Vitamin D3 for Life

Live Enlightened

Research libraryVitamin D3 For Life
Study design and methods

Primary relevance to vitamin D Vitamin D is a stated subject of this paper.

Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.

Why this paper is included

Supporting source evidence:

A novel caged Cookson‐type reagent toward a practical vitamin D derivatization method for mass spectrometric analyses

Source: Article title. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Study design awaiting verification.

Study design awaiting verification

The available source does not establish a sufficiently clear study design.

Meta-analysis unclear · Blinding unclear / not reported · Research setting awaiting verification

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Abstracts

A novel caged Cookson‐type reagent toward a practical vitamin D derivatization method for mass spectrometric analyses

Study design awaiting verification · Rapid Communications in Mass Spectrometry · 2020

Original publication title

A novel caged Cookson‐type reagent toward a practical vitamin D derivatization method for mass spectrometric analyses

Masahiko Seki; Makoto Sato; Masaki Takiwaki; Koji Takahashi; Yoshikuni Kikutani; Mamoru Satoh; Fumio Nomura; Yutaka Kuroda; Seketsu Fukuzawa

© 2019 The Authors. Rapid Communications in Mass Spectrometry published by John Wiley & Sons Ltd

Original publication · Publisher record · CC BY 4.0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

Authors’ conclusion

DAP‐PA was stable enough for mid‐ to long‐term storage in solution. This advantage shall contribute to the detection and quantification of VD in clinical laboratories, and as such to the broader use of clinical mass spectrometry.

An extract from the source publication. Read it in context.

At a glance

Abstract: What methods does the paper describe?

Caged 4‐(4′‐dimethylaminophenyl)‐1,2,4‐triazoline‐3,5‐dione (DAPTAD) analogues were prepared from 4‐(4′‐dimethylaminophenyl)‐1,2,4‐triazolidine‐3,5‐dione. Their stability and reactivity were examined. The optimized caged DAPTAD (14‐(4‐(dimethylamino)phenyl)‐9‐phenyl‐9,10‐dihydro‐9,10‐[1,2]epitriazoloanthracene‐13,15‐dione, DAP‐PA) was used for LC/MS/MS analyses of VD metabolites.

Source: Methods

Abstract: Rationale

25‐Hydroxylated vitamin D is the best marker for vitamin D (VD). Due to its low ionization efficiency, a Cookson‐type reagent, 1,2,4‐triazoline‐3,5‐dione (TAD), is used to improve the detection/quantification of VD metabolites by liquid chromatography/tandem mass spectrometry (LC/MS/MS). However, the high reactivity of TAD makes its solution stability low and inconvenient for practical use. We here describe the development of a novel caged Cookson‐type reagent, and we assess its performances in the quantitative and differential detection of four VD metabolites in serum using LC/MS/MS.

Source: Rationale

Abstract: Results

The solution stability of DAP‐PA in ethyl acetate dramatically improved compared with that of the non‐caged one. We measured the thermal retro‐Diels‐Alder reaction enabling the release of DAPTAD and found that the derivatization reaction was temperature‐dependent. We also determined the detection limit and the lower limit of quantifications for four VD metabolites with DAPTAD derivatization.

Source: Results

Abstract: Conclusions

DAP‐PA was stable enough for mid‐ to long‐term storage in solution. This advantage shall contribute to the detection and quantification of VD in clinical laboratories, and as such to the broader use of clinical mass spectrometry.

Source: Conclusions
Authors’ abstract

Rationale

25‐Hydroxylated vitamin D is the best marker for vitamin D (VD). Due to its low ionization efficiency, a Cookson‐type reagent, 1,2,4‐triazoline‐3,5‐dione (TAD), is used to improve the detection/quantification of VD metabolites by liquid chromatography/tandem mass spectrometry (LC/MS/MS). However, the high reactivity of TAD makes its solution stability low and inconvenient for practical use. We here describe the development of a novel caged Cookson‐type reagent, and we assess its performances in the quantitative and differential detection of four VD metabolites in serum using LC/MS/MS.

Methods

Caged 4‐(4′‐dimethylaminophenyl)‐1,2,4‐triazoline‐3,5‐dione (DAPTAD) analogues were prepared from 4‐(4′‐dimethylaminophenyl)‐1,2,4‐triazolidine‐3,5‐dione. Their stability and reactivity were examined. The optimized caged DAPTAD (14‐(4‐(dimethylamino)phenyl)‐9‐phenyl‐9,10‐dihydro‐9,10‐[1,2]epitriazoloanthracene‐13,15‐dione, DAP‐PA) was used for LC/MS/MS analyses of VD metabolites.

Results

The solution stability of DAP‐PA in ethyl acetate dramatically improved compared with that of the non‐caged one. We measured the thermal retro‐Diels‐Alder reaction enabling the release of DAPTAD and found that the derivatization reaction was temperature‐dependent. We also determined the detection limit and the lower limit of quantifications for four VD metabolites with DAPTAD derivatization.

Conclusions

DAP‐PA was stable enough for mid‐ to long‐term storage in solution. This advantage shall contribute to the detection and quantification of VD in clinical laboratories, and as such to the broader use of clinical mass spectrometry.

Publication and source details

Original title: A novel caged Cookson‐type reagent toward a practical vitamin D derivatization method for mass spectrometric analyses

Masahiko Seki; Makoto Sato; Masaki Takiwaki; Koji Takahashi; Yoshikuni Kikutani; Mamoru Satoh; Fumio Nomura; Yutaka Kuroda; Seketsu Fukuzawa

Rapid Communications in Mass Spectrometry · 2020

* Correspondence
S. Fukuzawa, Department of Biotechnology and Life Science, Faculty of Technology, Tokyo University of Agriculture and Technology, 2‐24‐16 Naka‐cho, Koganei. Tokyo 184‐8588, Japan and Open Innovation Promotion Department, Management Strategy Planning Division, JEOL Ltd., 3‐1‐2 Musashino, Akishima, Tokyo 196‐8558, Japan.
Email: s-fukuzawa@m2.tuat.ac.jp; sfukuzaw@jeol.co.jp
© 2019 The Authors. Rapid Communications in Mass Spectrometry published by John Wiley & Sons Ltdhttps://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-11T17:40:24.525047+00:00

DOI: 10.1002/rcm.8648 · PMC7064983