Secondary relevance to vitamin D This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.
This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.
Why this paper is included
Supporting source evidence:
Direct loading on an SPE cartridge, predictably, is not able to unbind free vitamin D metabolites, which is shown in Figure 1a (low extraction efficiency is observed because most analytes, while still in the bound state, did not fully adsorb to the stationary phase) and in Figure 1b (low matrix effect because eluted fraction was very pure).
Source: 2.1. Principally Different Sample Preparation Approaches. View original paper
Relevance classification does not establish study quality, causation or editorial approval.
Study design Study design awaiting verification.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.
Meta-analysis unclear · Blinding unclear / not reported · Research setting awaiting verification
How this paper was classified
Automatic source-based classification; awaiting editorial verification. This is not a quality score.
What the study types mean
- Systematic review
- Uses explicit methods to identify, assess and summarise research on a defined question.
- Scoping review
- Maps the extent and characteristics of research on a topic.
- Narrative review
- Discusses existing research; systematic-review methods have not been established by this classification.
- Review / evidence synthesis
- Reviews existing research; the exact review methods need further assessment.
- Randomised controlled trial
- Assigns participants or groups to comparison interventions by chance.
- Non-randomised intervention study
- Examines an intervention without random allocation.
- Cohort study
- Examines exposures and outcomes over time within a defined group.
- Case-control study
- Compares people with an outcome against people without it, examining exposures.
- Cross-sectional study
- Examines a population at a particular point in time.
- Observational study
- Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
- Case report
- Describes an individual case.
- Case series
- Describes a group of individual cases.
- Secondary analysis
- Analyses existing study data; this paper is not automatically another independent trial.
- Laboratory study
- Investigates biological processes in a laboratory setting.
- Qualitative study
- Examines experiences or meanings using qualitative methods.
- Genetic instrumental-variable study
- Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
- Study protocol
- Describes planned methods and is not evidence that the planned study has reported results.
- Multiple reported designs
- More than one design is explicitly reported; examine the supporting methods.
- Study design awaiting verification
- The available source does not establish a sufficiently clear study design.
Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.
Abstracts
Serum Vitamin D Metabolites by HPLC-MS/MS Combined with Differential Ion Mobility Spectrometry: Aspects of Sample Preparation without Derivatization
Study design awaiting verification · International Journal of Molecular Sciences · 2023
Original publication title
Serum Vitamin D Metabolites by HPLC-MS/MS Combined with Differential Ion Mobility Spectrometry: Aspects of Sample Preparation without Derivatization
© 2023 by the authors.
Original publication · Publisher record · CC BY 4.0
Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.
At a glance
What does the authors’ abstract report?
In current clinical practice, a thorough understanding of vitamin D metabolism is in high demand both for patients with various diseases and for healthy individuals. Analytical techniques that provide simultaneous measurement of multiple metabolites are preferred. Herein, the development of an HPLC-DMS-MS/MS method for the quantitation of vitamin D compounds (25(OH)D3, 25(OH)D2, 1,25(OH)2D3, 3-epi-25(OH)D3, 24,25(OH)2D3, and D3) in serum is described. The selected sample preparation procedure based on the combination of liquid: liquid and solid-phase extraction, which excluded a lengthy derivatization step, was compared with other common approaches.
Sensitivity was increased through the implementation of differential ion mobility separation. The proposed assay allowed us to determine the low abundant 1,25(OH)2D3 with the detection limit of 10 pg/mL. The validation study showed good linearity (r2 > 0.99), a wide analytical range (2.5 to 75 ng/mL for 25(OH)D3), and acceptable precision (<7%) for all metabolites. The recovery ranged from 71% to 93% and the matrix effect from 0.80 to 0.95 depending on the metabolite; accuracy determination was performed using DEQAS controls.
Authors’ abstract
In current clinical practice, a thorough understanding of vitamin D metabolism is in high demand both for patients with various diseases and for healthy individuals. Analytical techniques that provide simultaneous measurement of multiple metabolites are preferred. Herein, the development of an HPLC-DMS-MS/MS method for the quantitation of vitamin D compounds (25(OH)D3, 25(OH)D2, 1,25(OH)2D3, 3-epi-25(OH)D3, 24,25(OH)2D3, and D3) in serum is described. The selected sample preparation procedure based on the combination of liquid: liquid and solid-phase extraction, which excluded a lengthy derivatization step, was compared with other common approaches.
Sensitivity was increased through the implementation of differential ion mobility separation. The proposed assay allowed us to determine the low abundant 1,25(OH)2D3 with the detection limit of 10 pg/mL. The validation study showed good linearity (r2 > 0.99), a wide analytical range (2.5 to 75 ng/mL for 25(OH)D3), and acceptable precision (<7%) for all metabolites. The recovery ranged from 71% to 93% and the matrix effect from 0.80 to 0.95 depending on the metabolite; accuracy determination was performed using DEQAS controls.
Publication and source details
Original title: Serum Vitamin D Metabolites by HPLC-MS/MS Combined with Differential Ion Mobility Spectrometry: Aspects of Sample Preparation without Derivatization
Liliia Usoltseva; Vitaliy Ioutsi; Yuriy Panov; Mariya Antsupova; Liudmila Rozhinskaya; Galina Melnichenko; Natalia Mokrysheva
International Journal of Molecular Sciences · 2023
* Correspondence: usoltseva.liliya@endocrincentr.ru© 2023 by the authors.2023https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).Russian Science Foundation19-15-00243-PMinistry of Science and Higher Education of the Russian Federation075-15-2020-899All reagents, materials, and consumables were supported by the Russian Science Foundation under contract number 19-15-00243-P (URL: https://rscf.ru/project/19-15-00243/ accessed on 9 April 2023). The liquid chromatography system was acquired with funding from the Ministry of Science and Higher Education of the Russian Federation (agreement no. 075-15-2020-899).Repository JATS snapshot; version as supplied
Source retrieved: 2026-11-11T01:10:12.995687+00:00
DOI: 10.3390/ijms24098111 · PMC10179168