Primary relevance to vitamin D Vitamin D is a stated subject of this paper.
Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.
Why this paper is included
Supporting source evidence:
The objective of this study is to measure tear vitamin D levels and investigate the correlation between serum and tear vitamin D levels.
Source: Abstract. View original paper
Relevance classification does not establish study quality, causation or editorial approval.
Study design Cohort study.
Cohort study
Examines exposures and outcomes over time within a defined group.
Meta-analysis unclear · Blinding unclear / not reported · Human research reported
How this paper was classified
Automatic source-based classification; awaiting editorial verification. This is not a quality score.
A total of 48 healthy volunteers without any systemic and ocular disease were recruited for this observational cohort study.
Source: Abstract.
A total of 48 healthy volunteers were selected (after obtaining informed written consent) for the study after thorough clinical investigation at Narayana Nethralaya Eye Hospital, Bangalore, India to rule out any ongoing or recent ocular and/or systemic co-morbidity.
Source: Methods.
What the study types mean
- Systematic review
- Uses explicit methods to identify, assess and summarise research on a defined question.
- Scoping review
- Maps the extent and characteristics of research on a topic.
- Narrative review
- Discusses existing research; systematic-review methods have not been established by this classification.
- Review / evidence synthesis
- Reviews existing research; the exact review methods need further assessment.
- Randomised controlled trial
- Assigns participants or groups to comparison interventions by chance.
- Non-randomised intervention study
- Examines an intervention without random allocation.
- Cohort study
- Examines exposures and outcomes over time within a defined group.
- Case-control study
- Compares people with an outcome against people without it, examining exposures.
- Cross-sectional study
- Examines a population at a particular point in time.
- Observational study
- Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
- Case report
- Describes an individual case.
- Case series
- Describes a group of individual cases.
- Secondary analysis
- Analyses existing study data; this paper is not automatically another independent trial.
- Laboratory study
- Investigates biological processes in a laboratory setting.
- Qualitative study
- Examines experiences or meanings using qualitative methods.
- Genetic instrumental-variable study
- Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
- Study protocol
- Describes planned methods and is not evidence that the planned study has reported results.
- Multiple reported designs
- More than one design is explicitly reported; examine the supporting methods.
- Study design awaiting verification
- The available source does not establish a sufficiently clear study design.
Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.
Abstracts
Correlation between tear fluid and serum vitamin D levels
Cohort study · Eye and Vision · 2016
Original publication title
Correlation between tear fluid and serum vitamin D levels
© The Author(s). 2016
Original publication · Publisher record · CC BY 4.0 · CC0
Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.
At a glance
Abstract: What background does the paper provide?
Vitamin D deficiency is associated with a range of systemic diseases including ocular disorders. The objective of this study is to measure tear vitamin D levels and investigate the correlation between serum and tear vitamin D levels.
Source: BackgroundAbstract: What methods does the paper describe?
A total of 48 healthy volunteers without any systemic and ocular disease were recruited for this observational cohort study. Serum was collected using clot activator coated Vacutainer® Plus tubes. Tear fluid was collected using Schirmer’s strips. Serum and tear total 25-hydroxyvitamin D levels were measured by competitive chemiluminescent ELISA and the correlation between the levels were studied.
Source: MethodsAbstract: Results
The measured serum 25-hydroxyvitamin D level ranged between 3.3 and 27.5 ng/ml (Mean ± SEM, 9.4 ± 0.7 ng/ml; Median 8.4 ng/ml). Significantly (p < 0.0001) higher level of 25-hydroxyvitamin D was detected in the tears (Mean ± SEM, 17.0 ± 1.6 ng/ml; Range 3.2 to 45.8 ng/ml; Median, 16.3 ng/ml) compared to serum. An average of ~2 fold (Mean ± SEM, 1.9 ± 0.2; Range 0.4 to 5.8; Median, 1.7) higher 25-hydroxyvitamin D was observed in tears compared to serum in the subjects.
In addition, a positive correlation was observed between serum and tear 25-hydroxyvitamin D levels (r = 0.5595; p < 0.0001).
Source: ResultsAbstract: Conclusions
A higher level of 25-hydroxyvitamin D was observed in the tear fluid compared to that of the serum. It would be beneficial to consider tear vitamin D levels to study its role with reference to ocular surface diseases.
Source: ConclusionsAuthors’ abstract
Background
Vitamin D deficiency is associated with a range of systemic diseases including ocular disorders. The objective of this study is to measure tear vitamin D levels and investigate the correlation between serum and tear vitamin D levels.
Methods
A total of 48 healthy volunteers without any systemic and ocular disease were recruited for this observational cohort study. Serum was collected using clot activator coated Vacutainer® Plus tubes. Tear fluid was collected using Schirmer’s strips. Serum and tear total 25-hydroxyvitamin D levels were measured by competitive chemiluminescent ELISA and the correlation between the levels were studied.
Results
The measured serum 25-hydroxyvitamin D level ranged between 3.3 and 27.5 ng/ml (Mean ± SEM, 9.4 ± 0.7 ng/ml; Median 8.4 ng/ml). Significantly (p < 0.0001) higher level of 25-hydroxyvitamin D was detected in the tears (Mean ± SEM, 17.0 ± 1.6 ng/ml; Range 3.2 to 45.8 ng/ml; Median, 16.3 ng/ml) compared to serum. An average of ~2 fold (Mean ± SEM, 1.9 ± 0.2; Range 0.4 to 5.8; Median, 1.7) higher 25-hydroxyvitamin D was observed in tears compared to serum in the subjects.
In addition, a positive correlation was observed between serum and tear 25-hydroxyvitamin D levels (r = 0.5595; p < 0.0001).
Conclusions
A higher level of 25-hydroxyvitamin D was observed in the tear fluid compared to that of the serum. It would be beneficial to consider tear vitamin D levels to study its role with reference to ocular surface diseases.
Publication and source details
Original title: Correlation between tear fluid and serum vitamin D levels
Swaminathan Sethu; Rohit Shetty; Kalyani Deshpande; Natasha Pahuja; Nandini Chinnappaiah; Aarti Agarwal; Anupam Sharma; Arkasubhra Ghosh
Eye and Vision · 2016
© The Author(s). 2016https://creativecommons.org/licenses/by/4.0/ Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/) applies to the data made available in this article, unless otherwise stated.Narayana Nethralaya Foundation, Bangalore, IndiaRepository JATS snapshot; version as supplied
Source retrieved: 2026-11-11T06:12:23.134807+00:00
DOI: 10.1186/s40662-016-0053-7 · PMC5009644