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.

Why this paper is included

Supporting source evidence:

Mean % deviation for vitamin D (Figure 3b), higher than TCL, was reported at temperature greater than 30 °C for 12 hours or more.

Source: Result. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Cross-sectional study.

Cross-sectional study

Examines a population at a particular point in time.

Meta-analysis unclear · Blinding unclear / not reported · Human research reported

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

Blood from 420 volunteers was exposed to 2 to 8 °C, room temperature (RT), 22 to 30 °C and > 30 °C for 30 min, 6 hours, 12 hours and 24 hours prior to centrifugation.

Source: Abstract.

A cross sectional study was designed to assess the stability of biochemical indicators such as haemoglobin, HbA1c and folate in whole blood; ferritin, CRP, vitamin B12, vitamin A (retinol), vitamin D, zinc, sTfR, total cholesterol, HDL, LDL, TG, albumin, total protein and creatinine in serum and glucose in plasma, after exposing blood to different temperature and time periods prior to centrifugation and analysis.

Source: Methods.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Abstracts

Effect of temperature and time delay in centrifugation on stability of select biomarkers of nutrition and non-communicable diseases in blood samples

Cross-sectional study · Biochemia Medica · 2019

Original publication title

Effect of temperature and time delay in centrifugation on stability of select biomarkers of nutrition and non-communicable diseases in blood samples

Ransi Ann Abraham; Praween K. Agrawal; Rajib Acharya; Avina Sarna; Sowmya Ramesh; Robert Johnston; Arjan de Wagt; Nizamuddin Khan; Akash Porwal; Sucheta Banerjee Kurundkar; Arvind Pandey; Raghu Pullakhandam; Krishnapillai Madhavan Nair; Geeta Trilok Kumar; H P S Sachdev; Umesh Kapil; Renu Saxena; Sila Deb; Ajay Khera; Lakshmy Ramakrishnan

©Croatian Society of Medical Biochemistry and Laboratory Medicine.

Original publication · Publisher record · CC BY 4.0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

Authors’ conclusion

All analytes other than creatinine, folate and haemoglobin can be reliably estimated in blood samples exposed to 22-30°C for 12 hours in community-based studies.

An extract from the source publication. Read it in context.

At a glance

Abstract: What background does the paper provide?

Preanalytical conditions are critical for blood sample integrity and poses challenge in surveys involving biochemical measurements. A cross sectional study was conducted to assess the stability of select biomarkers at conditions that mimic field situations in surveys.

Source: Introduction

Abstract: What methods does the paper describe?

Blood from 420 volunteers was exposed to 2 to 8 °C, room temperature (RT), 22 to 30 °C and > 30 °C for 30 min, 6 hours, 12 hours and 24 hours prior to centrifugation. After different exposures, whole blood (N = 35) was used to assess stability of haemoglobin, HbA1c and erythrocyte folate; serum (N = 35) for assessing stability of ferritin, C-reactive protein (CRP), vitamins B12, A and D, zinc, soluble transferrin receptor (sTfR), total cholesterol, high density lipoprotein cholesterol (HDL), low density lipoprotein cholesterol (LDL), tryglicerides, albumin, total protein and creatinine; and plasma (N = 35) was used for glucose.

The mean % deviation of the analytes was compared with the total change limit (TCL), computed from analytical and intra-individual imprecision. Values that were within the TCL were deemed to be stable.

Source: Material and methods

Abstract: Result

Creatinine (mean % deviation 14.6, TCL 5.9), haemoglobin (16.4%, TCL 4.4) and folate (33.6%, TCL 22.6) were unstable after 12 hours at 22-30°C, a temperature at which other analytes were stable. Creatinine was unstable even at RT for 12 hours (mean % deviation: 10.4). Albumin, CRP, glucose, cholesterol, LDL, triglycerides, vitamins B12 and A, sTfR and HbA1c were stable at all studied conditions.

Source: Result

Abstract: Conclusion

All analytes other than creatinine, folate and haemoglobin can be reliably estimated in blood samples exposed to 22-30°C for 12 hours in community-based studies.

Source: Conclusion
Authors’ abstract

Introduction

Preanalytical conditions are critical for blood sample integrity and poses challenge in surveys involving biochemical measurements. A cross sectional study was conducted to assess the stability of select biomarkers at conditions that mimic field situations in surveys.

Material and methods

Blood from 420 volunteers was exposed to 2 to 8 °C, room temperature (RT), 22 to 30 °C and > 30 °C for 30 min, 6 hours, 12 hours and 24 hours prior to centrifugation. After different exposures, whole blood (N = 35) was used to assess stability of haemoglobin, HbA1c and erythrocyte folate; serum (N = 35) for assessing stability of ferritin, C-reactive protein (CRP), vitamins B12, A and D, zinc, soluble transferrin receptor (sTfR), total cholesterol, high density lipoprotein cholesterol (HDL), low density lipoprotein cholesterol (LDL), tryglicerides, albumin, total protein and creatinine; and plasma (N = 35) was used for glucose.

The mean % deviation of the analytes was compared with the total change limit (TCL), computed from analytical and intra-individual imprecision. Values that were within the TCL were deemed to be stable.

Result

Creatinine (mean % deviation 14.6, TCL 5.9), haemoglobin (16.4%, TCL 4.4) and folate (33.6%, TCL 22.6) were unstable after 12 hours at 22-30°C, a temperature at which other analytes were stable. Creatinine was unstable even at RT for 12 hours (mean % deviation: 10.4). Albumin, CRP, glucose, cholesterol, LDL, triglycerides, vitamins B12 and A, sTfR and HbA1c were stable at all studied conditions.

Conclusion

All analytes other than creatinine, folate and haemoglobin can be reliably estimated in blood samples exposed to 22-30°C for 12 hours in community-based studies.

Publication and source details

Original title: Effect of temperature and time delay in centrifugation on stability of select biomarkers of nutrition and non-communicable diseases in blood samples

Ransi Ann Abraham; Praween K. Agrawal; Rajib Acharya; Avina Sarna; Sowmya Ramesh; Robert Johnston; Arjan de Wagt; Nizamuddin Khan; Akash Porwal; Sucheta Banerjee Kurundkar; Arvind Pandey; Raghu Pullakhandam; Krishnapillai Madhavan Nair; Geeta Trilok Kumar; H P S Sachdev; Umesh Kapil; Renu Saxena; Sila Deb; Ajay Khera; Lakshmy Ramakrishnan

Biochemia Medica · 2019

* Corresponding author: lakshmy_ram@yahoo.com©Croatian Society of Medical Biochemistry and Laboratory Medicine.2018Croatian Society of Medical Biochemistryhttps://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution (http://creativecommons.org/licenses/by/4.0/) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-12T18:32:57.055237+00:00

DOI: 10.11613/bm.2019.020708 · PMC6559620