Vitamin D3 for Life. Live Enlightened.

Research libraryVitamin D3 For Life
Study design and methods

Primary relevance to vitamin D Vitamin D is a stated subject of this paper.

Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.

Why this paper is included

Supporting source evidence:

There was a significant difference in the postoperative VIS between patients with vitamin D deficiency, i.e., <20 ng/mL, and patients with vitamin D values > 20 ng/mL (3.5 vs. 1.3 p < 0.04).

Source: Abstract. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Study design awaiting verification.

Study design awaiting verification

The available source does not establish a sufficiently clear study design.

Meta-analysis unclear · Blinding unclear / not reported · Human research reported

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

After heart surgery, all patients were monitored in the ICU.

Source: Methods.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Full studies

Lower Levels of Vitamin D Are Associated with Higher Vasoactive-Inotropic Scores in Major Cardiac Surgery

Study design awaiting verification · Life · 2024

Original publication title

Lower Levels of Vitamin D Are Associated with Higher Vasoactive–Inotropic Scores in Major Cardiac Surgery

Adrian Stef; Constantin Bodolea; Simona Sorana Cainap; Monica Muntean; Aurelia Georgeta Solomonean; Nadina Tintiuc; Razvan Olimpiu Mada; Gabriel Cismaru

© 2024 by the authors.

Original publication · Publisher record · CC BY 4.0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

Authors’ conclusion

The vasoactive–inotropic score was shown to be associated with preoperative vitamin D levels. Patients with vitamin D levels below 20 ng/mL had greater postoperative VISs compared to patients with levels over 20 ng/mL. A VIS above 15 was linked to an extended duration of hospitalization and a prolonged stay in the ICU. A significant correlation was seen between the VIS and the duration of hospitalization, the days of stay in the intensive care unit, and the duration of mechanical ventilation.

Both vitamin D levels and the VIS were predictive of postoperative acute kidney injury.

An extract from the source publication. Read it in context.

At a glance

Study background

What background does the paper provide?

Unfavorable outcomes after major surgery can be predicted using scoring systems [1]. Nevertheless, EuroScore II, STS risk score, and Parsonnet score were specifically designed to predict the prognosis following cardiac surgery by considering preoperative factors rather than postoperative data [2,3,4]. The vasoactive–inotropic score (VIS) is determined by quantifying the combined effects of inotropes and vasoconstrictors for maintaining hemodynamic balance. A greater score indicates a more significant hemodynamic impairment. Gaies et al. [5], Wernovski et al. [6], and Favia et al. [7] established the validity of the VIS in predicting adverse outcomes in pediatric populations requiring heart surgery.

Previously conducted studies suggest that vitamin D is involved in vascular and cardiac function [8] and reduces the risk of arrhythmia [9]. A recent study showed no significant difference in the vitamin D supplementation group in terms of ICU stay, hospital stay, or duration of mechanical ventilation [10]. Nevertheless, a recent systematic review revealed contradictory findings concerning the overall survival and duration of stay in the intensive care unit (ICU) associated with vitamin D levels [11].

In our study, we investigated whether vitamin D levels and the VIS could predict unfavorable outcomes after major cardiac surgery in adult patients.

Source: 1. Introduction Source: 1. Introduction Source: 1. Introduction

Study methods

What methods does the paper describe?

The present study was structured as a retrospective, single-arm, observational investigation conducted at a single cardiac surgery center and approved by the “Iuliu Hatieganu” University of Medicine Ethics Committee (approval number 259 on 28 September 2023). All patients who underwent major heart surgery (aortic or mitral valve procedures, coronary artery bypass, aortic valve and ascending aorta repair, aortic aneurysm repair, or association between CABG and other valve procedures) from 1 October 2021 to 28 February 2022 were selected for inclusion in the study, which specifically focused on patients who underwent preoperative evaluations of 25-OH vitamin D levels: The research was conducted in accordance with the principles of the Declaration of Helsinki and Good Clinical Practice Guidelines.

The requirement to obtain patient consent was waived because the data analysis was retrospective.

The exclusion criteria included age <18 years, emergency need for surgery, patients with hemodynamic instability referred for major cardiovascular surgery, patients who had catheter-based transfemoral aortic valve replacement, aortic arch intervention, or descending aortic surgery, patients that took vitamin D supplements prior to surgery, and patients with a hospital length of stay less than 24 h (transferred to other cardiac facilities). After heart surgery, all patients were monitored in the ICU. The administration of inotropic drugs such as dobutamine, dopamine, epinephrine, norepinephrine, milrinone, and vasopressin was started in the case of reduced cardiac output associated with hypotension.

Pharmacological responses to vasoactive and inotropic drugs were monitored, and the administration of these drugs was adjusted to the minimum necessary dosage rates to sustain sufficient cardiac output and blood pressure. The early postoperative use of vasoactive drugs can prevent multi-organ ischemia and dysfunction, and infusion was rapidly terminated or the rate decreased once the patient achieved circulatory stability. Vitamin D levels were correlated with VIS, cardiopulmonary bypass perfusion time, cross-clamp time, mechanical ventilation time, length of stay in the ICU, total length of stay in the hospital, and duration of mechanical ventilation.

The patients were registered in a single database, consisting of demographic, clinical, and postoperative information extracted from our internal hospital database. The data were transferred to an Excel spreadsheet and then to an SPSS file. All measurements for 25 OH vitamin D were conducted from venous blood using the Biotek Microplate 50 TS washer (Agilent Technologies Inc., Santa Clara, CA, USA) and the 800 TS reader (Agilent Technologies Inc., Santa Clara, CA, USA). Vitamin D deficiency was defined as a 25(OH)D3 level of <20 ng/mL; vitamin D insufficiency was defined as a 25(OH)D3 level of 20–30 ng/mL; and normal vitamin D levels were defined as a 25(OH)D3 level of at least 30 ng/mL.

Postoperative hemorrhage, renal dysfunction following surgical intervention, food restrictions, and fluid infusions are known to alter the postoperative status of vitamin D. Therefore, our analysis exclusively considered preoperative vitamin D levels to assess whether they could serve as a predictor of the patient’s postoperative outcome.

For calculating the VIS, the patient’s medical record was reviewed to determine the administration rate of vasoactive medications and inotropes. The cutoff for a high and low VIS was a score of 15 points [12].

Statistical Methods

Categorical variables were expressed as counts and proportions, while continuous variables were reported using the median together with ± the interquartile range. When suitable, correlations were conducted using Pearson or Spearman methodologies. Where suitable, Student’s T test or the Mann–Whitney U test were used to compare continuous variables. A comparison of categorical variables was conducted using the chi-square test. Outcomes following surgery were predicted using receiver operator curves (ROCs), which were also used to ascertain the specificity, sensitivity, and cutoff values of vitamin D and VIS for predicting unfavorable outcomes.

All analyses were conducted using SPSS version 23.0 (IBM SPSS Inc., Chicago, IL, USA). Statistical significance was defined as p-values less than 0.05.

Source: 2. Materials and Methods Source: 2. Materials and Methods Source: 2. Materials and Methods Source: 2. Materials and Methods Source: 2. Materials and Methods

Study limitations

Discussion: What limitations does the paper describe?

This study is limited by its observational nature, which, despite multivariable adjustments for multiple potential confounders, predisposes it to residual and unobserved confounding. Its observational nature also precluded the establishment of causality. Additionally, the relatively low event rates for some of the outcomes reduced the reliability of our findings, which cannot be applied broadly because of the limited sample size (n = 83). We believe that an increased patient population in a multicenter study would have yielded a more rigorous statistical result.

Another important limitation of this study was its single-center design, which may introduce biases related to certain surgical techniques or patient demographics. For different cardiac surgery units that may have variations in terms of vasoactive and inotropic drug treatment regimens and the availability of mechanical cardiovascular support devices, adjustment of the VIS cutoff may be necessary. Further, larger prospective studies addressing the above issues are warranted to offer more proof of the link between vitamin D levels and surgical outcomes.

Source: Limitations

Results

Between 1 October 2021 and 28 February 2022, 300 patients underwent major cardiac intervention at our institution: aortic or mitral valve procedures, coronary artery bypass, aortic valve and ascending aorta repair, aortic aneurysm repair, or association between CABG and other valve procedures. Eighty-three of them had a 25-OH vitamin D measurement taken before surgery and were included in this study. The median age was 66 years (range 38–81); the median value of 25-OH vitamin D was 16.0 ng/mL (IQR 15.0–19.0); and the plasma level was below 20 ng/mL in 65 patients (78.3%) and >20 ng/mL in 18 patients (21.7%).

No significant difference in sex (p = 0.536), age (p = 0.512), BMI (p = 0.634), days of hospitalization (p = 0.808), days of hospitalization in the ICU (p = 0.421), duration of mechanical ventilation (0.563), CPB time (p = 0.968), or clamping time (p = 0.569) was found between the two vitamin D groups. However, after excluding one outlier patient that had 44 days of hospitalization, the statistical analysis yielded a p-value of 0.77 for the difference in hospitalization days between the two vitamin D groups and a p-value of 0.042 for the difference in ICU stay.

However, there was a significant difference in the postoperative VIS between patients with vitamin D deficit values < 20 ng/zl and patients with normal vitamin D values > 20 ng/mL (3.5 vs. 1.3; p < 0.04) (Table 1). The vasopressors and inotropes used were dopamine in 6 patients (mean dose: 2.7 ± 0.7 mcg/kg/min), dobutamine in 27 patients (mean dose: 3.0 ± 1.8 mcg/kg/min), epinephrine in 3 patients (mean dose: 0.04 ± 0.02 mcg/kg/min), and norepinephrine in 26 patients (mean dose: 0.05 ± 0.09 mcg/kg/min).

To obtain the vasoactive–inotropic score (VIS), the weighted sum of all prescribed inotropes and vasoconstrictors was computed using the following formula:

VIS = dopamine (µg/kg/min) + dobutamine (µg/kg/min) + 100 × epinephrine (µg/kg/min) + 100 × norepinephrine (µg/kg/min) + 10 × milrinone (µg/kg/min) + 10,000 × vasopressin (units/kg/min) + 50 × levosimendan (µg/kg/min) [13]. The cutoff for a high and low VIS was a score of 15 points; therefore, we divided our cohort into two groups based on VIS < 15 or ≥15. There was no significant difference in age (p = 0.395), sex (p = 0.511), BMI (p = 0.942), CPB time (p = 0.456), clamping time (p = 0.372), or mechanical ventilation time (p = 0.735) between the two VIS groups according to the 15-point cutoff.

However, patients with a VIS >15 had a prolonged stay in the hospital (16 ± 1.4 vs. 10 ± 4.9 days) and in the ICU (11 ± 8.4 vs. 3.7 ± 4.9 days) compared to patients with a VIS < 15 (p < 0.05) (Table 2).

We also found a significant correlation between the VIS and days of hospitalization (r = 0.335; p = 0.002), days of stay in the ICU (r = 0.547; p < 0.00001), and mechanical ventilation time (r = 0.327; p = 0.025).

The univariate regression analysis indicated that there was an association between age [OR 1.1; 95% CI 1.02–1.2; p = 0.013], VIS [OR 1.4; 95% CI 1.005–1.937; p = 0.04], CPB time [OR 1.015; 95% CI 1.003–1.03; p = 0.018], clamping time [OR 1.022; 95% CI 1.005–1.04; p = 0.01], and a longer ICU stay.

Variables found to be significantly associated with ICU stay in the univariate analysis (p < 0.05) were included in the multivariate regression analysis, which showed an association only between VIS and ICU stay. Patients with a high VIS had significantly greater odds of having a longer ICU stay [OR 1.4; 95% confidence interval (CI) 1.1–1.7; p = 0.005].

We considered two groups based on major surgery: low complexity (single aortic or mitral valve procedures, coronary artery bypass) and high complexity (aortic valve + ascending aorta repair, aortic aneurysm repair, association between CABG + valve procedures, multiple-valve procedures).

We compared the two groups, low complexity vs. high complexity, and found significant differences in terms of VIS (2.9 vs. 6.5; p = 0.01), duration of mechanical ventilation (5.7 vs. 8.2 h; p = 0.04), ICU stay (3.4 vs. 5.9 days; p = 0.04), days of hospitalization (10.2 vs. 12.5; p = 0.05), CPB time (83 vs. 147 min; p = 0.001), and clamping time (63 vs. 120 min; p = 0.0001).

We compared patients with vitamin D deficit values < 20 ng/zl and patients with normal vitamin D values > 20. In the high-complexity group, we found a significant difference in postoperative VIS (6.2 vs. 8.0; p = 0.04), mechanical ventilation time (9.2 vs. 3.6 h; p = 0.004), ICU stay (6.5 vs. 3.0; p = 0.421), days of hospitalization (12.8 vs. 11 p = 0.03), CPB time (156 vs. 105 min; p = 0.01), and clamping time (128 vs. 79; p = 0.01).

However, there was no significant difference in the low-complexity group (p > 0.60 for all tests).

Using receiver operating curves (ROCs), we found that vitamin D levels predicted postoperative acute kidney injury (AUC, 0.662; 95% CI, 0.52–0.80; p = 0.03; Figure 1a). A level below 15.5 ng/mL predicted the occurrence of acute kidney injury with a sensitivity of 78% and specificity of 56%. The VIS also predicted postoperative acute kidney injury (AUC, 0.61; 95% CI, 0.45–0.77; p = 0.048; Figure 1b). A value of VIS = 2 predicted the occurrence of acute kidney injury with a sensitivity of 61% and specificity of 56%.

Table 1

Comparison between 2 vitamin D groups: low levels < 20 ng/mL and normal levels > 20 ng/mL.

ParameterTotal25OHvitD ≤ 20 ng/mL25OHvitD > 20 ng/mLp-Value
Age, years, median (IQR)66 (61–71)66.5 (61.7–69.2)65 (60.5–71.5)0.536
BMI, median (IQR)28.4 (25.2–31.6)28.7 (25.6–30.4)29.0 (25.0–31.7)0.634
CPB time (min), median (IQR)101 (68.5–124)102 (73–125)100 (67–125)0.968
Clamping time (min), median (IQR)74 (45–93)69 (49.5–83.2)77 (39.5–96)0.569
VIS median (IQR)1.3 (0–3.5)0 (0–2.5)2.0 (0–4.0) 0.04
Mechanical ventilation time5.0 (3.0–8.0)5.0 (3.0–8.2)5.0 (3.0–8.0)0.563
Hospitalization duration (days)9.0 (8.0–12.0)10.0 (8.0–12.0)9.0 (8.0–12.0)0.421
Intensive care unit stay (days)3.0 (2.0–4.0)3.0 (2.0–4.0)3.0 (2.0–4.0)0.808

IQR = interquartile range; CPB = cardiopulmonary bypass time; VIS = vasoactive–inotropic score. Red color and bold means significant p value < 0.05

Table 2

Comparison between 2 VIS groups: low score < 15 and high score > 15.

ParameterTotalVIS < 15VIS ≥ 15p-Value
Age, years, median (IQR)66 (61–71)66.5 (61.7–69.2)65 (60.5–71.5)0.395
BMI, median (IQR)28.4 (25.2–31.6)28.7 (25.6–30.4)29.0 (25.0–31.7)0.942
CPB time (min), median (IQR)101 (68.5–124)102 (73–125)100 (67–125)0.456
Clamping time (min), median (IQR)74 (45–93)69 (49.5–83.2)77 (39.5–96)0.372
Mechanical ventilation time5.0 (3.0–8.0)5.0 (3.0–8.2)5.0 (3.0–8.0)0.735
Hospitalization duration (days)9.0 (8.0–12.0)9.0 (8.0–12.0)10.0 (8.0–12.0) 0.049
Intensive care unit stay (days)3.0 (2.0–4.0)1.5 (1.0–2.0)3.0 (2.0–4.0) 0.04

IQR = interquartile range; CPB = cardiopulmonary bypass time; VIS = vasoactive–inotropic score. Red color means significant p value < 0.05

Source: 3. Results Source: 3. Results Source: 3. Results Source: 3. Results Source: 3. Results Source: 3. Results Source: 3. Results Source: 3. Results Source: 3. Results Source: 3. Results Source: 3. Results Source: 3. Results Source: 3. Results

Conclusions

The vasoactive–inotropic score was shown to be associated with preoperative vitamin D levels. Patients with vitamin D levels below 20 ng/mL had greater postoperative VISs compared to patients with levels over 20 ng/mL. A VIS above 15 was linked to an extended duration of hospitalization and a prolonged stay in the ICU. A significant correlation was seen between the VIS and the duration of hospitalization, the days of stay in the intensive care unit, and the duration of mechanical ventilation.

Both vitamin D levels and the VIS were predictive of postoperative acute kidney injury.

Source: 5. Conclusions
Authors’ abstract

Background: The vasoactive–inotropic score (VIS) predicts unfavorable outcomes after cardiac surgery in both children and adults. In our adult population, we investigated whether preoperative levels of vitamin D can predict the VIS and whether both vitamin D and the VIS can predict adverse outcomes following major heart surgery. Methods: Between 1 October 2021 and 28 February 2022, 300 patients underwent major cardiac surgery at our institution. Eighty-three of them had their 25-OH vitamin D levels measured before surgery. For this cohort, we calculated the VIS based on doses of vasoactive and inotropic medications administered post-surgery.

Utilizing receiver operating curves, the predictive accuracy of vitamin D levels and the VIS in predicting acute kidney injury was assessed. Results: The median age of the cohort was 66 (IQR 61–71) years, with 59% being male and a median BMI of 28.4 (IQR 25.2–31.6). The most common procedures were aortic valve replacement, mitral valve replacement, coronary artery bypass grafting, aortic valve and ascending aorta repair, and ASD correction. There was a significant difference in the postoperative VIS between patients with vitamin D deficiency, i.e., <20 ng/mL, and patients with vitamin D values > 20 ng/mL (3.5 vs. 1.3 p < 0.04).

We also found a significant correlation between the VIS and the days of hospitalization (r = 0.335; p = 0.002), the days of stay in the intensive care unit (r = 0.547; p < 0.00001), and the mechanical ventilation time (r = 0.327; p = 0.025). Both vitamin D levels and the VIS predicted postoperative acute kidney injury (p < 0.05). Conclusions: Vitamin D deficiency is correlated with the VIS in adults undergoing major cardiac surgery. Both vitamin D levels and the VIS can predict unfavorable postoperative outcomes.

Read the full paper

1. Introduction

Unfavorable outcomes after major surgery can be predicted using scoring systems [1]. Nevertheless, EuroScore II, STS risk score, and Parsonnet score were specifically designed to predict the prognosis following cardiac surgery by considering preoperative factors rather than postoperative data [2,3,4]. The vasoactive–inotropic score (VIS) is determined by quantifying the combined effects of inotropes and vasoconstrictors for maintaining hemodynamic balance. A greater score indicates a more significant hemodynamic impairment. Gaies et al. [5], Wernovski et al. [6], and Favia et al. [7] established the validity of the VIS in predicting adverse outcomes in pediatric populations requiring heart surgery.

Previously conducted studies suggest that vitamin D is involved in vascular and cardiac function [8] and reduces the risk of arrhythmia [9]. A recent study showed no significant difference in the vitamin D supplementation group in terms of ICU stay, hospital stay, or duration of mechanical ventilation [10]. Nevertheless, a recent systematic review revealed contradictory findings concerning the overall survival and duration of stay in the intensive care unit (ICU) associated with vitamin D levels [11].

In our study, we investigated whether vitamin D levels and the VIS could predict unfavorable outcomes after major cardiac surgery in adult patients.

2. Materials and Methods

The present study was structured as a retrospective, single-arm, observational investigation conducted at a single cardiac surgery center and approved by the “Iuliu Hatieganu” University of Medicine Ethics Committee (approval number 259 on 28 September 2023). All patients who underwent major heart surgery (aortic or mitral valve procedures, coronary artery bypass, aortic valve and ascending aorta repair, aortic aneurysm repair, or association between CABG and other valve procedures) from 1 October 2021 to 28 February 2022 were selected for inclusion in the study, which specifically focused on patients who underwent preoperative evaluations of 25-OH vitamin D levels: The research was conducted in accordance with the principles of the Declaration of Helsinki and Good Clinical Practice Guidelines.

The requirement to obtain patient consent was waived because the data analysis was retrospective.

The exclusion criteria included age <18 years, emergency need for surgery, patients with hemodynamic instability referred for major cardiovascular surgery, patients who had catheter-based transfemoral aortic valve replacement, aortic arch intervention, or descending aortic surgery, patients that took vitamin D supplements prior to surgery, and patients with a hospital length of stay less than 24 h (transferred to other cardiac facilities). After heart surgery, all patients were monitored in the ICU. The administration of inotropic drugs such as dobutamine, dopamine, epinephrine, norepinephrine, milrinone, and vasopressin was started in the case of reduced cardiac output associated with hypotension.

Pharmacological responses to vasoactive and inotropic drugs were monitored, and the administration of these drugs was adjusted to the minimum necessary dosage rates to sustain sufficient cardiac output and blood pressure. The early postoperative use of vasoactive drugs can prevent multi-organ ischemia and dysfunction, and infusion was rapidly terminated or the rate decreased once the patient achieved circulatory stability. Vitamin D levels were correlated with VIS, cardiopulmonary bypass perfusion time, cross-clamp time, mechanical ventilation time, length of stay in the ICU, total length of stay in the hospital, and duration of mechanical ventilation.

The patients were registered in a single database, consisting of demographic, clinical, and postoperative information extracted from our internal hospital database. The data were transferred to an Excel spreadsheet and then to an SPSS file. All measurements for 25 OH vitamin D were conducted from venous blood using the Biotek Microplate 50 TS washer (Agilent Technologies Inc., Santa Clara, CA, USA) and the 800 TS reader (Agilent Technologies Inc., Santa Clara, CA, USA). Vitamin D deficiency was defined as a 25(OH)D3 level of <20 ng/mL; vitamin D insufficiency was defined as a 25(OH)D3 level of 20–30 ng/mL; and normal vitamin D levels were defined as a 25(OH)D3 level of at least 30 ng/mL.

Postoperative hemorrhage, renal dysfunction following surgical intervention, food restrictions, and fluid infusions are known to alter the postoperative status of vitamin D. Therefore, our analysis exclusively considered preoperative vitamin D levels to assess whether they could serve as a predictor of the patient’s postoperative outcome.

For calculating the VIS, the patient’s medical record was reviewed to determine the administration rate of vasoactive medications and inotropes. The cutoff for a high and low VIS was a score of 15 points [12].

Statistical Methods

Categorical variables were expressed as counts and proportions, while continuous variables were reported using the median together with ± the interquartile range. When suitable, correlations were conducted using Pearson or Spearman methodologies. Where suitable, Student’s T test or the Mann–Whitney U test were used to compare continuous variables. A comparison of categorical variables was conducted using the chi-square test. Outcomes following surgery were predicted using receiver operator curves (ROCs), which were also used to ascertain the specificity, sensitivity, and cutoff values of vitamin D and VIS for predicting unfavorable outcomes.

All analyses were conducted using SPSS version 23.0 (IBM SPSS Inc., Chicago, IL, USA). Statistical significance was defined as p-values less than 0.05.

3. Results

Between 1 October 2021 and 28 February 2022, 300 patients underwent major cardiac intervention at our institution: aortic or mitral valve procedures, coronary artery bypass, aortic valve and ascending aorta repair, aortic aneurysm repair, or association between CABG and other valve procedures. Eighty-three of them had a 25-OH vitamin D measurement taken before surgery and were included in this study. The median age was 66 years (range 38–81); the median value of 25-OH vitamin D was 16.0 ng/mL (IQR 15.0–19.0); and the plasma level was below 20 ng/mL in 65 patients (78.3%) and >20 ng/mL in 18 patients (21.7%).

No significant difference in sex (p = 0.536), age (p = 0.512), BMI (p = 0.634), days of hospitalization (p = 0.808), days of hospitalization in the ICU (p = 0.421), duration of mechanical ventilation (0.563), CPB time (p = 0.968), or clamping time (p = 0.569) was found between the two vitamin D groups. However, after excluding one outlier patient that had 44 days of hospitalization, the statistical analysis yielded a p-value of 0.77 for the difference in hospitalization days between the two vitamin D groups and a p-value of 0.042 for the difference in ICU stay.

However, there was a significant difference in the postoperative VIS between patients with vitamin D deficit values < 20 ng/zl and patients with normal vitamin D values > 20 ng/mL (3.5 vs. 1.3; p < 0.04) (Table 1). The vasopressors and inotropes used were dopamine in 6 patients (mean dose: 2.7 ± 0.7 mcg/kg/min), dobutamine in 27 patients (mean dose: 3.0 ± 1.8 mcg/kg/min), epinephrine in 3 patients (mean dose: 0.04 ± 0.02 mcg/kg/min), and norepinephrine in 26 patients (mean dose: 0.05 ± 0.09 mcg/kg/min).

To obtain the vasoactive–inotropic score (VIS), the weighted sum of all prescribed inotropes and vasoconstrictors was computed using the following formula:

VIS = dopamine (µg/kg/min) + dobutamine (µg/kg/min) + 100 × epinephrine (µg/kg/min) + 100 × norepinephrine (µg/kg/min) + 10 × milrinone (µg/kg/min) + 10,000 × vasopressin (units/kg/min) + 50 × levosimendan (µg/kg/min) [13]. The cutoff for a high and low VIS was a score of 15 points; therefore, we divided our cohort into two groups based on VIS < 15 or ≥15. There was no significant difference in age (p = 0.395), sex (p = 0.511), BMI (p = 0.942), CPB time (p = 0.456), clamping time (p = 0.372), or mechanical ventilation time (p = 0.735) between the two VIS groups according to the 15-point cutoff.

However, patients with a VIS >15 had a prolonged stay in the hospital (16 ± 1.4 vs. 10 ± 4.9 days) and in the ICU (11 ± 8.4 vs. 3.7 ± 4.9 days) compared to patients with a VIS < 15 (p < 0.05) (Table 2).

We also found a significant correlation between the VIS and days of hospitalization (r = 0.335; p = 0.002), days of stay in the ICU (r = 0.547; p < 0.00001), and mechanical ventilation time (r = 0.327; p = 0.025).

The univariate regression analysis indicated that there was an association between age [OR 1.1; 95% CI 1.02–1.2; p = 0.013], VIS [OR 1.4; 95% CI 1.005–1.937; p = 0.04], CPB time [OR 1.015; 95% CI 1.003–1.03; p = 0.018], clamping time [OR 1.022; 95% CI 1.005–1.04; p = 0.01], and a longer ICU stay.

Variables found to be significantly associated with ICU stay in the univariate analysis (p < 0.05) were included in the multivariate regression analysis, which showed an association only between VIS and ICU stay. Patients with a high VIS had significantly greater odds of having a longer ICU stay [OR 1.4; 95% confidence interval (CI) 1.1–1.7; p = 0.005].

We considered two groups based on major surgery: low complexity (single aortic or mitral valve procedures, coronary artery bypass) and high complexity (aortic valve + ascending aorta repair, aortic aneurysm repair, association between CABG + valve procedures, multiple-valve procedures).

We compared the two groups, low complexity vs. high complexity, and found significant differences in terms of VIS (2.9 vs. 6.5; p = 0.01), duration of mechanical ventilation (5.7 vs. 8.2 h; p = 0.04), ICU stay (3.4 vs. 5.9 days; p = 0.04), days of hospitalization (10.2 vs. 12.5; p = 0.05), CPB time (83 vs. 147 min; p = 0.001), and clamping time (63 vs. 120 min; p = 0.0001).

We compared patients with vitamin D deficit values < 20 ng/zl and patients with normal vitamin D values > 20. In the high-complexity group, we found a significant difference in postoperative VIS (6.2 vs. 8.0; p = 0.04), mechanical ventilation time (9.2 vs. 3.6 h; p = 0.004), ICU stay (6.5 vs. 3.0; p = 0.421), days of hospitalization (12.8 vs. 11 p = 0.03), CPB time (156 vs. 105 min; p = 0.01), and clamping time (128 vs. 79; p = 0.01).

However, there was no significant difference in the low-complexity group (p > 0.60 for all tests).

Using receiver operating curves (ROCs), we found that vitamin D levels predicted postoperative acute kidney injury (AUC, 0.662; 95% CI, 0.52–0.80; p = 0.03; Figure 1a). A level below 15.5 ng/mL predicted the occurrence of acute kidney injury with a sensitivity of 78% and specificity of 56%. The VIS also predicted postoperative acute kidney injury (AUC, 0.61; 95% CI, 0.45–0.77; p = 0.048; Figure 1b). A value of VIS = 2 predicted the occurrence of acute kidney injury with a sensitivity of 61% and specificity of 56%.

4. Discussion

The main finding of this retrospective cohort study was that both vitamin D levels and the VIS were significant predictors of unfavorable outcomes following major heart surgery in a sample of selected adults. Patients with a VIS > 15 had a prolonged stay in the hospital (16 vs. 10 days) and in the ICU (11 vs. 3.7 days) compared to those with a VIS < 15. Previous research supports the prognostic value of a VIS > 15. Gaies et al. [11] calculated the optimal cutoff value for the vasoactive–inotropic score to predict morbidity and mortality in infants after cardiopulmonary bypass.

According to the authors, moderate cardiovascular support on admission to the ICU after congenital heart surgery typically includes vasoactive infusions at dosages that result in a VIS of approximately 15. Based on this value, they considered a high VIS to be above 15 and a low VIS to be below 15. In a study by Sanil et al. [12] on children undergoing a heart transplant, 51 patients were divided into two groups based on the VIS: high VIS ≥ 15 and low VIS < 15.

A high VIS > 15 was independently associated with increased short-term morbidity after pediatric heart transplant. In a study by Perez-Navaro et al. [13], a VIS > 15.5 had a high specificity (92.87%; 95% CI: 86.75–98.96) and increased negative predictive value (75.59%, 95% CI: 71.1–88.08) for low cardiac output syndrome after congenital heart disease surgery. This value was an independent predictor of unfavorable outcomes, and the predictive value was not increased if cardiac biomarkers were added to the VIS.

Adults experiencing vitamin D deficiency typically require more vasoactive/inotropic support during extended hospitalizations. Prior research has demonstrated that the VIS provides good predictive accuracy and discriminatory capacity for infant and pediatric patients following cardiac surgery [11,12,13,14,15]. Sanil and Aggarwal [12] assessed the VIS following 51 consecutive open-heart transplant procedures. Patients with a VIS > 15 exhibited significantly prolonged ICU stays, increased inotropic requirements, extended ventilatory durations, and a higher incidence of short-term morbidities.

Gaies et al. [11] conducted a study including 391 newborns and concluded that a high VIS greater than 15 was substantially correlated with 30-day mortality, longer duration of mechanical respiration, and longer length of ICU stay. Davidson et al. [16] showed that an elevated VIS after cardiothoracic surgery was significantly correlated with extended mechanical ventilation duration, prolonged stays in intensive care units, and increased total hospital stay in neonates and infants. Our research on adults reveals similar results to those of the previously described studies conducted on children.

Koponen et al. [17] also showed that the VIS demonstrates comparable predictive accuracy and discriminatory abilities in an adult population as in children. The causal association between elevated doses of vasoactive–inotropes and adverse outcomes is difficult to ascertain clearly. Elevated dosages of vasoactive drugs may only reflect cardiovascular morbidity rather than direct worsening of the clinical state of the patient.

Our investigation found no statistically significant association between VIS and mortality. The findings of our study align with a recent meta-analysis that found no association between inotropes and increased mortality in the general population [18].

Our research identified the VIS as a promising tool for the prediction of acute kidney injury. The VIS showed good predictive value for acute kidney injury, with an AUC of 0.61, a sensitivity of 61%, and a specificity of 56% for a cutoff value of 2. One possible strategy would be to decrease the dosage of inotropic and vasoactive drugs to a level that enables adequate tissue perfusion without risking adverse effects on renal perfusion. On the contrary, it is crucial to promptly address factors that may elevate the VIS, such as an infection that may result in infectious shock requiring vasoactive medications or an untreated coronary lesion that may lead to myocardial necrosis, reducing the ejection fraction to cardiogenic shock requiring inotropes [19].

Vitamin D deficiency is defined as a 25(OH) vit D level below 20 ng/mL and vitamin D insufficiency as a level of 21–29 ng/mL. In our cohort, patients with vitamin D deficiency had a higher VIS compared to patients with levels > 20 ng/mL (3.5 vs. 1.3). Our findings are consistent with those of Ye et al. [20], who demonstrated that vitamin D deficiency was linked to an increased need for inotropic support in children who underwent cardiac surgery for congenital heart disease.

Their study revealed that 33% of children with vitamin D levels < 20 ng/mL had a VIS above 15, and 22.8% of children with vitamin D levels of >20 ng/mL had a VIS greater than 15 (p = 0.000). To the best of our knowledge, our study is the first to demonstrate an association between vitamin D deficiency and VIS in adult patients requiring major heart surgery.

Ye et al. [11] also showed that children with vitamin D levels < 20 ng/mL have longer CBP times (67 min) and clamping times (37 min) compared to children with vitamin D levels > 20 ng/mL (52 min for CBP time and 29 min for clamping time). However, in our cohort of adults, we found no difference in CBP time and clamping time between patients with levels < 20 ng/mL and patients with levels > 20 ng/mL.

We also found a significant correlation between VIS and duration of mechanical ventilation. Despite significant advancements in perioperative care for cardiac surgery, the prevalence of extended mechanical ventilation in postoperative patients remains as high as 22% [21]. Low levels of vitamin D, <20 ng/mL, were demonstrated to be linked to prolonged mechanical ventilation and extended hospital and intensive care unit stays in children hospitalized in an ICU [22,23,24]. De Pascale et al. [25] demonstrated that critically ill septic patients with extremely low vitamin D levels, <7 ng/mL, at ICU admission may experience adverse outcomes, including increased mortality and elevated infection rates.

Deficiency in vitamin D has been associated with worse outcomes in patients hospitalized in the ICU and negative outcomes for infectious diseases [26].

Vitamin D is crucial for the control of the immune system as it decreases the inflammatory response, increasing phagocytosis, and stimulates lymphocyte proliferation. Vitamin D deficiency inhibits B cell proliferation and differentiation, prevents immunoglobulin release by B cells, and inhibits T cell proliferation [27]. Vitamin D deficiency leads to diminished production of inflammatory cytokines, including IL-1, IL-6, IL-12, IL-21, and TNF-α, while enhancing the production of anti-inflammatory cytokines, such as IL-10 [28,29]. Vitamin D acts by improving the absorption of calcium and phosphorus in the intestinal tract, promoting the mobilization of calcium from bones, and augmenting the renal reabsorption of calcium in the distal tubules [30].

Vitamin D exerts its influence on cardiac contractility via the vitamin D receptor (VDR) located on myocardial cells, interacting at the molecular level to modify myocardial contractility in both healthy and diseased hearts [31]. Cellular vitamin D receptors are present in all cardiac cells, and low vitamin D levels may directly affect atrial and ventricular cardiac myocytes. Therefore, vitamin D supplementation might improve outcomes after major cardiac surgery and decrease the use of inotropic and vasoactive agents. Whether the supplementation of vitamin D after cardiac surgery can improve outcomes and lower hospital and ICU stays remains controversial [32], and extensive prospective trials on the effectiveness of vitamin D supplementation are required.

Our findings suggest, as therapeutic implications, that preoperative vitamin D administration may elevate serum 25OH vitamin D levels and prevent unfavorable outcomes, such as prolonged mechanical ventilation, extended ICU stay, prolonged hospitalization, and acute kidney injury. This can be accomplished through the oral administration of a high dose of vitamin D, as demonstrated in a study by Leszczyńska et al. [33], which utilized a single dose of 120,000 IU of vitamin D3, leading to an increase in levels to 20–50 ng/mL.

An intravenous bolus dose of 50,000–100,000 U, as demonstrated in research by Barker et al. [34], Armas et al. [35], Ilahi et al. [36], or Heaney et al. [37], may be more efficient in quickly increasing vitamin D levels in patients who need an immediate elevation in serum vitamin D levels before major cardiac surgery.

Limitations

This study is limited by its observational nature, which, despite multivariable adjustments for multiple potential confounders, predisposes it to residual and unobserved confounding. Its observational nature also precluded the establishment of causality. Additionally, the relatively low event rates for some of the outcomes reduced the reliability of our findings, which cannot be applied broadly because of the limited sample size (n = 83). We believe that an increased patient population in a multicenter study would have yielded a more rigorous statistical result.

Another important limitation of this study was its single-center design, which may introduce biases related to certain surgical techniques or patient demographics. For different cardiac surgery units that may have variations in terms of vasoactive and inotropic drug treatment regimens and the availability of mechanical cardiovascular support devices, adjustment of the VIS cutoff may be necessary. Further, larger prospective studies addressing the above issues are warranted to offer more proof of the link between vitamin D levels and surgical outcomes.

5. Conclusions

The vasoactive–inotropic score was shown to be associated with preoperative vitamin D levels. Patients with vitamin D levels below 20 ng/mL had greater postoperative VISs compared to patients with levels over 20 ng/mL. A VIS above 15 was linked to an extended duration of hospitalization and a prolonged stay in the ICU. A significant correlation was seen between the VIS and the duration of hospitalization, the days of stay in the intensive care unit, and the duration of mechanical ventilation.

Both vitamin D levels and the VIS were predictive of postoperative acute kidney injury.

Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Author Contributions

Conceptualization, A.S., C.B. and G.C.; methodology, A.S., A.G.S. and N.T.; software, A.S. and G.C.; validation, A.S., C.B. and S.S.C., M.M., A.G.S., N.T., R.O.M. and G.C.; formal analysis, A.S. and G.C.; investigation, A.S., A.G.S. and N.T.; resources, A.S., A.G.S. and N.T.; data curation, A.S., C.B., S.S.C., M.M., A.G.S., N.T., R.O.M. and G.C.; writing—original draft preparation, A.S. and G.C.; writing—review and editing, C.B., S.S.C., M.M., A.G.S., N.T. and R.O.M.; visualization, A.S., C.B., S.S.C., M.M., A.G.S., N.T., R.O.M. and G.C.; supervision, A.S. and C.B.; project administration, A.S.; funding acquisition, A.S.

All authors have read and agreed to the published version of the manuscript.

Institutional Review Board Statement

The study was conducted in accordance with the Declaration of Helsinki and approved by the Ethics Committee of the “Iuliu Hatieganu” University of Medicine Cluj-Napoca, Romania (approval number 259 on 28 September 2023).

Informed Consent Statement

Informed consent statement: Informed consent was waived because of the retrospective nature of the study, and the analysis used anonymous clinical data.

Data Availability Statement

Data supporting the reported results can be found in Mega cloud through the following link: https://mega.nz/fm/yYwzSS6a (accessed on 19 September 2024).

Conflicts of Interest

The authors declare no conflicts of interest.

References

1. Doerr F. Badreldin A. Heldwein M.B. A comparative study of four intensive care outcome prediction models in cardiac surgery patients J. Cardiothorac. Surg. 2011 6 21 10.1186/1749-8090-6-21 21362175 PMC3058022
2. Martinez J. Tuesta I.D. Plasencia E. Santana M. Mora M.L. Mortality prediction in cardiac surgery patients: Comparative performance of Parsonnet and general severity systems Circulation 1999 99 2378 2382 10.1161/01.CIR.99.18.2378 10318657
3. Nashef S.A.M. Roques F. Sharples L.D. EuroSCORE II Eur. J. Cardiothorac. Surg. 2012 41 734 744 10.1093/ejcts/ezs043 22378855
4. D’Agostino R.S. Jacobs J.P. Badhwar V. The society of thoracic surgeons adult cardiac surgery database: 2017 update on outcomes and quality Ann. Thorac. Surg. 2017 103 18 24 10.1016/j.athoracsur.2016.11.001 27884412
5. Gaies M.G. Gurney J.G. Yen A.H. Vasoactive-inotropic score as a predictor of morbidity and mortality in infants after cardiopulmonary bypass Pediatr. Crit. Care Med. 2010 11 234 238 10.1097/PCC.0b013e3181b806fc 19794327
6. Wernovsky G. Wypij D. Jonas R.A. Postoperative course and hemodynamic profile after the arterial switch operation in neonates and infants. A comparison of low-flow cardiopulmonary bypass and circulatory arrest Circulation 1995 92 2226 2235 10.1161/01.CIR.92.8.2226 7554206
7. Favia I. Vitale V. Ricci Z. The vasoactive-inotropic score and levosimendan: Time for VIS? J. Cardiothorac. Vasc. Anesth. 2013 27 15 16 10.1053/j.jvca.2012.11.009 23507021
8. Haider F. Ghafoor H. Hassan O.F. Farooqui K. Bel Khair A.O.M. Shoaib F. Vitamin D and Cardiovascular Diseases: An Update Cureus 2023 15 e49734 10.7759/cureus.49734 38161941 PMC10757591
9. Barsan M. Brata A.M. Ismaiel A. Dumitrascu D.I. Badulescu A.V. Duse T.A. Dascalescu S. Popa S.L. Grad S. Muresan L. The Pathogenesis of Cardiac Arrhythmias in Vitamin D Deficiency Biomedicines 2022 10 1239 10.3390/biomedicines10061239 35740261 PMC9220304
10. Lan S.H. Lai C.C. Chang S.P. Lu L.C. Hung S.H. Lin W.T. Vitamin D supplementation and the outcomes of critically ill adult patients: A systematic review and meta-analysis of randomized controlled trials Sci. Rep. 2020 10 14261 10.1038/s41598-020-71271-9 32868842 PMC7459294
11. Gaies M.G. Jeffries H.E. Niebler R.A. Pasquali S.K. Donohue J.E. Yu S. Gall C. Rice T.B. Thiagarajan R.R. Vasoactive-inotropic score is associated with outcome after infant cardiac surgery: An analysis from the pediatric cardiac critical care consortium and virtual pICU system registries Pediatr. Crit. Care Med. 2014 15 529 537 10.1097/PCC.0000000000000153 24777300 PMC4159673
12. Ott S. Lewin D. Nersesian G. Stein J. Just I.A. Hommel M. Schoenrath F. Starck C.T. O’Brien B. Falk V. Improving Survival in Cardiogenic Shock—A Propensity Score-Matched Analysis of the Impact of an Institutional Allocation Protocol to Short-Term Mechanical Circulatory Support Life 2022 12 1931 10.3390/life12111931 36431066 PMC9692664
13. Pérez-Navero J.L. Merino-Cejas C. Ibarra de la Rosa I. Jaraba-Caballero S. Frias-Perez M. Gómez-Guzmán E. Gil-Campos M. de la Torre-Aguilar M.J. Evaluation of the vasoactive-inotropic score, mid-regional pro-adrenomedullin and cardiac troponin I as predictors of low cardiac output syndrome in children after congenital heart disease surgery Med. Intensiv. (Engl. Ed.) 2019 43 329 336 10.1016/j.medin.2018.04.005 29910113
14. Song J. Cho H. Park D.W. Moon S. Kim J.Y. Ahn S. Lee S.-G. Park J. Vasoactive-Inotropic Score as an Early Predictor of Mortality in Adult Patients with Sepsis J. Clin. Med. 2021 10 495 10.3390/jcm10030495 33572578 PMC7867010
15. Sanil Y. Aggarwal S. Vasoactive-inotropic score after pediatric heart transplant: A marker of adverse outcome Pediatr. Transplant. 2013 17 567 572 10.1111/petr.12112 23773439
16. Davidson J. Tong S. Hancock H. Hauck A. da Cruz E. Kaufman J. Prospective validation of the vasoactive-inotropic score and correlation to short-term outcomes in neonates and infants after cardiothoracic surgery Intensive Care Med. 2012 38 1184 1190 10.1007/s00134-012-2544-x 22527067 PMC4984395
17. Garcia R.U. Walters H.L. Delius R.E. Aggarwal S. Vasoactive inotropic score (VIS) as biomarker of short-term outcomes in adolescents after cardiothoracic surgery Pediatr. Cardiol. 2016 37 271 277 10.1007/s00246-015-1273-7 26424215
18. Koponen T. Karttunen J. Musialowicz T. Pietiläinen L. Uusaro A. Lahtinen P. Vasoactive-inotropic score and the prediction of morbidity and mortality after cardiac surgery Br. J. Anaesth. 2019 122 428 436 10.1016/j.bja.2018.12.019 30857599 PMC6435836
19. Belletti A. Castro M.L. Silvetti S. The Effect of inotropes and vasopressors on mortality: A meta-analysis of randomized clinical trials Br. J. Anaesth. 2015 115 656 675 10.1093/bja/aev284 26475799
20. Belletti A. Lerose C.C. Zangrillo A. Landoni G. Vasoactive-inotropic score: Evolution, clinical utility, and pitfalls J. Cardiothorac. Vasc. Anesth. 2021 35 3067 3077 10.1053/j.jvca.2020.09.117 33069558
21. Sharma V. Rao V. Manlhiot C. Boruvka A. Fremes S. Wąsowicz M. A derived and validated score to predict prolonged mechanical ventilation in patients undergoing cardiac surgery J. Thorac. Cardiovasc. Surg. 2017 153 108 115 10.1016/j.jtcvs.2016.08.020 27665221
22. Ye X. Dong S. Deng Y. Jiang C. Kong Y. Tang L. Wang Y. Bei F. Hong H. Preoperative Vitamin D Deficiency Is Associated with Higher Vasoactive-Inotropic Scores Following Pediatric Cardiac Surgery in Chinese Children Front. Pediatr. 2021 9 671289 10.3389/fped.2021.671289 34395337 PMC8355366
23. Razavi Khorasani N.M.B. Zahedi Tajrishi F. Mohammadpour Z. Rouhi F. Alizadeh-Navaei R. Ghadimi R. The association between low levels of vitamin d and clinical outcomes in critically-Ill children: A Systematic review and meta-Analysis Fetal Pediatr. Pathol. 2020 39 503 517 10.1080/15513815.2019.1675832 31603014
24. McNally J.D. Nama N. O’Hearn K. Sampson M. Amrein K. Iliriani K. McIntyre L. Fergusson D. Menon K. Vitamin d deficiency in critically ill children: A systematic review and meta-analysis Crit. Care 2017 21 287 10.1186/s13054-017-1875-y 29169388 PMC5701429
25. De Pascale G. Vallecoccia M.S. Schiattarella A. Di Gravio V. Cutuli S.L. Bello G. Clinical and microbiological outcome in septic patients with extremely low 25-hydroxyvitamin D levels at initiation of critical care Clin. Microbiol. Infect. 2016 22 456.e7 456.e13 10.1016/j.cmi.2015.12.015 26721785
26. Moromizato T. Litonjua A.A. Braun A.B. Gibbons F.K. Giovannucci E. Christopher K.B. Association of low serum 25-hydroxyvitamin D levels and sepsis in the critically ill Crit. Care Med. 2014 42 97 107 10.1097/CCM.0b013e31829eb7af 23982028
27. Széles L. Keresztes G. Töröcsik D. Balajthy Z. Krenács L. Póliska S. 1,25-dihydroxyvitamin D3 is an autonomous regulator of the transcriptional changes leading to a tolerogenic dendritic cell phenotype J. Immunol. 2009 182 2074 2083 10.4049/jimmunol.0803345 19201860
28. Almerighi C. Sinistro A. Cavazza A. Ciaprini C. Rocchi G. Bergamini A. 1Alpha,25-dihydroxyvitamin D3 inhibits CD40L-induced pro-inflammatory and immunomodulatory activity in human monocytes Cytokine 2009 45 190 197 10.1016/j.cyto.2008.12.009 19186073
29. Yang B. Zhu Y. Zheng X. Li T. Niu K. Wang Z. Lu X. Zhang Y. Shen C. Vitamin D Supplementation during Intensive Care Unit Stay Is Associated with Improved Outcomes in Critically Ill Patients with Sepsis: A Cohort Study Nutrients 2023 15 2924 10.3390/nu15132924 37447250 PMC10346786
30. DeLuca H.F. The metabolism and functions of vitamin D Adv. Exp. Med. Biol. 1986 196 361 375 3012979 10.1007/978-1-4684-5101-6_24
31. Polly P. Tan T.C. The role of vitamin D in skeletal and cardiac muscle function Front. Physiol. 2014 5 145 10.3389/fphys.2014.00145 24782788 PMC3995052
32. Dao D.T. Anez-Bustillos L. Cho B.S. Li Z. Puder M. Gura K.M. Assessment of micronutrient status in critically ill children: Challenges and opportunities Nutrients 2017 9 1185 10.3390/nu9111185 29143766 PMC5707657
33. Leszczyńska D. Szatko A. Kowalski K. Raczkiewicz D. Ostrowska M. Misiorowski W. Zgliczyński W. Glinicki P. The Effect of a Single High Dose of Vitamin D on Serum Levels of Its Metabolites in the Elderly Front. Biosci. 2022 27 289 10.31083/j.fbl2710289 36336861
34. Barker T. Brown K.B. Rogers V.E. Soluble TNF receptors are modulated by vitamin D status but not by acute perturbations in 25-hydroxyvitamin D following a bolus of supplemental vitamin D J. Cytokine Biol. 2017 2 118 10.4172/2576-3881.1000118
35. Armas L.A. Hollis B.W. Heaney R.P. Vitamin D2 is much less effective than vitamin D3 in humans J. Clin. Endocrinol. Metab. 2004 89 5387 5391 10.1210/jc.2004-0360 15531486
36. Ilahi M. Armas L.A. Heaney R.P. Pharmacokinetics of a single, large dose of cholecalciferol Am. J. Clin. Nutr. 2008 87 688 691 10.1093/ajcn/87.3.688 18326608
37. Heaney R.P. Armas L.A. Shary J.R. Bell N.H. Binkley N. Hollis B.W. 25-Hydroxylation of vitamin D3: Relation to circulating vitamin D3 under various input conditions Am. J. Clin. Nutr. 2008 87 1738 1742 10.1093/ajcn/87.6.1738 18541563
Figure 1

Receiver operator curves for vitamin D and VIS as predictors of postoperative acute kidney injury. (a) Vitamin D levels predict postoperative acute kidney injury—AUC: 0.662. A value of 15.5 ng/mL predicts development of renal failure with a sensitivity of 78% and specificity of 56%. (b) VIS predicts postoperative acute kidney injury—AUC: 0.61. A value of 2 ng/mL predicts development of acute kidney injury with a sensitivity of 61% and specificity of 56%.

Figure image at the original source — open the original paper. This file is not included in this text import.
Table 1

Comparison between 2 vitamin D groups: low levels < 20 ng/mL and normal levels > 20 ng/mL.

ParameterTotal25OHvitD ≤ 20 ng/mL25OHvitD > 20 ng/mLp-Value
Age, years, median (IQR)66 (61–71)66.5 (61.7–69.2)65 (60.5–71.5)0.536
BMI, median (IQR)28.4 (25.2–31.6)28.7 (25.6–30.4)29.0 (25.0–31.7)0.634
CPB time (min), median (IQR)101 (68.5–124)102 (73–125)100 (67–125)0.968
Clamping time (min), median (IQR)74 (45–93)69 (49.5–83.2)77 (39.5–96)0.569
VIS median (IQR)1.3 (0–3.5)0 (0–2.5)2.0 (0–4.0) 0.04
Mechanical ventilation time5.0 (3.0–8.0)5.0 (3.0–8.2)5.0 (3.0–8.0)0.563
Hospitalization duration (days)9.0 (8.0–12.0)10.0 (8.0–12.0)9.0 (8.0–12.0)0.421
Intensive care unit stay (days)3.0 (2.0–4.0)3.0 (2.0–4.0)3.0 (2.0–4.0)0.808

IQR = interquartile range; CPB = cardiopulmonary bypass time; VIS = vasoactive–inotropic score. Red color and bold means significant p value < 0.05

Table 2

Comparison between 2 VIS groups: low score < 15 and high score > 15.

ParameterTotalVIS < 15VIS ≥ 15p-Value
Age, years, median (IQR)66 (61–71)66.5 (61.7–69.2)65 (60.5–71.5)0.395
BMI, median (IQR)28.4 (25.2–31.6)28.7 (25.6–30.4)29.0 (25.0–31.7)0.942
CPB time (min), median (IQR)101 (68.5–124)102 (73–125)100 (67–125)0.456
Clamping time (min), median (IQR)74 (45–93)69 (49.5–83.2)77 (39.5–96)0.372
Mechanical ventilation time5.0 (3.0–8.0)5.0 (3.0–8.2)5.0 (3.0–8.0)0.735
Hospitalization duration (days)9.0 (8.0–12.0)9.0 (8.0–12.0)10.0 (8.0–12.0) 0.049
Intensive care unit stay (days)3.0 (2.0–4.0)1.5 (1.0–2.0)3.0 (2.0–4.0) 0.04

IQR = interquartile range; CPB = cardiopulmonary bypass time; VIS = vasoactive–inotropic score. Red color means significant p value < 0.05

Publication and source details

Original title: Lower Levels of Vitamin D Are Associated with Higher Vasoactive–Inotropic Scores in Major Cardiac Surgery

Adrian Stef; Constantin Bodolea; Simona Sorana Cainap; Monica Muntean; Aurelia Georgeta Solomonean; Nadina Tintiuc; Razvan Olimpiu Mada; Gabriel Cismaru

Life · 2024

* Correspondence: gabi_cismaru@yahoo.com; Tel.: +40-264207022© 2024 by the authors.2024https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).This research received no external funding.

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-11T00:43:10.666851+00:00

DOI: 10.3390/life14111349 · PMC11595299