Vitamin D3 for Life. Live Enlightened.

Research libraryVitamin D3 For Life
Study design and methods

Primary relevance to vitamin D Vitamin D is a stated subject of this paper.

Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.

Why this paper is included

Supporting source evidence:

Modalities of Vitamin D Administration to Preterm Infants: Impact on 25 OH Vitamin D Levels

Source: Article title. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Study design awaiting verification.

Study design awaiting verification

The available source does not establish a sufficiently clear study design.

Meta-analysis unclear · Blinding unclear / not reported · Research setting awaiting verification

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Full studies

Modalities of Vitamin D Administration to Preterm Infants: Impact on 25 OH Vitamin D Levels

Study design awaiting verification · Acta Paediatrica (Oslo, Norway : 1992) · 2025

Original publication title

Modalities of Vitamin D Administration to Preterm Infants: Impact on 25 OH Vitamin D Levels

Sophie Laborie; Manon Breniaux; Justine Bacchetta; Marine Butin

© 2025 The Author(s). Acta Paediatrica published by John Wiley & Sons Ltd on behalf of Foundation Acta Paediatrica.

Original publication · Publisher record · CC BY 4.0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

At a glance

Opening passage

Among preterm infants, low serum 25‐hydroxyvitamin D (25(OH)D) levels are associated with increased morbidities, including bronchopulmonary dysplasia, whereas excessive levels may lead to hypercalcemia, hypercalciuria, and nephrocalcinosis [1].

Authors’ abstract
Read the full paper

Abbreviations

25(OH)D

25‐hydroxyvitamin D

NICUs

Neonatal Intensive Care Units

1

Among preterm infants, low serum 25‐hydroxyvitamin D (25(OH)D) levels are associated with increased morbidities, including bronchopulmonary dysplasia, whereas excessive levels may lead to hypercalcemia, hypercalciuria, and nephrocalcinosis [1].

For vitamin D intakes, U.S. recommendations suggest 200–400 IU/day; European guidelines advise 400–700 IU/kg/day up to 1000 IU/day, monitoring is suggested. In France, 2022 guidelines recommend 600–1000 IU/day of enteral vitamin D for extremely and very preterm infants, with monthly monitoring of 25(OH)D and a target of 50–120 nmol/L [2].

Three enteral formulations are available in France: Uvesterol ADEC (Crinex, Gentilly, France): aqueous multivitamin with ergocalciferol, 1000 IU/0.3 mL, Adrigyl (Crinex, Gentilly, France): cholecalciferol, lipidic, 333 IU/drop, Zyma D (Viatris Santé, Lyon, France): cholecalciferol, lipidic, 300 IU/drop. Despite frequent NICU use of alfacalcidol or calcitriol, we found no published guidelines recommending them for preterm infants [3].

Vitamin D, being lipophilic, can sorb to plastics, with losses influenced by formulation, excipients, tubing materials, and administration technique [4]. We hypothesised that variability in 25(OH)D levels partly reflects differences in dosing practices and delivery methods.

A national survey was conducted in 2024 across 54 neonatal French neonatal intensive care units (NICUs). Data collected included parenteral and enteral supplementation practices, monitoring strategies, dose adjustments, incidence of deficiency or excess [2], and use of vitamin D analogs were recorded.

Results were descriptive. Fisher's exact test assessed associations between practices and abnormalities (p < 0.05).

Among the 54 centers, 41 (76%) responded: 24/41 (59%) routinely measured 25(OH)D levels, 19/41 (46%) adjusted native vitamin D doses, 30/41 (73%) used alfacalcidol, and only 1/41 (2%) used calcitriol.

Parenteral supplementation ranged from 33 to 500 IU/kg/day or 32–400 IU/day, with medians of 120 IU/kg/day and 110 IU/day.

Enteral supplementation practices varied: 10/41 NICUs (24%) used cholecalciferol, 31/41 (76%) used ergocalciferol, and doses were 1000 IU/day (24/41, 56%), 660 IU/day (6/41, 15%), 600 IU/day (5/41, 12%), or variable (6/41, 15%).

The relationship between enteral dosing, administration methods, and the occurrence of deficiency or excess is shown in Figure 1.

FIGURE 1

Report on deficiencies and/or excesses of 25(OH)D levels in NICUs, based on the dose and administration method of native vitamin D.

Figure image at the original source — open the original paper. This file is not included in this text import.

Vitamin D excess occurred in 3 NICUs despite low total parenteral (44–55 IU/day) and enteral (600–660 IU/day) intakes. One NICU using 160 IU/kg/day parenteral followed by 1000 IU/day of enteral cholecalciferol reported both deficiency and excess.

NICUs using 600–660 IU/day reported more frequent deficiencies than those giving 1000 IU/day (7/8 vs. 4/10; p = 0.053).

NICUs administering undiluted formulations containing ergocalciferol at 1000 IU/day had significantly fewer deficiencies than those using diluted formulations (0/5 vs. 3/4; p = 0.048).

Among the NICUs using alfacalcidol, 5/30 (17%) used it more than once a month. Indications included severe hypocalcemia (29/30, 97%), metabolic bone disease (7/30, 23%), and kidney failure (1/30, 3%). Treated infants were extremely (10/30, 30%), very (15/30, 50%), and moderately preterm infants (25/30, 83%). The dosages ranged from 0.1 μg/day to 2 μg/kg/day. The pre‐treatment labs included calcium and phosphate (29/30, 97%), PTH (15/30, 50%), 25(OH)D (14/30, 47%), ALP (10/30, 33%), and 1,25(OH)₂D (6/30, 20%). Treatment was mostly short (< 10 days in 90% (27/30)); it never exceeded 1 month.

Dose adjustments were mainly based on circulating calcium (25/30.83%).

Parenteral vitamin D doses were often below recommendations due to the use of multivitamin preparations formulated for older children with low vitamin D content.

Despite low parenteral doses, some NICUs reported excess, possibly due to high enteral supplementation or maternal prenatal vitamin D intake (100 000 IU recommended during the seventh month).

On the other hand, a NICU using high‐dose cholecalciferol reported deficiencies, likely related to administration losses. Albinsson et al. [4] showed substantial losses of vitamin D in syringes and feeding tubes due to adsorption to plastic surfaces or dead space. Losses depend on vitamin lipophilicity, pKa, steric hindrance, excipients, flow rates, tubing length, temperature, and plastic composition.

Multivitamin solutions containing vitamin C improved vitamin D recovery, possibly by reducing hydrophobic interactions [4]. Dilution may reduce adsorption but could compromise stability under light or heat, although degradation is generally slow unless reactive metals are present.

Although all NICUs using cholecalciferol administered it undiluted, deficiencies still occurred even at high doses and via oral delivery. Practical factors—such as challenges in swallowing drops, retention in syringe dead space, or adhesion to tubing—likely limit effective delivery. Sublingual absorption remains unvalidated in preterm populations.

This nationwide survey highlights heterogeneity in vitamin D practices across French NICUs, consistent with findings from the U.S. [5] and England [3]. Variability concerns not only dosing and monitoring frequency but also formulation type and technical aspects of administration. Administration of 1000 IU/day of ergocalciferol in a multivitamin formulation appeared more effective in preventing deficiency than lipid‐based cholecalciferol, though not without risk of excess. Practices involving cholecalciferol showed greater variability, likely due to sorption‐related losses. These findings indicate that clinical outcomes depend not only on prescribed dose but also on formulation, concentration, and delivery technique.

Trials and international guidelines should address not only dosing and monitoring but also physicochemical and technical factors influencing bioavailability.

In the meantime, regular monitoring of 25(OH)D remains essential to avoid both deficiency and excess. In addition, the widespread but inconsistent use of vitamin D analogs calls for controlled trials to determine safety, efficacy, and optimal dosing in preterm infants.

Author Contributions

Sophie Laborie: conceptualization, methodology, data curation, investigation, validation, formal analysis, writing – original draft, software. Manon Breniaux: validation, writing – review and editing, resources. Justine Bacchetta: conceptualization, validation, supervision, writing – review and editing, resources. Marine Butin: validation, visualization, writing – review and editing, supervision.

Funding

The authors have nothing to report.

Conflicts of Interest

The authors declare no conflicts of interest.

Data Availability Statement

The data that support the findings of this study are available from the corresponding author upon reasonable request.

References

1 A. Kołodziejczyk‐Nowotarska , R. Bokiniec , and J. Seliga‐Siwecka , “Monitored Supplementation of Vitamin D in Preterm Infants: A Randomized Controlled Trial ,” Nutrients 13 (2021 ): 3442. 34684442 10.3390/nu13103442 PMC8537871
2 J. Bacchetta , T. Edouard , G. Laverny , et al., “Vitamin D and Calcium Intakes in General Pediatric Populations: A French Expert Consensus Paper ,” Archives de Pédiatrie 29 (2022 ): 312 –325 . 35305879 10.1016/j.arcped.2022.02.008
3 A. Chinoy , M. Z. Mughal , and R. Padidela , “Metabolic Bone Disease of Prematurity—National Survey of Current Neonatal and Paediatric Endocrine Approaches ,” Acta Paediatrica 110 (2021 ): 1855 –1862 . 33145793 10.1111/apa.15654 PMC8246552
4 E. Albinsson , A. B. Grönlund , M. Paulsson , S. Wikström , and F. Ahlsson , “Unpredictable Supplementation of Vitamin D to Infants in the Neonatal Intensive Care Unit: An Experimental Study ,” Acta Paediatrica 113 (2024 ): 2398 –2405 . 38972986 10.1111/apa.17351
5 M. Romero‐Lopez , M. Naik , L. F. Holzapfel , et al., “Survey of Vitamin D Supplementation Practices in Extremely Preterm Infants ,” Pediatric Research 97 (2025 ): 1009 –1015 . 39191950 10.1038/s41390-024-03514-8 PMC11865359
Publication and source details

Original title: Modalities of Vitamin D Administration to Preterm Infants: Impact on 25 OH Vitamin D Levels

Sophie Laborie; Manon Breniaux; Justine Bacchetta; Marine Butin

Acta Paediatrica (Oslo, Norway : 1992) · 2025

* Correspondence:
Sophie Laborie (sophie.laborie@chu-lyon.fr)
© 2025 The Author(s). Acta Paediatrica published by John Wiley & Sons Ltd on behalf of Foundation Acta Paediatrica.https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-10T23:59:02.776831+00:00

DOI: 10.1111/apa.70422 · PMC12975702