Secondary relevance to vitamin D This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.
This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.
Why this paper is included
Supporting source evidence:
Baseline laboratory parameters revealed statistically significant differences between groups for Ferritin (p < 0.001), WBC (p = 0.045), Creatinine (p = 0.014), Free T4 (p = 0.014), LDL cholesterol (p = 0.009), Calcium (p < 0.001), Vitamin D (p < 0.001), and Vitamin B12 (p < 0.001).
Source: Baseline Characteristics. View original paper
Relevance classification does not establish study quality, causation or editorial approval.
Study design Randomised controlled trial.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Meta-analysis unclear · Single-blind reported · Human research reported
How this paper was classified
Automatic source-based classification; awaiting editorial verification. This is not a quality score.
Ring-Augmented Versus Non-Ring Augmented Sleeve Gastrectomy in Patients with BMI > 50 kg/m²: 3-Year Follow-up of a Randomized Controlled Trial
Source: Article title.
In this single-center, prospective, single-blind randomized trial, adults with a BMI > 50 kg/m² were randomized to SG or Ra-SG and followed for 36 months.
Source: Abstract.
Participants were administered identical perioperative and postoperative care protocols to ensure consistency between groups.
Source: Methods.
What the study types mean
- Systematic review
- Uses explicit methods to identify, assess and summarise research on a defined question.
- Scoping review
- Maps the extent and characteristics of research on a topic.
- Narrative review
- Discusses existing research; systematic-review methods have not been established by this classification.
- Review / evidence synthesis
- Reviews existing research; the exact review methods need further assessment.
- Randomised controlled trial
- Assigns participants or groups to comparison interventions by chance.
- Non-randomised intervention study
- Examines an intervention without random allocation.
- Cohort study
- Examines exposures and outcomes over time within a defined group.
- Case-control study
- Compares people with an outcome against people without it, examining exposures.
- Cross-sectional study
- Examines a population at a particular point in time.
- Observational study
- Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
- Case report
- Describes an individual case.
- Case series
- Describes a group of individual cases.
- Secondary analysis
- Analyses existing study data; this paper is not automatically another independent trial.
- Laboratory study
- Investigates biological processes in a laboratory setting.
- Qualitative study
- Examines experiences or meanings using qualitative methods.
- Genetic instrumental-variable study
- Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
- Study protocol
- Describes planned methods and is not evidence that the planned study has reported results.
- Multiple reported designs
- More than one design is explicitly reported; examine the supporting methods.
- Study design awaiting verification
- The available source does not establish a sufficiently clear study design.
Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.
Abstracts
Ring-Augmented Versus Non-Ring Augmented Sleeve Gastrectomy in Patients with BMI > 50 kg/m²: 3-Year Follow-up of a Randomized Controlled Trial
Randomised controlled trial · Obesity Surgery · 2026
Original publication title
Ring-Augmented Versus Non-Ring Augmented Sleeve Gastrectomy in Patients with BMI > 50 kg/m²: 3-Year Follow-up of a Randomized Controlled Trial
© The Author(s) 2026
Original publication · Publisher record · CC BY 4.0
Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.
At a glance
Abstract: What background does the paper provide?
Sleeve gastrectomy (SG) is effective but prone to late recurrent weight gain (RWG). Ring-augmented SG (Ra-SG) may preserve restriction and enhance long-term durability.
Source: BackgroundAbstract: What methods does the paper describe?
In this single-center, prospective, single-blind randomized trial, adults with a BMI > 50 kg/m² were randomized to SG or Ra-SG and followed for 36 months. The primary endpoint was percent total weight loss (%TWL) at 36 months. Secondary outcomes included RWG, gastric pouch volumetry, relapse of associated medical problems, complications, endoscopic findings, laboratory parameters, and patient-reported outcomes (SF-36, Suter).
Source: MethodsAbstract: Results
Ra-SG produced significantly greater weight loss at 36 months (48.8 ± 8.3 vs. 45.5 ± 9.0%TWL; mean difference 3.25% points, 95% CI 0.86 to 5.63; p 0.008). Exploratory analyses showed lower rates of clinically significant RWG (≥ 30% regain: 5.9% vs. 16.3%; absolute risk difference − 10.4%, 95% CI − 19.6 to − 1.2; p = 0.033) and smaller pouch volumes (160.1 ± 8.9 vs. 194.2 ± 10.3 mL; p < 0.001). Perioperative complications were infrequent and comparable. At three years, the prevalence of endoscopic GERD was similar (17.3% vs. 19.6%).
Food tolerance scores were consistently better after SG (all p < 0.05). HRQoL improved significantly in both groups, with no differences observed at 36 months. Two Ra-SG patients (1.8%) underwent ring removal.
Source: ResultsAbstract: Conclusions
Ra-SG enhanced weight-loss durability and lowered RWG compared to SG, with similar safety and GERD outcomes but decreased food tolerance at mid-term. Ra-SG may be considered in patients at higher risk of RWG, though multicenter studies with longer follow-up are needed to confirm these findings.
Source: ConclusionsAuthors’ abstract
Background
Sleeve gastrectomy (SG) is effective but prone to late recurrent weight gain (RWG). Ring-augmented SG (Ra-SG) may preserve restriction and enhance long-term durability.
Methods
In this single-center, prospective, single-blind randomized trial, adults with a BMI > 50 kg/m² were randomized to SG or Ra-SG and followed for 36 months. The primary endpoint was percent total weight loss (%TWL) at 36 months. Secondary outcomes included RWG, gastric pouch volumetry, relapse of associated medical problems, complications, endoscopic findings, laboratory parameters, and patient-reported outcomes (SF-36, Suter).
Results
Ra-SG produced significantly greater weight loss at 36 months (48.8 ± 8.3 vs. 45.5 ± 9.0%TWL; mean difference 3.25% points, 95% CI 0.86 to 5.63; p 0.008). Exploratory analyses showed lower rates of clinically significant RWG (≥ 30% regain: 5.9% vs. 16.3%; absolute risk difference − 10.4%, 95% CI − 19.6 to − 1.2; p = 0.033) and smaller pouch volumes (160.1 ± 8.9 vs. 194.2 ± 10.3 mL; p < 0.001). Perioperative complications were infrequent and comparable. At three years, the prevalence of endoscopic GERD was similar (17.3% vs. 19.6%).
Food tolerance scores were consistently better after SG (all p < 0.05). HRQoL improved significantly in both groups, with no differences observed at 36 months. Two Ra-SG patients (1.8%) underwent ring removal.
Conclusions
Ra-SG enhanced weight-loss durability and lowered RWG compared to SG, with similar safety and GERD outcomes but decreased food tolerance at mid-term. Ra-SG may be considered in patients at higher risk of RWG, though multicenter studies with longer follow-up are needed to confirm these findings.
Supplementary Information
The online version contains supplementary material available at 10.1007/s11695-025-08431-1.
Key Points
1. Ring-augmented Sleeve gastrectomy (Ra-SG) achieved greater %TWL at 3 years vs. Sleeve gastrectomy (+ 3.25% points, 95% CI 0.86 to 5.63; p = 0.008).
2. Recurrent weight gain (RWG) ≥ 30% was less frequent in Ra-SG (5.9% vs. 16.3%; absolute risk difference − 10.4%, 95% CI − 19.6 to − 1.2).
3. Safety and GERD profiles were similar between groups; ring removals were rare (1.8%).
4. Food tolerance was worse after Ra-SG at all follow-ups; counseling on eating behavior and adaptation is essential.
5. Health-Related Quality of Life (HRQoL) improved similarly in both groups; Ra-SG’s main value is weight-loss durability, not incremental HRQoL gains.
Supplementary Information
The online version contains supplementary material available at 10.1007/s11695-025-08431-1.
Publication and source details
Original title: Ring-Augmented Versus Non-Ring Augmented Sleeve Gastrectomy in Patients with BMI > 50 kg/m²: 3-Year Follow-up of a Randomized Controlled Trial
Mohamed Hany; Walid El Ansari; Mohamed H. Zidan; Anwar Ashraf Abouelnasr; Mohamed Ibrahim; Hazem Al Momani; Ala Wafa; Ehab Elmongui; Bart Torensma
Obesity Surgery · 2026
© The Author(s) 20262026https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.Alexandria UniversityOpen access funding provided by The Science, Technology & Innovation Funding Authority (STDF) in cooperation with The Egyptian Knowledge Bank (EKB).
Repository JATS snapshot; version as supplied
Source retrieved: 2026-11-11T00:29:01.966064+00:00
DOI: 10.1007/s11695-025-08431-1 · PMC13038747