Vitamin D3 for Life

Live Enlightened

Research libraryVitamin D3 For Life
Study design and methods

Primary relevance to vitamin D Vitamin D is a stated subject of this paper.

Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.

Why this paper is included

Supporting source evidence:

The pre‐analytical stability of 25‐hydroxyvitamin D: Storage and mixing effects

Source: Article title. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Study design awaiting verification.

Study design awaiting verification

The available source does not establish a sufficiently clear study design.

Meta-analysis unclear · Blinding unclear / not reported · Research setting awaiting verification

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Abstracts

The pre‐analytical stability of 25‐hydroxyvitamin D: Storage and mixing effects

Study design awaiting verification · Journal of Clinical Laboratory Analysis · 2019

Original publication title

The pre‐analytical stability of 25‐hydroxyvitamin D: Storage and mixing effects

Anwar Borai; Haitham Khalil; Basma Alghamdi; Raghad Alhamdi; Najwa Ali; Suhad Bahijri; Gordon Ferns

© 2019 The Authors. Journal of Clinical Laboratory Analysis Published by Wiley Periodicals, Inc.

Original publication · Publisher record · CC BY 4.0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

Authors’ conclusion

25‐OH VitD is pre‐analytically stable after long‐term sample storage at −20°C and can be analyzed without vortexing. This may be beneficial for both research and diagnostic laboratories.

An extract from the source publication. Read it in context.

At a glance

Abstract: What background does the paper provide?

There is an increasing demand for serum 25‐OH VitD testing globally, and this has led to the greater use of automated immunoassays. These may be more prone to non‐specific interference, that is thought to be related to pre‐analytical stability of biological samples. We have investigated the changes in serum 25‐OH VitD concentrations that are caused by storage and mixing conditions, and if such changes are statistical, or clinically important.

Source: Background

Abstract: What methods does the paper describe?

Blood samples were collected into plain tubes from 31 healthy donors. After separation, serum samples were stored at −20°C and analysis was carried out with and without mixing (vortexing) at different time intervals of days (0, 1, 2, 3, 4, 5, 15, and 30). All samples were analyzed using a chemiluminescent immunoassay.

Source: Methods

Abstract: Results

Mean serum 25‐OH VitD concentrations for subsequent days of storage compared with day 0 showed a significant time effect (P < .05) except for the samples on day 1 (P = .654) in non‐vortexed samples and day 2 (P = .087), 5 (P = .118) and 30 (P = .118) in vortexed samples. Comparing values for vortexed and non‐vortexed samples on the same day, serum 25‐OH VitD showed a significant difference on days 1 (P = .003), 4 (P = .037), 5 (P = .002), and 30 (P = .025).

However, the maximum change value was 8.85% which was less than the known total allowable error (TEa) and reference change value (RCV) for serum 25‐OH VitD.

Source: Results

Abstract: Conclusion

25‐OH VitD is pre‐analytically stable after long‐term sample storage at −20°C and can be analyzed without vortexing. This may be beneficial for both research and diagnostic laboratories.

Source: Conclusion
Authors’ abstract

Abstract

Background

There is an increasing demand for serum 25‐OH VitD testing globally, and this has led to the greater use of automated immunoassays. These may be more prone to non‐specific interference, that is thought to be related to pre‐analytical stability of biological samples. We have investigated the changes in serum 25‐OH VitD concentrations that are caused by storage and mixing conditions, and if such changes are statistical, or clinically important.

Methods

Blood samples were collected into plain tubes from 31 healthy donors. After separation, serum samples were stored at −20°C and analysis was carried out with and without mixing (vortexing) at different time intervals of days (0, 1, 2, 3, 4, 5, 15, and 30). All samples were analyzed using a chemiluminescent immunoassay.

Results

Mean serum 25‐OH VitD concentrations for subsequent days of storage compared with day 0 showed a significant time effect (P < .05) except for the samples on day 1 (P = .654) in non‐vortexed samples and day 2 (P = .087), 5 (P = .118) and 30 (P = .118) in vortexed samples. Comparing values for vortexed and non‐vortexed samples on the same day, serum 25‐OH VitD showed a significant difference on days 1 (P = .003), 4 (P = .037), 5 (P = .002), and 30 (P = .025).

However, the maximum change value was 8.85% which was less than the known total allowable error (TEa) and reference change value (RCV) for serum 25‐OH VitD.

Conclusion

25‐OH VitD is pre‐analytically stable after long‐term sample storage at −20°C and can be analyzed without vortexing. This may be beneficial for both research and diagnostic laboratories.

Publication and source details

Original title: The pre‐analytical stability of 25‐hydroxyvitamin D: Storage and mixing effects

Anwar Borai; Haitham Khalil; Basma Alghamdi; Raghad Alhamdi; Najwa Ali; Suhad Bahijri; Gordon Ferns

Journal of Clinical Laboratory Analysis · 2019

* Correspondene
Anwar Borai, King Abdullah International Medical Research Center, King Saud bin Abdulaziz University for Health Sciences, Pathology, King Abdulaziz Medical City, P.O. Box 9515 Jeddah 21423, Saudi Arabia.
Email: boraiaa@ngha.med.sa
© 2019 The Authors. Journal of Clinical Laboratory Analysis Published by Wiley Periodicals, Inc.https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-11T18:16:15.227912+00:00

DOI: 10.1002/jcla.23037 · PMC7031638