Vitamin D3 for Life. Live Enlightened.

Research libraryVitamin D3 For Life
Study design and methods

Primary relevance to vitamin D Vitamin D is a stated subject of this paper.

Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.

Why this paper is included

Supporting source evidence:

The Waters Quattro PremierTM/XE method was linear for 25(OH)D3, 25(OH)D2, and 3-Epi25(OH)D3 as shown in Table 1, and the best fits were indicated by a correlation coefficient (r) of 0.99 for 25(OH)D3, 25(OH)D2, and 3-Epi25(OH)D3.

Source: 3.1. Evaluation of the LC-MS/MS Assay. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Secondary analysis.

Secondary analysis

Analyses existing study data; this paper is not automatically another independent trial.

Meta-analysis unclear · Blinding unclear / not reported · Human research reported

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

From January 2016 until February 2017, pregnant women were recruited to participate in a two-armed randomized controlled intervention trial involving cod intake in pregnancy [].

Source: Methods.

A total of 137 pregnant women were included in this secondary analysis.

Source: Methods.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Full studies

Validation and Determination of 25(OH) Vitamin D and 3-Epi25(OH)D3 in Breastmilk and Maternal- and Infant Plasma during Breastfeeding

Secondary analysis · Nutrients · 2020

Original publication title

Validation and Determination of 25(OH) Vitamin D and 3-Epi25(OH)D3 in Breastmilk and Maternal- and Infant Plasma during Breastfeeding

Jennifer Gjerde; Marian Kjellevold; Lisbeth Dahl; Torill Berg; Annbjørg Bøkevoll; Maria Wik Markhus

© 2020 by the authors.

Original publication · Publisher record · CC BY 4.0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

At a glance

Study background

What background does the paper provide?

Vitamin D plays an important role in bone metabolism. It regulates the calcium and phosphate in the body, making it important for muscle, tooth, and growth development [1]. It may also play an important role in immune system regulation [2,3]. The source of vitamin D in Norwegian diets is in the form of vitamin D2 (ergocalciferol) from plants and vitamin D3 (cholecalciferol) from fish, butter, and eggs [4]. Vitamin D2 and D3 bind to the Vitamin D carrier protein (DBP) before transported to the liver for hydroxylation, producing 25-hydroxyvitamin (25(OH)) D3 and 25(OH)D2.

The 25(OH)D2 is derived solely from the diet/supplements and 25(OH)D3 is either derived from the diet/supplements or synthesized in the skin. The C3 epimer forms of vitamin D3 have less affinity toward vitamin D protein and even lower affinity for vitamin D receptors compared to 25(OH)D3. The 3-Epi25(OH)D3 binds to vitamin D receptor (VDR) at 2–3% the affinity of 25(OH)D3 [5]. Studies have also shown reduced ability in inducing calcium transport and reduced gene expression in the human colonic carcinoma cell line, Caco-2 [6,7,8].

Determining the concentration of 25(OH)D3 and 3-Epi25(OH)D3 separately is therefore important due to possible difference of effectiveness. However, further studies on the function and source of 3-Epi25(OH)D3 in humans are warranted.

Vitamin D3 has a plasma half-life of 4 to 12 h [9,10] and a circulating half-life of 12 to 24 h [11]. On the other hand, 25(OH)D2 and 25(OH)D3 have longer half-lives, 13 and 15 to 25 days, respectively [12,13,14,15]. The 25(OH)D is further hydroxylated to 1,25-dihydroxyvitamin D (1,25(OH)2D), the most potent physiologically active metabolite with a relatively short half-life of 4 to 6 h [16].

This suggests that measurements of 25(OH)D, 25(OH)D2, and 25(OH)D3 are better indicators of vitamin D status in the blood. Holick et al. have published a set of guidelines for the evaluation of Vitamin D deficiencies [17]. Blood 25(OH)D levels < 50 nmol/L are considered 25(OH)D-deficient, levels between 50 and 75 nmol/L are considered 25(OH)D-insufficient, and >75 nmol/L are considered 25(OH)D-sufficient [17,18,19,20].

Methods which only measure 25(OH)D3 and not 3-Epi25(OH)D3 may cause overestimation of 25(OH)D3 because both analytes would be determined as 25(OH)D3. To obtain accurate measurements of vitamin D levels in mothers and infants, a highly selective and sensitive quantification method for measuring vitamin D metabolites in blood and breastmilk is needed [21]. Thus, in this study, simple, sensitive, and selective liquid chromatography-tandem mass spectrometric (LC-MS/MS) methods were used for determination of 25(OH)D2, 25(OH)D3, and 3-epi-25-hydroxyvitamin D3 (3-Epi25(OH)D3) in plasma, breastmilk, and infant formula.

An automated sample preparation involving protein-crash and solid-phase extraction techniques was applied to ensure simple sample treatment, and reduced time and labor.

During pregnancy, the main source of vitamin D for the fetus is the mother, through the umbilical cord. Studies have reported correlation between maternal and infant cord blood 25(OH)D concentrations [22,23,24,25]. Thus, mothers with sufficient 25(OH)D during pregnancy can provide sufficient cord blood concentrations of 25(OH)D crossing the placenta [26,27]. However, vitamin D metabolites levels < 50 nmol/L have been observed in pregnant women and their offspring [28,29,30].

Pregnant women and infants are highly susceptible to vitamin D deficiency which has been associated with adverse health outcomes, such as pre-eclampsia, perinatal complications, postpartum depression, spontaneous abortion, emergency cesarean section delivery, oligohydramnios, polyhydramnios, and gestational diabetes [31,32]. As for the infants, vitamin D deficiency may cause a small-for-gestational age condition, preterm birth, low birth weight, stunting, impaired fetal bone formation, and rickets [31,32,33,34,35]. Accordingly, Norwegian maternal vitamin D < 30 nmol/L has been associated with lower offspring peak bone mass [36].

Personalized vitamin D supplementation during pregnancy and lactation has been suggested [37]. Monitoring vitamin D deficiency in Norwegian mother-infant pairs before and after childbirth is therefore of importance.

The aim of this study was to validate selective and sensitive LC-MS/MS methods for the analysis of vitamin D metabolites with automated sample preparation. These methods were applied to determine the concentration levels of Vitamin D metabolites in mother-infant pairs during the first six months of breastfeeding. Detection and quantification of 3-Epi25(OH)D3 allows evaluation of the impact of 3-Epi25(OH)D3 when assessing vitamin D metabolites status in plasma and breastmilk. The relationships between plasma vitamin D metabolites levels in mother-infant pairs and breastmilk levels were also examined.

Source: 1. Introduction Source: 1. Introduction Source: 1. Introduction Source: 1. Introduction Source: 1. Introduction

Study methods

What methods does the paper describe?

2.1. Study Population and Design

From January 2016 until February 2017, pregnant women were recruited to participate in a two-armed randomized controlled intervention trial involving cod intake in pregnancy [38]. The study was registered on ClinicalTrials.gov (NCT02610959) in 17 November 2015. All participants were recruited through the womens’ clinic at Haukeland University Hospital in Norway. A total of 137 pregnant women were included in this secondary analysis. Details regarding the main study have been described elsewhere [38].

2.2. Biological Samples and Laboratory Analysis

Blood samples were obtained from mother-infant pairs. The mothers were requested to provide a sample of breastmilk at six weeks and three months postpartum. Breastmilk was collected at the beginning, middle, and end of a chosen feed. The three samples were then stored in a freezer until pick-up by study investigators or submission during the third-month follow-up visit. Samples were placed in freezer packs during transport. Upon arrival in the laboratory, samples were stored at –80 °C until analyzed as a pooled sample.

Meanwhile, blood sampling was conducted in mothers and infants at three and six months postpartum. Plasma samples from the participants were obtained by collecting blood into BD Vacutainer ® K2E 5.4 mg vials (Franklin Lakes, NJ, USA), centrifuged (1000–1300× g, 20 °C, 10 min) within 30 min, and the supernatant was stored at –80 °C until analyzed.

2.3. Laboratory Analysis

2.3.1. Chemical and Reagents

The standards 25(OH)D3, 25(OH)D2, 3-Epi25(OH)D3 and internal standard D6-25(OH)D3-(26,26,26,27,27,27-D6) were obtained from Cerilliant (Round Rock, TX, USA). The internal standards 25(OH)D2-(6,19,19-d3) and 3-Epi25(OH)D3-(6,19,19-d3), zink sulfate monohydrate, formic acid (analytical grade) and ammonium acetate were purchased from Sigma-Aldrich (St Louis, MO, USA).

2.3.2. Sample Preparation

All sample preparation and extraction process were performed using robotic a Dual Head MultiPurpose Sampler (MPS XL) equipped with an Anatune CF-100 Centrifuge Option, MicroLiter ITSP Option and Active WashStation [39,40] Using an automated system, samples were prepared by adding 80 μL of internal standards to aliquots of 200-μL samples. Protein-crash, centrifugation, and solid-phase extraction techniques were automated using MPS XL (Anatune, Cambridge, UK). The samples were precipitated with 200 μL zinc sulfate and 500 μL methanol.

Samples were then vortexed and centrifuged for 5 min. An aliquot of 500 μL of supernatant was loaded for solid phase extraction and eluted with 40 μL methanol. High purity water (18.2 million ohms, MΩ x cm) was added to the eluted sample prior to LC-MS/MS injection.

2.3.3. LC-MS/MS Procedure
Waters Quattro PremierTM/XE

LC-MS/MS conditions for the analysis of plasma samples were as follows. For chromatographic separation, acquity ultra performance liquid chromatography (UPLC) (Waters Corporation, Milford, MA, USA) was used. The system was equipped with a degasser, pump, a thermostated acquity sample manager and column oven. Twenty microliters of the sample was injected into the analytical column (Acquity UPLC, HSS PFP 1.8 µm, 2.1 × 100 mm, Waters, Milford, MA, USA). Two millimole per liter ammonium acetate with 0.1% formic acid was used as mobile phase A, while methanol with 0.3% formic acid was used as mobile phase B.

The Waters binary solvent manager was programmed as follows: 0–3.0 min, 30% A and 70% B; 3.5–5.0 min, 25% A and 75% B; 5.5–6.0 min, 2% A and 98% B; 6.5–8.0 min, 30% A and 70% B. All gradient steps were linear. For sample detection, a triple-quadrupole mass spectrometry system from Waters Quattro PremierTM/XE (Waters Corporation, Milford, MA, USA) was used, equipped with electrospray ion source. MS source parameters are as follows: capillary voltage, 3.0 kV; cone voltage, 15–20 V; source temperature, 120 °C; and cone gas flow rate, 15 L/h.

Nitrogen and argon were used as the cone and collision gases, respectively. Parent and fragment ions were detected in multiple-reaction monitoring (MRM) mode and the respective collision energies are listed in Appendix A. Data acquisition for all experiments was carried out with Masslynx V4.1 software (Waters, Milford, USA).

Agilent MassHunter

LC-MS/MS conditions for the analysis of plasma, breastmilk, and infant formula samples were as follows: For chromatographic separation, an Agilent 1290 UPLC (Agilent Technologies, Palo Alto, CA, USA) was used. The system was equipped with a degasser, pump, a thermostated autosampler, and column oven. Fifteen microliters of the sample was injected to the analytical column (Acquity UPLC, HSS PFP 1.8 µm, 2.1 × 100 mm, Waters, Milford, MA, USA). Two millimole ammonium acetate with 0.1% formic acid was used as mobile phase A, while methanol with 0.3% formic acid was used as mobile phase B.

The Agilent 1290 pump was programmed as follows: 0–3.0 min, 35% A and 65% B; 3.5–4.5 min, 30% A and 70% B; 5.0–6.4 min, 25% A and 75% B; 6.5–8.0 min, 2% A and 98% B; 8.1–9.5 min, 35% A and 65% B. All gradient steps were linear. For sample detection, a triple-quadrupole mass spectrometry system from Agilent 6495B (Agilent Technologies, Santa Clara, CA, USA) was used, equipped with jet stream electronspray ion source. Nitrogen was used as the drying gas, sheath gas, nebulizing gas, and collision gas.

The drying and sheath gas temperatures were 200 °C and 300 °C, respectively. The following settings were used: drying gas flow 13 L/min and sheath gas flow: 10 L/min, nebulizer pressure: 40 psi, capillary voltage: 5000 V, and nozzle voltage: 2000 V. Parent and fragment ions were detected in multiple-reaction monitoring (MRM) mode and the respective collision energies are listed in Appendix A. The Agilent MassHunter Workstation software version B.08.00. (Agilent Technologies, Santa Clara, CA, USA) was used to control the LC-MS system, peak integration, quantitation, and calculation.

2.4. LC-MS/MS Assay Validation. Linearity, Sensitivity, Precision, Accuracy, and Recovery

Method validation was performed according to bioanalytical method guidelines for biological samples and industry [41,42]. The linearity of the two methods were assessed using six concentration levels of 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3, analyzed for ten consecutive days. Sensitivity was determined by calculating the lower limit of detection (LOD) and lower limit of quantification (LOQ). The LOD was determined using the concentration of the lowest diluted sample with signal-to-noise ratio at approximately three. The LOQ was set as the concentration of the lowest standard.

Precision and accuracy were determined by an intra-day and inter-day analysis of in-house quality control samples. Precision was calculated as relative standard deviation (RSD) of experimental concentrations, and the criteria for acceptability was 15% RSD, except for the LOQ where it should not have exceeded 20%. Accuracy was calculated as the comparison between the measured values and nominal sample concentrations. The criteria for acceptability were 15% and 20% (at LOQ) deviation from the nominal values. An in-house quality control plasma sample consisting of 25(OH)D3 at a medium level was used to estimate intra-assay and inter-assay precision and accuracy of 25(OH)D3 for the Waters Quattro PremierTM/XE method.

For the Agilent 6495B method, three concentration levels (low, medium, and high) of in-house quality control samples were prepared in plasma, breastmilk, and infant formula. The baseline concentrations of 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 were measured prior to addition of the standard solutions. The 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 were then assayed for intra-assay precision and accuracy for ten consecutive days. The inter-assay precision was evaluated for 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3. Accuracy was determined using commercial quality control (QC) plasma samples; standard reference materials (SRM) 972a-C level 1, SRM 972a-C level 2, SRM 972a-C level 3, and SRM 972a-C level 4 Vitamin D Metabolites in frozen human serum.

SRM 1950 metabolites in frozen human plasma were also used. In addition, QC serum samples were also included (SRM 972 level 2, SRM 1950, and SRM 2972). The recovery of the analytes was studied by spiking the samples (plasma, breastmilk, and infant formula) with standard solutions at three levels. Recovery was evaluated by comparing the baseline (unspiked) and spiked samples at three levels (low, medium, and high). Recovery was then calculated by comparing the measured concentration of the prepared samples with the nominal value (baseline and spiked concentration) representing 100% recovery.

2.5. Data Analysis and Statistical Analyses

LC-MS/MS data were analyzed by Agilent MassHunter 8.0 Quan Browser (Agilent Technologies, Santa Clara, CA, USA). The levels of vitamin D metabolites are presented as mean and standard deviation (SD). To examine differences between status and categories paired Student’s t-test was used. Pearson’s correlation coefficients were used to assess associations between continuous variables. A 2-sided p-value of <0.05 was considered significant. All statistical analyses were performed using IBM SPSS Statistics 26 (IBM Corp., Armonk, NY, USA).

Source: 2. Materials and Methods Source: 2. Materials and Methods Source: 2. Materials and Methods Source: 2. Materials and Methods Source: 2. Materials and Methods

Results: Evaluation of the LC-MS/MS Assay

The LC MS/MS methods for the determination of 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 using Waters Quattro PremierTM/XE, and 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 using Agilent 6495B were developed and validated. The base peak ions and fragments of 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 ([M + H]+) are shown in Appendix A. The Waters Quattro PremierTM/XE is equipped with an electronspray ion source and Agilent 6495B is equipped with a jet stream electronspray ion source. The selected reaction monitoring was based on the mass-to-charge ratio (m/z).

The Agilent 6495B MRM chromatograms of the analytes are shown in the Supplementary Material Figure S1. It provided separation between metabolites, with 25(OH)D3, 25(OH)D2, and 3-Epi25(OH)D3 eluting at 6.95, 7.18, and 7.19 min, respectively. The same was observed using Waters Quattro PremierTM/XE with the mass-to-charge ratio (m/z) and fragmentations distinguished for Waters Quattro PremierTM/XE (data not shown).

The Waters Quattro PremierTM/XE method was linear for 25(OH)D3, 25(OH)D2, and 3-Epi25(OH)D3 as shown in Table 1, and the best fits were indicated by a correlation coefficient (r) of 0.99 for 25(OH)D3, 25(OH)D2, and 3-Epi25(OH)D3. The Agilent 6495B method was linear for 25(OH)D3, 25(OH)D2, and 3-Epi25(OH)D3 with correlation coefficients ≥ 0.999. The standard curves are considered acceptable when r is >0.99. The limit of detection (LOD) and limit of quantification (LOQ) were determined to evaluate sensitivity of the method and are shown in Table 1a for Quattro PremierTM/XE and Table 1b for Agilent 6495B.

The intra-assay and inter-assay precision and accuracy are summarized in Table 2 and Table 3. Relative standard deviation (RSD) values for quality control (QC) plasma, breastmilk, and infant formula samples measured with Waters Quattro PremierTM/XE and with Agilent 6495B were below 20% for 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3, respectively. For low concentration levels, RSD value for breastmilk was 30% for 3-Epi25(OH)D3. The methods showed accuracy within 20%, as shown in Appendix B. The recoveries of the analytes obtained with the use of automated solid phase extraction and filtration autosampler, Gerstel multi-purpose sampler, ranged from 88% to 120%, 72% to 103% and 81% to 129% for plasma, breastmilk, and infant formula, respectively as shown in Appendix C.

Table 1

Linearity, limit of quantification, and limit of detection of vitamin D metabolites measured by (a) Waters Quattro PremierTM/XE and (b) Agilent 6495B.

LinearityrLOQLOD
a. Waters Quattro PremierTM/XE nmol/L nmol/L nmol/L
25(OH)D2 7.6–242.30.99697.62.3
25(OH)D37.8–249.60.99857.82.34
3-Epi25(OH)D37.8–249.60.99867.82.3
b. Agilent 6495B
25(OH)D2 7.0–3350.99997.02.1
25(OH)D34.3–2700.99984.31.3
3-Epi25(OH)D31.7–1370.99991.70.5

Limit of quantification (LOQ), limit of detection (LOD).

Table 2

Intra-day (n) of vitamin D metabolites in plasma, breastmilk, and infant formula samples measured by (a) Waters Quattro PremierTM/XE and (b) Agilent 6495B.

Intra-Day PrecisionVitamin D Metabolites
a. Waters Quattro PremierTM/XE
Plasma (n = 6) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Medium1
 Average (nmol/L)-55.7 ± 4.8-
 RSD (%) 8
b. Agilent 6495B
Plasma (n = 10) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Low2
 Average (nmol/L)31.5 ± 4.446.1 ± 2.834.6 ± 2.7
 RSD (%)1468
Medium2
 Average (nmol/L)76.2 ± 7.5111.0 ± 3.9 49.3 ± 3.5
 RSD (%)1037
High2
 Average (nmol/L)120.3 ± 8.9177.9 ± 14.6105.6 ± 5.6
 RSD (%)785
Breastmilk (n = 10) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Low3
 Average (nmol/L)<LOQ11.7 ± 1.96.8 ± 1.0
 RSD (%) 1614
Medium3
 Average (nmol/L)47.8 ± 3.071.6 ± 2.551.7 ± 2.3
 RSD (%)644
High3
 Average (nmol/L)103.1 ± 4.4126.8 ± 9.496.7 ± 4.6
 RSD (%)475
Infant formula (n = 10) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Low4
 Average (nmol/L)<7.6 <7.8<7.8
 RSD (%)
Medium4
 Average (nmol/L)18.1 ± 3.075.3 ± 6.631.1 ± 1.7
 RSD (%)1795
High4
 Average (nmol/L)88.5 ± 8.0119.2 ± 6.1109 ± 3.3
 RSD (%)953

Relative standard deviation (RSD %).

Table 3

Inter-day precision (n) of vitamin D metabolites in plasma, breastmilk, and infant formula samples measured by (a) Waters Quattro PremierTM/XE and (b) Agilent 6495B.

Analyte
a. Waters Quattro PremierTM/XE
Plasma (n = 10) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Medium1
 Average (nmol/L)-55.5 ± 5.2-
 RSD (%) 9
b. Agilent 6495B
Plasma (n = 10) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Low2
 Average (nmol/L)30.2 ± 2.742.9 ± 3.434.5 ± 2.2
 RSD (%)986
Medium2
 Average (nmol/L)71.2 ± 4.2 102.6 ± 5.648.2 ± 3.6
 RSD (%)657
High2
 Average (nmol/L)115.3 ± 8.9162.7 ± 9.099.9 ± 5.6
 RSD (%)866
Breastmilk (n = 10) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Low3
 Average (nmol/L)<712.0 ± 25.8 ± 1.7
 RSD (%) 1730
Medium3
 Average (nmol/L)39.9 ± 2.765.0 ± 5.245.7 ± 2.6
 RSD (%)786
High3
 Average (nmol/L)97.9 ± 4.6 114.8 ± 892.0 ± 9
 RSD (%)5710
Infant formula (n = 10) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Low4
 Average (nmol/L)<7<4.3<1.7
 SD
 RSD (%)
Medium4
 Average (nmol/L)21.4 ± 2.366.6 ± 2.732.2 ± 1.8
 RSD (%)1146
High4
 Average (nmol/L)93.2 ± 8.7112.1 ± 4.1107.1 ± 3.6
 RSD (%)943
Source: 3.1. Evaluation of the LC-MS/MS Assay Source: 3.1. Evaluation of the LC-MS/MS Assay Source: 3.1. Evaluation of the LC-MS/MS Assay Source: 3.1. Evaluation of the LC-MS/MS Assay Source: 3.1. Evaluation of the LC-MS/MS Assay Source: 3.1. Evaluation of the LC-MS/MS Assay

Vitamin D Levels at Each Time-Point for Maternal and Infant Plasma Samples

Results: Vitamin D Levels at Each Time-Point for Maternal and Infant Plasma Samples

Table 4 shows the number of samples collected. The samples were divided into 3 diagnostic categories according to 25(OH)D status: deficient (25(OH)D < 50 nmol/L), insufficient (50 nmol/L < 25(OH)D < 75 nmol/L), and sufficient (25(OH)D ≥ 75 nmol/L). The 3-Epi25(OH)D3 was not included in the calculations. Eighteen percent and 30.6% of the measured breastmilk samples had 25(OH)D levels lower than 50 nmol/L, 39.3% and 40% had levels between 50 and 75 nmol/L, and 42.7% and 29.4% had levels equal to or more than 75 nmol/L at 6 weeks and 3 months, respectively.

Prevalence of 25(OH)D deficiency was determined in mother-infant pairs (Table 4). At 3 months, 63% of maternal 25(OH)D plasma levels were less than 75 nmol/L 25(OH)D. Accordingly, 31% of the infants were categorized as vitamin D deficient (25(OH)D < 50 nmol/L).

Table 4

Distribution of vitamin D status at each time-point (6 weeks, 3, and 6 months) for maternal and infant samples.

WeeksMonths
Mothers 636
Breastmilk n 1 89 (%)85 (%)
 Deficient<50 nmol/L16 (18.0)26 (30.6)
 Insufficient50–74 nmol/L 35 (39.3)34 (40.0)
 Sufficient≥75 nmol/L38 (42.7)25 (29.4)
Plasma n 1 87 (%)84 (%)
 Deficient<50 nmol/L 11 (12.6)12 (14.3)
 Insufficient50–74 nmol/L 44 (50.6)40 (47.6)
 Sufficient≥75 nmol/L 32 (36.8)32 (38.1)
Infants
Plasma Total 52 (%)48 (%)
 Deficient<50 nmol/L 16 (30.8)4 (8.3)
 Insufficient50–74 nmol/L 15 (28.8)23 (47.9)
 Sufficient≥75 nmol/L 21 (40.4)21 (43.8)

1 number of samples (n).

Source: 3.2. Vitamin D Levels at Each Time-Point for Maternal and Infant Plasma Samples Source: 3.2. Vitamin D Levels at Each Time-Point for Maternal and Infant Plasma Samples

Maternal and Infant Plasma Vitamin D Metabolites Concentration at 3 and 6 Months

Results: Maternal and Infant Plasma Vitamin D Metabolites Concentration at 3 and 6 Months

The 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 plasma levels of the mothers and their infants, and the breastmilk levels of vitamin D metabolites at 6 weeks and 3 months are presented in Table 5. At 3 months, the concentration of 3-Epi25(OH)D3 contributed 11% and 24% of the total 25(OH)D3 in infants’ plasma and breastmilk, respectively.

Table 5

Concentration levels of 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 at 6 weeks, 3, and 6 months among mother and infant. Paired samples tests.

WeeksMonthsp Value 1
6 36
Mothers nmol/Lnmol/L
Breastmilk25(OH)D2 12.8 ± 6.712.7 ± 7.1-0.728
25(OH)D3 60.1 ± 24.850.0 ± 23.4-0.001
3-Epi25(OH)D319.7 ± 8.718.6 ± 9.0-0.327
nmol/Lnmol/L
Plasma 25(OH)D2 <7.6 2<7.6
25(OH)D3 69.6 ± 16.369.6 ± 19.00.526
3-Epi25(OH)D3 <7.8<7.8
Infants
Plasma25(OH)D2 <7.6<7.6
25(OH)D3 64.6 ± 29.183.1 ± 270.001
3-Epi25(OH)D3 7.8 ± 4.8<7.6

1 Paired samples test. 2 The number of breastmilk samples below limit of quantification (LOQ) were 31 and 32 for 25(OH)D2, 0 and 2 for 25(OH)D3, and 1 and 3 for 3-Epi25(OH)D3 at 6 weeks and 3 months, respectively. The number of infant plasma samples below LOQ were 19 and 20 for 3-Epi25(OH)D3 at 3 and 6 months, respectively.

Source: 3.3. Maternal and Infant Plasma Vitamin D Metabolites Concentration at 3 and 6 Months Source: 3.3. Maternal and Infant Plasma Vitamin D Metabolites Concentration at 3 and 6 Months

Correlation between Vitamin D Metabolites and Mother and Infant Levels of Vitamin D Metabolites

Results: Correlation between Vitamin D Metabolites and Mother and Infant Levels of Vitamin D Metabolites

At 6 weeks, a positive association between breastmilk concentration of 25(OH)D3 and 3-Epi25(OH)D3 (p < 0.01; r = 0.711, Figure 1a) was observed. The same was seen at 3 months (p < 0.01; r = 0.805, Figure 1b). There was also a positive association observed between the infant’s plasma levels of 25(OH)D3 and 3-Epi25(OH)D3 (p < 0.01, r = 0.678) at 3 months. A positive association between mother and infant plasma levels of 25(OH)D3 was observed (p < 0.01; r = 0.555, Figure 2).

Source: 3.4. Correlation between Vitamin D Metabolites and Mother and Infant Levels of Vitamin D Metabolites

Discussion

In this study, a robotic autosampler was used to automate sample preparation prior to LC-MS/MS analysis which included protein-crash, solid-phase extraction techniques and dilution. This ensured reproducibility, simple sample treatment, and reduced time and labor and costs. Two simple, sensitive, and selective LC-MS/MS methods were then used to separate and detect 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3. The concentrations of 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 in plasma were measured with Waters Quattro PremierTM/XE. Breastmilk samples were measured with Agilent 6495B which resulted in an improved detection limit.

Both LC-MS/MS methods separated 3-Epi25(OH)D3 from 25(OH)D3 for accurate detection and measurement of 25(OH)D3. Our validation showed a concentration-response relationship fitted with a simple regression model. The accuracy and inter-precision were within the acceptable criteria of RSD at 15% for 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 in plasma, breastmilk, and infant formula [42] with an exception of the measured inter-precision RSD for 25(OH)D2 in infant formula (17%.) At LOQ levels, the 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 were also within the acceptable criteria of 20% RSD.

The intra-precision was within acceptable criteria of 15% RSD. This also applies at LOQ levels with an exception for 3-Epi25(OH)D3 in breastmilk with an RSD of 30%. These two LC-MS/MS methods were used to determine the vitamin D status in Norwegian mother-infant pairs.

The LC-MS/MS methods presented in this study distinguished between 25(OH)D3 and 3-Epi25(OH)D3. At 3 months, the C-3 epimer contributed 11% of the total 25(OH)D in infants’ plasma. Thus, if 3-Epi25(OH)D3 was not distinguished from 25(OH)D3, only 25% of the infants are categorized as vitamin D deficient instead of 31%. The observed positive correlation between infants’ 25(OH)D3 and 3-Epi25(OH)D3 at 3 months suggests possible overestimation of 25(OH)D3 and more likely, misclassification of vitamin D in studies using methods that only measure 25(OH)D3 [43].

In breastmilk, at 3 and 6 months, the 3-Epi25(OH)D3 contributed 24% and 27% of the total 25(OH)D, respectively. In addition, positive associations were also observed between 25(OH)D3 and 3-Epi25(OH)D3 in breastmilk at 6 weeks and 3 months. Accordingly, studies have shown positive correlation between 25(OH)D3 and 3-Epi25(OH)D3 in both maternal and cord blood [43,44]. This may imply maternal cord blood and breastmilk as a possible source of 3-Epi25(OH)D3 in infants. Studies on epimers function and source are warranted.

Infants are highly dependent on their mother’s cord 25(OH)D concentrations, which is usually 60–80% of maternal values at delivery [45,46]. A survey of 25(OH)D levels in pregnant Black South Africans gave a mean of 57.0 nmol/L, while 41.9 nmol/L was found in the cord blood [47]. On the other hand, the measured concentrations of 25(OH)D in light-skinned pregnant women at northern latitudes was 71.4 nmol/L, while 39.2 nmol/L was recorded for cord blood [48].

Another study observed that in pregnant women, the mean 25(OH)D concentrations were 41 nmol/L and 50.7 nmol/L during the first trimester and in the umbilical cord, respectively [49]. Meanwhile, vitamin D deficiency appears to be common in mothers and their infants in New Zealand, with mean cord blood 25(OH)D value of 41 nmol/L [50]. In general, studies suggest that low levels of 25(OH)D in mothers are likely to be reflected in their infants. In this study, maternal plasma levels, at 3 and 6 months, 13% and 14% of mothers were categorized as deficient (25(OH)D < 50 nmol/L), 51% and 48% as insufficient (50 nmol/L < 25(OH)D < 75 nmol/L), and 37% and 38% as sufficient (25(OH)D ≥ 75 nmol/L), respectively.

However, 31% and 29% of the infants had deficient and insufficient 25(OH)D status at 3 months, respectively. Vitamin D body stored in infants can decline by 50% over less than a month, hence without another source of vitamin D, vitamin D deficiency can develop [51]. This may explain the higher prevalence of 25(OH)D deficiency in infants compared with mothers.

A positive association between maternal 25(OH)D plasma levels and infant 25(OH)D plasma levels at 3 months was observed. The maternal and infant 25(OH)D3 plasma concentrations were 69.6 (±16.3) nmol/L and 64.9 (±29.1) nmol/L, respectively. Hence, measured infant plasma level of 25(OH)D at 3 months may reflect the 25(OH)D transferred from mother to infant during pregnancy and start of vitamin D supplement. There was a rise of infant plasma 25(OH)D concentration observed from 3 months to 6 months. Accordingly, a positive correlation between maternal and infant plasma was no longer observed suggesting an increase in 25(OH)D level as a possible result of vitamin D supplementation and start of fortified complementary feeding.

In Norway, vitamin D supplements, such as vitamin D drops or cod liver oil, are recommended for all infants from the age of four weeks. A Norwegian population study showed that 92% of the children at age 9-16 months were given vitamin D containing supplements [30]. Here, results showed decreased prevalence of 25(OH)D deficiency in infants, from 3 months (31%) to 6 months (8%). Even with the decrease in vitamin D deficiency prevalence at 6 months, vitamin D deficiency originating in the intrauterine period or immediately after birth to 3 months may still result in adverse effects on skeletal development [49,52].

Correspondingly, in vitamin D-deficient infants, rickets usually develops between the age of 6 months and 2 years [53]. Interestingly, the prevalence of infants categorized as 25(OH)D sufficient at 3 and 6 months had a minor change: 40% and 44%, respectively.

The WHO’s recommendation of exclusive breastfeeding for 6 months may further lead to vitamin D deficiency among infants [54,55]. Although breastmilk is rich in essential nutrients for the earliest life stage, it contains about three-times-less vitamin D than the maternal circulating concentration [56]. A study showed that during the third trimester of pregnancy, maternal 25(OH)D was 60 nmol/L, and the breastmilk level at delivery was 1.26 nmol/L [57]. As for non-Vitamin-D-supplemented Norwegian mothers and infants, a study reported no change in mother’s plasma levels of 25(OH)D (58 to 42 nmol/L) between 4 days and 6 weeks after birth.

However, infant’s plasma levels dropped from 26 to 15 nmol/L, thus, suggesting that Norwegian mothers have insufficient 25(OH)D, and therefore that breastmilk is inadequate as a lone source of vitamin D, and supplementation of 10 µg per day is recommended [18,58,59].

There was no observed change in maternal 25(OH)D plasma levels between 3 and 6 months. The prevalence of maternal vitamin D deficiency at 3 and 6 months was almost the same. Likewise, another study showed that the measured 25(OH)D3 of 67 nmol/L did not change between 2 weeks and 12 months postpartum [60]. Thus, maternal vitamin status was maintained through 6 months of breastfeeding and possibly just enough for their own needs. These results do not support the theory that maternal vitamin D status decreases due to a transfer of vitamin D from the mother to infant through breastmilk [61].

Accordingly, breastmilk 25(OH)D2 remained unchanged between 6 weeks and 3 months. In contrast, breastmilk concentration of 25(OH)D3 decreased from 6 weeks to 3 months. Thus, decreased level of 25(OH)D3 in breastmilk suggests that transfer of 25(OH)D3 to breastmilk production was not prioritized. Studies have shown that vitamin D is readily transferred into breastmilk, while 25(OH)D is transferred very poorly, and 1,25 (OH)2D is not transferred at all [62]. This may explain the lack of association between maternal plasma and breastmilk 25(OH)D3 concentration.

Thus, 25(OH)D in the blood may not be a good reflection of the available amount of vitamin D that can be transferred to infants through breastfeeding. Accordingly, studies have also reported that UV exposure and increased maternal vitamin D supplementation showed minimal changes in 25(OH)D concentrations but a profound increase in breastmilk concentration of vitamin D was observed [56,63]. Thus, measurement of vitamin D3 and vitamin D2 in breastmilk and plasma samples in this study population is warranted.

In this study, an automated robust sample preparation was used. The methods distinguished between 25(OH)D3 and 3 epimer of 25(OH)D3, 3-Epi25(OH)D3 preventing overestimation of 25(OH)D3 and misclassification of vitamin D status. However, a limitation in this study is that two different LC-MS/MS methods were used, resulting in different validation parameters and LOD. Anyhow, the challenge with the overestimation of 25(OH)D3 has been addressed and managed resulting in a reliable quantification of 25(OH)D. Here, we provided novel results of 25(OH)D status in Norwegian mother-infant pairs during the first 6 months of breast feeding.

A possible source of 3-epi-25(OH)2D3 was also discussed. Prevalence of vitamin D deficiency (25(OH)D < 50 nmol/L) among Norwegian mother-infant pairs was determined. Surprisingly, a prevalence of 31% 25(OH)D deficiency was observed among infants at three months. Studies suggest the importance of vitamin D supplementation during pregnancy, and the breastfeeding period to ensure the achievement of the recommended 25(OH)D level of at least 75 nmol/L in mothers and their infants [17,20,34,64,65].

Vitamin D supplementation in pregnant women seems to reduce the risk of pre-eclampsia, gestational diabetes, low birthweight, and severe postpartum hemorrhage [66]. Wide ranges of vitamin D doses, from 400 to 2000 IU have been recommended [17,67,68,69]. However, some doses may not result in optimal 25(OH)D levels during pregnancy. This may be due to interindividual variability in vitamin D metabolism and other factors [70,71]. Thus, establishing a personalized dosing regimen has been suggested [37].

Source: 4. Discussion Source: 4. Discussion Source: 4. Discussion Source: 4. Discussion Source: 4. Discussion Source: 4. Discussion Source: 4. Discussion

Results

3.1. Evaluation of the LC-MS/MS Assay

The LC MS/MS methods for the determination of 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 using Waters Quattro PremierTM/XE, and 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 using Agilent 6495B were developed and validated. The base peak ions and fragments of 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 ([M + H]+) are shown in Appendix A. The Waters Quattro PremierTM/XE is equipped with an electronspray ion source and Agilent 6495B is equipped with a jet stream electronspray ion source. The selected reaction monitoring was based on the mass-to-charge ratio (m/z).

The Agilent 6495B MRM chromatograms of the analytes are shown in the Supplementary Material Figure S1. It provided separation between metabolites, with 25(OH)D3, 25(OH)D2, and 3-Epi25(OH)D3 eluting at 6.95, 7.18, and 7.19 min, respectively. The same was observed using Waters Quattro PremierTM/XE with the mass-to-charge ratio (m/z) and fragmentations distinguished for Waters Quattro PremierTM/XE (data not shown).

The Waters Quattro PremierTM/XE method was linear for 25(OH)D3, 25(OH)D2, and 3-Epi25(OH)D3 as shown in Table 1, and the best fits were indicated by a correlation coefficient (r) of 0.99 for 25(OH)D3, 25(OH)D2, and 3-Epi25(OH)D3. The Agilent 6495B method was linear for 25(OH)D3, 25(OH)D2, and 3-Epi25(OH)D3 with correlation coefficients ≥ 0.999. The standard curves are considered acceptable when r is >0.99. The limit of detection (LOD) and limit of quantification (LOQ) were determined to evaluate sensitivity of the method and are shown in Table 1a for Quattro PremierTM/XE and Table 1b for Agilent 6495B.

The intra-assay and inter-assay precision and accuracy are summarized in Table 2 and Table 3. Relative standard deviation (RSD) values for quality control (QC) plasma, breastmilk, and infant formula samples measured with Waters Quattro PremierTM/XE and with Agilent 6495B were below 20% for 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3, respectively. For low concentration levels, RSD value for breastmilk was 30% for 3-Epi25(OH)D3. The methods showed accuracy within 20%, as shown in Appendix B. The recoveries of the analytes obtained with the use of automated solid phase extraction and filtration autosampler, Gerstel multi-purpose sampler, ranged from 88% to 120%, 72% to 103% and 81% to 129% for plasma, breastmilk, and infant formula, respectively as shown in Appendix C.

3.2. Vitamin D Levels at Each Time-Point for Maternal and Infant Plasma Samples

Table 4 shows the number of samples collected. The samples were divided into 3 diagnostic categories according to 25(OH)D status: deficient (25(OH)D < 50 nmol/L), insufficient (50 nmol/L < 25(OH)D < 75 nmol/L), and sufficient (25(OH)D ≥ 75 nmol/L). The 3-Epi25(OH)D3 was not included in the calculations. Eighteen percent and 30.6% of the measured breastmilk samples had 25(OH)D levels lower than 50 nmol/L, 39.3% and 40% had levels between 50 and 75 nmol/L, and 42.7% and 29.4% had levels equal to or more than 75 nmol/L at 6 weeks and 3 months, respectively.

Prevalence of 25(OH)D deficiency was determined in mother-infant pairs (Table 4). At 3 months, 63% of maternal 25(OH)D plasma levels were less than 75 nmol/L 25(OH)D. Accordingly, 31% of the infants were categorized as vitamin D deficient (25(OH)D < 50 nmol/L).

3.3. Maternal and Infant Plasma Vitamin D Metabolites Concentration at 3 and 6 Months

The 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 plasma levels of the mothers and their infants, and the breastmilk levels of vitamin D metabolites at 6 weeks and 3 months are presented in Table 5. At 3 months, the concentration of 3-Epi25(OH)D3 contributed 11% and 24% of the total 25(OH)D3 in infants’ plasma and breastmilk, respectively.

3.4. Correlation between Vitamin D Metabolites and Mother and Infant Levels of Vitamin D Metabolites

At 6 weeks, a positive association between breastmilk concentration of 25(OH)D3 and 3-Epi25(OH)D3 (p < 0.01; r = 0.711, Figure 1a) was observed. The same was seen at 3 months (p < 0.01; r = 0.805, Figure 1b). There was also a positive association observed between the infant’s plasma levels of 25(OH)D3 and 3-Epi25(OH)D3 (p < 0.01, r = 0.678) at 3 months. A positive association between mother and infant plasma levels of 25(OH)D3 was observed (p < 0.01; r = 0.555, Figure 2).

Table 1

Linearity, limit of quantification, and limit of detection of vitamin D metabolites measured by (a) Waters Quattro PremierTM/XE and (b) Agilent 6495B.

LinearityrLOQLOD
a. Waters Quattro PremierTM/XE nmol/L nmol/L nmol/L
25(OH)D2 7.6–242.30.99697.62.3
25(OH)D37.8–249.60.99857.82.34
3-Epi25(OH)D37.8–249.60.99867.82.3
b. Agilent 6495B
25(OH)D2 7.0–3350.99997.02.1
25(OH)D34.3–2700.99984.31.3
3-Epi25(OH)D31.7–1370.99991.70.5

Limit of quantification (LOQ), limit of detection (LOD).

Table 2

Intra-day (n) of vitamin D metabolites in plasma, breastmilk, and infant formula samples measured by (a) Waters Quattro PremierTM/XE and (b) Agilent 6495B.

Intra-Day PrecisionVitamin D Metabolites
a. Waters Quattro PremierTM/XE
Plasma (n = 6) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Medium1
 Average (nmol/L)-55.7 ± 4.8-
 RSD (%) 8
b. Agilent 6495B
Plasma (n = 10) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Low2
 Average (nmol/L)31.5 ± 4.446.1 ± 2.834.6 ± 2.7
 RSD (%)1468
Medium2
 Average (nmol/L)76.2 ± 7.5111.0 ± 3.9 49.3 ± 3.5
 RSD (%)1037
High2
 Average (nmol/L)120.3 ± 8.9177.9 ± 14.6105.6 ± 5.6
 RSD (%)785
Breastmilk (n = 10) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Low3
 Average (nmol/L)<LOQ11.7 ± 1.96.8 ± 1.0
 RSD (%) 1614
Medium3
 Average (nmol/L)47.8 ± 3.071.6 ± 2.551.7 ± 2.3
 RSD (%)644
High3
 Average (nmol/L)103.1 ± 4.4126.8 ± 9.496.7 ± 4.6
 RSD (%)475
Infant formula (n = 10) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Low4
 Average (nmol/L)<7.6 <7.8<7.8
 RSD (%)
Medium4
 Average (nmol/L)18.1 ± 3.075.3 ± 6.631.1 ± 1.7
 RSD (%)1795
High4
 Average (nmol/L)88.5 ± 8.0119.2 ± 6.1109 ± 3.3
 RSD (%)953

Relative standard deviation (RSD %).

Table 3

Inter-day precision (n) of vitamin D metabolites in plasma, breastmilk, and infant formula samples measured by (a) Waters Quattro PremierTM/XE and (b) Agilent 6495B.

Analyte
a. Waters Quattro PremierTM/XE
Plasma (n = 10) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Medium1
 Average (nmol/L)-55.5 ± 5.2-
 RSD (%) 9
b. Agilent 6495B
Plasma (n = 10) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Low2
 Average (nmol/L)30.2 ± 2.742.9 ± 3.434.5 ± 2.2
 RSD (%)986
Medium2
 Average (nmol/L)71.2 ± 4.2 102.6 ± 5.648.2 ± 3.6
 RSD (%)657
High2
 Average (nmol/L)115.3 ± 8.9162.7 ± 9.099.9 ± 5.6
 RSD (%)866
Breastmilk (n = 10) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Low3
 Average (nmol/L)<712.0 ± 25.8 ± 1.7
 RSD (%) 1730
Medium3
 Average (nmol/L)39.9 ± 2.765.0 ± 5.245.7 ± 2.6
 RSD (%)786
High3
 Average (nmol/L)97.9 ± 4.6 114.8 ± 892.0 ± 9
 RSD (%)5710
Infant formula (n = 10) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Low4
 Average (nmol/L)<7<4.3<1.7
 SD
 RSD (%)
Medium4
 Average (nmol/L)21.4 ± 2.366.6 ± 2.732.2 ± 1.8
 RSD (%)1146
High4
 Average (nmol/L)93.2 ± 8.7112.1 ± 4.1107.1 ± 3.6
 RSD (%)943
Table 4

Distribution of vitamin D status at each time-point (6 weeks, 3, and 6 months) for maternal and infant samples.

WeeksMonths
Mothers 636
Breastmilk n 1 89 (%)85 (%)
 Deficient<50 nmol/L16 (18.0)26 (30.6)
 Insufficient50–74 nmol/L 35 (39.3)34 (40.0)
 Sufficient≥75 nmol/L38 (42.7)25 (29.4)
Plasma n 1 87 (%)84 (%)
 Deficient<50 nmol/L 11 (12.6)12 (14.3)
 Insufficient50–74 nmol/L 44 (50.6)40 (47.6)
 Sufficient≥75 nmol/L 32 (36.8)32 (38.1)
Infants
Plasma Total 52 (%)48 (%)
 Deficient<50 nmol/L 16 (30.8)4 (8.3)
 Insufficient50–74 nmol/L 15 (28.8)23 (47.9)
 Sufficient≥75 nmol/L 21 (40.4)21 (43.8)

1 number of samples (n).

Table 5

Concentration levels of 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 at 6 weeks, 3, and 6 months among mother and infant. Paired samples tests.

WeeksMonthsp Value 1
6 36
Mothers nmol/Lnmol/L
Breastmilk25(OH)D2 12.8 ± 6.712.7 ± 7.1-0.728
25(OH)D3 60.1 ± 24.850.0 ± 23.4-0.001
3-Epi25(OH)D319.7 ± 8.718.6 ± 9.0-0.327
nmol/Lnmol/L
Plasma 25(OH)D2 <7.6 2<7.6
25(OH)D3 69.6 ± 16.369.6 ± 19.00.526
3-Epi25(OH)D3 <7.8<7.8
Infants
Plasma25(OH)D2 <7.6<7.6
25(OH)D3 64.6 ± 29.183.1 ± 270.001
3-Epi25(OH)D3 7.8 ± 4.8<7.6

1 Paired samples test. 2 The number of breastmilk samples below limit of quantification (LOQ) were 31 and 32 for 25(OH)D2, 0 and 2 for 25(OH)D3, and 1 and 3 for 3-Epi25(OH)D3 at 6 weeks and 3 months, respectively. The number of infant plasma samples below LOQ were 19 and 20 for 3-Epi25(OH)D3 at 3 and 6 months, respectively.

Source: 3. Results Source: 3. Results Source: 3. Results Source: 3. Results Source: 3. Results Source: 3. Results Source: 3. Results Source: 3. Results Source: 3. Results

Conclusions

In summary, two simple, sensitive, and selective LC-MS/MS methods enable reliable quantification of 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3. The automated sample preparation makes it suitable for routine laboratory analysis of plasma, breastmilk, and infant formula. This study demonstrated the importance of separating 3-Epi25(OH)D3 from 25(OH)D3 to prevent overestimation of 25(OH)D3 and misclassification of vitamin D status. Accordingly, at 3 months, 13% and 31% of the mothers and infants were categorized as vitamin D deficient (25(OH)D < 50 nmol/L), respectively. Thus, we suggest monitoring vitamin D metabolites in infant, maternal plasma, and breastmilk to ensure adequate levels in both mother and infant in the first 6 months of infant life.

Further studies on personalized supplementation with vitamin D during pregnancy and breastfeeding are warranted.

Source: 5. Conclusions
Authors’ abstract

Vitamin D deficiency in pregnant women and their offspring may result in unfavorable health outcomes for both mother and infant. A 25hydroxyvitamin D (25(OH)D) level of at least 75 nmol/L is recommended by the Endocrine Society. Validated, automated sample preparation and liquid chromatography-tandem mass spectrometry (LC-MS/MS) methods were used to determine the vitamin D metabolites status in mother-infant pairs. Detection of 3-Epi25(OH)D3 prevented overestimation of 25(OH)D3 and misclassification of vitamin D status. Sixty-three percent of maternal 25(OH)D plasma levels were less than the recommended level of 25(OH)D at 3 months.

Additionally, breastmilk levels of 25(OH)D decreased from 60.1 nmol/L to 50.0 nmol/L between six weeks and three months (p < 0.01). Furthermore, there was a positive correlation between mother and infant plasma levels (p < 0.01, r = 0.56) at 3 months. Accordingly, 31% of the infants were categorized as vitamin D deficient (25(OH)D < 50 nmol/L) compared to 25% if 3-Epi25(OH)D3 was not distinguished from 25(OH)D3. This study highlights the importance of accurate quantification of 25(OH)D. Monitoring vitamin D metabolites in infant, maternal plasma, and breastmilk may be needed to ensure adequate levels in both mother and infant in the first 6 months of infant life.

Read the full paper

1. Introduction

Vitamin D plays an important role in bone metabolism. It regulates the calcium and phosphate in the body, making it important for muscle, tooth, and growth development [1]. It may also play an important role in immune system regulation [2,3]. The source of vitamin D in Norwegian diets is in the form of vitamin D2 (ergocalciferol) from plants and vitamin D3 (cholecalciferol) from fish, butter, and eggs [4]. Vitamin D2 and D3 bind to the Vitamin D carrier protein (DBP) before transported to the liver for hydroxylation, producing 25-hydroxyvitamin (25(OH)) D3 and 25(OH)D2.

The 25(OH)D2 is derived solely from the diet/supplements and 25(OH)D3 is either derived from the diet/supplements or synthesized in the skin. The C3 epimer forms of vitamin D3 have less affinity toward vitamin D protein and even lower affinity for vitamin D receptors compared to 25(OH)D3. The 3-Epi25(OH)D3 binds to vitamin D receptor (VDR) at 2–3% the affinity of 25(OH)D3 [5]. Studies have also shown reduced ability in inducing calcium transport and reduced gene expression in the human colonic carcinoma cell line, Caco-2 [6,7,8].

Determining the concentration of 25(OH)D3 and 3-Epi25(OH)D3 separately is therefore important due to possible difference of effectiveness. However, further studies on the function and source of 3-Epi25(OH)D3 in humans are warranted.

Vitamin D3 has a plasma half-life of 4 to 12 h [9,10] and a circulating half-life of 12 to 24 h [11]. On the other hand, 25(OH)D2 and 25(OH)D3 have longer half-lives, 13 and 15 to 25 days, respectively [12,13,14,15]. The 25(OH)D is further hydroxylated to 1,25-dihydroxyvitamin D (1,25(OH)2D), the most potent physiologically active metabolite with a relatively short half-life of 4 to 6 h [16].

This suggests that measurements of 25(OH)D, 25(OH)D2, and 25(OH)D3 are better indicators of vitamin D status in the blood. Holick et al. have published a set of guidelines for the evaluation of Vitamin D deficiencies [17]. Blood 25(OH)D levels < 50 nmol/L are considered 25(OH)D-deficient, levels between 50 and 75 nmol/L are considered 25(OH)D-insufficient, and >75 nmol/L are considered 25(OH)D-sufficient [17,18,19,20].

Methods which only measure 25(OH)D3 and not 3-Epi25(OH)D3 may cause overestimation of 25(OH)D3 because both analytes would be determined as 25(OH)D3. To obtain accurate measurements of vitamin D levels in mothers and infants, a highly selective and sensitive quantification method for measuring vitamin D metabolites in blood and breastmilk is needed [21]. Thus, in this study, simple, sensitive, and selective liquid chromatography-tandem mass spectrometric (LC-MS/MS) methods were used for determination of 25(OH)D2, 25(OH)D3, and 3-epi-25-hydroxyvitamin D3 (3-Epi25(OH)D3) in plasma, breastmilk, and infant formula.

An automated sample preparation involving protein-crash and solid-phase extraction techniques was applied to ensure simple sample treatment, and reduced time and labor.

During pregnancy, the main source of vitamin D for the fetus is the mother, through the umbilical cord. Studies have reported correlation between maternal and infant cord blood 25(OH)D concentrations [22,23,24,25]. Thus, mothers with sufficient 25(OH)D during pregnancy can provide sufficient cord blood concentrations of 25(OH)D crossing the placenta [26,27]. However, vitamin D metabolites levels < 50 nmol/L have been observed in pregnant women and their offspring [28,29,30].

Pregnant women and infants are highly susceptible to vitamin D deficiency which has been associated with adverse health outcomes, such as pre-eclampsia, perinatal complications, postpartum depression, spontaneous abortion, emergency cesarean section delivery, oligohydramnios, polyhydramnios, and gestational diabetes [31,32]. As for the infants, vitamin D deficiency may cause a small-for-gestational age condition, preterm birth, low birth weight, stunting, impaired fetal bone formation, and rickets [31,32,33,34,35]. Accordingly, Norwegian maternal vitamin D < 30 nmol/L has been associated with lower offspring peak bone mass [36].

Personalized vitamin D supplementation during pregnancy and lactation has been suggested [37]. Monitoring vitamin D deficiency in Norwegian mother-infant pairs before and after childbirth is therefore of importance.

The aim of this study was to validate selective and sensitive LC-MS/MS methods for the analysis of vitamin D metabolites with automated sample preparation. These methods were applied to determine the concentration levels of Vitamin D metabolites in mother-infant pairs during the first six months of breastfeeding. Detection and quantification of 3-Epi25(OH)D3 allows evaluation of the impact of 3-Epi25(OH)D3 when assessing vitamin D metabolites status in plasma and breastmilk. The relationships between plasma vitamin D metabolites levels in mother-infant pairs and breastmilk levels were also examined.

2. Materials and Methods

2.1. Study Population and Design

From January 2016 until February 2017, pregnant women were recruited to participate in a two-armed randomized controlled intervention trial involving cod intake in pregnancy [38]. The study was registered on ClinicalTrials.gov (NCT02610959) in 17 November 2015. All participants were recruited through the womens’ clinic at Haukeland University Hospital in Norway. A total of 137 pregnant women were included in this secondary analysis. Details regarding the main study have been described elsewhere [38].

2.2. Biological Samples and Laboratory Analysis

Blood samples were obtained from mother-infant pairs. The mothers were requested to provide a sample of breastmilk at six weeks and three months postpartum. Breastmilk was collected at the beginning, middle, and end of a chosen feed. The three samples were then stored in a freezer until pick-up by study investigators or submission during the third-month follow-up visit. Samples were placed in freezer packs during transport. Upon arrival in the laboratory, samples were stored at –80 °C until analyzed as a pooled sample.

Meanwhile, blood sampling was conducted in mothers and infants at three and six months postpartum. Plasma samples from the participants were obtained by collecting blood into BD Vacutainer ® K2E 5.4 mg vials (Franklin Lakes, NJ, USA), centrifuged (1000–1300× g, 20 °C, 10 min) within 30 min, and the supernatant was stored at –80 °C until analyzed.

2.3. Laboratory Analysis

2.3.1. Chemical and Reagents

The standards 25(OH)D3, 25(OH)D2, 3-Epi25(OH)D3 and internal standard D6-25(OH)D3-(26,26,26,27,27,27-D6) were obtained from Cerilliant (Round Rock, TX, USA). The internal standards 25(OH)D2-(6,19,19-d3) and 3-Epi25(OH)D3-(6,19,19-d3), zink sulfate monohydrate, formic acid (analytical grade) and ammonium acetate were purchased from Sigma-Aldrich (St Louis, MO, USA).

2.3.2. Sample Preparation

All sample preparation and extraction process were performed using robotic a Dual Head MultiPurpose Sampler (MPS XL) equipped with an Anatune CF-100 Centrifuge Option, MicroLiter ITSP Option and Active WashStation [39,40] Using an automated system, samples were prepared by adding 80 μL of internal standards to aliquots of 200-μL samples. Protein-crash, centrifugation, and solid-phase extraction techniques were automated using MPS XL (Anatune, Cambridge, UK). The samples were precipitated with 200 μL zinc sulfate and 500 μL methanol.

Samples were then vortexed and centrifuged for 5 min. An aliquot of 500 μL of supernatant was loaded for solid phase extraction and eluted with 40 μL methanol. High purity water (18.2 million ohms, MΩ x cm) was added to the eluted sample prior to LC-MS/MS injection.

2.3.3. LC-MS/MS Procedure
Waters Quattro PremierTM/XE

LC-MS/MS conditions for the analysis of plasma samples were as follows. For chromatographic separation, acquity ultra performance liquid chromatography (UPLC) (Waters Corporation, Milford, MA, USA) was used. The system was equipped with a degasser, pump, a thermostated acquity sample manager and column oven. Twenty microliters of the sample was injected into the analytical column (Acquity UPLC, HSS PFP 1.8 µm, 2.1 × 100 mm, Waters, Milford, MA, USA). Two millimole per liter ammonium acetate with 0.1% formic acid was used as mobile phase A, while methanol with 0.3% formic acid was used as mobile phase B.

The Waters binary solvent manager was programmed as follows: 0–3.0 min, 30% A and 70% B; 3.5–5.0 min, 25% A and 75% B; 5.5–6.0 min, 2% A and 98% B; 6.5–8.0 min, 30% A and 70% B. All gradient steps were linear. For sample detection, a triple-quadrupole mass spectrometry system from Waters Quattro PremierTM/XE (Waters Corporation, Milford, MA, USA) was used, equipped with electrospray ion source. MS source parameters are as follows: capillary voltage, 3.0 kV; cone voltage, 15–20 V; source temperature, 120 °C; and cone gas flow rate, 15 L/h.

Nitrogen and argon were used as the cone and collision gases, respectively. Parent and fragment ions were detected in multiple-reaction monitoring (MRM) mode and the respective collision energies are listed in Appendix A. Data acquisition for all experiments was carried out with Masslynx V4.1 software (Waters, Milford, USA).

Agilent MassHunter

LC-MS/MS conditions for the analysis of plasma, breastmilk, and infant formula samples were as follows: For chromatographic separation, an Agilent 1290 UPLC (Agilent Technologies, Palo Alto, CA, USA) was used. The system was equipped with a degasser, pump, a thermostated autosampler, and column oven. Fifteen microliters of the sample was injected to the analytical column (Acquity UPLC, HSS PFP 1.8 µm, 2.1 × 100 mm, Waters, Milford, MA, USA). Two millimole ammonium acetate with 0.1% formic acid was used as mobile phase A, while methanol with 0.3% formic acid was used as mobile phase B.

The Agilent 1290 pump was programmed as follows: 0–3.0 min, 35% A and 65% B; 3.5–4.5 min, 30% A and 70% B; 5.0–6.4 min, 25% A and 75% B; 6.5–8.0 min, 2% A and 98% B; 8.1–9.5 min, 35% A and 65% B. All gradient steps were linear. For sample detection, a triple-quadrupole mass spectrometry system from Agilent 6495B (Agilent Technologies, Santa Clara, CA, USA) was used, equipped with jet stream electronspray ion source. Nitrogen was used as the drying gas, sheath gas, nebulizing gas, and collision gas.

The drying and sheath gas temperatures were 200 °C and 300 °C, respectively. The following settings were used: drying gas flow 13 L/min and sheath gas flow: 10 L/min, nebulizer pressure: 40 psi, capillary voltage: 5000 V, and nozzle voltage: 2000 V. Parent and fragment ions were detected in multiple-reaction monitoring (MRM) mode and the respective collision energies are listed in Appendix A. The Agilent MassHunter Workstation software version B.08.00. (Agilent Technologies, Santa Clara, CA, USA) was used to control the LC-MS system, peak integration, quantitation, and calculation.

2.4. LC-MS/MS Assay Validation. Linearity, Sensitivity, Precision, Accuracy, and Recovery

Method validation was performed according to bioanalytical method guidelines for biological samples and industry [41,42]. The linearity of the two methods were assessed using six concentration levels of 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3, analyzed for ten consecutive days. Sensitivity was determined by calculating the lower limit of detection (LOD) and lower limit of quantification (LOQ). The LOD was determined using the concentration of the lowest diluted sample with signal-to-noise ratio at approximately three. The LOQ was set as the concentration of the lowest standard.

Precision and accuracy were determined by an intra-day and inter-day analysis of in-house quality control samples. Precision was calculated as relative standard deviation (RSD) of experimental concentrations, and the criteria for acceptability was 15% RSD, except for the LOQ where it should not have exceeded 20%. Accuracy was calculated as the comparison between the measured values and nominal sample concentrations. The criteria for acceptability were 15% and 20% (at LOQ) deviation from the nominal values. An in-house quality control plasma sample consisting of 25(OH)D3 at a medium level was used to estimate intra-assay and inter-assay precision and accuracy of 25(OH)D3 for the Waters Quattro PremierTM/XE method.

For the Agilent 6495B method, three concentration levels (low, medium, and high) of in-house quality control samples were prepared in plasma, breastmilk, and infant formula. The baseline concentrations of 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 were measured prior to addition of the standard solutions. The 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 were then assayed for intra-assay precision and accuracy for ten consecutive days. The inter-assay precision was evaluated for 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3. Accuracy was determined using commercial quality control (QC) plasma samples; standard reference materials (SRM) 972a-C level 1, SRM 972a-C level 2, SRM 972a-C level 3, and SRM 972a-C level 4 Vitamin D Metabolites in frozen human serum.

SRM 1950 metabolites in frozen human plasma were also used. In addition, QC serum samples were also included (SRM 972 level 2, SRM 1950, and SRM 2972). The recovery of the analytes was studied by spiking the samples (plasma, breastmilk, and infant formula) with standard solutions at three levels. Recovery was evaluated by comparing the baseline (unspiked) and spiked samples at three levels (low, medium, and high). Recovery was then calculated by comparing the measured concentration of the prepared samples with the nominal value (baseline and spiked concentration) representing 100% recovery.

2.5. Data Analysis and Statistical Analyses

LC-MS/MS data were analyzed by Agilent MassHunter 8.0 Quan Browser (Agilent Technologies, Santa Clara, CA, USA). The levels of vitamin D metabolites are presented as mean and standard deviation (SD). To examine differences between status and categories paired Student’s t-test was used. Pearson’s correlation coefficients were used to assess associations between continuous variables. A 2-sided p-value of <0.05 was considered significant. All statistical analyses were performed using IBM SPSS Statistics 26 (IBM Corp., Armonk, NY, USA).

3. Results

3.1. Evaluation of the LC-MS/MS Assay

The LC MS/MS methods for the determination of 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 using Waters Quattro PremierTM/XE, and 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 using Agilent 6495B were developed and validated. The base peak ions and fragments of 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 ([M + H]+) are shown in Appendix A. The Waters Quattro PremierTM/XE is equipped with an electronspray ion source and Agilent 6495B is equipped with a jet stream electronspray ion source. The selected reaction monitoring was based on the mass-to-charge ratio (m/z).

The Agilent 6495B MRM chromatograms of the analytes are shown in the Supplementary Material Figure S1. It provided separation between metabolites, with 25(OH)D3, 25(OH)D2, and 3-Epi25(OH)D3 eluting at 6.95, 7.18, and 7.19 min, respectively. The same was observed using Waters Quattro PremierTM/XE with the mass-to-charge ratio (m/z) and fragmentations distinguished for Waters Quattro PremierTM/XE (data not shown).

The Waters Quattro PremierTM/XE method was linear for 25(OH)D3, 25(OH)D2, and 3-Epi25(OH)D3 as shown in Table 1, and the best fits were indicated by a correlation coefficient (r) of 0.99 for 25(OH)D3, 25(OH)D2, and 3-Epi25(OH)D3. The Agilent 6495B method was linear for 25(OH)D3, 25(OH)D2, and 3-Epi25(OH)D3 with correlation coefficients ≥ 0.999. The standard curves are considered acceptable when r is >0.99. The limit of detection (LOD) and limit of quantification (LOQ) were determined to evaluate sensitivity of the method and are shown in Table 1a for Quattro PremierTM/XE and Table 1b for Agilent 6495B.

The intra-assay and inter-assay precision and accuracy are summarized in Table 2 and Table 3. Relative standard deviation (RSD) values for quality control (QC) plasma, breastmilk, and infant formula samples measured with Waters Quattro PremierTM/XE and with Agilent 6495B were below 20% for 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3, respectively. For low concentration levels, RSD value for breastmilk was 30% for 3-Epi25(OH)D3. The methods showed accuracy within 20%, as shown in Appendix B. The recoveries of the analytes obtained with the use of automated solid phase extraction and filtration autosampler, Gerstel multi-purpose sampler, ranged from 88% to 120%, 72% to 103% and 81% to 129% for plasma, breastmilk, and infant formula, respectively as shown in Appendix C.

3.2. Vitamin D Levels at Each Time-Point for Maternal and Infant Plasma Samples

Table 4 shows the number of samples collected. The samples were divided into 3 diagnostic categories according to 25(OH)D status: deficient (25(OH)D < 50 nmol/L), insufficient (50 nmol/L < 25(OH)D < 75 nmol/L), and sufficient (25(OH)D ≥ 75 nmol/L). The 3-Epi25(OH)D3 was not included in the calculations. Eighteen percent and 30.6% of the measured breastmilk samples had 25(OH)D levels lower than 50 nmol/L, 39.3% and 40% had levels between 50 and 75 nmol/L, and 42.7% and 29.4% had levels equal to or more than 75 nmol/L at 6 weeks and 3 months, respectively.

Prevalence of 25(OH)D deficiency was determined in mother-infant pairs (Table 4). At 3 months, 63% of maternal 25(OH)D plasma levels were less than 75 nmol/L 25(OH)D. Accordingly, 31% of the infants were categorized as vitamin D deficient (25(OH)D < 50 nmol/L).

3.3. Maternal and Infant Plasma Vitamin D Metabolites Concentration at 3 and 6 Months

The 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 plasma levels of the mothers and their infants, and the breastmilk levels of vitamin D metabolites at 6 weeks and 3 months are presented in Table 5. At 3 months, the concentration of 3-Epi25(OH)D3 contributed 11% and 24% of the total 25(OH)D3 in infants’ plasma and breastmilk, respectively.

3.4. Correlation between Vitamin D Metabolites and Mother and Infant Levels of Vitamin D Metabolites

At 6 weeks, a positive association between breastmilk concentration of 25(OH)D3 and 3-Epi25(OH)D3 (p < 0.01; r = 0.711, Figure 1a) was observed. The same was seen at 3 months (p < 0.01; r = 0.805, Figure 1b). There was also a positive association observed between the infant’s plasma levels of 25(OH)D3 and 3-Epi25(OH)D3 (p < 0.01, r = 0.678) at 3 months. A positive association between mother and infant plasma levels of 25(OH)D3 was observed (p < 0.01; r = 0.555, Figure 2).

4. Discussion

In this study, a robotic autosampler was used to automate sample preparation prior to LC-MS/MS analysis which included protein-crash, solid-phase extraction techniques and dilution. This ensured reproducibility, simple sample treatment, and reduced time and labor and costs. Two simple, sensitive, and selective LC-MS/MS methods were then used to separate and detect 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3. The concentrations of 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 in plasma were measured with Waters Quattro PremierTM/XE. Breastmilk samples were measured with Agilent 6495B which resulted in an improved detection limit.

Both LC-MS/MS methods separated 3-Epi25(OH)D3 from 25(OH)D3 for accurate detection and measurement of 25(OH)D3. Our validation showed a concentration-response relationship fitted with a simple regression model. The accuracy and inter-precision were within the acceptable criteria of RSD at 15% for 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 in plasma, breastmilk, and infant formula [42] with an exception of the measured inter-precision RSD for 25(OH)D2 in infant formula (17%.) At LOQ levels, the 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 were also within the acceptable criteria of 20% RSD.

The intra-precision was within acceptable criteria of 15% RSD. This also applies at LOQ levels with an exception for 3-Epi25(OH)D3 in breastmilk with an RSD of 30%. These two LC-MS/MS methods were used to determine the vitamin D status in Norwegian mother-infant pairs.

The LC-MS/MS methods presented in this study distinguished between 25(OH)D3 and 3-Epi25(OH)D3. At 3 months, the C-3 epimer contributed 11% of the total 25(OH)D in infants’ plasma. Thus, if 3-Epi25(OH)D3 was not distinguished from 25(OH)D3, only 25% of the infants are categorized as vitamin D deficient instead of 31%. The observed positive correlation between infants’ 25(OH)D3 and 3-Epi25(OH)D3 at 3 months suggests possible overestimation of 25(OH)D3 and more likely, misclassification of vitamin D in studies using methods that only measure 25(OH)D3 [43].

In breastmilk, at 3 and 6 months, the 3-Epi25(OH)D3 contributed 24% and 27% of the total 25(OH)D, respectively. In addition, positive associations were also observed between 25(OH)D3 and 3-Epi25(OH)D3 in breastmilk at 6 weeks and 3 months. Accordingly, studies have shown positive correlation between 25(OH)D3 and 3-Epi25(OH)D3 in both maternal and cord blood [43,44]. This may imply maternal cord blood and breastmilk as a possible source of 3-Epi25(OH)D3 in infants. Studies on epimers function and source are warranted.

Infants are highly dependent on their mother’s cord 25(OH)D concentrations, which is usually 60–80% of maternal values at delivery [45,46]. A survey of 25(OH)D levels in pregnant Black South Africans gave a mean of 57.0 nmol/L, while 41.9 nmol/L was found in the cord blood [47]. On the other hand, the measured concentrations of 25(OH)D in light-skinned pregnant women at northern latitudes was 71.4 nmol/L, while 39.2 nmol/L was recorded for cord blood [48].

Another study observed that in pregnant women, the mean 25(OH)D concentrations were 41 nmol/L and 50.7 nmol/L during the first trimester and in the umbilical cord, respectively [49]. Meanwhile, vitamin D deficiency appears to be common in mothers and their infants in New Zealand, with mean cord blood 25(OH)D value of 41 nmol/L [50]. In general, studies suggest that low levels of 25(OH)D in mothers are likely to be reflected in their infants. In this study, maternal plasma levels, at 3 and 6 months, 13% and 14% of mothers were categorized as deficient (25(OH)D < 50 nmol/L), 51% and 48% as insufficient (50 nmol/L < 25(OH)D < 75 nmol/L), and 37% and 38% as sufficient (25(OH)D ≥ 75 nmol/L), respectively.

However, 31% and 29% of the infants had deficient and insufficient 25(OH)D status at 3 months, respectively. Vitamin D body stored in infants can decline by 50% over less than a month, hence without another source of vitamin D, vitamin D deficiency can develop [51]. This may explain the higher prevalence of 25(OH)D deficiency in infants compared with mothers.

A positive association between maternal 25(OH)D plasma levels and infant 25(OH)D plasma levels at 3 months was observed. The maternal and infant 25(OH)D3 plasma concentrations were 69.6 (±16.3) nmol/L and 64.9 (±29.1) nmol/L, respectively. Hence, measured infant plasma level of 25(OH)D at 3 months may reflect the 25(OH)D transferred from mother to infant during pregnancy and start of vitamin D supplement. There was a rise of infant plasma 25(OH)D concentration observed from 3 months to 6 months. Accordingly, a positive correlation between maternal and infant plasma was no longer observed suggesting an increase in 25(OH)D level as a possible result of vitamin D supplementation and start of fortified complementary feeding.

In Norway, vitamin D supplements, such as vitamin D drops or cod liver oil, are recommended for all infants from the age of four weeks. A Norwegian population study showed that 92% of the children at age 9-16 months were given vitamin D containing supplements [30]. Here, results showed decreased prevalence of 25(OH)D deficiency in infants, from 3 months (31%) to 6 months (8%). Even with the decrease in vitamin D deficiency prevalence at 6 months, vitamin D deficiency originating in the intrauterine period or immediately after birth to 3 months may still result in adverse effects on skeletal development [49,52].

Correspondingly, in vitamin D-deficient infants, rickets usually develops between the age of 6 months and 2 years [53]. Interestingly, the prevalence of infants categorized as 25(OH)D sufficient at 3 and 6 months had a minor change: 40% and 44%, respectively.

The WHO’s recommendation of exclusive breastfeeding for 6 months may further lead to vitamin D deficiency among infants [54,55]. Although breastmilk is rich in essential nutrients for the earliest life stage, it contains about three-times-less vitamin D than the maternal circulating concentration [56]. A study showed that during the third trimester of pregnancy, maternal 25(OH)D was 60 nmol/L, and the breastmilk level at delivery was 1.26 nmol/L [57]. As for non-Vitamin-D-supplemented Norwegian mothers and infants, a study reported no change in mother’s plasma levels of 25(OH)D (58 to 42 nmol/L) between 4 days and 6 weeks after birth.

However, infant’s plasma levels dropped from 26 to 15 nmol/L, thus, suggesting that Norwegian mothers have insufficient 25(OH)D, and therefore that breastmilk is inadequate as a lone source of vitamin D, and supplementation of 10 µg per day is recommended [18,58,59].

There was no observed change in maternal 25(OH)D plasma levels between 3 and 6 months. The prevalence of maternal vitamin D deficiency at 3 and 6 months was almost the same. Likewise, another study showed that the measured 25(OH)D3 of 67 nmol/L did not change between 2 weeks and 12 months postpartum [60]. Thus, maternal vitamin status was maintained through 6 months of breastfeeding and possibly just enough for their own needs. These results do not support the theory that maternal vitamin D status decreases due to a transfer of vitamin D from the mother to infant through breastmilk [61].

Accordingly, breastmilk 25(OH)D2 remained unchanged between 6 weeks and 3 months. In contrast, breastmilk concentration of 25(OH)D3 decreased from 6 weeks to 3 months. Thus, decreased level of 25(OH)D3 in breastmilk suggests that transfer of 25(OH)D3 to breastmilk production was not prioritized. Studies have shown that vitamin D is readily transferred into breastmilk, while 25(OH)D is transferred very poorly, and 1,25 (OH)2D is not transferred at all [62]. This may explain the lack of association between maternal plasma and breastmilk 25(OH)D3 concentration.

Thus, 25(OH)D in the blood may not be a good reflection of the available amount of vitamin D that can be transferred to infants through breastfeeding. Accordingly, studies have also reported that UV exposure and increased maternal vitamin D supplementation showed minimal changes in 25(OH)D concentrations but a profound increase in breastmilk concentration of vitamin D was observed [56,63]. Thus, measurement of vitamin D3 and vitamin D2 in breastmilk and plasma samples in this study population is warranted.

In this study, an automated robust sample preparation was used. The methods distinguished between 25(OH)D3 and 3 epimer of 25(OH)D3, 3-Epi25(OH)D3 preventing overestimation of 25(OH)D3 and misclassification of vitamin D status. However, a limitation in this study is that two different LC-MS/MS methods were used, resulting in different validation parameters and LOD. Anyhow, the challenge with the overestimation of 25(OH)D3 has been addressed and managed resulting in a reliable quantification of 25(OH)D. Here, we provided novel results of 25(OH)D status in Norwegian mother-infant pairs during the first 6 months of breast feeding.

A possible source of 3-epi-25(OH)2D3 was also discussed. Prevalence of vitamin D deficiency (25(OH)D < 50 nmol/L) among Norwegian mother-infant pairs was determined. Surprisingly, a prevalence of 31% 25(OH)D deficiency was observed among infants at three months. Studies suggest the importance of vitamin D supplementation during pregnancy, and the breastfeeding period to ensure the achievement of the recommended 25(OH)D level of at least 75 nmol/L in mothers and their infants [17,20,34,64,65].

Vitamin D supplementation in pregnant women seems to reduce the risk of pre-eclampsia, gestational diabetes, low birthweight, and severe postpartum hemorrhage [66]. Wide ranges of vitamin D doses, from 400 to 2000 IU have been recommended [17,67,68,69]. However, some doses may not result in optimal 25(OH)D levels during pregnancy. This may be due to interindividual variability in vitamin D metabolism and other factors [70,71]. Thus, establishing a personalized dosing regimen has been suggested [37].

5. Conclusions

In summary, two simple, sensitive, and selective LC-MS/MS methods enable reliable quantification of 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3. The automated sample preparation makes it suitable for routine laboratory analysis of plasma, breastmilk, and infant formula. This study demonstrated the importance of separating 3-Epi25(OH)D3 from 25(OH)D3 to prevent overestimation of 25(OH)D3 and misclassification of vitamin D status. Accordingly, at 3 months, 13% and 31% of the mothers and infants were categorized as vitamin D deficient (25(OH)D < 50 nmol/L), respectively. Thus, we suggest monitoring vitamin D metabolites in infant, maternal plasma, and breastmilk to ensure adequate levels in both mother and infant in the first 6 months of infant life.

Further studies on personalized supplementation with vitamin D during pregnancy and breastfeeding are warranted.

Acknowledgments

We thank Elisabeth Ødegård for technical support and Zylla Marie Oane for proofreading the manuscript. We also thank Jojo Tibon for comments and feedback on the manuscript.

Supplementary Materials

The following are available online at https://www.mdpi.com/2072-6643/12/8/2271/s1, Figure S1. Representative chromatograms of 25(OH)D3 and 3-Epi25(OH)D3 8(a.) and 25(OH)D2 (b.).

Click here for additional data file.

Supplement file at the original source — open the original paper. This file is not included in this text import.

Author Contributions

M.K., L.D. and M.W.M. study design, sample collection and conducted research; J.G. and T.B. LC-MS analyzes and data acquisition; A.B., M.K. and M.W.M. project administration; M.K., M.W.M. and J.G. analyzed data or performed statistical analysis; J.G. original draft preparation and writing. All authors have read and agreed to the published version of the manuscript.

Funding

The Mommy’s Food study is financially supported by The Norwegian Seafood Research Fund (http://www.fhf.no/). The funder had no role in the design or the decision to publish this protocol.

Conflicts of Interest

The authors declare no conflict of interest.

Appendix A

Table A1

Multiple-reaction monitoring (MRM) mode and the respective dwell time, cone voltage, and collision energy used in Waters Quattro PremierTM/XE (a) and in Agilent 6495B (b).

a. Waters Quattro PremierTM/XE
Analytes Parention 1 Daughterion 1 Dwell Time 2 Cone Collision Energy 3
25(OH) D3/3-Epi25(OH)D3401.35159.100.052028
25(OH) D3/3-Epi25(OH)D3401.35383.200.05209
d3-3-Epi25(OH)D3404.36162.100.052522
d6-25(OH)D3407.36159.100.052026
25(OH)D2413.35159.000.052026
25(OH)D2413.35395.200.052010
d3-25(OH)D2416.30162.000.052026
1.25(OH)D3434.30399.300.051510
d6-1.25(OH)D3440.3405.300.051510
b. Agilent 6495B
Analytes Parention 1 Daughterion 1 Dwell Time 2 Cone Collision Energy 3
25(OH) D3/3-Epi25(OH)D3401.3365.42555
25(OH) D3/3-Epi25(OH)D3401.3383.42555
d3-3-Epi25(OH)D3404.4368.42555
d3-3-Epi25(OH)D3404.4386.42555
d6-25(OH)D3407.4371.42555
d6-25(OH)D3407.4389.42555
25(OH)D2413.3395.32555
25(OH)D2413.3355.42555
d3-25(OH)D2416.4398.32555
d3-25(OH)D2416.4358.52555
1.25(OH)D3434.6399.42558
1.25(OH)D3434.6381.72558
d6-1.25(OH)D3440.6405.72555
d6-1.25(OH)D3440.6387.52555

1 m/z; 2 ms; 3 volts.

Appendix B

Table A2

Accuracy for the analysis of 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 in plasma and serum using (a) Waters Quattro PremierTM/XE and (b) Agilent 6495B.

Samples Analytes
a. Waters Quattro PremierTM/XE
Serum (n = 3)1,25(OH)2D325(OH)D2 25(OH)D33-Epi25(OH)D3
SRM 972a-C Level 2
 Concentration (nmol/L)--30.8-
 Accuracy (%) 106
SRM 972a-C Level 3
 Concentration (nmol/L)-32.349.4-
 Accuracy (%) 101110
SRM 972a-C Level 4
 Concentration (nmol/L)--73.465.8
 Accuracy (%) 111101
SRM 1950
 Concentration (nmol/L)--61.8-
 Accuracy (%) 108
SRM 2972
 Concentration (nmol/L)--835.6-
 Accuracy (%) 106
b. Agilent 6495B
Plasma (n = 2) 1,25(OH)2D3 25(OH)D2 25(OH)D3 3-Epi25(OH)D3
SRM 1950 Level 2
 Concentration (nmol/L)--61.8-
 Accuracy (%) 104
Serum (n = 2)1,25(OH)2D325(OH)D2 25(OH)D33-Epi25(OH)D3
SRM 972a-C Level 1
 Concentration (nmol/L)--71.84.5
 Accuracy (%) 102103
SRM 972a-C Level 2
 Concentration (nmol/L)--45.13.2
 Accuracy (%) 113106
SRM 972a-C Level 3
 Concentration (nmol/L)-32.349.52.9
 Accuracy (%) 1009799
SRM 972a-C Level 4
 Concentration (nmol/L)--73.464.8
 Accuracy (%) 102108

Each value is presented as mean.

Appendix C

Table A3

Recovery (n = 10) of vitamin D metabolites in plasma, breastmilk, and infant formula at inter-day.

SamplesAnalytes
Plasma (n = 10)25(OH)D2 25(OH)D33-Epi25(OH)D3
Low
 Added (nmol/L)26.4746.3627.96
 Measured (nmol/L)30.22 ± 2.66 42.93 ± 3.4134.50 ± 2.18
 Recovery (%)11493128
Medium
 Added (nmol/L)74.9496.2851.92
 Measured (nmol/L)71.19 ± 4.19 102.63 ± 5.5948.18 ± 3.59
 Recovery (%)9510793
High
 Added (nmol/L)121.17146.20101.84
 Measured (nmol/L)115.33 ± 8.95162.75 ± 8.99 99.94 ± 5.59
 Recovery (%)9511198
Breastmilk (n = 10)25(OH)D2 25(OH)D33-Epi25(OH)D3
Low
 Added (nmol/L)<LOQ15.188.07
 Measured (nmol/L) 12.04 ± 2.045.83 ± 1.73
 Recovery (%) 7972
Medium
 Added (nmol/L)48.7465.1057.99
 Measured (nmol/L)39.89 ± 2.7565.01 ± 5.1945.74 ± 2.64
 Recovery (%)8210079
High
 Added (nmol/L)97.20111.50107.91
 Measured (nmol/L)97.88 ± 4.63114.80 ± 7.9891.98 ± 8.98
 Recovery (%)10110385
Infant formula (n = 10)25(OH)D2 25(OH)D33-Epi25(OH)D3
Low
 Added (nmol/L)<LOQ <LOQ<LOQ
 Measured (nmol/L)
 Recovery (%)
Medium
 Added (nmol/L)26.4851.5324.96
 Measured (nmol/L)21.37 ± 2.35 66.63 ± 2.71 32.22 ± 1.80
 Recovery (%)81129129
High
 Added (nmol/L)99.18101.4599.84
 Measured (nmol/L)93.17 ± 8.67112.08 ± 4.15107.10 ± 3.61
 Recovery (%)94110107

Recovery (%) = 100 × measured concentration/amount added.

References

1. Dhamo B. Miliku K. Voortman T. Tiemeier H. Jaddoe V.W. Wolvius E.B. Ongkosuwito E.M. The Associations of Maternal and Neonatal Vitamin D with Dental Development in Childhood Curr. Dev. Nutr. 2019 3 nzy100 10.1093/cdn/nzy100 30931425 PMC6435444
2. van Halteren A.G. van Etten E. de Jong E.C. Bouillon R. Roep B.O. Mathieu C. Redirection of human autoreactive T-cells Upon interaction with dendritic cells modulated by TX527, an analog of 1,25 dihydroxyvitamin D(3) Diabetes 2002 51 2119 2125 10.2337/diabetes.51.7.2119 12086941
3. Gonzalez-Gross M. Valtuena J. Breidenassel C. Moreno L.A. Ferrari M. Kersting M. De Henauw S. Gottrand F. Azzini E. Widhalm K. Vitamin D status among adolescents in Europe: The Healthy Lifestyle in Europe by Nutrition in Adolescence study Br. J. Nutr. 2012 107 755 764 10.1017/S0007114511003527 21846429
4. Totland T.H. Melnæs B.K. Lundberg-Hallen N. Helland-Kigen K.M. Lund-Blix N.A. Myhre J.B. Johansen A.M.W. Løken E.B. Andersen L.F. Norkost 3 En landsomfattende kostholdsundersøkelse blant menn og kvinner i Norge i alderen 18-70 år, 2010–11 Oslo Helsedir. 2012 67 25 33
5. Kamao M. Tatematsu S. Hatakeyama S. Sakaki T. Sawada N. Inouye K. Ozono K. Kubodera N. Reddy G.S. Okano T. C-3 epimerization of vitamin D3 metabolites and further metabolism of C-3 epimers: 25-hydroxyvitamin D3 is metabolized to 3-epi-25-hydroxyvitamin D3 and subsequently metabolized through C-1alpha or C-24 hydroxylation J. Biol. Chem. 2004 279 15897 15907 10.1074/jbc.M311473200 14757768
6. Bianchini C. Lavery P. Agellon S. Weiler H.A. The generation of C-3alpha epimer of 25-hydroxyvitamin D and its biological effects on bone mineral density in adult rodents Calcif. Tissue Int. 2015 96 453 464 10.1007/s00223-015-9973-9 25712257
7. Fleet J.C. Bradley J. Reddy G.S. Ray R. Wood R.J. 1α, 25-(OH)2-vitamin D3 analogs with minimal in vivo calcemic activity can stimulate significant transepithelial calcium transport and mRNA expression in vitro Arch. Biochem. Biophys. 1996 329 228 234 10.1006/abbi.1996.0213 8638956
8. Al-Zohily B. Al-Menhali A. Gariballa S. Haq A. Shah I. Epimers of Vitamin D: A Review Int. J. Mol. Sci. 2020 21 470 10.3390/ijms21020470 PMC7013384 31940808
9. Mawer E.B. Lumb G.A. Schaefer K. Stanbury S.W. Metabolism of Isotopically Labelled Vitamin-D3 in Man—Influence of State of Vitamin-D Nutrition Clin. Sci. 1971 40 39 53 10.1042/cs0400039 4321723
10. Smith J.E. Goodman D.W.S. The turnover and transport of vitamin D and of a polar metabolite with the properties of 25-hydroxycholecalciferol in human plasma J. Clin. Investig. 1971 50 A86 10.1172/JCI106710 PMC292150 4330006
11. Clemens T.L. Adams J.S. Nolan J.M. Holick M.F. Measurement of Circulating Vitamin-D in Man Clin. Chim. Acta 1982 121 301 308 10.1016/0009-8981(82)90239-X 6286167
12. Jones G. Pharmacokinetics of vitamin D toxicity Am. J. Clin. Nutr. 2008 88 582S 586S 10.1093/ajcn/88.2.582S 18689406
13. Jones K.S. Assar S. Harnpanich D. Bouillon R. Lambrechts D. Prentice A. Schoenmakers I. 25(OH)D2 Half-Life Is Shorter Than 25(OH)D3 Half-Life and Is Influenced by DBP Concentration and Genotype J. Clin. Endocrinol. Metab. 2014 99 3373 3381 10.1210/jc.2014-1714 24885631 PMC4207933
14. Oliveri B. Mastaglia S.R. Brito G.M. Seijo M. Keller G.A. Somoza J. Diez R.A. Di Girolamo G. Vitamin D3 seems more appropriate than D2 to sustain adequate levels of 25OHD: A pharmacokinetic approach Eur. J. Clin. Nutr. 2015 69 697 702 10.1038/ejcn.2015.16 25782422
15. Lips P. Relative value of 25(OH)D and 1,25(OH)2D measurements J. Bone Miner. Res. 2007 22 1668 1671 10.1359/jbmr.070716 17645404
16. Kumar R. The metabolism and mechanism of action of 1,25-dihydroxyvitamin D3 Kidney Int. 1986 30 793 803 10.1038/ki.1986.258 3029498
17. Holick M.F. Binkley N.C. Bischoff-Ferrari H.A. Gordon C.M. Hanley D.A. Heaney R.P. Murad M.H. Weaver C.M. Endocrine S. Evaluation, treatment, and prevention of vitamin D deficiency: An Endocrine Society clinical practice guideline J. Clin. Endocrinol. Metab. 2011 96 1911 1930 10.1210/jc.2011-0385 21646368
19. Nordic Nutrition Recommendations 2012 Available online: https://www.norden.org/en/publication/nordic-nutrition-recommendations-2012(accessed on 14 April 2020)
20. Lips P. Which circulating level of 25-hydroxyvitamin D is appropriate? J. Steroid. Biochem. Mol. Biol. 2004 89 611 614 10.1016/j.jsbmb.2004.03.040 15225848
21. van den Ouweland J.M. Beijers A.M. van Daal H. Overestimation of 25-hydroxyvitamin D3 by increased ionisation efficiency of 3-epi-25-hydroxyvitamin D3 in LC-MS/MS methods not separating both metabolites as determined by an LC-MS/MS method for separate quantification of 25-hydroxyvitamin D3, 3-epi-25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum J. Chromatogr. B Anal. Technol. Biomed. Life Sci. 2014 967 195 202 10.1016/j.jchromb.2014.07.021 25125396
22. Bouillon R. Van Baelen H. De Moor P. 25-hydroxyvitamin D and its binding protein in maternal and cord serum J. Clin. Endocrinol. Metab. 1977 45 679 684 10.1210/jcem-45-4-679 914972
23. Bouillon R. Van Assche F.A. Van Baelen H. Heyns W. De Moor P. Influence of the vitamin D-binding protein on the serum concentration of 1,25-dihydroxyvitamin D3. Significance of the free 1,25-dihydroxyvitamin D3 concentration J. Clin. Investig. 1981 67 589 596 10.1172/JCI110072 6894152 PMC370606
24. Markestad T. Aksnes L. Ulstein M. Aarskog D. 25-Hydroxyvitamin D and 1,25-dihydroxyvitamin D of D2 and D3 origin in maternal and umbilical cord serum after vitamin D2 supplementation in human pregnancy Am. J. Clin. Nutr. 1984 40 1057 1063 10.1093/ajcn/40.5.1057 6333810
25. Hollis B.W. Johnson D. Hulsey T.C. Ebeling M. Wagner C.L. Vitamin D supplementation during pregnancy: Double-blind, randomized clinical trial of safety and effectiveness J. Bone Miner. Res. 2011 26 2341 2357 10.1002/jbmr.463 21706518 PMC3183324
26. Hillman L.S. Haddad J.G. Human perinatal vitamin D metabolism. I. 25-Hydroxyvitamin D in maternal and cord blood J. Pediatr. 1974 84 742 749 10.1016/S0022-3476(74)80024-7 4820711
27. Kovacs C.S. Vitamin D in pregnancy and lactation: Maternal, fetal, and neonatal outcomes from human and animal studies Am. J. Clin. Nutr. 2008 88 520S 528S 10.1093/ajcn/88.2.520S 18689394
28. Abbasian M. Chaman R. Amiri M. Ajami M.E. Jafari-Koshki T. Rohani H. Taghavi-Shahri S.M. Sadeghi E. Raei M. Vitamin D Deficiency in Pregnant Women and Their Neonates Glob. J. Health Sci. 2016 8 83 10.5539/gjhs.v8n9p83 PMC5064090 27157170
29. Lips P. Cashman K.D. Lamberg-Allardt C. Bischoff-Ferrari H.A. Obermayer-Pietsch B.R. Bianchi M. Stepan J. El-Hajj Fuleihan G. Bouillon R. Management of Endocrine Disease: Current vitamin D status in European and Middle East countries and strategies to prevent vitamin D deficiency; a position statement of the European Calcified Tissue Society Eur. J. Endocrinol. 2019 180 23 54 10.1530/EJE-18-0736 30721133
30. Madar A.A. Gundersen T.E. Haug A.M. Meyer H.E. Vitamin D supplementation and vitamin D status in children of immigrant background in Norway Public Health Nutr. 2017 20 2887 2892 10.1017/S136898001700180X 28789713 PMC10261310
31. van der Pligt P. Willcox J. Szymlek-Gay E.A. Murray E. Worsley A. Daly R.M. Associations of Maternal Vitamin D Deficiency with Pregnancy and Neonatal Complications in Developing Countries: A Systematic Review Nutrients 2018 10 640 10.3390/nu10050640 PMC5986519 29783717
32. Palacios C. Trak-Fellermeier M.A. Martinez R.X. Lopez-Perez L. Lips P. Salisi J.A. John J.C. Pena-Rosas J.P. Regimens of vitamin D supplementation for women during pregnancy Cochrane Database Syst. Rev. 2019 10 30 10.1002/14651858.CD013446 PMC6776191 31581312
33. Cashman K.D. Vitamin D in childhood and adolescence Postgrad. Med. J. 2007 83 230 235 10.1136/pgmj.2006.052787 17403948 PMC2600028
34. Wagner C.L. Greer F.R. American Academy of Pediatrics Section on B., American Academy of Pediatrics Committee on N. Prevention of rickets and vitamin D deficiency in infants, children, and adolescents Pediatrics 2008 122 1142 1152 10.1542/peds.2008-1862 18977996
35. Mahon P. Harvey N. Crozier S. Inskip H. Robinson S. Arden N. Swaminathan R. Cooper C. Godfrey K. Group S.W.S.S. Low maternal vitamin D status and fetal bone development: Cohort study J. Bone Miner. Res. 2010 25 14 19 10.1359/jbmr.090701 19580464 PMC4768344
36. Gustafsson M.K. Romundstad P.R. Stafne S.N. Helvik A.S. Stunes A.K. Morkved S. Salvesen K.A. Thorsby P.M. Syversen U. Alterations in the vitamin D endocrine system during pregnancy: A longitudinal study of 855 healthy Norwegian women PLoS ONE 2018 13 e0195041 10.1371/journal.pone.0195041 29641551 PMC5895009
37. Moon R.J. Davies J.H. Cooper C. Harvey N.C. Vitamin D, and Maternal and Child Health Calcif. Tissue Int. 2020 106 30 46 10.1007/s00223-019-00560-x 31089772 PMC7019685
38. Markhus M.W. Kvestad I. Midtbo L.K. Nerhus I. Odegaard E.R. Graff I.E. Lie O. Dahl L. Hysing M. Kjellevold M. Effects of cod intake in pregnancy on iodine nutrition and infant development: Study protocol for Mommy’s Food—A randomized controlled trial BMC Nutr. 2018 4 7 10.1186/s40795-018-0215-1 32153871 PMC7050745
39. Roberts P.H. Online Automated Protein Crash, Solid Phase Extraction and Analysis of Vitamin D in Serum Using Instrument Top Sample Prep (ITSP), Gerstel Multi Purpose Sampler and Agilent LC-MS/MS Available online: https://www.itspsolutions.com/sites/default/files/Anatune%20Vitamin%20D%20in%20Serum.pdf(accessed on 3 April 2020)
40. Foster D. Cabrices O. Pfannkoch E.A. Roberts P. Automated Extraction of Vitamin D Metabolites from Serum Available online: https://grupobiomaster.com/wp-content/uploads/2015/01/162.pdf(accessed on 3 April 2020)
41. Guideline on Bioanalytical Method Validation Available online: https://www.ema.europa.eu/en/documents/scientific-guideline/guideline-bioanalytical-method-validation_en.pdf(accessed on 3 April 2020)
42. US Department of Health and Human Services Bioanalytical Method Validation Guidance for Industry Available online: https://www.fda.gov/files/drugs/published/Bioanalytical-Method-Validation-Guidance-for-Industry.pdf(accessed on 3 April 2020)
43. Aghajafari F. Field C.J. Rabi D. Kaplan B.J. Maggiore J.A. O’Beirne M. Hanley D.A. Eliasziw M. Dewey D. Ross S. Plasma 3-Epi-25-Hydroxycholecalciferol Can Alter the Assessment of Vitamin D Status Using the Current Reference Ranges for Pregnant Women and Their Newborns J. Nutr. 2016 146 70 75 10.3945/jn.115.220095 26609169
44. Kiely M. O’Donovan S.M. Kenny L.C. Hourihane J.O. Irvine A.D. Murray D.M. Vitamin D metabolite concentrations in umbilical cord blood serum and associations with clinical characteristics in a large prospective mother-infant cohort in Ireland J. Steroid. Biochem. Mol. Biol. 2017 167 162 168 10.1016/j.jsbmb.2016.12.006 28007533
45. Hollis B.W. Pittard W.B. Evaluation of the Total Fetomaternal Vitamin-D Relationships at Term—Evidence for Racial-Differences J. Clin. Endocrinol. Metab. 1984 59 652 657 10.1210/jcem-59-4-652 6090493
46. Streym S.V. Moller U.K. Rejnmark L. Heickendorff L. Mosekilde L. Vestergaard P. Maternal and infant vitamin D status during the first 9 months of infant life-a cohort study Eur. J. Clin. Nutr. 2013 67 1022 1028 10.1038/ejcn.2013.152 24002039
47. Velaphi S.C. Izu A. Madhi S.A. Pettifor J.M. Maternal and neonatal vitamin D status at birth in black South Africans S. Afr. Med. J. 2019 109 807 813 10.7196/SAMJ.2019.v109i10.13651 31635580
48. O’Callaghan K.M. Hennessy A. Hull G.L.J. Healy K. Ritz C. Kenny L.C. Cashman K.D. Kiely M.E. Estimation of the maternal vitamin D intake that maintains circulating 25-hydroxyvitamin D in late gestation at a concentration sufficient to keep umbilical cord sera >/= 25–30 nmol/L: A dose-response, double-blind, randomized placebo-controlled trial in pregnant women at northern latitude Am. J. Clin. Nutr. 2018 108 77 91 10.1093/ajcn/nqy064 29878035 PMC6600055
49. Viljakainen H.T. Saarnio E. Hytinantti T. Miettinen M. Surcel H. Makitie O. Andersson S. Laitinen K. Lamberg-Allardt C. Maternal vitamin D status determines bone variables in the newborn J. Clin. Endocrinol. Metab. 2010 95 1749 1757 10.1210/jc.2009-1391 20139235
50. Wheeler B.J. Taylor B.J. de Lange M. Harper M.J. Jones S. Mekhail A. Houghton L.A. A Longitudinal Study of 25-Hydroxy Vitamin D and Parathyroid Hormone Status throughout Pregnancy and Exclusive Lactation in New Zealand Mothers and Their Infants at 45° S Nutrients 2018 10 86 10.3390/nu10010086 29342867 PMC5793314
51. Pietrek J. Otto-Buczkowska E. Kokot F. Karpiel R. Cekanski A. Concentration of 25-hydroxyvitamin D in serum of infants under the intermittent high-dose vitamin D3 prophylactic treatment Arch. Immunol. Ther. Exp. Warsz. 1980 28 805 814 6260055
52. Cooper C. Javaid K. Westlake S. Harvey N. Dennison E. Developmental origins of osteoporotic fracture: The role of maternal vitamin D insufficiency J. Nutr. 2005 135 2728S 2734S 10.1093/jn/135.11.2728S 16251639
53. Molgaard C. Michaelsen K.F. Vitamin D and bone health in early life Proc. Nutr. Soc. 2003 62 823 828 10.1079/PNS2003298 15018481
54. Kramer M.S. Kakuma R. Optimal duration of exclusive breastfeeding Cochrane Database Syst. Rev. 2002 1 11 10.1002/14651858.CD003517 11869667
55. Kramer M.S. Kakuma R. Optimal duration of exclusive breastfeeding Cochrane Database Syst. Rev. 2012 8 10 10.1002/14651858.CD003517.pub2 PMC7154583 22895934
56. Greer F.R. Hollis B.W. Napoli J.L. High concentrations of vitamin D2 in human milk associated with pharmacologic doses of vitamin D2 J. Pediatr. 1984 105 61 64 10.1016/S0022-3476(84)80361-3 6610738
57. Mohamed H.J.J. Rowan A. Fong B. Loy S.L. Maternal serum and breast milk vitamin D levels: Findings from the Universiti Sains Malaysia Pregnancy Cohort Study PLoS ONE 2014 9 e100705 10.1371/journal.pone.0100705 24992199 PMC4081124
58. Markestad T. Plasma concentrations of vitamin D metabolites in unsupplemented breast-fed infants Eur. J. Pediatr. 1983 141 77 80 10.1007/BF00496794 6662145
59. Madar A.A. Klepp K.I. Meyer H.E. Effect of free vitamin D2 drops on serum 25-hydroxyvitamin D in infants with immigrant origin: A cluster randomized controlled trial Eur. J. Clin. Nutr. 2009 63 478 484 10.1038/sj.ejcn.1602982 18231120
60. Brembeck P. Winkvist A. Baath M. Barebring L. Augustin H. Determinants of changes in vitamin D status postpartum in Swedish women Br. J. Nutr. 2016 115 422 430 10.1017/S0007114515004560 26586446
61. Narchi H. Kochiyil J. Zayed R. Abdulrazzak W. Agarwal M. Maternal vitamin D status throughout and after pregnancy J. Obstet. Gynaecol. 2010 30 137 142 10.3109/01443610903315652 20143971
62. Kovacs C.S. Kronenberg H.M. Maternal-fetal calcium and bone metabolism during pregnancy, puerperium, and lactation Endocr. Rev. 1997 18 832 872 10.1210/edrv.18.6.0319 9408745
63. Greer F.R. Hollis B.W. Cripps D.J. Tsang R.C. Effects of maternal ultraviolet B irradiation on vitamin D content of human milk J. Pediatr. 1984 105 431 433 10.1016/S0022-3476(84)80021-9 6088746
64. Salle B.L. Glorieux F.H. Lapillone A. Vitamin D status in breastfed term babies Acta Paediatr. 1998 87 726 727 10.1111/j.1651-2227.1998.tb01736.x 9722243
65. Aly H. Abdel-Hady H. Vitamin D and the Neonate: An Update J. Clin. Neonatol. 2015 4 1 7 10.4103/2249-4847.151155
66. Palacios C. Kostiuk L.K. Pena-Rosas J.P. Vitamin D supplementation for women during pregnancy Cochrane Database Syst. Rev. 2019 7 CD008873 10.1002/14651858.CD008873.pub4 31348529 PMC6659840
67. Ross A.C. Manson J.E. Abrams S.A. Aloia J.F. Brannon P.M. Clinton S.K. Durazo-Arvizu R.A. Gallagher J.C. Gallo R.L. Jones G. The 2011 report on dietary reference intakes for calcium and vitamin D from the Institute of Medicine: What clinicians need to know J. Clin. Endocrinol. Metab. 2011 96 53 58 10.1210/jc.2010-2704 21118827 PMC3046611
68. Yesiltepe Mutlu G. Ozsu E. Kalaca S. Yuksel A. Pehlevan Y. Cizmecioglu F. Hatun S. Evaluation of vitamin D supplementation doses during pregnancy in a population at high risk for deficiency Horm. Res. Paediatr. 2014 81 402 408 10.1159/000358833 24714660
69. Munns C.F. Shaw N. Kiely M. Specker B.L. Thacher T.D. Ozono K. Michigami T. Tiosano D. Mughal M.Z. Makitie O. Global Consensus Recommendations on Prevention and Management of Nutritional Rickets J. Clin. Endocrinol. Metab. 2016 101 394 415 10.1210/jc.2015-2175 26745253 PMC4880117
70. Hu Z. Tao S. Liu H. Pan G. Li B. Zhang Z. The Association between Polymorphisms of Vitamin D Metabolic-Related Genes and Vitamin D3 Supplementation in Type 2 Diabetic Patients J. Diabetes. Res. 2019 2019 8289741 10.1155/2019/8289741 31583252 PMC6754883
71. Mazahery H. von Hurst P.R. Factors Affecting 25-Hydroxyvitamin D Concentration in Response to Vitamin D Supplementation Nutrients 2015 7 5111 5142 10.3390/nu7075111 26121531 PMC4516990
Figure 1

Association between mother’s breastmilk concentration level of 25(OH)D3 and 3-Epi25(OH)D3 at 6 weeks postpartum (a) and 3 months postpartum (b).

Figure image at the original source — open the original paper. This file is not included in this text import.
Figure 2

Association between mother’s and infant concentration level of 25(OH)D3.

Figure image at the original source — open the original paper. This file is not included in this text import.
Table 1

Linearity, limit of quantification, and limit of detection of vitamin D metabolites measured by (a) Waters Quattro PremierTM/XE and (b) Agilent 6495B.

LinearityrLOQLOD
a. Waters Quattro PremierTM/XE nmol/L nmol/L nmol/L
25(OH)D2 7.6–242.30.99697.62.3
25(OH)D37.8–249.60.99857.82.34
3-Epi25(OH)D37.8–249.60.99867.82.3
b. Agilent 6495B
25(OH)D2 7.0–3350.99997.02.1
25(OH)D34.3–2700.99984.31.3
3-Epi25(OH)D31.7–1370.99991.70.5

Limit of quantification (LOQ), limit of detection (LOD).

Table 2

Intra-day (n) of vitamin D metabolites in plasma, breastmilk, and infant formula samples measured by (a) Waters Quattro PremierTM/XE and (b) Agilent 6495B.

Intra-Day PrecisionVitamin D Metabolites
a. Waters Quattro PremierTM/XE
Plasma (n = 6) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Medium1
 Average (nmol/L)-55.7 ± 4.8-
 RSD (%) 8
b. Agilent 6495B
Plasma (n = 10) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Low2
 Average (nmol/L)31.5 ± 4.446.1 ± 2.834.6 ± 2.7
 RSD (%)1468
Medium2
 Average (nmol/L)76.2 ± 7.5111.0 ± 3.9 49.3 ± 3.5
 RSD (%)1037
High2
 Average (nmol/L)120.3 ± 8.9177.9 ± 14.6105.6 ± 5.6
 RSD (%)785
Breastmilk (n = 10) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Low3
 Average (nmol/L)<LOQ11.7 ± 1.96.8 ± 1.0
 RSD (%) 1614
Medium3
 Average (nmol/L)47.8 ± 3.071.6 ± 2.551.7 ± 2.3
 RSD (%)644
High3
 Average (nmol/L)103.1 ± 4.4126.8 ± 9.496.7 ± 4.6
 RSD (%)475
Infant formula (n = 10) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Low4
 Average (nmol/L)<7.6 <7.8<7.8
 RSD (%)
Medium4
 Average (nmol/L)18.1 ± 3.075.3 ± 6.631.1 ± 1.7
 RSD (%)1795
High4
 Average (nmol/L)88.5 ± 8.0119.2 ± 6.1109 ± 3.3
 RSD (%)953

Relative standard deviation (RSD %).

Table 3

Inter-day precision (n) of vitamin D metabolites in plasma, breastmilk, and infant formula samples measured by (a) Waters Quattro PremierTM/XE and (b) Agilent 6495B.

Analyte
a. Waters Quattro PremierTM/XE
Plasma (n = 10) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Medium1
 Average (nmol/L)-55.5 ± 5.2-
 RSD (%) 9
b. Agilent 6495B
Plasma (n = 10) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Low2
 Average (nmol/L)30.2 ± 2.742.9 ± 3.434.5 ± 2.2
 RSD (%)986
Medium2
 Average (nmol/L)71.2 ± 4.2 102.6 ± 5.648.2 ± 3.6
 RSD (%)657
High2
 Average (nmol/L)115.3 ± 8.9162.7 ± 9.099.9 ± 5.6
 RSD (%)866
Breastmilk (n = 10) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Low3
 Average (nmol/L)<712.0 ± 25.8 ± 1.7
 RSD (%) 1730
Medium3
 Average (nmol/L)39.9 ± 2.765.0 ± 5.245.7 ± 2.6
 RSD (%)786
High3
 Average (nmol/L)97.9 ± 4.6 114.8 ± 892.0 ± 9
 RSD (%)5710
Infant formula (n = 10) 25(OH)D2 25(OH)D33-Epi25(OH)D3
Low4
 Average (nmol/L)<7<4.3<1.7
 SD
 RSD (%)
Medium4
 Average (nmol/L)21.4 ± 2.366.6 ± 2.732.2 ± 1.8
 RSD (%)1146
High4
 Average (nmol/L)93.2 ± 8.7112.1 ± 4.1107.1 ± 3.6
 RSD (%)943
Table 4

Distribution of vitamin D status at each time-point (6 weeks, 3, and 6 months) for maternal and infant samples.

WeeksMonths
Mothers 636
Breastmilk n 1 89 (%)85 (%)
 Deficient<50 nmol/L16 (18.0)26 (30.6)
 Insufficient50–74 nmol/L 35 (39.3)34 (40.0)
 Sufficient≥75 nmol/L38 (42.7)25 (29.4)
Plasma n 1 87 (%)84 (%)
 Deficient<50 nmol/L 11 (12.6)12 (14.3)
 Insufficient50–74 nmol/L 44 (50.6)40 (47.6)
 Sufficient≥75 nmol/L 32 (36.8)32 (38.1)
Infants
Plasma Total 52 (%)48 (%)
 Deficient<50 nmol/L 16 (30.8)4 (8.3)
 Insufficient50–74 nmol/L 15 (28.8)23 (47.9)
 Sufficient≥75 nmol/L 21 (40.4)21 (43.8)

1 number of samples (n).

Table 5

Concentration levels of 25(OH)D2, 25(OH)D3, and 3-Epi25(OH)D3 at 6 weeks, 3, and 6 months among mother and infant. Paired samples tests.

WeeksMonthsp Value 1
6 36
Mothers nmol/Lnmol/L
Breastmilk25(OH)D2 12.8 ± 6.712.7 ± 7.1-0.728
25(OH)D3 60.1 ± 24.850.0 ± 23.4-0.001
3-Epi25(OH)D319.7 ± 8.718.6 ± 9.0-0.327
nmol/Lnmol/L
Plasma 25(OH)D2 <7.6 2<7.6
25(OH)D3 69.6 ± 16.369.6 ± 19.00.526
3-Epi25(OH)D3 <7.8<7.8
Infants
Plasma25(OH)D2 <7.6<7.6
25(OH)D3 64.6 ± 29.183.1 ± 270.001
3-Epi25(OH)D3 7.8 ± 4.8<7.6

1 Paired samples test. 2 The number of breastmilk samples below limit of quantification (LOQ) were 31 and 32 for 25(OH)D2, 0 and 2 for 25(OH)D3, and 1 and 3 for 3-Epi25(OH)D3 at 6 weeks and 3 months, respectively. The number of infant plasma samples below LOQ were 19 and 20 for 3-Epi25(OH)D3 at 3 and 6 months, respectively.

Publication and source details

Original title: Validation and Determination of 25(OH) Vitamin D and 3-Epi25(OH)D3 in Breastmilk and Maternal- and Infant Plasma during Breastfeeding

Jennifer Gjerde; Marian Kjellevold; Lisbeth Dahl; Torill Berg; Annbjørg Bøkevoll; Maria Wik Markhus

Nutrients · 2020

* Correspondence: Jennifer.Gjerde@hi.no; Tel.: +4793652137© 2020 by the authors.2020https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-11T16:50:17.551509+00:00

DOI: 10.3390/nu12082271 · PMC7469027