Vitamin D3 for Life

Live Enlightened

Research libraryVitamin D3 For Life
Study design and methods

Primary relevance to vitamin D Vitamin D is a stated subject of this paper.

Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.

Why this paper is included

Supporting source evidence:

The large gender difference was strongly attenuated after standardization of the assays with only 15.7% of women and 14.3% of men with vitamin D deficiency.

Source: Abstract. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Cohort study.

Cohort study

Examines exposures and outcomes over time within a defined group.

Meta-analysis unclear · Blinding unclear / not reported · Human research reported

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

Standardization of Misleading Immunoassay Based 25-Hydroxyvitamin D Levels with Liquid Chromatography Tandem-Mass Spectrometry in a Large Cohort Study

Source: Article title.

The Diasorin-Liaison method utilized for women was unavailable at this date because it had been replaced by the manufacturer by another method in 2007 .

Source: Methods.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Abstracts

Standardization of Misleading Immunoassay Based 25-Hydroxyvitamin D Levels with Liquid Chromatography Tandem-Mass Spectrometry in a Large Cohort Study

Cohort study · PLoS ONE · 2012

Original publication title

Standardization of Misleading Immunoassay Based 25-Hydroxyvitamin D Levels with Liquid Chromatography Tandem-Mass Spectrometry in a Large Cohort Study

Ben Schöttker; Eugène H. J. M. Jansen; Ulrike Haug; Lutz Schomburg; Josef Köhrle; Hermann Brenner

© 2012 Schöttker et al

Original publication · Publisher record · CC BY 4.0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

Authors’ conclusion

The standardization with LC-MS/MS revealed that much of the observed gender difference was only assay-driven and the extremely high proportion of 48.3% vitamin D deficient women proved to be an exaggeration of the old version of the Diasorin-Liaison immunoassay. Standardization of 25(OH)D immunoassay results by LC-MS/MS is recommended to improve their accuracy and comparability, provided the LC-MS/MS method itself is adequately validated and standardized.

An extract from the source publication. Read it in context.

At a glance

Abstract: What background does the paper provide?

The interest in vitamin D measurement has strongly increased in recent years. The best indicator for circulating vitamin D levels is 25-hydroxy-vitamin D (25(OH)D) which is often measured by different immunoassays. We demonstrate problems in comparability of measures by different immunoassays and the need for standardization in the context of a large population-based cohort study.

Source: Background

Abstract: What methods does the paper describe?

25(OH)D was measured with the immunoassays Diasorin Liaison in 2006 in 5,386 women and in the context of another project with IDS-iSYS in 4,199 men in 2009 to 2010 (when the Diasorin Liaison was no longer available in the version utilized in 2006). Standardization was performed by re-measuring of 25(OH)D levels in 97 men and 97 women with liquid chromatography tandem-mass spectrometry (LC-MS/MS) to obtain linear regression conversion equations.

Source: Methods

Abstract: Results

Applying a 30 nmol/L cut-off value for vitamin D deficiency would have resulted in 48.3% of women and 12.1% of men with vitamin D deficiency ahead of standardization. The large gender difference was strongly attenuated after standardization of the assays with only 15.7% of women and 14.3% of men with vitamin D deficiency. Standardization on average increased the 25(OH)D levels by 10.3 nmol/L in women and decreased 25(OH)D levels by 2.9 nmol/L in men.

Source: Results

Abstract: Conclusion

The standardization with LC-MS/MS revealed that much of the observed gender difference was only assay-driven and the extremely high proportion of 48.3% vitamin D deficient women proved to be an exaggeration of the old version of the Diasorin-Liaison immunoassay. Standardization of 25(OH)D immunoassay results by LC-MS/MS is recommended to improve their accuracy and comparability, provided the LC-MS/MS method itself is adequately validated and standardized.

Source: Conclusion
Authors’ abstract

Background

The interest in vitamin D measurement has strongly increased in recent years. The best indicator for circulating vitamin D levels is 25-hydroxy-vitamin D (25(OH)D) which is often measured by different immunoassays. We demonstrate problems in comparability of measures by different immunoassays and the need for standardization in the context of a large population-based cohort study.

Methods

25(OH)D was measured with the immunoassays Diasorin Liaison in 2006 in 5,386 women and in the context of another project with IDS-iSYS in 4,199 men in 2009 to 2010 (when the Diasorin Liaison was no longer available in the version utilized in 2006). Standardization was performed by re-measuring of 25(OH)D levels in 97 men and 97 women with liquid chromatography tandem-mass spectrometry (LC-MS/MS) to obtain linear regression conversion equations.

Results

Applying a 30 nmol/L cut-off value for vitamin D deficiency would have resulted in 48.3% of women and 12.1% of men with vitamin D deficiency ahead of standardization. The large gender difference was strongly attenuated after standardization of the assays with only 15.7% of women and 14.3% of men with vitamin D deficiency. Standardization on average increased the 25(OH)D levels by 10.3 nmol/L in women and decreased 25(OH)D levels by 2.9 nmol/L in men.

Conclusion

The standardization with LC-MS/MS revealed that much of the observed gender difference was only assay-driven and the extremely high proportion of 48.3% vitamin D deficient women proved to be an exaggeration of the old version of the Diasorin-Liaison immunoassay. Standardization of 25(OH)D immunoassay results by LC-MS/MS is recommended to improve their accuracy and comparability, provided the LC-MS/MS method itself is adequately validated and standardized.

Publication and source details

Original title: Standardization of Misleading Immunoassay Based 25-Hydroxyvitamin D Levels with Liquid Chromatography Tandem-Mass Spectrometry in a Large Cohort Study

Ben Schöttker; Eugène H. J. M. Jansen; Ulrike Haug; Lutz Schomburg; Josef Köhrle; Hermann Brenner

PLoS ONE · 2012

* E-mail: b.schoettker@dkfz.de

Competing Interests: The authors have declared that no competing interests exist.

Conceived and designed the experiments: BS EJ UH HB LS JK. Performed the experiments: EJ LS JK. Analyzed the data: BS. Contributed reagents/materials/analysis tools: EJ LS JK. Wrote the paper: BS. Commented on the manuscript draft: EJ UH HB LS JK.

© 2012 Schöttker et al2012Schöttker et alhttps://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are properly credited.This study was conducted in the context of the CHANCES project funded in the FP7 framework programme of DG-RESEARCH in the European Commission and the German Cancer Aid project number 108250 and 108426. The CHANCES project is coordinated by the Hellenic Health Foundation, Greece. The ESTHER study was funded by the Baden-Württemberg State Ministry of Science, Research and Arts (Stuttgart, Germany). The funders had no role in study design, data collection and analysis, decision to publish, or preparation of the manuscript.

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-12T13:56:37.805682+00:00

DOI: 10.1371/journal.pone.0048774 · PMC3486791