Primary relevance to vitamin D Vitamin D is a stated subject of this paper.
Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.
Why this paper is included
Supporting source evidence:
Therefore, the proposed study aims to determine a clinically acceptable ML model for the detection of the vitamin D status of the North Cyprus adult participants accurately, without the need to determine 25-OH-D level, taking into account the multicollinearity problem.
Source: Abstract. View original paper
Relevance classification does not establish study quality, causation or editorial approval.
Study design Study design awaiting verification.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.
Meta-analysis unclear · Blinding unclear / not reported · Human research reported
How this paper was classified
Automatic source-based classification; awaiting editorial verification. This is not a quality score.
According to the 25-OH Vitamin D (VD) levels, participants were separated into three classes as the Deficient Vitamin D class (VD < 20 ng / mL), Inadequate Vitamin D class (20 ng/mL < = VD < 30 ng / mL), and Adequate Vitamin D class (VD > = 30 ng/mL).
Source: Methods.
What the study types mean
- Systematic review
- Uses explicit methods to identify, assess and summarise research on a defined question.
- Scoping review
- Maps the extent and characteristics of research on a topic.
- Narrative review
- Discusses existing research; systematic-review methods have not been established by this classification.
- Review / evidence synthesis
- Reviews existing research; the exact review methods need further assessment.
- Randomised controlled trial
- Assigns participants or groups to comparison interventions by chance.
- Non-randomised intervention study
- Examines an intervention without random allocation.
- Cohort study
- Examines exposures and outcomes over time within a defined group.
- Case-control study
- Compares people with an outcome against people without it, examining exposures.
- Cross-sectional study
- Examines a population at a particular point in time.
- Observational study
- Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
- Case report
- Describes an individual case.
- Case series
- Describes a group of individual cases.
- Secondary analysis
- Analyses existing study data; this paper is not automatically another independent trial.
- Laboratory study
- Investigates biological processes in a laboratory setting.
- Qualitative study
- Examines experiences or meanings using qualitative methods.
- Genetic instrumental-variable study
- Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
- Study protocol
- Describes planned methods and is not evidence that the planned study has reported results.
- Multiple reported designs
- More than one design is explicitly reported; examine the supporting methods.
- Study design awaiting verification
- The available source does not establish a sufficiently clear study design.
Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.
Abstracts
Machine learning approach for the detection of vitamin D level: a comparative study
Study design awaiting verification · BMC Medical Informatics and Decision Making · 2023
Original publication title
Machine learning approach for the detection of vitamin D level: a comparative study
© The Author(s) 2023
Original publication · Publisher record · CC BY 4.0 · CC0
Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.
At a glance
Abstract: What background does the paper provide?
After the World Health Organization declared the COVID-19 pandemic, the role of Vitamin D has become even more critical for people worldwide. The most accurate way to define vitamin D level is 25-hydroxy vitamin D(25-OH-D) blood test. However, this blood test is not always feasible. Most data sets used in health science research usually contain highly correlated features, which is referred to as multicollinearity problem. This problem can lead to misleading results and overfitting problems in the ML training process.
Therefore, the proposed study aims to determine a clinically acceptable ML model for the detection of the vitamin D status of the North Cyprus adult participants accurately, without the need to determine 25-OH-D level, taking into account the multicollinearity problem.
Source: BackgroundAbstract: What methods does the paper describe?
The study was conducted with 481 observations who applied voluntarily to Internal Medicine Department at NEU Hospital. The classification performance of four conventional supervised ML models, namely, Ordinal logistic regression(OLR), Elastic-net ordinal regression(ENOR), Support Vector Machine(SVM), and Random Forest (RF) was compared. The comparative analysis is performed regarding the model's sensitivity to the participant’s metabolic syndrome(MtS)'positive status, hyper-parameter tuning, sensitivities to the size of training data, and the classification performance of the models.
Source: MethodAbstract: Results
Due to the presence of multicollinearity, the findings showed that the performance of the SVM(RBF) is obviously negatively affected when the test is examined. Moreover, it can be obviously detected that RF is more robust than other models when the variations in the size of training data are examined. This experiment's result showed that the selected RF and ENOR showed better performances than the other two models when the size of training samples was reduced. Since the multicollinearity is more severe in the small samples, it can be concluded that RF and ENOR are not affected by the presence of the multicollinearity problem.
The comparative analysis revealed that the RF classifier performed better and was more robust than the other proposed models in terms of accuracy (0.94), specificity (0.96), sensitivity or recall (0.94), precision (0.95), F1-score (0.95), and Cohen's kappa (0.90).
Source: ResultsAbstract: Conclusion
It is evident that the RF achieved better than the SVM(RBF), ENOR, and OLR. These comparison findings will be applied to develop a Vitamin D level intelligent detection system for being used in routine clinical, biochemical tests, and lifestyle characteristics of individuals to decrease the cost and time of vitamin D level detection.
Source: ConclusionAuthors’ abstract
Background
After the World Health Organization declared the COVID-19 pandemic, the role of Vitamin D has become even more critical for people worldwide. The most accurate way to define vitamin D level is 25-hydroxy vitamin D(25-OH-D) blood test. However, this blood test is not always feasible. Most data sets used in health science research usually contain highly correlated features, which is referred to as multicollinearity problem. This problem can lead to misleading results and overfitting problems in the ML training process.
Therefore, the proposed study aims to determine a clinically acceptable ML model for the detection of the vitamin D status of the North Cyprus adult participants accurately, without the need to determine 25-OH-D level, taking into account the multicollinearity problem.
Method
The study was conducted with 481 observations who applied voluntarily to Internal Medicine Department at NEU Hospital. The classification performance of four conventional supervised ML models, namely, Ordinal logistic regression(OLR), Elastic-net ordinal regression(ENOR), Support Vector Machine(SVM), and Random Forest (RF) was compared. The comparative analysis is performed regarding the model's sensitivity to the participant’s metabolic syndrome(MtS)'positive status, hyper-parameter tuning, sensitivities to the size of training data, and the classification performance of the models.
Results
Due to the presence of multicollinearity, the findings showed that the performance of the SVM(RBF) is obviously negatively affected when the test is examined. Moreover, it can be obviously detected that RF is more robust than other models when the variations in the size of training data are examined. This experiment's result showed that the selected RF and ENOR showed better performances than the other two models when the size of training samples was reduced. Since the multicollinearity is more severe in the small samples, it can be concluded that RF and ENOR are not affected by the presence of the multicollinearity problem.
The comparative analysis revealed that the RF classifier performed better and was more robust than the other proposed models in terms of accuracy (0.94), specificity (0.96), sensitivity or recall (0.94), precision (0.95), F1-score (0.95), and Cohen's kappa (0.90).
Conclusion
It is evident that the RF achieved better than the SVM(RBF), ENOR, and OLR. These comparison findings will be applied to develop a Vitamin D level intelligent detection system for being used in routine clinical, biochemical tests, and lifestyle characteristics of individuals to decrease the cost and time of vitamin D level detection.
Publication and source details
Original title: Machine learning approach for the detection of vitamin D level: a comparative study
Nuriye Sancar; Sahar S. Tabrizi
BMC Medical Informatics and Decision Making · 2023
© The Author(s) 2023https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated in a credit line to the data.Repository JATS snapshot; version as supplied
Source retrieved: 2026-11-11T05:59:18.385230+00:00
DOI: 10.1186/s12911-023-02323-z · PMC10580577