Vitamin D3 for Life. Live Enlightened.

Research libraryVitamin D3 For Life
Study design and methods

Primary relevance to vitamin D Vitamin D is a stated subject of this paper.

Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.

Why this paper is included

Supporting source evidence:

Compared to measured vitamin D levels >75 nmol/L, levels <25 nmol/L at sperm ejaculation were associated with lower total sperm count (: 15% [95% confidence interval:: 33%; 8%]), and a higher proportion of non‐progressive and immotile spermatozoa (11% [95% confidence interval: 0%; 24%]).

Source: Abstract. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Study design awaiting verification.

Study design awaiting verification

The available source does not establish a sufficiently clear study design.

Meta-analysis unclear · Blinding unclear / not reported · Human research reported

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

Prior to semen sample collection at their home (18%) or at the clinic (82%), the participants were encouraged to stay abstinent for at least 2 days.

Source: Methods.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Abstracts

Vitamin D levels and biomarkers of male fecundity: A study from the Danish National Birth Cohort

Study design awaiting verification · Andrology · 2025

Original publication title

Vitamin D levels and biomarkers of male fecundity: A study from the Danish National Birth Cohort

Anne Gaml‐Sørensen; Nis Brix; Sandra Søgaard Tøttenborg; Christian Lindh; Karin Sørig Hougaard; Siri Eldevik Håberg; Gunnar Toft; Jens Peter Ellekilde Bonde; Cecilia Høst Ramlau‐Hansen

© 2025 The Author(s). Andrology published by Wiley Periodicals LLC on behalf of American Society of Andrology and European Academy of Andrology.

Original publication · Publisher record · CC BY 4.0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

Authors’ conclusion

Lower vitamin D levels before and during spermatogenesis and at sperm ejaculation were associated with lower total sperm count and sperm motility and an altered reproductive hormone profile.

An extract from the source publication. Read it in context.

At a glance

Abstract: What objectives does the paper state?

To investigate the association between plasma vitamin D levels at sperm ejaculation and during spermatogenesis and biomarkers of male fecundity in young men.

Source: Objectives

Abstract: What methods does the paper describe?

From the Fetal Programming of Semen Quality cohort, Denmark, 2017 to 2019, 1047 young men provided a semen and a blood sample, and self‐measured their testes volume at a clinical visit. Plasma levels of vitamin D (25(OH)D3) and reproductive hormones were measured in the blood sample. Relative percentage differences in semen characteristics, testes volume and reproductive hormone levels were analysed according to measured vitamin D levels (categorised, continuous and as restricted cubic splines) at sperm ejaculation. Additionally, we used the seasonal variation in endogenous vitamin D synthesis to estimate individual vitamin D levels 3 months prior to sperm ejaculation (at initiation of spermatogenesis) in addition to 2 and 1 month before.

This was analysed following the same strategy.

Source: Materials and methods

Abstract: Discussion

By using the seasonal variation in endogen vitamin D synthesis, we were able to estimate individual vitamin D levels during spermatogenesis.

Source: Discussion

Abstract: Results

Compared to measured vitamin D levels >75 nmol/L, levels <25 nmol/L at sperm ejaculation were associated with lower total sperm count (: 15% [95% confidence interval:: 33%; 8%]), and a higher proportion of non‐progressive and immotile spermatozoa (11% [95% confidence interval: 0%; 24%]). Lower measured vitamin D levels were also associated with higher oestradiol, lower sex hormone‐binding globulin and lower follicle‐stimulating hormone, in dose‐dependent manners. Vitamin D levels estimated before and during spermatogenesis yielded similar associations as vitamin D levels measured at sperm ejaculation.

Source: Results

Abstract: Conclusion

Lower vitamin D levels before and during spermatogenesis and at sperm ejaculation were associated with lower total sperm count and sperm motility and an altered reproductive hormone profile.

Source: Conclusion
Authors’ abstract

Abstract

Background

Vitamin D is metabolised throughout the male reproductive system, suggesting a direct regulatory role of vitamin D in male reproduction.

Objectives

To investigate the association between plasma vitamin D levels at sperm ejaculation and during spermatogenesis and biomarkers of male fecundity in young men.

Materials and methods

From the Fetal Programming of Semen Quality cohort, Denmark, 2017 to 2019, 1047 young men provided a semen and a blood sample, and self‐measured their testes volume at a clinical visit. Plasma levels of vitamin D (25(OH)D3) and reproductive hormones were measured in the blood sample. Relative percentage differences in semen characteristics, testes volume and reproductive hormone levels were analysed according to measured vitamin D levels (categorised, continuous and as restricted cubic splines) at sperm ejaculation. Additionally, we used the seasonal variation in endogenous vitamin D synthesis to estimate individual vitamin D levels 3 months prior to sperm ejaculation (at initiation of spermatogenesis) in addition to 2 and 1 month before.

This was analysed following the same strategy.

Results

Compared to measured vitamin D levels >75 nmol/L, levels <25 nmol/L at sperm ejaculation were associated with lower total sperm count (: 15% [95% confidence interval:: 33%; 8%]), and a higher proportion of non‐progressive and immotile spermatozoa (11% [95% confidence interval: 0%; 24%]). Lower measured vitamin D levels were also associated with higher oestradiol, lower sex hormone‐binding globulin and lower follicle‐stimulating hormone, in dose‐dependent manners. Vitamin D levels estimated before and during spermatogenesis yielded similar associations as vitamin D levels measured at sperm ejaculation.

Discussion

By using the seasonal variation in endogen vitamin D synthesis, we were able to estimate individual vitamin D levels during spermatogenesis.

Conclusion

Lower vitamin D levels before and during spermatogenesis and at sperm ejaculation were associated with lower total sperm count and sperm motility and an altered reproductive hormone profile.

Publication and source details

Original title: Vitamin D levels and biomarkers of male fecundity: A study from the Danish National Birth Cohort

Anne Gaml‐Sørensen; Nis Brix; Sandra Søgaard Tøttenborg; Christian Lindh; Karin Sørig Hougaard; Siri Eldevik Håberg; Gunnar Toft; Jens Peter Ellekilde Bonde; Cecilia Høst Ramlau‐Hansen

Andrology · 2025

* Correspondence
Anne Gaml‐Sørensen, Department of Public Health, Aarhus University, Aarhus 8000, Denmark.
Email: ags@ph.au.dk
© 2025 The Author(s). Andrology published by Wiley Periodicals LLC on behalf of American Society of Andrology and European Academy of Andrology.https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. Lundbeck Foundation10.13039/501100003554 R170‐2014‐855 European Union, Intereg V ÖKS 20200407 Capital Region of Denmark, Region Skåne Medical Faculty at Lund University, Sweden Axel Muusfeldt's Foundation 2016‐491 A.P. Møller Foundation 16‐37 Health Foundation10.13039/501100000724 Dagmar Marshall's Fond European Union (ERC, BIOSFER) 101071773

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-11T00:47:39.357149+00:00

DOI: 10.1111/andr.70061 · PMC12917574