Vitamin D3 for Life. Live Enlightened.

Research libraryVitamin D3 For Life
Study design and methods

Primary relevance to vitamin D Vitamin D is a stated subject of this paper.

Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.

Why this paper is included

Supporting source evidence:

The availability of target values for free 25(OH)D in these SRMs will allow researchers to validate new analytical methods and to compare their results with other researchers as an initial step towards harmonization of measurements among different studies and laboratories.

Source: Abstract. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Study design awaiting verification.

Study design awaiting verification

The available source does not establish a sufficiently clear study design.

Meta-analysis unclear · Blinding unclear / not reported · Research setting awaiting verification

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Full studies

Towards harmonization of directly measured free 25-hydroxyvitamin D using an enzyme-linked immunosorbent assay

Study design awaiting verification · Analytical and Bioanalytical Chemistry · 2022

Original publication title

Towards harmonization of directly measured free 25-hydroxyvitamin D using an enzyme-linked immunosorbent assay

Christopher T. Sempos; Ernst Lindhout; Nicolas Heureux; Michel Hars; Damon A. Parkington; Emily Dennison; Ramón Durazo-Arvizu; Kerry S. Jones; Stephen A. Wise

© The Author(s) 2022

Original publication · Publisher record · CC BY 4.0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

At a glance

Study background

What background does the paper provide?

Because of the importance of vitamin D in human health and development, in either the D2 (ergocalciferol) or D3 (cholecalciferol) form, testing for vitamin D in human serum has become routine to diagnose and monitor deficiency. The major circulating form of vitamin D and the primary marker of vitamin D status is 25-hydroxyvitamin D [25(OH)D], which is defined as the sum of 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3]. Measurements of 25(OH)D are typically performed using a ligand binding assay, which responds to both 25(OH)D2 and 25(OH)D3 and thereby provides total 25(OH)D, or using liquid chromatography–tandem mass spectrometry (LC–MS/MS), which measures the 25(OH)D2 and 25(OH)D3 individually.

Recent reviews [1–5] have discussed the challenges and difficulties in assessing vitamin D status, and recent studies [6–11] have demonstrated the variability of results among different 25(OH)D assays.

Like other steroid hormones, circulating 25(OH)D is primarily bound to proteins, with 85% to 90% strongly bound to vitamin D binding protein (VDBP), a specific transport protein for vitamin D; 10% to 15% is loosely bound to serum albumin; and only 0.02% to 0.04% exists in a free, unbound form [12–14]. Recent studies have suggested that the measurement of free 25(OH)D may be a better indicator of vitamin D status than the total 25(OH)D content [14–16], and several reviews have discussed the basis of these conclusions [12, 13, 15, 17, 18].

Methods for the determination of 25(OH)D have been available since the 1970s; however, methods for the determination of free 25(OH)D were first described in the 1980s based on centrifugal ultrafiltration using 3H-labeled 25(OH)D3 and 14C-labeled glucose. However, the method was not used extensively because it is time-consuming and expensive [19, 20]. Using affinity constants determined from centrifugal ultrafiltration measurements, Bikle et al. [19] proposed a calculation method in 1986 to determine free 25(OH)D using the measured total 25(OH)D, VDBP, and albumin concentrations and the estimated affinity constants between 25(OH)D and VDBP and albumin.

In the early 2010s, an enzyme-linked immunosorbent assay (ELISA) was developed [21] and became commercially available for the direct measurement of free 25(OH)D. The ELISA is based on monoclonal anti-25(OH)D antibodies and uses a specific incubation buffer that enables the capture of the free fraction of 25(OH)D only [21]. The ELISA was validated and compared with the dialysis technique using 15 samples with a regression line slope of 0.992 and R2 = 0.737 [21].

This ELISA is currently the only commercially available assay for free 25(OH)D, and it has been used for the direct determination of free 25(OH)D in numerous studies since 2013 as documented in a 2018 review by Tsuprykov et al. [18], where the authors summarized 54 original papers reporting measurements of free 25(OH)D from 1984 to 2017 using either dialysis (4%), calculation (65%), or ELISA (31%) methods. In 2020, Wang et al. [22] reported using a method based on preparation using an ultrafiltration tube, derivatization with PTAD, and finally separation and detection by LC–MS/MS for the assessment of free 25(OH)D.

Based on a vitamin D workshop held in 2016 reported by Bikle et al. [15], a clear need for standardization of measurements of VDBP and free 25(OH)D was identified.

To assist in standardization of measurements of 25(OH)D among laboratories and over time, the Office of Dietary Supplements at the National Institutes of Health (NIH-ODS) organized the Vitamin D Standardization Program (VDSP) in 2010 [23, 24], a collaboration among NIH-ODS, the National Institute of Standards and Technology (NIST), the Centers for Disease Control and Prevention (CDC), and national survey laboratories in several countries. A reference measurement system has been established that includes reference measurement procedures (RMPs) at NIST [25, 26], Ghent University [27], and CDC [28]; NIST Standard Reference Materials® (SRMs) [29–31]; the CDC Vitamin D Standardization – Certification Program (VDSCP) [32]; and collaborations with two accuracy-based proficiency testing/external quality assessment (PT/EQA) programs, i.e., the US College of American Pathologists (CAP) accuracy-based vitamin D (ABVD) program [33] and the UK-based Vitamin D External Quality Assessment Scheme (DEQAS) [34, 35].

In 2009, NIST issued the first frozen serum matrix SRM for the determination of vitamin D metabolites including 25(OH)D2, 25(OH)D3, and 3-epi-25-hydroxyvitamin D3, i.e., SRM 972 Vitamin D in Frozen Human Serum with four serum pools with different levels of the metabolites [29]. When the inventory of SRM 972 was exhausted in 2011, an improved SRM 972a Vitamin D Metabolites in Frozen Human Serum was developed again with four different serum pools representing different levels of metabolites [30].

In 2017, SRM 2973 Vitamin D Metabolites in Frozen Human Serum (High Level) was released consisting of one serum pool with a high level of 25(OH)D3 (39.4 ng/mL) [31]. In addition to the three metabolites with certified values in SRM 972a, SRM 2973 also had values assigned for 24R,25-dihydroxyvitamin D3, and values for this metabolite were also added to SRM 972a at this time. Recently, a unique SRM was produced with serum from female donors of reproductive age who were either not pregnant or pregnant in each of the three trimesters, i.e., SRM 1949 Frozen Prenatal Human Serum [36].

Intended primarily for the determination of thyroid hormones, SRM 1949 also has values assigned for 25(OH)D2, 25(OH)D3, 3-epi-25-hydroxyvitamin D3, and VDBP. These SRMs have found widespread use within the vitamin D testing and research community during the past decade for method development and validation and as control materials for routine testing with over 4500 units distributed to hospital/clinical centers, university, commercial testing, and government laboratories [24].

The components of the reference measurement system for total 25(OH)D as described above follow the recommendations established for harmonization of clinical laboratory measurement procedures [37–40]. However, at present, there is no reference measurement system in place or harmonization efforts underway regarding the measurement of free 25(OH)D. As a first step towards harmonization of measurements of free 25(OH)D, the goal of this study was to determine target values for free 25(OH)D using the ELISA method in existing SRMs used for the determination of vitamin D metabolites.

With the availability of target values for free 25(OH)D in these SRMs, laboratories can use these SRMs as controls to assure the quality of their measurements and to validate new methods for determination of free 25(OH)D.

Source: Introduction Source: Introduction Source: Introduction Source: Introduction Source: Introduction Source: Introduction

Experimental: SRMs evaluated

Three NIST SRMs with values assigned for 25(OH)D2, 25(OH)D3, and total 25(OH)D were evaluated for the content of free 25(OH)D. SRM 972a Vitamin D Metabolites in Frozen Human Serum (3 units, 1 vial per level) [30] and 2973 Vitamin D Metabolites in Frozen Human Serum (High Level) (2 units, 2 vials per level) [31] were provided by NIST and shipped on dry ice to the two participating laboratories. SRM 1949 Frozen Human Prenatal Serum (2 units, 2 vials per level) [36] was purchased from NIST and shipped on dry ice to the two participating laboratories.

The SRMs were then stored at − 70 °C at each laboratory until analyzed.

Source: SRMs evaluated

Experimental

Experimental: Single-donor samples evaluated and selection of laboratories for the evaluation of SRMs

Prior to this study, an interlaboratory comparison study of the performance of the free 25(OH)D ELISA was conducted among nine laboratories using the ELISA to determine free 25(OH)D. Forty single-donor samples were analyzed from a 50 single-donor sample set used in an earlier interlaboratory comparison exercise for the determination of total 25(OH)D described in Wise et al. [6] with values for total 25(OH)D ranging from 6.5 to 61.1 ng/mL. The results of the analysis of these samples for the determination of 25(OH)D2 and 25(OH)D3 using the NIST reference measurement procedures [25] were reported previously [6].

These 40 samples were analyzed for the determination of free 25(OH)D at the Nutritional Biomarker Laboratory, Medical Research Council (MRC) Epidemiology Unit at the University of Cambridge (Cambridge, UK), using the approach described below. The results from the interlaboratory comparison informed the selection of the laboratories for the evaluation of SRMs in the study reported here.

Source: Single-donor samples evaluated and selection of laboratories for the evaluation of SRMs

Nutritional Biomarker Laboratory (NBL), University of Cambridge

Experimental / Directly measured free 25(OH)D procedures: Nutritional Biomarker Laboratory (NBL), University of Cambridge

The free 25(OH)D ELISA was performed according to the manufacturer’s instructions by a single analyst. Incubation and shaking were performed with a BMG THERMOstar (BMG Labtech Ltd., UK) and washing with a Thermo Wellwash (Thermo Fisher Scientific, UK). Results were read using a Thermo Multiskan (Thermo Fisher Scientific, UK).

Source: Nutritional Biomarker Laboratory (NBL), University of Cambridge

Future Diagnostics

Experimental / Directly measured free 25(OH)D procedures: Future Diagnostics

The free 25(OH)D ELISA was performed according to the manufacturer’s instruction by three different analysts. A Thermo iEMS shaker incubator (Thermo Scientific, USA) was used for the incubation, washing was done using a Biotek elx50, and absorption values were measured using a Biotek elx800 plate reader (Biotek, USA).

Source: Future Diagnostics

Experimental: Statistical methods

All data analyses were conducted using CBStat 5.1 (Copyright by Kristian Linnet, Ordup Have 15, DK-2920 Charlottenlund, Denmark). Paired t test was used to test for significant differences between Future Diagnostics and NBL Cambridge determinations for day, run, and duplicate. Mean paired difference over day, run, and duplicate was calculated as the NBL Cambridge determination minus the Future Diagnostics determination. Ordinary least squares regression analysis was used to compare mean values for each SRM level (n = 9).

Source: Statistical methods

Interlaboratory comparison and selection of laboratories for the evaluation of SRMs

Results and discussion: Interlaboratory comparison and selection of laboratories for the evaluation of SRMs

For the interlaboratory comparison study conducted among nine laboratories using the ELISA to determine free 25(OH)D in a set of 40 single-donor samples [41], overall %CVs for the individual laboratories ranged from 2.8 to 22% with only the assay manufacturer laboratory (Future Diagnostics) and NBL Cambridge achieving %CVs below 4%. The results obtained by Future Diagnostics were considered to be the benchmark, and bias compared to the Future Diagnostics results ranged from 1.3 to 29% with only two laboratories achieving a bias below 5% [41].

The results of this interlaboratory study indicated a need for improvement among laboratories in using this ELISA for the determination of free 25(OH)D. Based on the results of the interlaboratory comparison study, NBL Cambridge and Future Diagnostics were selected to analyze the SRM suite to assign target values for free 25(OH)D using the ELISA.

The NBL Cambridge results for the determination of free 25(OH)D in the 40 single-donor samples are summarized in Table S4. Similar results from the analysis of the same samples by Future Diagnostics are provided in Table S5. These results illustrate the repeatability achievable when using the ELISA. A plot of the free 25(OH)D (NBL Cambridge) concentration versus the NIST Total 25(OH)D in the 40 single-donor samples is shown in Fig. 1, and a similar plot using the Future Diagnostics results for free 25(OH)D is provided in Figure S1 (Supplementary Information).

Fig. 1

Ordinary least squares linear regression for free 25(OH)D and total 25(OH)D in 40 single-donor patient samples. Black circles are the single-donor samples, and the solid red line is the regression line. The red dashed line is the 95% confidence interval for the regression line. Free 25(OH)D measurements performed at NBL Cambridge

Figure image at the original source — open the original paper. This file is not included in this text import.

Source: Interlaboratory comparison and selection of laboratories for the evaluation of SRMs Source: Interlaboratory comparison and selection of laboratories for the evaluation of SRMs

Comparison and combination of results from two laboratories

Results and discussion: Comparison and combination of results from two laboratories

Three NIST SRMs with nine different levels were available with values assigned for 25(OH)D2, 25(OH)D3, total 25(OH)D, and VDBP as summarized in Table 1. Total 25(OH)D concentrations for the nine materials range from 18.9 to 40.1 ng/mL, with 25(OH)D3 ranging from 18.1 to 39.4 ng/mL. For the four levels of SRM 1949, values are assigned for VDBP, which increases in concentration from 211.5 μg/mL in the non-pregnant serum pool to 383.4 μg/mL in the third trimester serum pool.

Table 1

National Institute of Standards and Technology (NIST) Standard Reference Materials (SRM®) with vitamin D metabolite assigned values and uncertainty used in this study

SRM samplesSerum vitamin D metabolitea (ng/mL)Vitamin D binding protein (μg/mL)
25(OH)D225(OH)D3Total 25(OH)D
MeanUncertaintyMeanUncertaintyMeanUncertaintyMeanUncertainty
SRM 972a level 10.540.0628.81.129.31.1NRbNR
SRM 972a level 20.810.0618.10.418.90.4NRNR
SRM 972a level 313.20.319.80.433.00.5NRNR
SRM 972a level 40.550.1029.40.930.00.9NRNR
SRM 29730.650.0239.40.840.10.8NRNR
SRM 1949 NPc0.278NR24.980.2825.3dNR211.52.8
SRM 1949 1Tc1.200.0526.010.2227.2dNR286.73.8
SRM 1949 2Tc0.5140.03730.000.5030.5dNR349.74.3
SRM 1949 3Tc0.8970.05729.430.4130.3dNR383.45.1

aCertified values in bold type; reference values in normal type. Uncertainties for certified and reference values are not equivalent; see SRM Certificate of Analysis (COA) for complete description of the uncertainties of certified and reference values. To convert ng/mL to nmol/L, multiply 25(OH)D2 concentration by 2.423 and 25(OH)D3 concentration by 2.496

bNR, not reported

cNP, non-pregnant; 1T, 1st trimester of pregnancy; 2T, 2nd trimester of pregnancy; and 3T, 3rd trimester of pregnancy

dValues calculated for this study and not assigned by NIST on the SRM COA

All nine levels of the SRMs were analyzed to determine the content of free 25(OH)D using the ELISA in two laboratories. The individual results (n = 12 for each SRM level) from the two laboratories for the determination of free 25(OH)D are provided in Table 2. The paired mean differences between NBL Cambridge and Future Diagnostics measurements were small as shown in Table 3. The results from the two laboratories were combined, and the means and standard deviations are summarized in Table 4.

In six of the nine NIST SRM levels, the NBL Cambridge measurements were slightly higher than the Future Diagnostics Solutions measurements. None of the paired differences were statistically significant (p < 0.05) and the 95% confidence limits for the mean difference in every case included zero. A distribution plot of the results from both laboratories for SRM 972 level 3 is shown in Fig. 2. Similar distribution plots for the remaining SRM samples are provided in Figures S2 to S9 in Supplementary Information.

A plot of the least squares regression of the directly measured free 25(OH)D means from the two laboratories is shown in Fig. 3. The regression line with R2 = 0.99 and slope of 0.977 with 95% confidence interval including zero intercept and slope of 1.00 indicate the near perfect correspondence between the two laboratories for the direct measurement of free 25(OH)D. The standardized residual plot for the regression model shown in Figure S10 (Supplementary Information) does not indicate any violation of the regression model assumptions.

Table 2

Individual measurement results from both laboratories for the three SRMs

SRM 972aSRM 2973SRM 1949
Level 1Level 2Level 3Level 4NPa1st2nd3rd
LabbDayRunRepcFree 25(OH)D3 (pg/mL)d
11117.7505.3418.2618.0349.7426.2224.3313.4713.483
11128.1485.1647.3137.5289.8156.1334.6774.5663.681
11216.9664.9918.1918.40110.2636.1713.7713.9863.288
11227.9174.2107.6918.44210.4796.5645.0045.2424.288
12117.5795.8988.8938.32610.3726.2304.9523.4653.972
12127.8415.1867.5387.7009.6786.4375.0874.6683.982
12217.3545.6948.3738.3949.5016.6804.7554.4063.450
12227.8074.9757.9678.4119.8406.3684.9354.8403.847
13118.1435.2088.1878.0389.5356.0014.9874.1044.013
13127.6554.1857.0967.0969.2645.9554.8754.7833.392
13217.7835.0838.0577.7659.8666.1454.8404.0513.577
13229.3854.8478.4857.3839.6316.5324.9484.4403.846
21117.4214.8177.9237.47010.0226.1614.6104.1163.712
21126.8004.4087.1938.0409.6835.7464.4584.3753.826
21218.7045.7888.3028.66510.9956.6675.2165.3604.359
21228.4725.2238.2838.89211.7046.7405.7955.0664.271
22118.1134.7197.2307.6809.2315.9854.4413.8912.750
22127.1683.9607.1687.1169.8865.3974.1084.1013.553
22217.1774.7197.3247.4979.4585.5344.3604.1453.600
22227.0634.3636.7997.3449.6095.5044.3504.4723.955
23118.1815.2318.5258.71610.9046.3714.6854.4973.732
23127.3483.4357.7657.66810.2156.3924.8784.4973.711
23217.5245.0147.8077.70810.1205.6764.6304.3283.785
23227.6434.6167.5457.18910.1345.9504.1614.7794.293

aNon-pregnant, 1st trimester, 2nd trimester, and 3rd trimester

b1, Nutritional Biomarker Laboratory (NBL), Cambridge; and 2, Future Diagnostics Laboratory

cRep, replicate

dTo convert pg/mL to pmol/L, multiply by 2.496

Table 3

Comparison of paired mean directly measured free 25(OH)D

SRMs®University of CambridgeFuture Diagnostics SolutionsCombinedPaired t test
Concentration (pg/mL)95% CL for
MeanSDMeanSDMeanSDMean differenceaMean difference
SRM 972a level 17.860.587.630.607.750.590.23 − 0.35 to 0.81
SRM 972a level 25.060.504.690.624.880.580.37 − 0.08 to 0.83
SRM 972a level 38.000.507.660.547.830.540.34 − 0.12 to 0.81
SRM 972a level 47.960.467.830.617.900.530.13 − 0.26 to 0.52
SRM 29739.830.3710.160.7210.000.58 − 0.33 − 0.77 to 0.11
SRM 1949 NPb6.290.236.010.466.150.380.28 − 0.09 to 0.64
SRM 1949 1Tb4.760.374.640.474.700.420.12 − 0.31 to 0.56
SRM 1949 2Tb4.340.544.470.424.400.48 − 0.13 − 0.48 to 0.21
SRM 1949 3Tb3.740.303.800.433.760.36 − 0.06 − 0.41 to 0.29

aDifference is NBL Cambridge (pg/mL) – Future Diagnostics Solutions (pg/mL)

bNP, non-pregnant; 1T, 1st trimester of pregnancy; 2T, 2nd trimester of pregnancy; and 3T, 3rd trimester of pregnancy

cTo convert pg/mL to pmol/L multiply by 2.496, except for SRM 972a level 3 which has a high concentration of serum 25(OH)D2

Table 4

Summary of percent of free 25(OH)D3 in the SRMs

Free 25(OH)D3 (pg/mL)Total 25(OH)D (ng/mL)Percent free 25(OH)D
MeanSDMeanUncertaintyaPercentbSDb
SRM 972a level 17.750.5929.31.10.02640.0020
SRM 972a level 24.880.5818.90.40.02580.0031
SRM 972a level 37.830.5433.00.50.02370.0016
SRM 972a level 47.900.5330.00.90.02640.0018
SRM 297310.000.5840.10.80.02500.0015
SRM 1949 NPc6.150.3825.3dNRe0.02460.0015
SRM 1949 1Tc4.700.4227.2dNRe0.01810.0016
SRM 1949 2Tc4.400.4830.5dNRe0.01440.0016
SRM 1949 3Tc3.760.3630.3dNRe0.01240.0012

aUncertainty from the NIST SRM COA

bMean of free 25(OH)D from both laboratories/total 25(OH)D NIST × 100; SD, standard deviation of combined measurements from both laboratories

cNP, non-pregnant; 1T, 1st trimester of pregnancy; 2T, 2nd trimester of pregnancy; and 3T, 3rd trimester of pregnancy

dValues calculated [sum of 25(OH)D2 and 25(OH)D3] for this study and not assigned by NIST on the SRM COA

eNR, not reported on COA

Fig. 2

Distribution of free 25(OH)D (pg/mL) measurements by laboratory for NIST SRM 972a — Vitamin D Metabolites in Frozen Human Serum (level 3). Blue diamonds are the individual measurements. Black bar is the mean value of the 12 measurements

Figure image at the original source — open the original paper. This file is not included in this text import.
Fig. 3

Ordinary least squares regression of the means for directly measured free 25(OH)D concentrations by laboratory. The black solid line is the regression line; the dashed blue line is the identity line (y = x); and the red dashed lines are the 95% confidence interval for the regression line

Figure image at the original source — open the original paper. This file is not included in this text import.

The correlation of directly measured free 25(OH)D with the total 25(OH)D content for the nine SRM levels is shown in Fig. 4. The relationship between free 25(OH)D and total 25(OH)D in the three levels in SRM 1949 representing the three pregnancy trimesters is obviously different from the other SRM serum pools as indicated in Fig. 4 (red dots), and the percent free 25(OH)D was lower in pregnancy compared to non-pregnancy samples. This observation may be explained by the higher circulating level of VDBP observed in pregnant compared to non-pregnant women [42–45] in SRM 1949 where VDBP concentration is associated with directly measured free 25(OH)D concentration between non-pregnancy and pregnancy and in the increased VDBP concentration across gestation (Fig. 5) as reported in longitudinal studies during pregnancy [42, 45].

However, Bikle and Swartz [17] suggest that free 25(OH)D may be the same or only slightly lower during pregnancy.

Fig. 4

Least squares linear regression for free 25(OH)D and total 25(OH)D for nine SRM levels. The black dots and black regression line are SRM 972a, SRM 2973, and SRM 1949 (non-pregnant level); the red dots are for SRM 1949 levels representing the 1st, 2nd, and 3rd trimester serum pools, and the red regression line is for all samples. Regression equation and R2 value in black are for SRM 972a, SRM 2973, and SRM 1949 (non-pregnant level); red regression equation and R2 value are for all samples

Figure image at the original source — open the original paper. This file is not included in this text import.
Fig. 5

Least squares linear regression for free 25(OH)D versus vitamin D binding protein for different SRM 1949 levels

Figure image at the original source — open the original paper. This file is not included in this text import.

Source: Comparison and combination of results from two laboratories Source: Comparison and combination of results from two laboratories Source: Comparison and combination of results from two laboratories

Use of SRMs for harmonization of measurements

Results and discussion: Use of SRMs for harmonization of measurements

The assignment of target values for free 25(OH)D using the ELISA assay in existing SRMs is an initial step towards harmonization and eventual standardization of measurements of free 25(OH)D. These SRMs are available to any researcher for use as control samples or for assigning target values to in-house control materials. The use of these SRMs for reporting free 25(OH)D concentrations in various studies will allow for comparison of results among different laboratories, different studies, and over time. We recommend that users of the ELISA for free 25(OH)D analyze one or more of the SRMs and compare their results with the target values reported in this paper to determine laboratory/assay performance.

If the results are biased, users should evaluate whether the assay protocol has been appropriately followed. Results among different laboratories, and different studies can be harmonized using approaches as described previously for 25(OH)D assays [46, 47].

The availability of additional information characterizing these existing SRMs for vitamin D metabolites enhances the value of these materials [48]. In particular, the addition of free 25(OH)D results to SRM 1949 provides valuable information on the effect of changes in VDBP concentration on free 25(OH)D in pregnancy. This information may also be relevant to other pathological conditions associated with changes in VDBP concentration [49] and their effect on vitamin D metabolism.

Source: Use of SRMs for harmonization of measurements Source: Use of SRMs for harmonization of measurements

Results and discussion

Interlaboratory comparison and selection of laboratories for the evaluation of SRMs

For the interlaboratory comparison study conducted among nine laboratories using the ELISA to determine free 25(OH)D in a set of 40 single-donor samples [41], overall %CVs for the individual laboratories ranged from 2.8 to 22% with only the assay manufacturer laboratory (Future Diagnostics) and NBL Cambridge achieving %CVs below 4%. The results obtained by Future Diagnostics were considered to be the benchmark, and bias compared to the Future Diagnostics results ranged from 1.3 to 29% with only two laboratories achieving a bias below 5% [41].

The results of this interlaboratory study indicated a need for improvement among laboratories in using this ELISA for the determination of free 25(OH)D. Based on the results of the interlaboratory comparison study, NBL Cambridge and Future Diagnostics were selected to analyze the SRM suite to assign target values for free 25(OH)D using the ELISA.

The NBL Cambridge results for the determination of free 25(OH)D in the 40 single-donor samples are summarized in Table S4. Similar results from the analysis of the same samples by Future Diagnostics are provided in Table S5. These results illustrate the repeatability achievable when using the ELISA. A plot of the free 25(OH)D (NBL Cambridge) concentration versus the NIST Total 25(OH)D in the 40 single-donor samples is shown in Fig. 1, and a similar plot using the Future Diagnostics results for free 25(OH)D is provided in Figure S1 (Supplementary Information).

Fig. 1

Ordinary least squares linear regression for free 25(OH)D and total 25(OH)D in 40 single-donor patient samples. Black circles are the single-donor samples, and the solid red line is the regression line. The red dashed line is the 95% confidence interval for the regression line. Free 25(OH)D measurements performed at NBL Cambridge

Figure image at the original source — open the original paper. This file is not included in this text import.

Comparison and combination of results from two laboratories

Three NIST SRMs with nine different levels were available with values assigned for 25(OH)D2, 25(OH)D3, total 25(OH)D, and VDBP as summarized in Table 1. Total 25(OH)D concentrations for the nine materials range from 18.9 to 40.1 ng/mL, with 25(OH)D3 ranging from 18.1 to 39.4 ng/mL. For the four levels of SRM 1949, values are assigned for VDBP, which increases in concentration from 211.5 μg/mL in the non-pregnant serum pool to 383.4 μg/mL in the third trimester serum pool.

Table 1

National Institute of Standards and Technology (NIST) Standard Reference Materials (SRM®) with vitamin D metabolite assigned values and uncertainty used in this study

SRM samplesSerum vitamin D metabolitea (ng/mL)Vitamin D binding protein (μg/mL)
25(OH)D225(OH)D3Total 25(OH)D
MeanUncertaintyMeanUncertaintyMeanUncertaintyMeanUncertainty
SRM 972a level 10.540.0628.81.129.31.1NRbNR
SRM 972a level 20.810.0618.10.418.90.4NRNR
SRM 972a level 313.20.319.80.433.00.5NRNR
SRM 972a level 40.550.1029.40.930.00.9NRNR
SRM 29730.650.0239.40.840.10.8NRNR
SRM 1949 NPc0.278NR24.980.2825.3dNR211.52.8
SRM 1949 1Tc1.200.0526.010.2227.2dNR286.73.8
SRM 1949 2Tc0.5140.03730.000.5030.5dNR349.74.3
SRM 1949 3Tc0.8970.05729.430.4130.3dNR383.45.1

aCertified values in bold type; reference values in normal type. Uncertainties for certified and reference values are not equivalent; see SRM Certificate of Analysis (COA) for complete description of the uncertainties of certified and reference values. To convert ng/mL to nmol/L, multiply 25(OH)D2 concentration by 2.423 and 25(OH)D3 concentration by 2.496

bNR, not reported

cNP, non-pregnant; 1T, 1st trimester of pregnancy; 2T, 2nd trimester of pregnancy; and 3T, 3rd trimester of pregnancy

dValues calculated for this study and not assigned by NIST on the SRM COA

All nine levels of the SRMs were analyzed to determine the content of free 25(OH)D using the ELISA in two laboratories. The individual results (n = 12 for each SRM level) from the two laboratories for the determination of free 25(OH)D are provided in Table 2. The paired mean differences between NBL Cambridge and Future Diagnostics measurements were small as shown in Table 3. The results from the two laboratories were combined, and the means and standard deviations are summarized in Table 4.

In six of the nine NIST SRM levels, the NBL Cambridge measurements were slightly higher than the Future Diagnostics Solutions measurements. None of the paired differences were statistically significant (p < 0.05) and the 95% confidence limits for the mean difference in every case included zero. A distribution plot of the results from both laboratories for SRM 972 level 3 is shown in Fig. 2. Similar distribution plots for the remaining SRM samples are provided in Figures S2 to S9 in Supplementary Information.

A plot of the least squares regression of the directly measured free 25(OH)D means from the two laboratories is shown in Fig. 3. The regression line with R2 = 0.99 and slope of 0.977 with 95% confidence interval including zero intercept and slope of 1.00 indicate the near perfect correspondence between the two laboratories for the direct measurement of free 25(OH)D. The standardized residual plot for the regression model shown in Figure S10 (Supplementary Information) does not indicate any violation of the regression model assumptions.

Table 2

Individual measurement results from both laboratories for the three SRMs

SRM 972aSRM 2973SRM 1949
Level 1Level 2Level 3Level 4NPa1st2nd3rd
LabbDayRunRepcFree 25(OH)D3 (pg/mL)d
11117.7505.3418.2618.0349.7426.2224.3313.4713.483
11128.1485.1647.3137.5289.8156.1334.6774.5663.681
11216.9664.9918.1918.40110.2636.1713.7713.9863.288
11227.9174.2107.6918.44210.4796.5645.0045.2424.288
12117.5795.8988.8938.32610.3726.2304.9523.4653.972
12127.8415.1867.5387.7009.6786.4375.0874.6683.982
12217.3545.6948.3738.3949.5016.6804.7554.4063.450
12227.8074.9757.9678.4119.8406.3684.9354.8403.847
13118.1435.2088.1878.0389.5356.0014.9874.1044.013
13127.6554.1857.0967.0969.2645.9554.8754.7833.392
13217.7835.0838.0577.7659.8666.1454.8404.0513.577
13229.3854.8478.4857.3839.6316.5324.9484.4403.846
21117.4214.8177.9237.47010.0226.1614.6104.1163.712
21126.8004.4087.1938.0409.6835.7464.4584.3753.826
21218.7045.7888.3028.66510.9956.6675.2165.3604.359
21228.4725.2238.2838.89211.7046.7405.7955.0664.271
22118.1134.7197.2307.6809.2315.9854.4413.8912.750
22127.1683.9607.1687.1169.8865.3974.1084.1013.553
22217.1774.7197.3247.4979.4585.5344.3604.1453.600
22227.0634.3636.7997.3449.6095.5044.3504.4723.955
23118.1815.2318.5258.71610.9046.3714.6854.4973.732
23127.3483.4357.7657.66810.2156.3924.8784.4973.711
23217.5245.0147.8077.70810.1205.6764.6304.3283.785
23227.6434.6167.5457.18910.1345.9504.1614.7794.293

aNon-pregnant, 1st trimester, 2nd trimester, and 3rd trimester

b1, Nutritional Biomarker Laboratory (NBL), Cambridge; and 2, Future Diagnostics Laboratory

cRep, replicate

dTo convert pg/mL to pmol/L, multiply by 2.496

Table 3

Comparison of paired mean directly measured free 25(OH)D

SRMs®University of CambridgeFuture Diagnostics SolutionsCombinedPaired t test
Concentration (pg/mL)95% CL for
MeanSDMeanSDMeanSDMean differenceaMean difference
SRM 972a level 17.860.587.630.607.750.590.23 − 0.35 to 0.81
SRM 972a level 25.060.504.690.624.880.580.37 − 0.08 to 0.83
SRM 972a level 38.000.507.660.547.830.540.34 − 0.12 to 0.81
SRM 972a level 47.960.467.830.617.900.530.13 − 0.26 to 0.52
SRM 29739.830.3710.160.7210.000.58 − 0.33 − 0.77 to 0.11
SRM 1949 NPb6.290.236.010.466.150.380.28 − 0.09 to 0.64
SRM 1949 1Tb4.760.374.640.474.700.420.12 − 0.31 to 0.56
SRM 1949 2Tb4.340.544.470.424.400.48 − 0.13 − 0.48 to 0.21
SRM 1949 3Tb3.740.303.800.433.760.36 − 0.06 − 0.41 to 0.29

aDifference is NBL Cambridge (pg/mL) – Future Diagnostics Solutions (pg/mL)

bNP, non-pregnant; 1T, 1st trimester of pregnancy; 2T, 2nd trimester of pregnancy; and 3T, 3rd trimester of pregnancy

cTo convert pg/mL to pmol/L multiply by 2.496, except for SRM 972a level 3 which has a high concentration of serum 25(OH)D2

Table 4

Summary of percent of free 25(OH)D3 in the SRMs

Free 25(OH)D3 (pg/mL)Total 25(OH)D (ng/mL)Percent free 25(OH)D
MeanSDMeanUncertaintyaPercentbSDb
SRM 972a level 17.750.5929.31.10.02640.0020
SRM 972a level 24.880.5818.90.40.02580.0031
SRM 972a level 37.830.5433.00.50.02370.0016
SRM 972a level 47.900.5330.00.90.02640.0018
SRM 297310.000.5840.10.80.02500.0015
SRM 1949 NPc6.150.3825.3dNRe0.02460.0015
SRM 1949 1Tc4.700.4227.2dNRe0.01810.0016
SRM 1949 2Tc4.400.4830.5dNRe0.01440.0016
SRM 1949 3Tc3.760.3630.3dNRe0.01240.0012

aUncertainty from the NIST SRM COA

bMean of free 25(OH)D from both laboratories/total 25(OH)D NIST × 100; SD, standard deviation of combined measurements from both laboratories

cNP, non-pregnant; 1T, 1st trimester of pregnancy; 2T, 2nd trimester of pregnancy; and 3T, 3rd trimester of pregnancy

dValues calculated [sum of 25(OH)D2 and 25(OH)D3] for this study and not assigned by NIST on the SRM COA

eNR, not reported on COA

Fig. 2

Distribution of free 25(OH)D (pg/mL) measurements by laboratory for NIST SRM 972a — Vitamin D Metabolites in Frozen Human Serum (level 3). Blue diamonds are the individual measurements. Black bar is the mean value of the 12 measurements

Figure image at the original source — open the original paper. This file is not included in this text import.
Fig. 3

Ordinary least squares regression of the means for directly measured free 25(OH)D concentrations by laboratory. The black solid line is the regression line; the dashed blue line is the identity line (y = x); and the red dashed lines are the 95% confidence interval for the regression line

Figure image at the original source — open the original paper. This file is not included in this text import.

The correlation of directly measured free 25(OH)D with the total 25(OH)D content for the nine SRM levels is shown in Fig. 4. The relationship between free 25(OH)D and total 25(OH)D in the three levels in SRM 1949 representing the three pregnancy trimesters is obviously different from the other SRM serum pools as indicated in Fig. 4 (red dots), and the percent free 25(OH)D was lower in pregnancy compared to non-pregnancy samples. This observation may be explained by the higher circulating level of VDBP observed in pregnant compared to non-pregnant women [42–45] in SRM 1949 where VDBP concentration is associated with directly measured free 25(OH)D concentration between non-pregnancy and pregnancy and in the increased VDBP concentration across gestation (Fig. 5) as reported in longitudinal studies during pregnancy [42, 45].

However, Bikle and Swartz [17] suggest that free 25(OH)D may be the same or only slightly lower during pregnancy.

Fig. 4

Least squares linear regression for free 25(OH)D and total 25(OH)D for nine SRM levels. The black dots and black regression line are SRM 972a, SRM 2973, and SRM 1949 (non-pregnant level); the red dots are for SRM 1949 levels representing the 1st, 2nd, and 3rd trimester serum pools, and the red regression line is for all samples. Regression equation and R2 value in black are for SRM 972a, SRM 2973, and SRM 1949 (non-pregnant level); red regression equation and R2 value are for all samples

Figure image at the original source — open the original paper. This file is not included in this text import.
Fig. 5

Least squares linear regression for free 25(OH)D versus vitamin D binding protein for different SRM 1949 levels

Figure image at the original source — open the original paper. This file is not included in this text import.

Use of SRMs for harmonization of measurements

The assignment of target values for free 25(OH)D using the ELISA assay in existing SRMs is an initial step towards harmonization and eventual standardization of measurements of free 25(OH)D. These SRMs are available to any researcher for use as control samples or for assigning target values to in-house control materials. The use of these SRMs for reporting free 25(OH)D concentrations in various studies will allow for comparison of results among different laboratories, different studies, and over time. We recommend that users of the ELISA for free 25(OH)D analyze one or more of the SRMs and compare their results with the target values reported in this paper to determine laboratory/assay performance.

If the results are biased, users should evaluate whether the assay protocol has been appropriately followed. Results among different laboratories, and different studies can be harmonized using approaches as described previously for 25(OH)D assays [46, 47].

The availability of additional information characterizing these existing SRMs for vitamin D metabolites enhances the value of these materials [48]. In particular, the addition of free 25(OH)D results to SRM 1949 provides valuable information on the effect of changes in VDBP concentration on free 25(OH)D in pregnancy. This information may also be relevant to other pathological conditions associated with changes in VDBP concentration [49] and their effect on vitamin D metabolism.

Source: Results and discussion Source: Results and discussion Source: Results and discussion
Authors’ abstract

The majority of circulating 25-hydroxyvitamin D (25(OH)D) is protein bound and perhaps less available than the free fraction of 25(OH)D; therefore, researchers have proposed that the measurement of free 25(OH)D in human serum may be a better indicator of vitamin D health status than total 25(OH)D. The availability of a new enzyme-linked immunosorbent assay (ELISA) for the determination of free 25(OH)D provides a method for direct measurement of the low levels of non-protein bound 25(OH)D. As an initial step towards harmonization of measurements of free 25(OH)D, the ELISA was used to measure free 25(OH)D in three existing Standard Reference Materials (SRMs): SRM 972a Vitamin D Metabolites in Frozen Human Serum, SRM 2973 Vitamin D Metabolites in Frozen Human Serum (High Level), and SRM 1949 Frozen Prenatal Human Serum.

Target values for free 25(OH)D in the nine SRM serum pools, obtained by combining the results from two laboratories, ranged from 3.76 ± 0.36 to 10.0 ± 0.58 pg/mL. Of particular significance is the assignment of free 25(OH)D target values to SRM 1949, which consists of four serum pools from non-pregnant female donors of reproductive age and pregnant women in each of the three trimesters and which also has values assigned for vitamin D binding protein, which increases during pregnancy.

The availability of target values for free 25(OH)D in these SRMs will allow researchers to validate new analytical methods and to compare their results with other researchers as an initial step towards harmonization of measurements among different studies and laboratories.

Supplementary Information

The online version contains supplementary material available at 10.1007/s00216-022-04313-y.

Read the full paper

Introduction

Because of the importance of vitamin D in human health and development, in either the D2 (ergocalciferol) or D3 (cholecalciferol) form, testing for vitamin D in human serum has become routine to diagnose and monitor deficiency. The major circulating form of vitamin D and the primary marker of vitamin D status is 25-hydroxyvitamin D [25(OH)D], which is defined as the sum of 25-hydroxyvitamin D2 [25(OH)D2] and 25-hydroxyvitamin D3 [25(OH)D3]. Measurements of 25(OH)D are typically performed using a ligand binding assay, which responds to both 25(OH)D2 and 25(OH)D3 and thereby provides total 25(OH)D, or using liquid chromatography–tandem mass spectrometry (LC–MS/MS), which measures the 25(OH)D2 and 25(OH)D3 individually.

Recent reviews [1–5] have discussed the challenges and difficulties in assessing vitamin D status, and recent studies [6–11] have demonstrated the variability of results among different 25(OH)D assays.

Like other steroid hormones, circulating 25(OH)D is primarily bound to proteins, with 85% to 90% strongly bound to vitamin D binding protein (VDBP), a specific transport protein for vitamin D; 10% to 15% is loosely bound to serum albumin; and only 0.02% to 0.04% exists in a free, unbound form [12–14]. Recent studies have suggested that the measurement of free 25(OH)D may be a better indicator of vitamin D status than the total 25(OH)D content [14–16], and several reviews have discussed the basis of these conclusions [12, 13, 15, 17, 18].

Methods for the determination of 25(OH)D have been available since the 1970s; however, methods for the determination of free 25(OH)D were first described in the 1980s based on centrifugal ultrafiltration using 3H-labeled 25(OH)D3 and 14C-labeled glucose. However, the method was not used extensively because it is time-consuming and expensive [19, 20]. Using affinity constants determined from centrifugal ultrafiltration measurements, Bikle et al. [19] proposed a calculation method in 1986 to determine free 25(OH)D using the measured total 25(OH)D, VDBP, and albumin concentrations and the estimated affinity constants between 25(OH)D and VDBP and albumin.

In the early 2010s, an enzyme-linked immunosorbent assay (ELISA) was developed [21] and became commercially available for the direct measurement of free 25(OH)D. The ELISA is based on monoclonal anti-25(OH)D antibodies and uses a specific incubation buffer that enables the capture of the free fraction of 25(OH)D only [21]. The ELISA was validated and compared with the dialysis technique using 15 samples with a regression line slope of 0.992 and R2 = 0.737 [21].

This ELISA is currently the only commercially available assay for free 25(OH)D, and it has been used for the direct determination of free 25(OH)D in numerous studies since 2013 as documented in a 2018 review by Tsuprykov et al. [18], where the authors summarized 54 original papers reporting measurements of free 25(OH)D from 1984 to 2017 using either dialysis (4%), calculation (65%), or ELISA (31%) methods. In 2020, Wang et al. [22] reported using a method based on preparation using an ultrafiltration tube, derivatization with PTAD, and finally separation and detection by LC–MS/MS for the assessment of free 25(OH)D.

Based on a vitamin D workshop held in 2016 reported by Bikle et al. [15], a clear need for standardization of measurements of VDBP and free 25(OH)D was identified.

To assist in standardization of measurements of 25(OH)D among laboratories and over time, the Office of Dietary Supplements at the National Institutes of Health (NIH-ODS) organized the Vitamin D Standardization Program (VDSP) in 2010 [23, 24], a collaboration among NIH-ODS, the National Institute of Standards and Technology (NIST), the Centers for Disease Control and Prevention (CDC), and national survey laboratories in several countries. A reference measurement system has been established that includes reference measurement procedures (RMPs) at NIST [25, 26], Ghent University [27], and CDC [28]; NIST Standard Reference Materials® (SRMs) [29–31]; the CDC Vitamin D Standardization – Certification Program (VDSCP) [32]; and collaborations with two accuracy-based proficiency testing/external quality assessment (PT/EQA) programs, i.e., the US College of American Pathologists (CAP) accuracy-based vitamin D (ABVD) program [33] and the UK-based Vitamin D External Quality Assessment Scheme (DEQAS) [34, 35].

In 2009, NIST issued the first frozen serum matrix SRM for the determination of vitamin D metabolites including 25(OH)D2, 25(OH)D3, and 3-epi-25-hydroxyvitamin D3, i.e., SRM 972 Vitamin D in Frozen Human Serum with four serum pools with different levels of the metabolites [29]. When the inventory of SRM 972 was exhausted in 2011, an improved SRM 972a Vitamin D Metabolites in Frozen Human Serum was developed again with four different serum pools representing different levels of metabolites [30].

In 2017, SRM 2973 Vitamin D Metabolites in Frozen Human Serum (High Level) was released consisting of one serum pool with a high level of 25(OH)D3 (39.4 ng/mL) [31]. In addition to the three metabolites with certified values in SRM 972a, SRM 2973 also had values assigned for 24R,25-dihydroxyvitamin D3, and values for this metabolite were also added to SRM 972a at this time. Recently, a unique SRM was produced with serum from female donors of reproductive age who were either not pregnant or pregnant in each of the three trimesters, i.e., SRM 1949 Frozen Prenatal Human Serum [36].

Intended primarily for the determination of thyroid hormones, SRM 1949 also has values assigned for 25(OH)D2, 25(OH)D3, 3-epi-25-hydroxyvitamin D3, and VDBP. These SRMs have found widespread use within the vitamin D testing and research community during the past decade for method development and validation and as control materials for routine testing with over 4500 units distributed to hospital/clinical centers, university, commercial testing, and government laboratories [24].

The components of the reference measurement system for total 25(OH)D as described above follow the recommendations established for harmonization of clinical laboratory measurement procedures [37–40]. However, at present, there is no reference measurement system in place or harmonization efforts underway regarding the measurement of free 25(OH)D. As a first step towards harmonization of measurements of free 25(OH)D, the goal of this study was to determine target values for free 25(OH)D using the ELISA method in existing SRMs used for the determination of vitamin D metabolites.

With the availability of target values for free 25(OH)D in these SRMs, laboratories can use these SRMs as controls to assure the quality of their measurements and to validate new methods for determination of free 25(OH)D.

Experimental

SRMs evaluated

Three NIST SRMs with values assigned for 25(OH)D2, 25(OH)D3, and total 25(OH)D were evaluated for the content of free 25(OH)D. SRM 972a Vitamin D Metabolites in Frozen Human Serum (3 units, 1 vial per level) [30] and 2973 Vitamin D Metabolites in Frozen Human Serum (High Level) (2 units, 2 vials per level) [31] were provided by NIST and shipped on dry ice to the two participating laboratories. SRM 1949 Frozen Human Prenatal Serum (2 units, 2 vials per level) [36] was purchased from NIST and shipped on dry ice to the two participating laboratories.

The SRMs were then stored at − 70 °C at each laboratory until analyzed.

Single-donor samples evaluated and selection of laboratories for the evaluation of SRMs

Prior to this study, an interlaboratory comparison study of the performance of the free 25(OH)D ELISA was conducted among nine laboratories using the ELISA to determine free 25(OH)D. Forty single-donor samples were analyzed from a 50 single-donor sample set used in an earlier interlaboratory comparison exercise for the determination of total 25(OH)D described in Wise et al. [6] with values for total 25(OH)D ranging from 6.5 to 61.1 ng/mL. The results of the analysis of these samples for the determination of 25(OH)D2 and 25(OH)D3 using the NIST reference measurement procedures [25] were reported previously [6].

These 40 samples were analyzed for the determination of free 25(OH)D at the Nutritional Biomarker Laboratory, Medical Research Council (MRC) Epidemiology Unit at the University of Cambridge (Cambridge, UK), using the approach described below. The results from the interlaboratory comparison informed the selection of the laboratories for the evaluation of SRMs in the study reported here.

Directly measured free 25(OH)D procedures

Two laboratories, Future Diagnostics (Wijchen, The Netherlands) and Nutritional Biomarker Laboratory (NBL), MRC Epidemiology Unit at the University of Cambridge (Cambridge, UK), analyzed the SRM samples using the DIAsource Free 25OH Vitamin D ELISA assay. The SRM samples were run on each of 3 days with two runs per day and two replicates per run (i.e., 3 days × 2 runs/day × 2 replicates per run = 12 determinations per each level of each SRM). Only one SRM vial was used per day to avoid any potential freeze/thaw stability concerns.

The free 25(OH)D ELISA is based on a two-step immunoassay performed in a microtiter plate. During the first step, free 25(OH)D2 and 25(OH)D3 bind with the anti-vitamin D antibody coated on the bottom of the microtiter plate wells. After washing, a fixed amount of biotinylated 25(OH)D is added to each well to react with the unoccupied antibody binding sites. After washing to remove unbound biotinylated 25(OH)D, streptavidin–peroxidase conjugate is added, and the bound enzyme is quantified colorimetrically [21].

Both laboratories followed the manufacturer’s instructions [21] for measurement of free 25(OH)D using the DIAsource assay. DIAsource Free 25OH Vitamin D ELISA assay short instructions are as follows (KAPF1991, DiaSource ImmunoAssays S.A., Louvain-la Neuve, BE). Add 90 μL sample diluent to the wells. Transfer 10 μL calibrator, control, or sample in duplicate into the appropriate well of the microtiterplate. Incubate the plate for 90 min at 37 °C while shaking at 650 rpm. Wash the plate 3 times with wash buffer.

Add 100 μL Biot-VitD reagent to the wells. Incubate the plate for 30 min at 37 °C while shaking at 650 rpm. Wash the plate 3 times with wash buffer. Add 100 μL streptavidin-HRP reagent to the wells. Incubate the plate for 20 min at 37 °C while shaking at 650 rpm. Wash the plate 3 times with wash buffer. Add 100 μL substrate reagent to the wells. Incubate the plate for 15 min at room temperature while stationary and protected from light.

Add 100 μL stop reagent to each well. Read the plate at 450 nm within 5 min. The information regarding instruments, calibrators, and instrument controls used by both laboratories are provided in Tables S1, S2, and S3 (Supplementary Information), respectively, and are described briefly below.

Nutritional Biomarker Laboratory (NBL), University of Cambridge

The free 25(OH)D ELISA was performed according to the manufacturer’s instructions by a single analyst. Incubation and shaking were performed with a BMG THERMOstar (BMG Labtech Ltd., UK) and washing with a Thermo Wellwash (Thermo Fisher Scientific, UK). Results were read using a Thermo Multiskan (Thermo Fisher Scientific, UK).

Future Diagnostics

The free 25(OH)D ELISA was performed according to the manufacturer’s instruction by three different analysts. A Thermo iEMS shaker incubator (Thermo Scientific, USA) was used for the incubation, washing was done using a Biotek elx50, and absorption values were measured using a Biotek elx800 plate reader (Biotek, USA).

Statistical methods

All data analyses were conducted using CBStat 5.1 (Copyright by Kristian Linnet, Ordup Have 15, DK-2920 Charlottenlund, Denmark). Paired t test was used to test for significant differences between Future Diagnostics and NBL Cambridge determinations for day, run, and duplicate. Mean paired difference over day, run, and duplicate was calculated as the NBL Cambridge determination minus the Future Diagnostics determination. Ordinary least squares regression analysis was used to compare mean values for each SRM level (n = 9).

Results and discussion

Interlaboratory comparison and selection of laboratories for the evaluation of SRMs

For the interlaboratory comparison study conducted among nine laboratories using the ELISA to determine free 25(OH)D in a set of 40 single-donor samples [41], overall %CVs for the individual laboratories ranged from 2.8 to 22% with only the assay manufacturer laboratory (Future Diagnostics) and NBL Cambridge achieving %CVs below 4%. The results obtained by Future Diagnostics were considered to be the benchmark, and bias compared to the Future Diagnostics results ranged from 1.3 to 29% with only two laboratories achieving a bias below 5% [41].

The results of this interlaboratory study indicated a need for improvement among laboratories in using this ELISA for the determination of free 25(OH)D. Based on the results of the interlaboratory comparison study, NBL Cambridge and Future Diagnostics were selected to analyze the SRM suite to assign target values for free 25(OH)D using the ELISA.

The NBL Cambridge results for the determination of free 25(OH)D in the 40 single-donor samples are summarized in Table S4. Similar results from the analysis of the same samples by Future Diagnostics are provided in Table S5. These results illustrate the repeatability achievable when using the ELISA. A plot of the free 25(OH)D (NBL Cambridge) concentration versus the NIST Total 25(OH)D in the 40 single-donor samples is shown in Fig. 1, and a similar plot using the Future Diagnostics results for free 25(OH)D is provided in Figure S1 (Supplementary Information).

Fig. 1

Ordinary least squares linear regression for free 25(OH)D and total 25(OH)D in 40 single-donor patient samples. Black circles are the single-donor samples, and the solid red line is the regression line. The red dashed line is the 95% confidence interval for the regression line. Free 25(OH)D measurements performed at NBL Cambridge

Figure image at the original source — open the original paper. This file is not included in this text import.

Comparison and combination of results from two laboratories

Three NIST SRMs with nine different levels were available with values assigned for 25(OH)D2, 25(OH)D3, total 25(OH)D, and VDBP as summarized in Table 1. Total 25(OH)D concentrations for the nine materials range from 18.9 to 40.1 ng/mL, with 25(OH)D3 ranging from 18.1 to 39.4 ng/mL. For the four levels of SRM 1949, values are assigned for VDBP, which increases in concentration from 211.5 μg/mL in the non-pregnant serum pool to 383.4 μg/mL in the third trimester serum pool.

Table 1

National Institute of Standards and Technology (NIST) Standard Reference Materials (SRM®) with vitamin D metabolite assigned values and uncertainty used in this study

SRM samplesSerum vitamin D metabolitea (ng/mL)Vitamin D binding protein (μg/mL)
25(OH)D225(OH)D3Total 25(OH)D
MeanUncertaintyMeanUncertaintyMeanUncertaintyMeanUncertainty
SRM 972a level 10.540.0628.81.129.31.1NRbNR
SRM 972a level 20.810.0618.10.418.90.4NRNR
SRM 972a level 313.20.319.80.433.00.5NRNR
SRM 972a level 40.550.1029.40.930.00.9NRNR
SRM 29730.650.0239.40.840.10.8NRNR
SRM 1949 NPc0.278NR24.980.2825.3dNR211.52.8
SRM 1949 1Tc1.200.0526.010.2227.2dNR286.73.8
SRM 1949 2Tc0.5140.03730.000.5030.5dNR349.74.3
SRM 1949 3Tc0.8970.05729.430.4130.3dNR383.45.1

aCertified values in bold type; reference values in normal type. Uncertainties for certified and reference values are not equivalent; see SRM Certificate of Analysis (COA) for complete description of the uncertainties of certified and reference values. To convert ng/mL to nmol/L, multiply 25(OH)D2 concentration by 2.423 and 25(OH)D3 concentration by 2.496

bNR, not reported

cNP, non-pregnant; 1T, 1st trimester of pregnancy; 2T, 2nd trimester of pregnancy; and 3T, 3rd trimester of pregnancy

dValues calculated for this study and not assigned by NIST on the SRM COA

All nine levels of the SRMs were analyzed to determine the content of free 25(OH)D using the ELISA in two laboratories. The individual results (n = 12 for each SRM level) from the two laboratories for the determination of free 25(OH)D are provided in Table 2. The paired mean differences between NBL Cambridge and Future Diagnostics measurements were small as shown in Table 3. The results from the two laboratories were combined, and the means and standard deviations are summarized in Table 4.

In six of the nine NIST SRM levels, the NBL Cambridge measurements were slightly higher than the Future Diagnostics Solutions measurements. None of the paired differences were statistically significant (p < 0.05) and the 95% confidence limits for the mean difference in every case included zero. A distribution plot of the results from both laboratories for SRM 972 level 3 is shown in Fig. 2. Similar distribution plots for the remaining SRM samples are provided in Figures S2 to S9 in Supplementary Information.

A plot of the least squares regression of the directly measured free 25(OH)D means from the two laboratories is shown in Fig. 3. The regression line with R2 = 0.99 and slope of 0.977 with 95% confidence interval including zero intercept and slope of 1.00 indicate the near perfect correspondence between the two laboratories for the direct measurement of free 25(OH)D. The standardized residual plot for the regression model shown in Figure S10 (Supplementary Information) does not indicate any violation of the regression model assumptions.

Table 2

Individual measurement results from both laboratories for the three SRMs

SRM 972aSRM 2973SRM 1949
Level 1Level 2Level 3Level 4NPa1st2nd3rd
LabbDayRunRepcFree 25(OH)D3 (pg/mL)d
11117.7505.3418.2618.0349.7426.2224.3313.4713.483
11128.1485.1647.3137.5289.8156.1334.6774.5663.681
11216.9664.9918.1918.40110.2636.1713.7713.9863.288
11227.9174.2107.6918.44210.4796.5645.0045.2424.288
12117.5795.8988.8938.32610.3726.2304.9523.4653.972
12127.8415.1867.5387.7009.6786.4375.0874.6683.982
12217.3545.6948.3738.3949.5016.6804.7554.4063.450
12227.8074.9757.9678.4119.8406.3684.9354.8403.847
13118.1435.2088.1878.0389.5356.0014.9874.1044.013
13127.6554.1857.0967.0969.2645.9554.8754.7833.392
13217.7835.0838.0577.7659.8666.1454.8404.0513.577
13229.3854.8478.4857.3839.6316.5324.9484.4403.846
21117.4214.8177.9237.47010.0226.1614.6104.1163.712
21126.8004.4087.1938.0409.6835.7464.4584.3753.826
21218.7045.7888.3028.66510.9956.6675.2165.3604.359
21228.4725.2238.2838.89211.7046.7405.7955.0664.271
22118.1134.7197.2307.6809.2315.9854.4413.8912.750
22127.1683.9607.1687.1169.8865.3974.1084.1013.553
22217.1774.7197.3247.4979.4585.5344.3604.1453.600
22227.0634.3636.7997.3449.6095.5044.3504.4723.955
23118.1815.2318.5258.71610.9046.3714.6854.4973.732
23127.3483.4357.7657.66810.2156.3924.8784.4973.711
23217.5245.0147.8077.70810.1205.6764.6304.3283.785
23227.6434.6167.5457.18910.1345.9504.1614.7794.293

aNon-pregnant, 1st trimester, 2nd trimester, and 3rd trimester

b1, Nutritional Biomarker Laboratory (NBL), Cambridge; and 2, Future Diagnostics Laboratory

cRep, replicate

dTo convert pg/mL to pmol/L, multiply by 2.496

Table 3

Comparison of paired mean directly measured free 25(OH)D

SRMs®University of CambridgeFuture Diagnostics SolutionsCombinedPaired t test
Concentration (pg/mL)95% CL for
MeanSDMeanSDMeanSDMean differenceaMean difference
SRM 972a level 17.860.587.630.607.750.590.23 − 0.35 to 0.81
SRM 972a level 25.060.504.690.624.880.580.37 − 0.08 to 0.83
SRM 972a level 38.000.507.660.547.830.540.34 − 0.12 to 0.81
SRM 972a level 47.960.467.830.617.900.530.13 − 0.26 to 0.52
SRM 29739.830.3710.160.7210.000.58 − 0.33 − 0.77 to 0.11
SRM 1949 NPb6.290.236.010.466.150.380.28 − 0.09 to 0.64
SRM 1949 1Tb4.760.374.640.474.700.420.12 − 0.31 to 0.56
SRM 1949 2Tb4.340.544.470.424.400.48 − 0.13 − 0.48 to 0.21
SRM 1949 3Tb3.740.303.800.433.760.36 − 0.06 − 0.41 to 0.29

aDifference is NBL Cambridge (pg/mL) – Future Diagnostics Solutions (pg/mL)

bNP, non-pregnant; 1T, 1st trimester of pregnancy; 2T, 2nd trimester of pregnancy; and 3T, 3rd trimester of pregnancy

cTo convert pg/mL to pmol/L multiply by 2.496, except for SRM 972a level 3 which has a high concentration of serum 25(OH)D2

Table 4

Summary of percent of free 25(OH)D3 in the SRMs

Free 25(OH)D3 (pg/mL)Total 25(OH)D (ng/mL)Percent free 25(OH)D
MeanSDMeanUncertaintyaPercentbSDb
SRM 972a level 17.750.5929.31.10.02640.0020
SRM 972a level 24.880.5818.90.40.02580.0031
SRM 972a level 37.830.5433.00.50.02370.0016
SRM 972a level 47.900.5330.00.90.02640.0018
SRM 297310.000.5840.10.80.02500.0015
SRM 1949 NPc6.150.3825.3dNRe0.02460.0015
SRM 1949 1Tc4.700.4227.2dNRe0.01810.0016
SRM 1949 2Tc4.400.4830.5dNRe0.01440.0016
SRM 1949 3Tc3.760.3630.3dNRe0.01240.0012

aUncertainty from the NIST SRM COA

bMean of free 25(OH)D from both laboratories/total 25(OH)D NIST × 100; SD, standard deviation of combined measurements from both laboratories

cNP, non-pregnant; 1T, 1st trimester of pregnancy; 2T, 2nd trimester of pregnancy; and 3T, 3rd trimester of pregnancy

dValues calculated [sum of 25(OH)D2 and 25(OH)D3] for this study and not assigned by NIST on the SRM COA

eNR, not reported on COA

Fig. 2

Distribution of free 25(OH)D (pg/mL) measurements by laboratory for NIST SRM 972a — Vitamin D Metabolites in Frozen Human Serum (level 3). Blue diamonds are the individual measurements. Black bar is the mean value of the 12 measurements

Figure image at the original source — open the original paper. This file is not included in this text import.
Fig. 3

Ordinary least squares regression of the means for directly measured free 25(OH)D concentrations by laboratory. The black solid line is the regression line; the dashed blue line is the identity line (y = x); and the red dashed lines are the 95% confidence interval for the regression line

Figure image at the original source — open the original paper. This file is not included in this text import.

The correlation of directly measured free 25(OH)D with the total 25(OH)D content for the nine SRM levels is shown in Fig. 4. The relationship between free 25(OH)D and total 25(OH)D in the three levels in SRM 1949 representing the three pregnancy trimesters is obviously different from the other SRM serum pools as indicated in Fig. 4 (red dots), and the percent free 25(OH)D was lower in pregnancy compared to non-pregnancy samples. This observation may be explained by the higher circulating level of VDBP observed in pregnant compared to non-pregnant women [42–45] in SRM 1949 where VDBP concentration is associated with directly measured free 25(OH)D concentration between non-pregnancy and pregnancy and in the increased VDBP concentration across gestation (Fig. 5) as reported in longitudinal studies during pregnancy [42, 45].

However, Bikle and Swartz [17] suggest that free 25(OH)D may be the same or only slightly lower during pregnancy.

Fig. 4

Least squares linear regression for free 25(OH)D and total 25(OH)D for nine SRM levels. The black dots and black regression line are SRM 972a, SRM 2973, and SRM 1949 (non-pregnant level); the red dots are for SRM 1949 levels representing the 1st, 2nd, and 3rd trimester serum pools, and the red regression line is for all samples. Regression equation and R2 value in black are for SRM 972a, SRM 2973, and SRM 1949 (non-pregnant level); red regression equation and R2 value are for all samples

Figure image at the original source — open the original paper. This file is not included in this text import.
Fig. 5

Least squares linear regression for free 25(OH)D versus vitamin D binding protein for different SRM 1949 levels

Figure image at the original source — open the original paper. This file is not included in this text import.

Use of SRMs for harmonization of measurements

The assignment of target values for free 25(OH)D using the ELISA assay in existing SRMs is an initial step towards harmonization and eventual standardization of measurements of free 25(OH)D. These SRMs are available to any researcher for use as control samples or for assigning target values to in-house control materials. The use of these SRMs for reporting free 25(OH)D concentrations in various studies will allow for comparison of results among different laboratories, different studies, and over time. We recommend that users of the ELISA for free 25(OH)D analyze one or more of the SRMs and compare their results with the target values reported in this paper to determine laboratory/assay performance.

If the results are biased, users should evaluate whether the assay protocol has been appropriately followed. Results among different laboratories, and different studies can be harmonized using approaches as described previously for 25(OH)D assays [46, 47].

The availability of additional information characterizing these existing SRMs for vitamin D metabolites enhances the value of these materials [48]. In particular, the addition of free 25(OH)D results to SRM 1949 provides valuable information on the effect of changes in VDBP concentration on free 25(OH)D in pregnancy. This information may also be relevant to other pathological conditions associated with changes in VDBP concentration [49] and their effect on vitamin D metabolism.

Supplementary Information

Below is the link to the electronic supplementary material.

Supplementary file1 (DOCX 297 KB)

Supplement file at the original source — open the original paper. This file is not included in this text import.

Publisher's note

Springer Nature remains neutral with regard to jurisdictional claims in published maps and institutional affiliations.

Acknowledgements

The authors acknowledge Johanna E. Camara (NIST) for her assistance in the planning of the study and for providing SRM 972a and SRM 2973 for use in the study and Adam J. Kuszak (NIH-ODS) and the NIH-ODS Analytical Methods and Reference Materials (AMRM) Program for supporting the development of reference materials for vitamin D measurements.

Funding

KSJ and DAP are supported by the National Institute for Health Research (NIHR) Cambridge Biomedical Research Centre (IS-BRC-1215–20014). The views expressed are those of the authors and not necessarily those of the NHS, the NIHR, or the UK Department of Health and Social Care.

Declarations

Competing interests

S. A. Wise is an Editor of the journal Analytical and Bioanalytical Chemistry and was not involved in peer reviewing of this manuscript. Several coauthors are employees of the company that produces the assay kit used in this study. There are no financial or nonfinancial competing interests for any of the coauthors.

References

1. Alexandridou A, Schorr P, Stokes CS, Volmer DA. Analysis of vitamin D metabolic markers by mass spectrometry: recent progress regarding the "gold standard" method and integration into clinical practice. Mass Spectrom Rev. 2021;1–41. 10.1002/mas.21768 34967037
2. Altieri B Cavalier E Bhattoa HP Perez-Lopez FR Lopez-Baena MT Perez-Roncero GR Vitamin D testing: advantages and limits of the current assays Eur J Clin Nutr 2020 74 2 231 247 10.1038/s41430-019-0553-3 31907366
3. Makris K Sempos C Cavalier E The measurement of vitamin D metabolites: part I-metabolism of vitamin D and the measurement of 25-hydroxyvitamin D Horm-Int J Endocrinol Metab 2020 19 2 81 96 10.1007/s42000-019-00169-7 31919677
4. Makris K Sempos C Cavalier E The measurement of vitamin D metabolites part II-the measurement of the various vitamin D metabolites Horm-Int J Endocrinol Metab 2020 19 2 97 107 10.1007/s42000-020-00188-9 32221839
5. Sempos CT Binkley N 25-Hydroxvitamin D assay standardization and vitamin D guidelines paralysis Public Health Nutr 2020 23 7 1153 1164 10.1017/S1368980019005251 32301688 PMC7167380
6. Wise SA Camara JE Sempos CT Burdette CQ Hahm G Nalin F Interlaboratory comparison of 25-hydroxyvitamin D assays: Vitamin D Standardization Program (VDSP) intercomparison study 2 – part 1 liquid chromatography – tandem mass spectrometry (LC-MS/MS) assays – impact of 3-epi-25-hydroxyvitamin D3 on assay performance Anal Bioanal Chem 2022 414 333 349 10.1007/s00216-021-03576-1 34432104
7. Wise SA Camara JE Sempos CT Burdette CQ Hahm G Nalin F Interlaboratory comparison of 25-hydroxyvitamin D assays: Vitamin D Standardization Program (VDSP) intercomparison study 2 - part 2 ligand binding assays – impact of 25-hydroxyvitamin D2 and 24R,25-dihydroxyvitamin D3 on assay performance Anal Bioanal Chem 2022 414 351 366 10.1007/s00216-021-03577-0 34435207 PMC8748290
8. Wise SA Camara JE Sempos CT Lukas P Le Goff C Peeters S Vitamin D Standardization Program (VDSP) Intralaboratory study for the assessment of 25-hydroxyvitamin D assay performance J Steroid Biochem Mol Biol 2021 212 105917 10.1016/j.jsbmb.2021.105917 34010687 PMC8403635
9. Elsenberg E ten Boekel E Huijgen H Heijboer AC Standardization of automated 25-hydroxyvitamin D assays: how successful is it? Clin Biochem 2017 50 18 1126 1130 10.1016/j.clinbiochem.2017.06.011 28668468
10. Garnett E Li JL Rajapakshe D Tam E Meng QH Devaraj S Efficacy of two vitamin D immunoassays to detect 25-OH vitamin D2 and D3 Pract Lab Med 2019 17 4 10.1016/j.plabm.2019.e00130 PMC6695248 31428669
11. Bjerg LN Halgreen JR Hansen SH Morris HA Jorgensen NR An evaluation of total 25-hydroxyvitamin D assay standardization: where are we today? J Steroid Biochem Mol Biol 2019 190 224 233 10.1016/j.jsbmb.2019.03.015 30940597
12. Bikle DD Malmstroem S Schwartz J Current controversies are free vitamin metabolite levels a more accurate assessment of vitamin d status than total levels? Endocrinol Metabol Clin North Amer 2017 46 4 901 918 10.1016/j.ecl.2017.07.013 PMC5675107 29080642
13. Heureux N. Vitamin D testing-where are we and what is on the horizon? In: Makowski GS, editor. Advances in Clinical Chemistry, Vol 78. Advances in Clinical Chemistry. 78. San Diego: Elsevier Academic Press Inc. 2017; p. 59–101. 10.1016/bs.acc.2016.07.002 28057189
14. Tsuprykov O Buse C Skoblo R Hocher B Comparison of free and total 25-hydroxyvitamin D in normal human pregnancy J Steroid Biochem Mol Biol 2019 190 29 36 10.1016/j.jsbmb.2019.03.008 30904637
15. Bikle D Bouillon R Thadhani R Schoenmakers I Vitamin D metabolites in captivity? Should we measure free or total 25(OH)D to assess vitamin D status? J Steroid Biochem Mol Biol 2017 173 105 116 10.1016/j.jsbmb.2017.01.007 28093353 PMC9005158
16. Tsuprykov O Elitok S Buse C Chu C Kramer BK Hocher B Opposite correlation of 25-hydroxy-vitamin D- and 1,25-dihydroxy-vitamin D-metabolites with gestational age, bone- and lipid-biomarkers in pregnant women Sci Rep 2021 11 1 10 10.1038/s41598-021-81452-9 33479299 PMC7820257
17. Bikle DD Schwartz J Vitamin D binding protein, total and free vitamin D levels in different physiological and pathophysiological conditions Front Endocrinol 2019 10 12 10.3389/fendo.2019.00317 PMC6546814 31191450
18. Tsuprykov O Chen X Hocher CF Skoblo R Yin LH Hocher B Why should we measure free 25(OH) vitamin D? J Steroid Biochem Mol Biol 2018 180 87 104 10.1016/j.jsbmb.2017.11.014 29217467
19. Bikle DD Gee E Halloran B Kowalski MA Ryzen E Haddad JG Assessment of the free fraction of 25-hydroxyvitamin-D in serum and its regulation by albumin and the vitamin-D-binding protein J Clin Endocrinol Metab 1986 63 4 954 959 10.1210/jcem-63-4-954 3745408
20. Bikle DD Halloran BP Gee E Ryzen E Haddad JG Free 25-hydroxyvitamin-D levels are normal in subjects with liver-disease and reduced total 25-hydroxyvitamin-D levels J Clin Invest 1986 78 3 748 752 10.1172/JCI112636 3745436 PMC423667
21. Heureux N Lindhout E Swinkels L A direct assay for measuring free 25-hydroxyvitamin D J AOAC Int 2017 100 5 1318 1322 10.5740/jaoacint.17-0084 28492143
22. Wang DC Yu SL Zou YT Zhang YY Qiu L Chen LM Distribution of free 25OHD in elderly population based on LC-MS/MS J Steroid Biochem Mol Biol 2020 200 5 10.1016/j.jsbmb.2020.105672 32311429
23. Sempos CT Vesper HW Phinney KW Thienpont LM Coates PM VDSP. Vitamin D status as an international issue: national surveys and the problem of standardization Scand J Clin Lab Invest 2012 72 32 40 10.3109/00365513.2012.681935 [link unavailable; original address: https://doi.org/10.3109/00365513.2012.681935] 22536760
24. Wise SA Tai SSC Burdette CQ Camara JE Bedner M Lippa KA Role of the National Institute of Standards and Technology (NIST) in support of the vitamin D initiative of the National Institutes of Health, Office of Dietary Supplements J AOAC Int 2017 100 5 1260 1276 10.5740/jaoacint.17-0305 28863788
25. Tai SSC Bedner M Phinney KW Development of a candidate reference measurement procedure for the determination of 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry Anal Chem 2010 82 5 1942 1948 10.1021/ac9026862 20136128 PMC2838390
26. Tai SSC Nelson MA Candidate reference measurement procedure for the determination of (24R),25-dihydroxyvitamin D3 in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry Anal Chem 2015 87 15 7964 7970 10.1021/acs.analchem.5b01861 26171884
27. Stepman HCM Vanderroost A Van Uytfanghe K Thienpont LM Candidate reference measurement procedures for serum 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 by using isotope-dilution liquid chromatography-tandem mass spectrometry Clin Chem 2011 57 3 441 448 10.1373/clinchem.2010.152553 21248072
28. Mineva EM Schleicher RL Chaudhary-Webb M Maw KL Botelho JC Vesper HW A candidate reference measurement procedure for quantifying serum concentrations of 25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 using isotope-dilution liquid chromatography-tandem mass spectrometry Anal Bioanal Chem 2015 407 19 5615 5624 10.1007/s00216-015-8733-z 25967149 PMC4823009
29. Phinney KW Bedner M Tai SSC Vamathevan VV Sander LC Sharpless KE Development and certification of a Standard Reference Material for vitamin D metabolites in human serum Anal Chem 2012 84 2 956 962 10.1021/ac202047n 22141317 PMC3287345
30. Phinney KW Tai SSC Bedner M Camara JE Chia RRC Sander LC Development of an improved Standard Reference Material for vitamin D metabolites in human serum Anal Chem 2017 89 9 4907 4913 10.1021/acs.analchem.6b05168 28375002 PMC5575745
31. Tai SSC Nelson MA Bedner M Lang BE Phinney KW Sander LC Development of Standard Reference Material (SRM) 2973 vitamin D metabolites in frozen human serum (high level) J AOAC Int 2017 100 5 1294 1303 10.5740/jaoacint.17-0182 28917261
32. CDC. Vitamin D Standardization — Certification Program https://www.cdc.gov/labstandards/vdscp.html [link unavailable] Centers for Disease Control and Prevention. Accessed 8 Sept 2022.
33. Erdman P Palmer-Toy DE Horowitz G Hoofnagle A Accuracy-based vitamin D survey six years of quality improvement guided by proficiency testing Arch Pathol Lab Med 2019 143 12 1531 1538 10.5858/arpa.2018-0625-CP 31116045
34. Carter GD Berry J Durazo-Arvizu R Gunter E Jones G Jones J Hydroxyvitamin D assays: an historical perspective from DEQAS J Steroid Biochem Mol Biol 2018 177 30 35 10.1016/j.jsbmb.2017.07.018 28734989
35. Burdette CQ Camara JE Nalin F Pritchett J Sander LC Carter GD Establishing an accuracy basis for the Vitamin D External Quality Assessment Scheme (DEQAS) J AOAC Int 2017 100 5 1277 1287 10.5740/jaoacint.17-0306 28847346
36. Boggs ASP Kilpatrick LE Burdette CQ Tevis DS Fultz ZA Nelson MA Development of a pregnancy-specific reference material for thyroid biomarkers, vitamin D, and nutritional trace elements in serum Clin Chem Lab Med 2021 59 4 671 679 10.1515/cclm-2020-0977 33098630 PMC9972198
37. Miller WG Myers GL Gantzer ML Kahn SE Schonbrunner ER Thienpont LM Roadmap for harmonization of clinical laboratory measurement procedures Clin Chem 2011 57 8 1108 1117 10.1373/clinchem.2011.164012 21677092
38. Myers GL Miller WG Challenge to coordinate harmonization activities on an international level Clin Chem 2017 63 9 1429 1430 10.1373/clinchem.2017.275669 28684553
39. Myers GL Miller WG The roadmap for harmonization: status of the International Consortium for Harmonization of Clinical Laboratory Results Clin Chem Lab Med 2018 56 10 1667 1672 10.1515/cclm-2017-0907 29672262
40 Thienpont LM Van uytfanghe K, De Leenheer AP. Reference measurement systems in clinical chemistry Clin Chim Acta 2002 323 1–2 73 87 10.1016/S0009-8981(02)00188-2 12135808
41. Sempos C, Bouillon R, Billen J, Gross M, Whitake J, Carlson H, et al. Interlaboratory comparison study of Future Diagnostics kit for the direct measurement of free 25OHD. 22nd Vitamin D Workshop, Poster Session I, Board 44, Thursday May 30, 2019, New York.
42. Best CM Pressman EK Queenan RA Cooper E O'Brien KO Longitudinal changes in serum vitamin D binding protein and free 25-hydroxyvitamin D in a multiracial cohort of pregnant adolescents J Steroid Biochem Mol Biol 2019 186 79 88 10.1016/j.jsbmb.2018.09.019 30278215 PMC6611677
43. Jones KS Assar S Prentice A Schoenmakers I Vitamin D expenditure is not altered in pregnancy and lactation despite changes in vitamin D metabolite concentrations Sci Rep 2016 6 26795 10.1038/srep26795 27222109 PMC4879580
44. Tsuprykov O Buse C Skoblo R Hocher B Free 25 (OH) vitamin D, but not total 25 (OH) vitamin D, is strongly correlated with gestational age and calcium in normal human pregnancy J Bone Miner Res 2017 32 S323
45. Zhang JY Lucey AJ Horgan R Kenny LC Kiely M Impact of pregnancy on vitamin D status: a longitudinal study Br J Nutr 2014 112 7 1081 1087 10.1017/S0007114514001883 25159824
46. Durazo-Arvizu RA Tian L Brooks SPJ Sarafin K Cashman KD Kiely M The Vitamin D Standardization Program (VDSP) manual for retrospective laboratory standardization of serum 25-hydroxyvitamin D data J AOAC Int 2017 100 5 1234 1243 10.5740/jaoacint.17-0196 28718397
47. Sempos CT Betz JM Camara JE Carter GD Cavalier E Clarke MW General steps to standardize the laboratory measurement of serum total 25-hydroxyvitamin D J AOAC Int 2017 100 5 1230 1233 10.5740/jaoacint.17-0259 28766476
48. Wise SA. What if using certified reference materials (CRMs) was a requirement to publish in analytical/bioanalytical chemistry journals? Anal Bioanal Chem. 2022, in press. 10.1007/s00216-022-04163-8 35697811
49. Schoenmakers I, Fraser WD, Forbes A. Vitamin D and acute and severe illness - a mechanistic and pharmacokinetic perspective. Nutr Res Rev. 2021;1–16 10.1017/S0954422421000251 34369338
Publication and source details

Original title: Towards harmonization of directly measured free 25-hydroxyvitamin D using an enzyme-linked immunosorbent assay

Christopher T. Sempos; Ernst Lindhout; Nicolas Heureux; Michel Hars; Damon A. Parkington; Emily Dennison; Ramón Durazo-Arvizu; Kerry S. Jones; Stephen A. Wise

Analytical and Bioanalytical Chemistry · 2022

© The Author(s) 2022https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-11T08:42:37.425349+00:00

DOI: 10.1007/s00216-022-04313-y · PMC9568476