Secondary relevance to vitamin D This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.
This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.
Why this paper is included
Supporting source evidence:
In the explanatory model, only total calcium, pH, and sex independently predicted iCa (all variance inflation factors < 1.8); albumin, phosphate and vitamin D were not significant.
Source: Abstract. View original paper
Relevance classification does not establish study quality, causation or editorial approval.
Study design Cohort study.
Cohort study
Examines exposures and outcomes over time within a defined group.
Meta-analysis unclear · Blinding unclear / not reported · Human research reported
How this paper was classified
Automatic source-based classification; awaiting editorial verification. This is not a quality score.
In this prospective observational cohort study, ionised calcium (iCa), total calcium, albumin, venous pH, creatinine, estimated glomerular filtration rate (eGFR), C-reactive protein (CRP), procalcitonin, magnesium, phosphate and vitamin D were measured simultaneously.
Source: Abstract.
Patients were included if aged ≥ 18 years with simultaneously measured serum total calcium, serum albumin and ionised calcium, plus same-day venous pH, creatinine, estimated glomerular filtration rate (eGFR), C-reactive protein (CRP), procalcitonin, magnesium and phosphate.
Source: Methods.
What the study types mean
- Systematic review
- Uses explicit methods to identify, assess and summarise research on a defined question.
- Scoping review
- Maps the extent and characteristics of research on a topic.
- Narrative review
- Discusses existing research; systematic-review methods have not been established by this classification.
- Review / evidence synthesis
- Reviews existing research; the exact review methods need further assessment.
- Randomised controlled trial
- Assigns participants or groups to comparison interventions by chance.
- Non-randomised intervention study
- Examines an intervention without random allocation.
- Cohort study
- Examines exposures and outcomes over time within a defined group.
- Case-control study
- Compares people with an outcome against people without it, examining exposures.
- Cross-sectional study
- Examines a population at a particular point in time.
- Observational study
- Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
- Case report
- Describes an individual case.
- Case series
- Describes a group of individual cases.
- Secondary analysis
- Analyses existing study data; this paper is not automatically another independent trial.
- Laboratory study
- Investigates biological processes in a laboratory setting.
- Qualitative study
- Examines experiences or meanings using qualitative methods.
- Genetic instrumental-variable study
- Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
- Study protocol
- Describes planned methods and is not evidence that the planned study has reported results.
- Multiple reported designs
- More than one design is explicitly reported; examine the supporting methods.
- Study design awaiting verification
- The available source does not establish a sufficiently clear study design.
Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.
Abstracts
Limited diagnostic utility of albumin-corrected calcium in the intensive care unit: A prospective comparison with ionised calcium
Cohort study · PLOS One · 2026
Original publication title
Limited diagnostic utility of albumin-corrected calcium in the intensive care unit: A prospective comparison with ionised calcium
© 2026 Özdemir et al
Original publication · Publisher record · CC BY 4.0
Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.
At a glance
Abstract: What background does the paper provide?
Albumin-adjusted calcium is widely used despite uncertainty about its accuracy in critically ill adults. We prospectively evaluated the diagnostic performance of total calcium and of multiple published albumin-correction formulae against ionised calcium, the physiological reference standard, in an intensive care unit (ICU) cohort.
Source: BackgroundAbstract: What methods does the paper describe?
In this prospective observational cohort study, ionised calcium (iCa), total calcium, albumin, venous pH, creatinine, estimated glomerular filtration rate (eGFR), C-reactive protein (CRP), procalcitonin, magnesium, phosphate and vitamin D were measured simultaneously. The primary outcome was the diagnostic accuracy (area under the ROC curve [AUC]; sensitivity/specificity) of total calcium and of corrected calcium for detecting hypocalcaemia, defined a priori by the reference standard as iCa < 1.12 mmol/L; the pre-specified contrast was the difference between the two correlated AUCs. Twelve published measures were compared (total calcium; Payne; simplified Payne; Orrell; Berry; James; Jain; Thode; and the Pekar and Antonio estimators).
Agreement, formal subgroup interaction tests, an explanatory multivariable model with collinearity diagnostics, and an exploratory internally-validated ICU equation were assessed.
Source: MethodsAbstract: Results
In total, 250 patients were enrolled (median age 70 years; 147 men, 58.8%). Hypocalcaemia prevalence was 58.0% (n = 145). Payne-corrected calcium correctly identified only 15.2% of truly hypocalcaemic patients (Cohen κ = 0.08), versus 62.8% for total calcium (κ = 0.40). No simple albumin-correction formula significantly outperformed unadjusted total calcium (AUC 0.69 to 0.75; all DeLong p > 0.05 vs total calcium AUC 0.74). Only the four-variable Pekar estimator achieved a higher AUC (0.78; p = 0.005). In the explanatory model, only total calcium, pH, and sex independently predicted iCa (all variance inflation factors < 1.8); albumin, phosphate and vitamin D were not significant.
An exploratory ICU-specific equation reached an optimism-corrected R² of only 0.17.
Source: ResultsAbstract: Conclusions
Albumin-corrected calcium, including all established formulae tested, provides no diagnostic benefit over total calcium in the ICU and frequently masks true hypocalcaemia. Direct ionised-calcium measurement should be prioritised when accurate calcium status affects management. These are diagnostic-accuracy findings; their clinical-outcome implications require outcome-anchored study.
Source: ConclusionsAuthors’ abstract
Background
Albumin-adjusted calcium is widely used despite uncertainty about its accuracy in critically ill adults. We prospectively evaluated the diagnostic performance of total calcium and of multiple published albumin-correction formulae against ionised calcium, the physiological reference standard, in an intensive care unit (ICU) cohort.
Methods
In this prospective observational cohort study, ionised calcium (iCa), total calcium, albumin, venous pH, creatinine, estimated glomerular filtration rate (eGFR), C-reactive protein (CRP), procalcitonin, magnesium, phosphate and vitamin D were measured simultaneously. The primary outcome was the diagnostic accuracy (area under the ROC curve [AUC]; sensitivity/specificity) of total calcium and of corrected calcium for detecting hypocalcaemia, defined a priori by the reference standard as iCa < 1.12 mmol/L; the pre-specified contrast was the difference between the two correlated AUCs. Twelve published measures were compared (total calcium; Payne; simplified Payne; Orrell; Berry; James; Jain; Thode; and the Pekar and Antonio estimators).
Agreement, formal subgroup interaction tests, an explanatory multivariable model with collinearity diagnostics, and an exploratory internally-validated ICU equation were assessed.
Results
In total, 250 patients were enrolled (median age 70 years; 147 men, 58.8%). Hypocalcaemia prevalence was 58.0% (n = 145). Payne-corrected calcium correctly identified only 15.2% of truly hypocalcaemic patients (Cohen κ = 0.08), versus 62.8% for total calcium (κ = 0.40). No simple albumin-correction formula significantly outperformed unadjusted total calcium (AUC 0.69 to 0.75; all DeLong p > 0.05 vs total calcium AUC 0.74). Only the four-variable Pekar estimator achieved a higher AUC (0.78; p = 0.005). In the explanatory model, only total calcium, pH, and sex independently predicted iCa (all variance inflation factors < 1.8); albumin, phosphate and vitamin D were not significant.
An exploratory ICU-specific equation reached an optimism-corrected R² of only 0.17.
Conclusions
Albumin-corrected calcium, including all established formulae tested, provides no diagnostic benefit over total calcium in the ICU and frequently masks true hypocalcaemia. Direct ionised-calcium measurement should be prioritised when accurate calcium status affects management. These are diagnostic-accuracy findings; their clinical-outcome implications require outcome-anchored study.
Publication and source details
Original title: Limited diagnostic utility of albumin-corrected calcium in the intensive care unit: A prospective comparison with ionised calcium
Erdoğan Özdemir; Turgay Yılmaz; Deccane Düzenci
PLOS One · 2026
* E-mail: erdoganozdemir@live.comCompeting Interests: The authors have declared that no competing interests exist.
Repository JATS snapshot; version as supplied
Source retrieved: 2026-11-10T22:04:56.707025+00:00
DOI: 10.1371/journal.pone.0354233 · PMC13387552