Primary relevance to vitamin D Vitamin D is a stated subject of this paper.
Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.
Why this paper is included
Supporting source evidence:
At the 95% confidence interval, mean tear fluid vitamin D = 37.8 ± 3.6 ng/mL, which is higher than the serum level, with a mean of 30.3 ± 7.7 ng/mL; Lin's concordance correlation coefficient = −0.018 (−0.174; 0.139), Pearson's coefficient = −0.070, and the Bland‐Altman coefficient = −11.12 (−30.40; 8.16).
Source: Abstract. View original paper
Relevance classification does not establish study quality, causation or editorial approval.
Study design Study design awaiting verification.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.
Meta-analysis unclear · Blinding unclear / not reported · Research setting awaiting verification
How this paper was classified
Automatic source-based classification; awaiting editorial verification. This is not a quality score.
What the study types mean
- Systematic review
- Uses explicit methods to identify, assess and summarise research on a defined question.
- Scoping review
- Maps the extent and characteristics of research on a topic.
- Narrative review
- Discusses existing research; systematic-review methods have not been established by this classification.
- Review / evidence synthesis
- Reviews existing research; the exact review methods need further assessment.
- Randomised controlled trial
- Assigns participants or groups to comparison interventions by chance.
- Non-randomised intervention study
- Examines an intervention without random allocation.
- Cohort study
- Examines exposures and outcomes over time within a defined group.
- Case-control study
- Compares people with an outcome against people without it, examining exposures.
- Cross-sectional study
- Examines a population at a particular point in time.
- Observational study
- Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
- Case report
- Describes an individual case.
- Case series
- Describes a group of individual cases.
- Secondary analysis
- Analyses existing study data; this paper is not automatically another independent trial.
- Laboratory study
- Investigates biological processes in a laboratory setting.
- Qualitative study
- Examines experiences or meanings using qualitative methods.
- Genetic instrumental-variable study
- Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
- Study protocol
- Describes planned methods and is not evidence that the planned study has reported results.
- Multiple reported designs
- More than one design is explicitly reported; examine the supporting methods.
- Study design awaiting verification
- The available source does not establish a sufficiently clear study design.
Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.
Abstracts
Determination of vitamin D in tears of healthy individuals by the electrochemiluminescence method
Study design awaiting verification · Journal of Clinical Laboratory Analysis · 2019
Original publication title
Determination of vitamin D in tears of healthy individuals by the electrochemiluminescence method
© 2018 The Authors Journal of Clinical Laboratory Analysis Published by Wiley Periodicals, Inc.
Original publication · Publisher record · CC BY 4.0
Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.
At a glance
Abstract: What background does the paper provide?
Vitamin D is a fat‐soluble steroid hormone which can be converted into various forms and is of extreme physiological importance to our body. However, its functions and local metabolic pathways in some organs, such as the eye, have not yet been well studied. We aimed to verify the correlation between vitamin D levels in blood and tear fluid and the possibility of using tear fluid as a biological material for monitoring eye disorders in the future.
Source: BackgroundAbstract: What methods does the paper describe?
The electrochemiluminescence method was used to examine blood and tear samples collected with Schirmer test strips from 21 individuals without ocular disease.
Source: MethodsAbstract: Results
At the 95% confidence interval, mean tear fluid vitamin D = 37.8 ± 3.6 ng/mL, which is higher than the serum level, with a mean of 30.3 ± 7.7 ng/mL; Lin's concordance correlation coefficient = −0.018 (−0.174; 0.139), Pearson's coefficient = −0.070, and the Bland‐Altman coefficient = −11.12 (−30.40; 8.16). Results were obtained using the program Stata version 11.0.
Source: ResultsAbstract: Conclusion
It is possible to determine vitamin D levels in tear fluid using the electrochemiluminescence method, and as the results do not correlate with blood, there is possibility of using tear fluid as a biological matrix for detection of vitamin D, which may increase the possibilities of new studies in eye disorders.
Source: ConclusionAuthors’ abstract
Background
Vitamin D is a fat‐soluble steroid hormone which can be converted into various forms and is of extreme physiological importance to our body. However, its functions and local metabolic pathways in some organs, such as the eye, have not yet been well studied. We aimed to verify the correlation between vitamin D levels in blood and tear fluid and the possibility of using tear fluid as a biological material for monitoring eye disorders in the future.
Methods
The electrochemiluminescence method was used to examine blood and tear samples collected with Schirmer test strips from 21 individuals without ocular disease.
Results
At the 95% confidence interval, mean tear fluid vitamin D = 37.8 ± 3.6 ng/mL, which is higher than the serum level, with a mean of 30.3 ± 7.7 ng/mL; Lin's concordance correlation coefficient = −0.018 (−0.174; 0.139), Pearson's coefficient = −0.070, and the Bland‐Altman coefficient = −11.12 (−30.40; 8.16). Results were obtained using the program Stata version 11.0.
Conclusion
It is possible to determine vitamin D levels in tear fluid using the electrochemiluminescence method, and as the results do not correlate with blood, there is possibility of using tear fluid as a biological matrix for detection of vitamin D, which may increase the possibilities of new studies in eye disorders.
Publication and source details
Original title: Determination of vitamin D in tears of healthy individuals by the electrochemiluminescence method
Yu Tsun Lai; Renato Galão Cerquinho; Matheus Moreira Perez; Beatriz da Costa Aguiar Alves; Edimar Cristiano Pereira; Ligia Ajaime Azzalis; Virginia Berlanga Campos Junqueira; Lismeia Raimundo Soares; Fernando Luiz Affonso Fonseca
Journal of Clinical Laboratory Analysis · 2019
* CorrespondenceFernando L. A. Fonseca, Laboratório de Análises Clínicas da FMABC, Santo André, Brazil.
Email: profferfonseca@gmail.com
© 2018 The Authors Journal of Clinical Laboratory Analysis Published by Wiley Periodicals, Inc.https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
Repository JATS snapshot; version as supplied
Source retrieved: 2026-11-11T20:03:31.041665+00:00
DOI: 10.1002/jcla.22830 · PMC6528589