Vitamin D3 for Life. Live Enlightened.

Research libraryVitamin D3 For Life
Study design and methods

Primary relevance to vitamin D Vitamin D is a stated subject of this paper.

Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.

Why this paper is included

Supporting source evidence:

VACUETTE® tubes containing additives significantly affect the accuracy of 25OHD results obtained using the Siemens ADVIA Centaur XP system.

Source: Abstract. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Study design awaiting verification.

Study design awaiting verification

The available source does not establish a sufficiently clear study design.

Meta-analysis unclear · Blinding unclear / not reported · Human research reported

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

Twenty healthy volunteers were recruited, and fasting blood samples were collected by venipuncture into four types of venous blood collection tubes: 5-mL BD Vacutainer® SST tubes (REF: 366566, lot #4113190; BD, Franklin Lakes, NJ, USA); IMPROVEVACUTER® tubes with serum clot activator and gel (REF: U222538, lot #141014; IMPROVEMEDICAL, Guangzhou, China); VACUETTE® 4-mL no-additive tubes (REF: 454001, lot #A1405144; Greiner Bio-one, Kremsmunster, Austria); and VACUETTE® tubes with serum clot activator and gel (REF: 454067, lot #A130202D; Greiner Bio-one).

Source: Methods.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Abstracts

Blood Collection Tubes and Storage Temperature Should Be Evaluated when Using the Siemens ADVIA Centaur XP for Measuring 25-Hydroxyvitamin D

Study design awaiting verification · PLoS ONE · 2016

Original publication title

Blood Collection Tubes and Storage Temperature Should Be Evaluated when Using the Siemens ADVIA Centaur XP for Measuring 25-Hydroxyvitamin D

Songlin Yu; Weiyan Zhou; Xinqi Cheng; Huiling Fang; Ruiping Zhang; Qian Cheng; Jianhua Han; Wei Su; Liangyu Xia; Ling Qiu

© 2016 Yu et al

Original publication · Publisher record · CC BY 4.0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

At a glance

What does the authors’ abstract report?

A significant bias was found when using the Siemens ADVIA Centaur XP system for measurement of 25-hydroxyvitamin D (25OHD) with VACUETTE® tubes with Serum Clot Activator and Gel. Here, we examined whether other commonly used tubes or temperatures affected 25OHD results obtained with the Siemens ADVIA Centaur XP system. Serum was collected into five types of vacuum blood collection tubes from three manufacturers, and 25OHD was analyzed using the Siemens ADVIA Centaur XP system and liquid chromatography tandem mass spectrometry (LC-MS/MS) immediately or after storage at 4°C or -80°C for 48 h.

Significantly higher 25OHD values were found when using the Siemens ADVIA Centaur XP system with VACUETTE® tubes with serum clot activator and gel and VACUETTE® tubes with clot activator but no gel compared with VACUETTE® tubes with no additives. The 25OHD values in all of these tubes were not significantly different from those obtained by LC-MS/MS. Moreover, after storage at -80°C for 48 h, the values obtained in IMPROVEVACUTER® tubes with serum clot activator and gel significantly increased, with a mean bias of 74.6% compared with the values before storage, on analysis with the Siemens ADVIA Centaur XP system.

VACUETTE® tubes containing additives significantly affect the accuracy of 25OHD results obtained using the Siemens ADVIA Centaur XP system. Additionally, the composition of serum collected in IMPROVEVACUTER® tubes was affected by freezing, resulting in different measurements when using the Siemens 25OHD assay platform.

Authors’ abstract

A significant bias was found when using the Siemens ADVIA Centaur XP system for measurement of 25-hydroxyvitamin D (25OHD) with VACUETTE® tubes with Serum Clot Activator and Gel. Here, we examined whether other commonly used tubes or temperatures affected 25OHD results obtained with the Siemens ADVIA Centaur XP system. Serum was collected into five types of vacuum blood collection tubes from three manufacturers, and 25OHD was analyzed using the Siemens ADVIA Centaur XP system and liquid chromatography tandem mass spectrometry (LC-MS/MS) immediately or after storage at 4°C or -80°C for 48 h.

Significantly higher 25OHD values were found when using the Siemens ADVIA Centaur XP system with VACUETTE® tubes with serum clot activator and gel and VACUETTE® tubes with clot activator but no gel compared with VACUETTE® tubes with no additives. The 25OHD values in all of these tubes were not significantly different from those obtained by LC-MS/MS. Moreover, after storage at -80°C for 48 h, the values obtained in IMPROVEVACUTER® tubes with serum clot activator and gel significantly increased, with a mean bias of 74.6% compared with the values before storage, on analysis with the Siemens ADVIA Centaur XP system.

VACUETTE® tubes containing additives significantly affect the accuracy of 25OHD results obtained using the Siemens ADVIA Centaur XP system. Additionally, the composition of serum collected in IMPROVEVACUTER® tubes was affected by freezing, resulting in different measurements when using the Siemens 25OHD assay platform.

Publication and source details

Original title: Blood Collection Tubes and Storage Temperature Should Be Evaluated when Using the Siemens ADVIA Centaur XP for Measuring 25-Hydroxyvitamin D

Songlin Yu; Weiyan Zhou; Xinqi Cheng; Huiling Fang; Ruiping Zhang; Qian Cheng; Jianhua Han; Wei Su; Liangyu Xia; Ling Qiu

PLoS ONE · 2016

Competing Interests: The authors have declared that no competing interests exist.

  • Conceptualization: SY LQ.

  • Data curation: WS.

  • Formal analysis: SY XC HF RZ.

  • Investigation: LX.

  • Methodology: WZ.

  • Project administration: LQ.

  • Software: JH XC.

  • Supervision: LQ.

  • Validation: QC.

  • Writing: original draft: SY.

  • Writing: review & editing: LQ SY.

* E-mail: lingqiubj@163.com
© 2016 Yu et al2016Yu et alhttps://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.China National Clinical Key Subject Programhttp://dx.doi.org/10.13039/501100001809National Natural Science Foundation of China81201337Zhou Weiyan the National High Technology Research and Development Program863 Program, 2014AA022304Qiu Ling This work was funded by the China National Clinical Key Subject Program and by research grants from the National Natural Science Foundation of China (81201337) (http://www.nsfc.gov.cn/), and the National High Technology Research and Development Program of China (863 Program, 2014AA022304) (http://program.most.gov.cn/ [link unavailable]). The funding bodies were not involved in conducting or analyzing this work, and were not involved in the decision to publish.

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-12T08:51:00.738395+00:00

DOI: 10.1371/journal.pone.0166327 · PMC5104342