Primary relevance to vitamin D Vitamin D is a stated subject of this paper.
Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.
Why this paper is included
Supporting source evidence:
The comparison between levels in Tables 3 and 4 reveals that where epimers and isobars are not accounted for, the measurements of Vitamin D levels are inflated to appear as normal.
Source: Results. View original paper
Relevance classification does not establish study quality, causation or editorial approval.
Study design Study design awaiting verification.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.
Meta-analysis unclear · Blinding unclear / not reported · Research setting awaiting verification
How this paper was classified
Automatic source-based classification; awaiting editorial verification. This is not a quality score.
What the study types mean
- Systematic review
- Uses explicit methods to identify, assess and summarise research on a defined question.
- Scoping review
- Maps the extent and characteristics of research on a topic.
- Narrative review
- Discusses existing research; systematic-review methods have not been established by this classification.
- Review / evidence synthesis
- Reviews existing research; the exact review methods need further assessment.
- Randomised controlled trial
- Assigns participants or groups to comparison interventions by chance.
- Non-randomised intervention study
- Examines an intervention without random allocation.
- Cohort study
- Examines exposures and outcomes over time within a defined group.
- Case-control study
- Compares people with an outcome against people without it, examining exposures.
- Cross-sectional study
- Examines a population at a particular point in time.
- Observational study
- Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
- Case report
- Describes an individual case.
- Case series
- Describes a group of individual cases.
- Secondary analysis
- Analyses existing study data; this paper is not automatically another independent trial.
- Laboratory study
- Investigates biological processes in a laboratory setting.
- Qualitative study
- Examines experiences or meanings using qualitative methods.
- Genetic instrumental-variable study
- Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
- Study protocol
- Describes planned methods and is not evidence that the planned study has reported results.
- Multiple reported designs
- More than one design is explicitly reported; examine the supporting methods.
- Study design awaiting verification
- The available source does not establish a sufficiently clear study design.
Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.
Abstracts
Misleading measures in Vitamin D analysis: A novel LC-MS/MS assay to account for epimers and isobars
Study design awaiting verification · Nutrition Journal · 2011
Original publication title
Misleading measures in Vitamin D analysis: A novel LC-MS/MS assay to account for epimers and isobars
Copyright ©2011 Shah et al; licensee BioMed Central Ltd.
Original publication · Publisher record · CC BY 2.0
Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.
At a glance
Abstract: What background does the paper provide?
Recently, the accuracies of many commercially available immunoassays for Vitamin D have been questioned. Liquid chromatography tandem mass spectrometry (LC: MS/MS) has been shown to facilitate accurate separation and quantification of the major circulating metabolite 25-hydroxyvitamin-D3 (25OHD3) and 25-hydroxyvitamin-D2 (25OHD2) collectively termed as 25OHD. However, among other interferents, this method may be compromised by overlapping peaks and identical masses of epimers and isobars, resulting in inaccuracies in circulating 25OHD measurements. The aim of this study was to develop a novel LC-MS/MS method that can accurately identify and quantitate 25OHD3 and 25OHD2 through chromatographic separation of 25OHD from its epimers and isobars.
Source: BackgroundAbstract: What methods does the paper describe?
A positive ion electrospray ionisation (ESI) LC-MS/MS method was used in the Multiple Reaction Monitoring (MRM) mode for quantification. It involved i) liquid-liquid extraction, ii) tandem columns (a high resolution ZORBAX C18 coupled to an ULTRON chiral, with guard column and inlet filter), iii) Stanozolol-D3 as internal standard, and iv) identification via ESI and monitoring of three fragmentation transitions. To demonstrate the practical usefulness of our method, blood samples were collected from 5 healthy male Caucasian volunteers; age range 22 to 37 years and 25OHD2, 25OHD3 along with co-eluting epimers and analogues were quantified.
Source: MethodsAbstract: Results
The new method allowed chromatographic separation and quantification of 25OHD2, 25OHD3, along with 25OHD3 epimer 3-epi-25OHD3 and isobars 1-α-hydroxyvitamin-D3 (1αOHD3), and 7-α-hydroxy-4-cholesten-3-one (7αC4). The new assay was capable of detecting 0.25 ng/mL of all analytes in serum.
Source: ResultsAbstract: Conclusions
To our knowledge, this is the first specific, reliable, reproducible and robust LC-MS/MS method developed for the accurate detection of 25OHD (Vitamin D). The method is capable of detecting low levels of 25OHD3 and 25OHD2 together with chromatographic separation from the co-eluting epimers and isobars and circumvents other instrumental/analytical interferences. This analytical method does not require time-consuming derivatisation and complex extraction techniques and could prove very useful in clinical studies.
Source: ConclusionsAuthors’ abstract
Background
Recently, the accuracies of many commercially available immunoassays for Vitamin D have been questioned. Liquid chromatography tandem mass spectrometry (LC: MS/MS) has been shown to facilitate accurate separation and quantification of the major circulating metabolite 25-hydroxyvitamin-D3 (25OHD3) and 25-hydroxyvitamin-D2 (25OHD2) collectively termed as 25OHD. However, among other interferents, this method may be compromised by overlapping peaks and identical masses of epimers and isobars, resulting in inaccuracies in circulating 25OHD measurements. The aim of this study was to develop a novel LC-MS/MS method that can accurately identify and quantitate 25OHD3 and 25OHD2 through chromatographic separation of 25OHD from its epimers and isobars.
Methods
A positive ion electrospray ionisation (ESI) LC-MS/MS method was used in the Multiple Reaction Monitoring (MRM) mode for quantification. It involved i) liquid-liquid extraction, ii) tandem columns (a high resolution ZORBAX C18 coupled to an ULTRON chiral, with guard column and inlet filter), iii) Stanozolol-D3 as internal standard, and iv) identification via ESI and monitoring of three fragmentation transitions. To demonstrate the practical usefulness of our method, blood samples were collected from 5 healthy male Caucasian volunteers; age range 22 to 37 years and 25OHD2, 25OHD3 along with co-eluting epimers and analogues were quantified.
Results
The new method allowed chromatographic separation and quantification of 25OHD2, 25OHD3, along with 25OHD3 epimer 3-epi-25OHD3 and isobars 1-α-hydroxyvitamin-D3 (1αOHD3), and 7-α-hydroxy-4-cholesten-3-one (7αC4). The new assay was capable of detecting 0.25 ng/mL of all analytes in serum.
Conclusions
To our knowledge, this is the first specific, reliable, reproducible and robust LC-MS/MS method developed for the accurate detection of 25OHD (Vitamin D). The method is capable of detecting low levels of 25OHD3 and 25OHD2 together with chromatographic separation from the co-eluting epimers and isobars and circumvents other instrumental/analytical interferences. This analytical method does not require time-consuming derivatisation and complex extraction techniques and could prove very useful in clinical studies.
Publication and source details
Original title: Misleading measures in Vitamin D analysis: A novel LC-MS/MS assay to account for epimers and isobars
Iltaf Shah; Ricky James; James Barker; Andrea Petroczi; Declan P Naughton
Nutrition Journal · 2011
Copyright ©2011 Shah et al; licensee BioMed Central Ltd.2011Shah et al; licensee BioMed Central Ltd.https://creativecommons.org/licenses/by/2.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.Repository JATS snapshot; version as supplied
Source retrieved: 2026-11-12T14:21:09.668198+00:00
DOI: 10.1186/1475-2891-10-46 · PMC3114718