Vitamin D3 for Life

Live Enlightened

Research libraryVitamin D3 For Life
Study design and methods

Primary relevance to vitamin D Vitamin D is a stated subject of this paper.

Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.

Why this paper is included

Supporting source evidence:

In comparison to the original 25(OH)D levels, the standardized levels showed higher means overall and in age: and sex-specific analyses.

Source: Abstract. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Study design awaiting verification.

Study design awaiting verification

The available source does not establish a sufficiently clear study design.

Meta-analysis unclear · Blinding unclear / not reported · Research setting awaiting verification

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Abstracts

Implications of standardization of serum 25-hydroxyvitamin D data for the evaluation of vitamin D status in Germany, including a temporal analysis

Study design awaiting verification · BMC Public Health · 2018

Original publication title

Implications of standardization of serum 25-hydroxyvitamin D data for the evaluation of vitamin D status in Germany, including a temporal analysis

Martina Rabenberg; Christa Scheidt-Nave; Markus A. Busch; Michael Thamm; Nina Rieckmann; Ramón A. Durazo-Arvizu; Kirsten G. Dowling; Zuzana Škrabáková; Kevin D. Cashman; Christopher T. Sempos; Gert B. M. Mensink

© The Author(s). 2018

Original publication · Publisher record · CC BY 4.0 · CC0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

Authors’ conclusion

The use of standardization of 25(OH)D levels has a substantial impact on estimates of the vitamin D status in Germany. Since clinical diagnostic, therapeutic and public health decision-making require valid and comparable data, standardization and calibration of commercial, clinical and research laboratory assays for 25(OH)D measurement should become common practice. Until then, researchers, health practitioners and policy makers should be aware of the peculiarities of the measurement methods when comparing and interpreting 25(OH)D levels.

An extract from the source publication. Read it in context.

At a glance

Abstract: What background does the paper provide?

Comparability of 25-hydroxyvitamin D (25(OH)D) measurements is hampered by method-related differences in measurement values. International standardization of laboratory assays has been suggested to solve this problem.

Source: Background

Abstract: What methods does the paper describe?

As part of the European Commission: funded project ‘Food-based solutions for optimal vitamin D nutrition and health through the life cycle’ (ODIN), original measurements of serum 25(OH)D of three German national health surveys conducted between 1998 and 2011 have been standardized retrospectively. In these representative population-based samples including persons aged between 1 and 79 years, the original 25(OH)D values were compared with those after standardization. Mean values and prevalences of vitamin D deficiency, insufficiency, and sufficiency (25(OH)D levels < 30, 30: < 50, and > =50 nmol/l, respectively) were calculated by sex and age groups based on original and standardized 25(OH)D data.

Source: Methods

Abstract: Results

In comparison to the original 25(OH)D levels, the standardized levels showed higher means overall and in age: and sex-specific analyses. After standardization, the prevalence of vitamin D deficiency was lower in all surveys while the prevalence of vitamin D sufficiency was higher. Nevertheless, even after standardization ~ 15% of adults and 12.5% of children had serum 25(OH)D levels < 30 nmol/l. Thus, the proportion of deficient vitamin D levels in the German population is still considerable.

Source: Results

Abstract: Conclusions

The use of standardization of 25(OH)D levels has a substantial impact on estimates of the vitamin D status in Germany. Since clinical diagnostic, therapeutic and public health decision-making require valid and comparable data, standardization and calibration of commercial, clinical and research laboratory assays for 25(OH)D measurement should become common practice. Until then, researchers, health practitioners and policy makers should be aware of the peculiarities of the measurement methods when comparing and interpreting 25(OH)D levels.

Source: Conclusions
Authors’ abstract

Background

Comparability of 25-hydroxyvitamin D (25(OH)D) measurements is hampered by method-related differences in measurement values. International standardization of laboratory assays has been suggested to solve this problem.

Methods

As part of the European Commission: funded project ‘Food-based solutions for optimal vitamin D nutrition and health through the life cycle’ (ODIN), original measurements of serum 25(OH)D of three German national health surveys conducted between 1998 and 2011 have been standardized retrospectively. In these representative population-based samples including persons aged between 1 and 79 years, the original 25(OH)D values were compared with those after standardization. Mean values and prevalences of vitamin D deficiency, insufficiency, and sufficiency (25(OH)D levels < 30, 30: < 50, and > =50 nmol/l, respectively) were calculated by sex and age groups based on original and standardized 25(OH)D data.

Results

In comparison to the original 25(OH)D levels, the standardized levels showed higher means overall and in age: and sex-specific analyses. After standardization, the prevalence of vitamin D deficiency was lower in all surveys while the prevalence of vitamin D sufficiency was higher. Nevertheless, even after standardization ~ 15% of adults and 12.5% of children had serum 25(OH)D levels < 30 nmol/l. Thus, the proportion of deficient vitamin D levels in the German population is still considerable.

Conclusions

The use of standardization of 25(OH)D levels has a substantial impact on estimates of the vitamin D status in Germany. Since clinical diagnostic, therapeutic and public health decision-making require valid and comparable data, standardization and calibration of commercial, clinical and research laboratory assays for 25(OH)D measurement should become common practice. Until then, researchers, health practitioners and policy makers should be aware of the peculiarities of the measurement methods when comparing and interpreting 25(OH)D levels.

Publication and source details

Original title: Implications of standardization of serum 25-hydroxyvitamin D data for the evaluation of vitamin D status in Germany, including a temporal analysis

Martina Rabenberg; Christa Scheidt-Nave; Markus A. Busch; Michael Thamm; Nina Rieckmann; Ramón A. Durazo-Arvizu; Kirsten G. Dowling; Zuzana Škrabáková; Kevin D. Cashman; Christopher T. Sempos; Gert B. M. Mensink

BMC Public Health · 2018

© The Author(s). 2018https://creativecommons.org/licenses/by/4.0/Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.http://dx.doi.org/10.13039/501100003107Bundesministerium für Gesundheithttp://dx.doi.org/10.13039/501100002347Bundesministerium für Bildung und Forschunghttp://dx.doi.org/10.13039/501100005908Bundesministerium für Ernährung und Landwirtschaft

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-11T21:20:39.620702+00:00

DOI: 10.1186/s12889-018-5769-y · PMC6035438