Vitamin D3 for Life

Live Enlightened

Research libraryVitamin D3 For Life
Study design and methods

Primary relevance to vitamin D Vitamin D is a stated subject of this paper.

Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.

Why this paper is included

Supporting source evidence:

The aim of the present study was to evaluate the predictive value of 25-hydroxyvitamin D, calcium and parathormone level, co-existence of thyroid nodule, thyroidectomy history and adenoma volume on the success of neck ultrasound (US) and technetium-99m sestamibi (MIBI) scan in primary hyperparathyroidism (PHP) patients.

Source: Abstract. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Study design awaiting verification.

Study design awaiting verification

The available source does not establish a sufficiently clear study design.

Meta-analysis unclear · Blinding unclear / not reported · Human research reported

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

Patients were excluded if they had been prescribed calcium and vitamin D supplements during the 3 months before diagnosis, or if they were diagnosed with secondary or tertiary hyperparathyroidism.

Source: Methods.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Abstracts

Serum Vitamin D Level Does not Affect The Sensitivity of Parathyroid Adenoma Localization Tests

Study design awaiting verification · Scientific Reports · 2019

Original publication title

Serum Vitamin D Level Does not Affect The Sensitivity of Parathyroid Adenoma Localization Tests

Muhammed Erkam Sencar; Davut Sakiz; Ilknur Ozturk Unsal; Sema Hepsen; Murat Calapkulu; Pelin Gumus; Bekir Ucan; Mustafa Ozbek; Erman Cakal

© The Author(s) 2019

Original publication · Publisher record · CC BY 4.0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

At a glance

What does the authors’ abstract report?

The aim of the present study was to evaluate the predictive value of 25-hydroxyvitamin D, calcium and parathormone level, co-existence of thyroid nodule, thyroidectomy history and adenoma volume on the success of neck ultrasound (US) and technetium-99m sestamibi (MIBI) scan in primary hyperparathyroidism (PHP) patients. This study included 256 patients with PHP who underwent parathyroidectomy. 169 (%66) patients had vitamin D deficiency and 56 (%22) of patients had insufficiency. The sensitivity of US and MIBI studies showed no difference between vitamin D deficiency, insufficiency and replete groups (%80.5, %82 and %71 (p > 0.05) and %81, %84 and %71 respectively (p > 0.05)).

Vitamin D level was not found to be an independent predictor of localization on either US or MIBI scan after adjusting for different variables (p > 0.05). Calcium level was found to be an independent predictor for US sensitivity (r2:0,033, p:0,032) and parathormone level for MIBI sensitivity (r2:0,05, p:0,025). The co-existence of nodular thyroid disease and history of thyroidectomy significantly decreased the sensitivity of US (%76 and %43). MIBI sensitivity was not impaired by nodular disease but the history of thyroidectomy also impaired the sensitivity of MIBI (%43).

As a result vitamin D level does not affect the sensitivity of preoperative localization tests.

Authors’ abstract

The aim of the present study was to evaluate the predictive value of 25-hydroxyvitamin D, calcium and parathormone level, co-existence of thyroid nodule, thyroidectomy history and adenoma volume on the success of neck ultrasound (US) and technetium-99m sestamibi (MIBI) scan in primary hyperparathyroidism (PHP) patients. This study included 256 patients with PHP who underwent parathyroidectomy. 169 (%66) patients had vitamin D deficiency and 56 (%22) of patients had insufficiency. The sensitivity of US and MIBI studies showed no difference between vitamin D deficiency, insufficiency and replete groups (%80.5, %82 and %71 (p > 0.05) and %81, %84 and %71 respectively (p > 0.05)).

Vitamin D level was not found to be an independent predictor of localization on either US or MIBI scan after adjusting for different variables (p > 0.05). Calcium level was found to be an independent predictor for US sensitivity (r2:0,033, p:0,032) and parathormone level for MIBI sensitivity (r2:0,05, p:0,025). The co-existence of nodular thyroid disease and history of thyroidectomy significantly decreased the sensitivity of US (%76 and %43). MIBI sensitivity was not impaired by nodular disease but the history of thyroidectomy also impaired the sensitivity of MIBI (%43).

As a result vitamin D level does not affect the sensitivity of preoperative localization tests.

Publication and source details

Original title: Serum Vitamin D Level Does not Affect The Sensitivity of Parathyroid Adenoma Localization Tests

Muhammed Erkam Sencar; Davut Sakiz; Ilknur Ozturk Unsal; Sema Hepsen; Murat Calapkulu; Pelin Gumus; Bekir Ucan; Mustafa Ozbek; Erman Cakal

Scientific Reports · 2019

© The Author(s) 2019https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/.

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-11T19:15:37.287846+00:00

DOI: 10.1038/s41598-019-48536-z · PMC6700071