Vitamin D3 for Life

Live Enlightened

Research libraryVitamin D3 For Life
Study design and methods

Primary relevance to vitamin D Vitamin D is a stated subject of this paper.

Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.

Why this paper is included

Supporting source evidence:

Simultaneous Determination of Vitamins D3 (Calcitriol, Cholecalciferol) and K2 (Menaquinone-4 and Menaquinone-7) in Dietary Supplements by UHPLC

Source: Article title. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Study design awaiting verification.

Study design awaiting verification

The available source does not establish a sufficiently clear study design.

Meta-analysis unclear · Blinding unclear / not reported · Research setting awaiting verification

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Abstracts

Simultaneous Determination of Vitamins D3 (Calcitriol, Cholecalciferol) and K2 (Menaquinone-4 and Menaquinone-7) in Dietary Supplements by UHPLC

Study design awaiting verification · Molecules · 2021

Original publication title

Simultaneous Determination of Vitamins D3 (Calcitriol, Cholecalciferol) and K2 (Menaquinone-4 and Menaquinone-7) in Dietary Supplements by UHPLC

Anca Becze; Vanda Liliana Babalau Fuss; Daniela Alexandra Scurtu; Maria Tomoaia-Cotisel; Aurora Mocanu; Oana Cadar

© 2021 by the authors.

Original publication · Publisher record · CC BY 4.0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

At a glance

What does the authors’ abstract report?

The content and composition of dietary supplements is of great interest due to their increasing consumption and variety of available brand offered in the market. Accurate determination of vitamins is important for the improvement of dietary supplement quality and nutrition assessments. In this regard, the simultaneous determination of vitamin D3 (calcitriol: CT and cholecalciferol: CHL) and K2 (menaquinone-4: MK-4 and menaquinone-7: MK-7) in dietary supplements was developed by using ultra-high-pressure liquid chromatography (UHPLC). The overall runtime per sample was above 35 min, with the retention times of 2.40, 6.59, 7.06, and 32.6 min for vitamin D3 (CT and CHL) and vitamin K2 (MK-4 and MK-7), respectively.

The limits of detection and limits of quantification for the target nutritional compounds ranged between 0.04 to 0.05 µg/mL, respectively. The validation results indicated that the method had reasonable linearity (R2 ≥ 0.9990), good recovery (>82%), satisfactory intra-day precision (≤1.9%) and inter-day precision (≤3.5%), and high selectivity and specificity. The validated UHPLC method was demonstrated to be precise, accurate, and robust for the simultaneous determination of vitamins D3 (CT and CHL) and K2 (MK-4 and MK-7) in dietary supplements.

Authors’ abstract

The content and composition of dietary supplements is of great interest due to their increasing consumption and variety of available brand offered in the market. Accurate determination of vitamins is important for the improvement of dietary supplement quality and nutrition assessments. In this regard, the simultaneous determination of vitamin D3 (calcitriol: CT and cholecalciferol: CHL) and K2 (menaquinone-4: MK-4 and menaquinone-7: MK-7) in dietary supplements was developed by using ultra-high-pressure liquid chromatography (UHPLC). The overall runtime per sample was above 35 min, with the retention times of 2.40, 6.59, 7.06, and 32.6 min for vitamin D3 (CT and CHL) and vitamin K2 (MK-4 and MK-7), respectively.

The limits of detection and limits of quantification for the target nutritional compounds ranged between 0.04 to 0.05 µg/mL, respectively. The validation results indicated that the method had reasonable linearity (R2 ≥ 0.9990), good recovery (>82%), satisfactory intra-day precision (≤1.9%) and inter-day precision (≤3.5%), and high selectivity and specificity. The validated UHPLC method was demonstrated to be precise, accurate, and robust for the simultaneous determination of vitamins D3 (CT and CHL) and K2 (MK-4 and MK-7) in dietary supplements.

Publication and source details

Original title: Simultaneous Determination of Vitamins D3 (Calcitriol, Cholecalciferol) and K2 (Menaquinone-4 and Menaquinone-7) in Dietary Supplements by UHPLC

Anca Becze; Vanda Liliana Babalau Fuss; Daniela Alexandra Scurtu; Maria Tomoaia-Cotisel; Aurora Mocanu; Oana Cadar

Molecules · 2021

* Correspondence: oana.cadar@icia.ro© 2021 by the authors.2021https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-11T11:35:54.641675+00:00

DOI: 10.3390/molecules26226982 · PMC8624398