Vitamin D3 for Life. Live Enlightened.

Research libraryVitamin D3 For Life
Study design and methods

Primary relevance to vitamin D Vitamin D is a stated subject of this paper.

Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.

Why this paper is included

Supporting source evidence:

We found serum PTH fragments associated with vitamin D deficiency in patients with and without T2DM.

Source: Abstract. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Study design awaiting verification.

Study design awaiting verification

The available source does not establish a sufficiently clear study design.

Meta-analysis unclear · Blinding unclear / not reported · Human research reported

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

All study procedures were followed as per ethical standards of the Declaration of Helsinki and the Universal International Conference on Harmonization-Good Clinical Practice (ICH-GCP) guidelines laid down for human participants.

Source: Methods.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Full studies

Multiple Reaction Monitoring-Mass Spectrometric Immunoassay Analysis of Parathyroid Hormone Fragments with Vitamin D Deficiency in Patients with Diabetes Mellitus

Study design awaiting verification · Proteomes · 2024

Original publication title

Multiple Reaction Monitoring–Mass Spectrometric Immunoassay Analysis of Parathyroid Hormone Fragments with Vitamin D Deficiency in Patients with Diabetes Mellitus

Hicham Benabdelkamel; Refat M. Nimer; Afshan Masood; Maha Al Mogren; Anas M. Abdel Rahman; Assim A. Alfadda

© 2024 by the authors.

Original publication · Publisher record · CC BY 4.0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

Authors’ conclusion

Utilizing this technique may provide significant benefits to clinical research laboratories, particularly in methods requiring the monitoring of numerous PTH variants or when analyzing samples that consist of a complex mixture of PTH-derived peptides and components resulting from the digestion of compounds within the sample matrix.

In addition, our findings suggest that PTH proteoforms have significant potential as biomarkers for monitoring calcium homeostasis, particularly in patients with T2DM who also experience vitamin D deficiency. Future research should focus on validating these proteoforms in larger cohorts to establish their clinical utility and potential for improving patient outcomes.

An extract from the source publication. Read it in context.

At a glance

Study background

What background does the paper provide?

The parathyroid hormone (PTH) is a peptide hormone that, along with 25-hydroxyvitamin D (VitD), is important for regulating bone metabolism and calcium homeostasis. Aside from their action on the bone, previous studies have linked altered levels of PTH and Vit D with increased insulin resistance and the risk of developing metabolic disease [1,2,3]. Metabolic diseases, including type 2 diabetes mellitus (T2DM), are known to cause metabolic derangements that potentially affect bone mineral metabolism and the parathyroid axis.

Several studies have extensively documented the link between a deficiency in vitamin D and the development of prediabetes and diabetes [4,5,6]. Vitamin D deficiency can be categorized as deficient if levels are less than 50 nmol/L, insufficient between 50 and 70 nmol/L, and sufficient if more than 75 nmol/L [7]. The concentration of extracellular calcium primarily regulates the release of PTH. However, it may also be influenced by blood phosphate and 1,25(OH)2D levels.

When vitamin D levels are low, it can lead to decreased calcium absorption in the intestines. Low vitamin D can also result in reduced calcium levels in the blood. In response to low blood calcium, the parathyroid glands release PTH [8], resulting in an inverse relationship between the Vit D and PTH levels, clinically referred to as secondary hyperparathyroidism [9]. Although this is seen in many cases, not all Vit D deficient individuals manifest with increased PTH levels, and about 10% of diabetic patients with severe vitamin D deficiency have a low PTH [10].

This raises the question of the measurement method and the proteoforms detected.

PTH is synthesized by the pituitary glands in a pre-pro form, which is cleaved to the active secreted hormone. The pre-PTH (115 amino acids) is trimmed by 25 amino-terminal residues (−6 to −31) to form pro-PTH (90 amino acids), which is further cleaved to the biologically active 84 amino acids and intact PTH (iPTH) (PTH1-84) [11]. PTH’s biological activity arises from PT binding, and several biologically active C-terminal and N-terminal fragments (proteoforms) have been identified in circulation. The term “proteoform” has recently gained recognition for protein derivatives arising from various processes, such as posttranslational processing, genetic polymorphisms, mutations, or truncations [12,13,14].

Several proteoforms of PTH have been identified in vivo, among which PTH (7–84) is the primary proteolytic PTH fragment produced by actions of cathepsins B and H. The current method of regulation for these proteoforms is as yet unidentified. Previously considered inert, these proteoforms are now known to have biochemical actions distinct from the active 84 amino acid hormone [15]. Recent studies indicate that the levels of PTH (7–84) and other amino-truncated PTH fragments increase considerably in diseases such as renal failure, chronic heart diseases, and bone disorders [16,17,18].

Moreover, a recombinant form of human PTH (1–34) was the first anabolic drug approved for the treatment of osteoporosis [19]. However, the precise identity of various PTH fragments and their clinical associations remains uncertain (Figure 1).

The quantitation of PTH is traditionally conducted using immunoassays to diagnose primary hyperparathyroidism and hypoparathyroidism and monitor disorders of the bone. PTH assays based on first-generation immunoassay utilize a single polyclonal antibody that targets PTH’s C-terminal or midterminal part. Since these assays measure several biologically inactive C-terminal fragments, specific PTH assays, such as second- and third-generation assays that differentiate between different truncated forms of PTH, are used instead of this approach [20,21]. Second-generation assays—termed intact PTH assays—suffer from interferences from multiple circulating fragments.

Recently, third-generation assays were developed, which were considered far more specific than their previous counterparts and were considered to differentiate between these truncated forms [22,23]. Although serum PTH determination assays have significantly advanced, several limitations are associated with the immunometric generations of assessment PTH fragments. These limitations include difficulties in accurately quantifying specific pieces, the possibility of interference from non-PTH molecules, and the requirement for standardized assays to enhance reliability in clinical interpretations. The task of standardization was taken up by the International Federation of Clinical Chemistry (IFCC) working group that is working on PTH standardization and has provided the perspectives and priorities for the improvement of PTH measurement [24,25].

Therefore, new analytical approaches are needed to assess known PTH variations accurately and evaluate additional potential proteoforms simultaneously. Previous studies have utilized mass spectrometry to identify the different proteoforms of PTH in the plasma and serum [26,27,28,29,30].

Mass spectrometric immunoassay (MSIA) has recently gained significant attention in bioanalysis and biomarker discovery due to its exceptional specificity and sensitivity [31,32]. MSIA is a powerful technique that combines the strengths of immunoassay and mass spectrometry (MS) detection. The first demonstration of MSIA with matrix-assisted laser desorption/ionization (MALDI)-MS method was used to detect myotoxin α, utilizing antibodies that were derivatized onto agarose beads [33]. In addition, various proteoforms have been identified and quantified by validated MSIA approaches, such as apolipoprotein A-I, apolipoprotein C-III, insulin-like growth factor 1, and serum amyloid A [34,35,36,37].

In this study, we describe MSIA, specially tailored for detecting PTH proteoforms, and assess additional microheterogeneity in PTH related to vitamin D deficiency among patients with diabetes mellitus.

Source: 1. Introduction Source: 1. Introduction Source: 1. Introduction Source: 1. Introduction Source: 1. Introduction

Study methods

What methods does the paper describe?

2.1. Materials and Chemicals

The mouse anti-parathyroid hormone (PTH) antibody, clone 3H9 (Cat. No MA1-83384), was obtained from Thermofisher Scientific (Waltham, MA, USA). The 20X modified Dulbecco’s Phosphate buffered saline (PBS) buffer (Cat. No. 28344) was obtained from Thermofisher Scientific, 20X modified Dulbecco’s Phosphate buffered saline Tween-20 (PBST) buffer (Cat. No. 28346) was obtained from Thermofisher Scientific, MSIA D.A.R.T Protein A/G 96 tips (Cat. No. 991PRT15) (Thermo Scientific, Waltham, MA, USA), and Finnipipette Novus Multichannel Electronic Pipette and stand (Thermo scientific). Acetonitrile (ACN), methanol (MeOH), formic acid (FA) dithiothreitol (DTT), iodoacetamide (IAA), and ammonium bicarbonate (ABC) were purchased from Sigma-Aldrich (St.

Louis, MO, USA). RapiGest SF MS detergent was purchased from Waters Corporation (Milford, MA, USA). Both labeled (13C6, 15N2 labeled Lys and 13C6, 15N4 labeled Arg) and unlabeled peptides were synthesized by Biomatik Corporation (Kitchener, ON, Canada) with a minimum purity of 95%, aliquoted in 5 mg vials as dried pellets.

2.2. Subjects and Blood Samples

2.2.2. Participant Recruitment and Sample Collection

We recruited forty patients with T2DM whose primary physician followed the King Saud University Medical City outpatient clinics. All patients had T2DM and no associated comorbidities. Samples were collected after a 10 h fast in EDTA tubes (Vacutainer, BD Biosciences, San Jose, CA, USA) by venipuncture. After centrifugation (15 min, 3000× g), plasma was separated, divided into several aliquots, and stored at −80 °C for further analysis. Routine laboratory investigations and estimations for 25 (OH) Vit D levels were carried out at the central biochemistry lab at KKUH.

Patients with T2DM were assessed for their Vit D levels and grouped according to their vitamin D status. Patients with Vit D more than 75 nmol/L were considered as T2DM with normal vitamin D (DN, n = 20), and those with VitD levels less than 50 nmol/L (DD, n = 20) were considered as T2DM with deficient VitD.

2.3. Signature Peptide Selection

The protein sequence of the human parathyroid hormone (PTH) from the species homo sapiens, identified by the accession number P01270, was acquired from the protein database of the National Center for Biotechnology Information (NCBI). To generate potential signature peptides, trypsin mediated in silico digestion was performed using the PeptideMass tool available on the Expasy bioinformatics resource portal [38]. The peptides were subsequently analyzed using the Basic Local Alignment Search Tool (BLAST) to compare them with other protein sequences in the NCBI database and verify their distinctiveness.

Selecting signature peptides involved a multi-step process. First, each signature peptide length range was between 5 and 25 amino acids for the best performance in experiments. Second, water solubility assessments were performed using Innovagen’s peptide calculator (https://pepcalc.com/). Thirdly, the ProtParam tool (http://web.expasy.org/protparam/, accessed on 1 June 2023) was used to monitor peptide stability. Fourthly, the SIM alignment tool was utilized to confirm that all chosen peptides belonged exclusively to PTH and did not match with any other proteins present in the sample.

Finally, posttranslational modifications (PTMs), including methylation, glycosylation, and phosphorylation, were verified using the UniProt and Phospho.ELM databases to ensure accuracy when measuring target proteins. Six distinct peptides, 32SVSEIQLMHNLGK44 (PTH-G1), 38LMHNLGK44 (PTH-G2), 45HLNSMER51 (PTH-G3), and 60DQVHNFVALGAPLAPR75 (PTH-G4), 65FVALGAPLAPR75 (PTH-G5), and 104ADVNVLTK111 (PTH-G6), were synthetically produced for the preparation of calibration curves. These peptides were produced in regular and stable-isotope-labeled forms, serving as internal standards (ISs). The materials, whose purity was greater than 95% as determined by high-performance liquid chromatography (HPLC), were subjected to peptide sequence identification.

This analysis focused specifically on determining the location of the labeling using high-resolution mass spectrometry (HRMS). The supplier certifies the quality of the standard materials, providing HPLC chromatograms and MS spectra for each standard material.

2.4. MRM Transition Development

2.4.1. Stock and Working Solution Preparation

For each labeled and unlabeled peptide, a 1.0 mg/mL stock solution in H2O was prepared. To tune the mass spectrometric conditions and optimize the chromatography, a 10.0 µg/mL working solution for each peptide was diluted in mobile phase A:B (0.1% FA in H2O:0.1% FA in 50% (v/v) ACN:MeOH).

2.4.2. LC-MS/MS Analysis

As previously described in our prior study [39], a 10.0 ug/mL working solution of each labeled and unlabeled peptide was introduced into an LC-MS system (Waters Acquity UPLC coupled with XEVO TQ-MS (Waters Corporation, Milford, MA, USA)), using positive-ionization electrospray (+ESI) at a 0.3 mL/min flow rate. Chromatographic separation occurred via ultra-high-pressure liquid chromatography UHPLC BEH C18 columns (1.7 μm, 2.1 × 100 mm). The chromatographic separation was performed using a gradient elution profile. The flow rate was set to 0.3 mL/min throughout the run.

The initial composition of the mobile phase was 90% solvent A (0.1% formic acid in H2O) and 10% solvent B (0.1% FA in 50% (v/v) ACN:MeOH). After 1 min, a linear gradient was applied over 10 min, shifting the composition to 10% solvent A and 90% solvent B. Afterward, the composition returned to the initial conditions (90% solvent A and 10% solvent B) within 1 min. The mobile phase remained at this composition for the final 3 min, making the total run time 15.

The injection volume was set at 10 µL. Modifications were made to the general mass spectrometry (MS) parameters for LC-MS/MS. The ion source desolvation temperature was maintained at 450 °C. The flow rates for the ion source desolvation and cone gasses were set at min900 L/h and 50 L/h, respectively. The MS capillary and cone voltages were also set at 2 kV and 40 V, respectively.

2.5. Preparation of Plasma Sample and Enrichment Using MSIA DARTs

The patient’s samples were taken and prepared according to the Thermo Scientific protocol using protein A/G MSIA Disposable Automation Research Tips (DARTs) to obtain the proteins of interest. The Novus i multichannel pipette was loaded with protein A/G MSIA™-Tips, and repeated cycles of aspiration and dispersion were carried out, as outlined in Table 1, for the immunopurification of the target protein. Briefly, the plasma samples were diluted ten times with PBST, and then the 15 μL from this was mixed with 135 μL of PBS (100×) and added into the column.

The tips were conditioned with PBS before binding 100 μL (0.05 mg/mL) of the mouse anti-PTH polyclonal antibody, clone 3H9 (100× plasma) that identifies the intact PTH peptide at the epitopes 1-34 and 1-84 (Cat-MA1-833384, Thermofisher, Waltham, MA, USA) to the protein’s A/G immobilized on the monolithic adsorbent surface (Figure 2). The target analytes (natural PTH proteoforms) were extracted from plasma by forming an antibody–antigen complex. Unbound antibody residues were removed with PBS and water after four consecutive washing steps.

The natural PTH proteoforms from the samples were then eluted into tubes using an elution buffer (40% acetonitrile and 0.4% TFA in distilled water) (Table 1). They were dried using a speed vacuum centrifuge.

2.5.1. In-Solution Tryptic Digestion

The tryptic digestion protocol was carried out by initially dissolving the proteins in 40 μL ammonium bicarbonate (50 mM) followed by incubation in the presence of dithiothreitol (DTT) (Sigma, St. Louis, MO, USA) (10 mM) at 56 °C for 1 h to reduce the disulfide bonds. Protein samples were next alkylated with iodoacetamide (IAA) (Sigma, St. Louis, MO, USA) (20 mM) at room temperature in the dark for another hour and were then digested using trypsin (Promega, Madison, WI, USA) in a 1:50 trypsin-to-protein ratio and incubated at 37 °C overnight.

Lastly, 7 µL of 10% formic acid was added to stop the reaction.

2.5.2. Solid-Phase Extraction (SPE)

Solid-phase extraction (SPE) was used to purify and concentrate the tryptic peptides following our standard protocol [40]. The Oasis HLB 1 cc 30 mg cartridge (Waters Oasis PRiME, Milford, MA, USA) was first conditioned with 100% methanol and then dH2O to wet the sorbent. Before running the samples through the sorbent, they were mixed with labeled peptides and diluted using a loading buffer (0.1% FA in dH2O). Unwanted substances were washed with dH2O twice.

Tryptic peptides were eluted using a solution comprising 0.1% formic acid (FA) in 50% acetonitrile (ACN). Following drying using the Savant(tm) DNA Concentrator SpeedVac (Thermo Scientific, USA), dried extracts were reconstitution in a 100 μL mixture consisting of 90% A (0.1% formic acid in H2O) before being analyzed using LC-MSMS.

2.6. LC-MS/MS Method Validation Protocol

The validation study followed the FDA guideline [41,42], and the samples were analyzed on LC-MSMS, as detailed in Section 2.4.2.

2.6.1. Linearity Verification

A mixture of unlabeled peptides with a concentration of 20 µg/mL was used to generate a calibration curve (0.1–1000 nM) and QC samples (1.5, 35, and 75 nM) prepared in an extracted matrix. This matrix was prepared from pooled serum samples, where the proteins were precipitated with an equal volume of acetone, and the pellets were resuspended with PBS buffer and digested tryptic. A constant amount (20 µL) of internal standard (20 µg/mL) was added to each sample and was run on the method detailed in Section 2.4.2.

Calibration curves for peptides were generated over three consecutive days and executed to evaluate linearity. The peptide signals, expressed as area ratios (standard area/internal standard area, IS), were plotted on the y-axis. In contrast, the nominal concentrations of the standard solutions were plotted on the x-axis. The linearity of the peptide signals was determined through regression analysis, measuring the correlation coefficient (R2) and the precision and accuracy at different calibration levels.

2.6.2. Limits of Detection

Three-day calibration curves provided an opportunity to establish limits of detection (LOD) and lower limits of quantification (LLOQ) for each peptide. LLOQ was defined as the lowest point on a calibration curve with signal at or exceeding 10× standard deviation of blank signal; S/N ratios were at least three or ten, depending on the concentration level for both concentrations; accuracy should range between 80 and 120% with daily variance less than 20%. Consequently, LLOD was adjusted so as to achieve an S/N ratio ≥3.

2.6.3. Inter- and Intraday Validation

Three quality control (QC) concentration levels—low (LQC), medium (MQC), and high (HQC)—were utilized to evaluate the precision and accuracy of the method. This involved the analysis of six samples from each QC level, both on the same day, to assess intraday precision (repeatability) and over three different days for interday precision (reproducibility) to determine repeatability. The signal variability in this study was evaluated using the percent relative standard deviation (RSD). For each quality control (QC) sample, the intraday precision was calculated by the following formula: [(standard deviation of measured QC concentrations on a given day x)/(mean of measured concentrations on day x)] × 100%.

Similarly, the interday precision was calculated as follows: [(standard deviation of measured QC concentrations over three days)/(mean of these measured concentrations over the three days)] × 100%. This study aimed to maintain a day-to-day variation below 20%. Intraday accuracy for each QC was calculated using the following formula: [(mean measured concentration)/(nominal concentration)] × 100%. The interday accuracy calculation followed the formula: [(mean measured concentration over three days)/(nominal QC concentration)] × 100%. For calibrators, accuracy within the 80–120% range for the limit of quantitation (LOQ) and 85–115% for other standard levels was considered acceptable.

2.6.4. Stability of Peptide

Three quality control (QC) samples (high, medium, and low) were extracted and stored at different temperatures, such as room temperature (RT), refrigeration (4 °C), and freezing (−20 °C), to test the storage stability of selected signature peptides. These conditions were compared with those of freshly prepared QC samples. The assessment of storage stability for each QC level involved determining the molecular stability. This was accomplished by multiplying the average area ratio of the analyzed sample with that of the fresh sample and multiplying the result by 100%.

2.6.5. Carryover

The highest standard was injected six times to assess the assay carryover, followed by injecting three blank samples. Carryover should not exceed 20% of LLOQ [43].

2.7. Data and Statistical Analysis

Statistical data analysis was performed using the Statistical Package for Social Sciences (SPSS) version 26 (SPSS Inc., Armonk, NY, USA) for the clinical variables between the two groups, and a p-value of less than 0.05 was considered statistically significant.

The LC-MS/MS MassLynx software, version 4.1 (Waters Corporation, Milford, MA, USA), was used to acquire, process, and visualize the data. The data for quantitative signals were displayed as mean values and SD. The protein levels of PTH G1-6 in patients with T2DM associated with vitamin D deficiency were compared to those in a group with normal vitamin D levels LC-MS/MS. Statistical analysis was performed using GraphPad Prism 6.01 (La Jolla, CA, USA), and p-values of less than 0.05 were considered significant.

Table 1

Pipetting scheme for PTH purification using a Thermo Finnpipette™ Novus i Multichannel Electronic Pipette equipped with Protein A/G MSIA™-Tips.

1
Wash
2
Immobilization of Antibody
3
Wash
4
Antigen Capture
5
Wash
6
Wash
7
Wash
8
Wash
9
Elution
LiquidPBS100 μL (0.05 mg/mL) of the Mouse Anti Parathyroid Hormone (PTH) Antibody10 mM PBS150 μL of 100× Diluted Plasma in PBST10 mM PBS10 mM PBSLC/MS Grade WaterLC/MS Grade Water40% Acetonitrile and 0.4% TFA LC/MS Grade Water
Asp/Disp cycles10×250×10×100×10×10×10×10×10×
Cycle volume (μL)150801501001501501501507
Total well volume (μL)20010020010020020020020010
Source: 2. Materials and Methods Source: 2. Materials and Methods Source: 2. Materials and Methods Source: 2. Materials and Methods Source: 2. Materials and Methods Source: 2. Materials and Methods Source: 2. Materials and Methods Source: 2. Materials and Methods Source: 2. Materials and Methods

Basic and Biochemical Characteristics

Results and Discussion: Basic and Biochemical Characteristics

The basic characteristics and results of the biochemical parameters of the patients are described in Table 2. All the patients in the study had T2DM with either normal vitamin D levels or vitamin D deficiency. The mean age of patients with vitamin D deficiency was 45.3 ± 10.6, while those with normal vitamin D levels were 50.3 ± 13.2. There was no significant difference in the ages between the two groups and other biochemical parameters. A significant difference was noted only in the vitamin D levels between the groups (p < 0.01).

Table 2

Biochemical parameters of patients with T2DM and without vitamin D deficiency.

ParameterVitamin D Deficiency (n = 20)Normal Vitamin D (n = 20)p-Value
Male/Female (%)60/4070/30NA
Age (years) 45.3 ± 10.650.3 ± 13.20.12
Glucose (mmol/L)6.3 ± 0.87.2 ± 0.50.09
Urea (mmol/L)4.3 ± 0.94.6 ± 0.80.26
Creatinine (umol/L)71.1 ± 12.775.3 ± 12.00.074
Sodium (mmol/L)132.6 ± 5.1136.3 ± 5.90.13
Potassium (mmol/L)4.2 ± 0.24.3 ± 0.40.40
Aspartate transaminase (IU/L)44.8 ± 9.141.8 ± 4.50.38
Alanine transaminase (IU/L)19.5 ± 518.8 ± 2.00.4
Alkaline phosphatase (IU/L)97.6 ± 13.793.2 ± 28.90.3
Total cholesterol (mmol/L)4.6 ± 1.04.9 ± 0.80.10
HDL cholesterol (mmol/L)1.2 ± 0.21.4 ± 0.20.2
LDL cholesterol (mmol/L)2.8 ± 0.93.1 ± 0.70.09
Triglycerides (mmol/L)1.8 ± 0.62.5 ± 0.20.07
vitamin D (nmol/L)27.7 ± 9.397.5 ± 22.9<0.01 *

Values are presented as mean ± SD. * p  < 0.05.

Source: 3.1. Basic and Biochemical Characteristics Source: 3.1. Basic and Biochemical Characteristics

Signature Peptide Selection and LC-MS/MS Method Development

Results and Discussion: Signature Peptide Selection and LC-MS/MS Method Development

The protein sequences and isoforms of PTH (UniProt ID: P01270) were obtained from the human UniProt-FASTA database. Following the performance of in silico tryptic digestion on the PTH using PeptideMass, we could select signature peptides, which we confirmed with Skyline Software (version 19.1, Washington, DC, USA). The PTH’s signature peptides were chosen according to well-established criteria in the Methods section [39].

Table S1 details the characteristics of PTH-specific signature peptides selected for absolute quantification purposes, with light and heavy signature peptides acting as standards and internal standards (ISs). Calibration curves were constructed to measure signals using standard reference materials; furthermore, heavy isotopically labeled peptides have identical amino acid sequences and physical/chemical properties as the light peptides to maintain consistent ionization efficiency between unknown samples and calibration curves [44].

In this study, an internal standard (IS) version of each peptide was utilized, co-eluting at a similar retention time [45]. This approach corrected various analytical discrepancies, including differences in ionization efficiency, suppression, and the normalization of the signal. Thus, it helped determine concentrations using a calibration curve, where the response is based on the area ratio of the signature peptides to their internal standard [46].

Source: 3.2. Signature Peptide Selection and LC-MS/MS Method Development Source: 3.2. Signature Peptide Selection and LC-MS/MS Method Development Source: 3.2. Signature Peptide Selection and LC-MS/MS Method Development

Validation of LC-MS/MS Method

Results and Discussion: Validation of LC-MS/MS Method

The method validation was performed in accordance with the guidelines set by the FDA [41,42].

3.3.1. Curve Linearity

A calibration curve is used to set the quantification range and linearity of measurements for each of the chosen PTH signal peptides that correspond to each PTH variant (aa32–44, aa38–44, aa45–51, aa60–75, aa65–75, and aa104–111).

Figure 3A,B show the extracted ion chromatograms of the PTH signature peptides (1 to 6), along with their labeled internal standards. The calibration curves for PTH variants exhibited excellent linearity over the range of 2.0 to 1000 nM with good linearity (r2 = 0.9999, 0.9982, 0.9990, 0.9999, 0.9999, and 0.9999, respectively).

3.3.2. Specificity and Sensitivity

Table S2 summarizes the findings of the method’s sensitivity evaluation, which was conducted according to the procedures outlined in the Methods Section 2.

PTH signature peptides were assessed over three days with an LLOQ of 2.0 nM, which was confirmed through triplicate measurement over multiple trips in triplicate, along with method linearity analysis that yielded coefficients of determination (R2) values between 0.9999, 0.9982, 0.9990, 0.9999, 0.9999 and 0.9999.

The absence of interferences with identical MRM transition and retention times characterizes specificity. The method’s specificity was assessed using LC-MS/MS. Furthermore, the blank sample from the carryover experiment described in the Methods section did not show any significant signal, amounting to less than 20% of the LLOQ.

3.3.3. Inter- and Intraday Precision

Accuracy and precision were measured for PTH variants by analyzing six replicates of LQC, MQC, and HQC samples (25 nM, 150 nM, and 750 nM, respectively) on the same day (intraday) and three other days (interday) to meet the acceptance limits set by ICH; interday variability for selected signature peptides ranged between 15 and 17% while accuracy ranged between 80 and 120% among the quality controls (Table S3) [31]. Intraday accuracy ranged between 95.69 and 104.07%, with precision levels below 15 (Table S4).

3.3.4. Peptide Stability Study

Three QC samples were used at three different concentrations (1.5, 35.0, and 75.0 nM) to evaluate the stability of the PTH signature peptides for the six variants. A stability assessment was conducted under various storage circumstances, including 24 h at room temperature, one week at 4 °C, two weeks at −20 °C, and one month at −20 °C. The stability of the selected signature peptides varied between 76.7% and 113.1% (Table S5).

Source: 3.3. Validation of LC-MS/MS Method Source: 3.3. Validation of LC-MS/MS Method Source: 3.3. Validation of LC-MS/MS Method Source: 3.3. Validation of LC-MS/MS Method Source: 3.3. Validation of LC-MS/MS Method

Evaluation of Clinical Samples

Results and Discussion: Evaluation of Clinical Samples

PTH variant concentrations were measured using their corresponding signature peptides (PTH-G-1-G-5). There was a significant increase in PTH-G-2 (aa38–44), PTH-G-3 (aa45–51), and PTH-G-5 (aa65–75) among the patients with T2DM associated with vitamin D deficiency compared to the normal vitamin D group (p < 0.0001) (Figure 4).

The diagnostic values of PTH-G-2, PTH-G-3, and PTH-G-5 were assessed using receiver-operating characteristic (ROC) curves, as shown in Figure 5. The ROC curve plots the sensitivity (true positive rate) on the y-axis and the specificity (false positive rate) on the x-axis. The top left corner of the diagram represents the “ideal” position, characterized by zero false positives and one real positive. An ideal test has a maximum area under the receiver operating characteristic (ROC) curve (AUC) of one.

The area under the curve (AUC) values for PTH-G-2, PTH-G-3, and PTH-G-5 in individuals with T2DM and vitamin D deficiency, as well as those with T2DM and normal vitamin D levels, were 0.9950 (95% confidence interval [CI], p < 0.0001), 0.9375 (95% CI, p < 0.0001), and 1.000 (95% CI, p < 0.0001), respectively. Thus, PTH-G-2, PTH-G-3, and PTH-G-5 showed superior diagnostic and analytical capabilities in distinguishing between individuals with T2DM and vitamin D deficiency and those with T2DM and normal vitamin D levels.

The expression ratios for the peptides between people with diabetes with vitamin D deficiency (DD) and with normal (DN) levels ranged from 0.91 for ADVNVLTK (aa104–111) to 26.09 for FVALGAPLAPR (aa65–75) (Table S1).

Many clinical approaches use immobilized antibodies to quantify biomarkers, which are then detected by another antibody tagged with a fluorophore, radioisotope, or reporter enzyme. The capacity of antibodies to distinguish between different biomarker polymorphic variants and truncated proteoforms in a single analysis limits these approaches. This study reports the first use of MSIA to accurately identify and quantify PTH fragments between patients with T2DM and those with vitamin D deficiency and with normal vitamin D levels, and this method was successfully validated.

Vitamin D deficiency is a risk factor for developing and worsening T2DM [47]. Lowering vitamin D levels, in turn, affects the levels of PTH and can lead to secondary hyperparathyroidism. This effect of alteration in PTH is not reflected in the conventional assays for PTH, which do not consider the presence of other PTH peptides that are biologically active. In this regard, our study shows the ability of different PTH fragments, including PTH-G-2 (aa38–44), PTH-G-3 (aa45–51), and PTH-G-5 (aa65–75), to discriminate between T2DM with vitamin D deficiency and T2DM patients with normal vitamin D levels.

Moreover, vitamin D supplementation improves calcium absorption and reduces the stimulus for PTH secretion; this may alter the balance of PTH proteoforms. Specifically, with less demand for calcium regulation, there might be a reduction in the overall secretion of PTH, which could lead to a decrease in the levels of certain PTH fragments or changes in the relative proportions of these proteoforms. However, further studies are required to establish a definitive link between vitamin D supplementation and PTH proteoform distribution.

Despite MSIA’s power to distinguish between truncated proteoforms, this method has some limitations, such as the availability of high-quality antibodies, experimental design, and the absence of signals in mass spectra [48].

Source: 3.4. Evaluation of Clinical Samples Source: 3.4. Evaluation of Clinical Samples Source: 3.4. Evaluation of Clinical Samples Source: 3.4. Evaluation of Clinical Samples Source: 3.4. Evaluation of Clinical Samples Source: 3.4. Evaluation of Clinical Samples

Results and Discussion

3.1. Basic and Biochemical Characteristics

The basic characteristics and results of the biochemical parameters of the patients are described in Table 2. All the patients in the study had T2DM with either normal vitamin D levels or vitamin D deficiency. The mean age of patients with vitamin D deficiency was 45.3 ± 10.6, while those with normal vitamin D levels were 50.3 ± 13.2. There was no significant difference in the ages between the two groups and other biochemical parameters. A significant difference was noted only in the vitamin D levels between the groups (p < 0.01).

3.2. Signature Peptide Selection and LC-MS/MS Method Development

The protein sequences and isoforms of PTH (UniProt ID: P01270) were obtained from the human UniProt-FASTA database. Following the performance of in silico tryptic digestion on the PTH using PeptideMass, we could select signature peptides, which we confirmed with Skyline Software (version 19.1, Washington, DC, USA). The PTH’s signature peptides were chosen according to well-established criteria in the Methods section [39].

Table S1 details the characteristics of PTH-specific signature peptides selected for absolute quantification purposes, with light and heavy signature peptides acting as standards and internal standards (ISs). Calibration curves were constructed to measure signals using standard reference materials; furthermore, heavy isotopically labeled peptides have identical amino acid sequences and physical/chemical properties as the light peptides to maintain consistent ionization efficiency between unknown samples and calibration curves [44].

In this study, an internal standard (IS) version of each peptide was utilized, co-eluting at a similar retention time [45]. This approach corrected various analytical discrepancies, including differences in ionization efficiency, suppression, and the normalization of the signal. Thus, it helped determine concentrations using a calibration curve, where the response is based on the area ratio of the signature peptides to their internal standard [46].

3.3. Validation of LC-MS/MS Method

The method validation was performed in accordance with the guidelines set by the FDA [41,42].

3.3.1. Curve Linearity

A calibration curve is used to set the quantification range and linearity of measurements for each of the chosen PTH signal peptides that correspond to each PTH variant (aa32–44, aa38–44, aa45–51, aa60–75, aa65–75, and aa104–111).

Figure 3A,B show the extracted ion chromatograms of the PTH signature peptides (1 to 6), along with their labeled internal standards. The calibration curves for PTH variants exhibited excellent linearity over the range of 2.0 to 1000 nM with good linearity (r2 = 0.9999, 0.9982, 0.9990, 0.9999, 0.9999, and 0.9999, respectively).

3.3.2. Specificity and Sensitivity

Table S2 summarizes the findings of the method’s sensitivity evaluation, which was conducted according to the procedures outlined in the Methods Section 2.

PTH signature peptides were assessed over three days with an LLOQ of 2.0 nM, which was confirmed through triplicate measurement over multiple trips in triplicate, along with method linearity analysis that yielded coefficients of determination (R2) values between 0.9999, 0.9982, 0.9990, 0.9999, 0.9999 and 0.9999.

The absence of interferences with identical MRM transition and retention times characterizes specificity. The method’s specificity was assessed using LC-MS/MS. Furthermore, the blank sample from the carryover experiment described in the Methods section did not show any significant signal, amounting to less than 20% of the LLOQ.

3.3.3. Inter- and Intraday Precision

Accuracy and precision were measured for PTH variants by analyzing six replicates of LQC, MQC, and HQC samples (25 nM, 150 nM, and 750 nM, respectively) on the same day (intraday) and three other days (interday) to meet the acceptance limits set by ICH; interday variability for selected signature peptides ranged between 15 and 17% while accuracy ranged between 80 and 120% among the quality controls (Table S3) [31]. Intraday accuracy ranged between 95.69 and 104.07%, with precision levels below 15 (Table S4).

3.3.4. Peptide Stability Study

Three QC samples were used at three different concentrations (1.5, 35.0, and 75.0 nM) to evaluate the stability of the PTH signature peptides for the six variants. A stability assessment was conducted under various storage circumstances, including 24 h at room temperature, one week at 4 °C, two weeks at −20 °C, and one month at −20 °C. The stability of the selected signature peptides varied between 76.7% and 113.1% (Table S5).

3.4. Evaluation of Clinical Samples

PTH variant concentrations were measured using their corresponding signature peptides (PTH-G-1-G-5). There was a significant increase in PTH-G-2 (aa38–44), PTH-G-3 (aa45–51), and PTH-G-5 (aa65–75) among the patients with T2DM associated with vitamin D deficiency compared to the normal vitamin D group (p < 0.0001) (Figure 4).

The diagnostic values of PTH-G-2, PTH-G-3, and PTH-G-5 were assessed using receiver-operating characteristic (ROC) curves, as shown in Figure 5. The ROC curve plots the sensitivity (true positive rate) on the y-axis and the specificity (false positive rate) on the x-axis. The top left corner of the diagram represents the “ideal” position, characterized by zero false positives and one real positive. An ideal test has a maximum area under the receiver operating characteristic (ROC) curve (AUC) of one.

The area under the curve (AUC) values for PTH-G-2, PTH-G-3, and PTH-G-5 in individuals with T2DM and vitamin D deficiency, as well as those with T2DM and normal vitamin D levels, were 0.9950 (95% confidence interval [CI], p < 0.0001), 0.9375 (95% CI, p < 0.0001), and 1.000 (95% CI, p < 0.0001), respectively. Thus, PTH-G-2, PTH-G-3, and PTH-G-5 showed superior diagnostic and analytical capabilities in distinguishing between individuals with T2DM and vitamin D deficiency and those with T2DM and normal vitamin D levels.

The expression ratios for the peptides between people with diabetes with vitamin D deficiency (DD) and with normal (DN) levels ranged from 0.91 for ADVNVLTK (aa104–111) to 26.09 for FVALGAPLAPR (aa65–75) (Table S1).

Many clinical approaches use immobilized antibodies to quantify biomarkers, which are then detected by another antibody tagged with a fluorophore, radioisotope, or reporter enzyme. The capacity of antibodies to distinguish between different biomarker polymorphic variants and truncated proteoforms in a single analysis limits these approaches. This study reports the first use of MSIA to accurately identify and quantify PTH fragments between patients with T2DM and those with vitamin D deficiency and with normal vitamin D levels, and this method was successfully validated.

Vitamin D deficiency is a risk factor for developing and worsening T2DM [47]. Lowering vitamin D levels, in turn, affects the levels of PTH and can lead to secondary hyperparathyroidism. This effect of alteration in PTH is not reflected in the conventional assays for PTH, which do not consider the presence of other PTH peptides that are biologically active. In this regard, our study shows the ability of different PTH fragments, including PTH-G-2 (aa38–44), PTH-G-3 (aa45–51), and PTH-G-5 (aa65–75), to discriminate between T2DM with vitamin D deficiency and T2DM patients with normal vitamin D levels.

Moreover, vitamin D supplementation improves calcium absorption and reduces the stimulus for PTH secretion; this may alter the balance of PTH proteoforms. Specifically, with less demand for calcium regulation, there might be a reduction in the overall secretion of PTH, which could lead to a decrease in the levels of certain PTH fragments or changes in the relative proportions of these proteoforms. However, further studies are required to establish a definitive link between vitamin D supplementation and PTH proteoform distribution.

Despite MSIA’s power to distinguish between truncated proteoforms, this method has some limitations, such as the availability of high-quality antibodies, experimental design, and the absence of signals in mass spectra [48].

Table 2

Biochemical parameters of patients with T2DM and without vitamin D deficiency.

ParameterVitamin D Deficiency (n = 20)Normal Vitamin D (n = 20)p-Value
Male/Female (%)60/4070/30NA
Age (years) 45.3 ± 10.650.3 ± 13.20.12
Glucose (mmol/L)6.3 ± 0.87.2 ± 0.50.09
Urea (mmol/L)4.3 ± 0.94.6 ± 0.80.26
Creatinine (umol/L)71.1 ± 12.775.3 ± 12.00.074
Sodium (mmol/L)132.6 ± 5.1136.3 ± 5.90.13
Potassium (mmol/L)4.2 ± 0.24.3 ± 0.40.40
Aspartate transaminase (IU/L)44.8 ± 9.141.8 ± 4.50.38
Alanine transaminase (IU/L)19.5 ± 518.8 ± 2.00.4
Alkaline phosphatase (IU/L)97.6 ± 13.793.2 ± 28.90.3
Total cholesterol (mmol/L)4.6 ± 1.04.9 ± 0.80.10
HDL cholesterol (mmol/L)1.2 ± 0.21.4 ± 0.20.2
LDL cholesterol (mmol/L)2.8 ± 0.93.1 ± 0.70.09
Triglycerides (mmol/L)1.8 ± 0.62.5 ± 0.20.07
vitamin D (nmol/L)27.7 ± 9.397.5 ± 22.9<0.01 *

Values are presented as mean ± SD. * p  < 0.05.

Source: 3. Results and Discussion Source: 3. Results and Discussion Source: 3. Results and Discussion Source: 3. Results and Discussion Source: 3. Results and Discussion

Conclusions

Utilizing this technique may provide significant benefits to clinical research laboratories, particularly in methods requiring the monitoring of numerous PTH variants or when analyzing samples that consist of a complex mixture of PTH-derived peptides and components resulting from the digestion of compounds within the sample matrix.

In addition, our findings suggest that PTH proteoforms have significant potential as biomarkers for monitoring calcium homeostasis, particularly in patients with T2DM who also experience vitamin D deficiency. Future research should focus on validating these proteoforms in larger cohorts to establish their clinical utility and potential for improving patient outcomes.

Source: 4. Conclusions Source: 4. Conclusions
Authors’ abstract

Current immunoassay techniques for analyzing clinically relevant parathyroid hormone (PTH) circulating fragments cannot distinguish microheterogeneity among structurally similar molecular species. This hinders the identification of molecular species and the capture of target analyte information. Since structural modifications are important in disease pathways, mass spectrometry can detect, identify, and quantify heterogeneous ligands captured by antibodies. We aimed to create a sensitive and selective multiple reaction monitoring–mass spectrometric immunoassay analysis (MRM-MSIA)-based method for detecting and quantifying PTH fragments or proteoforms for clinical research.

Our study established MRM transitions using triple-quadrupole tandem mass spectrometry for the signature peptides of five PTH fragments. This method was validated according to FDA guidelines, employing the mass spectrometric immunoassay (MSIA) protocol to bolster detection selectivity and sensitivity. This validated approach was applied by analyzing samples from type 2 diabetes mellitus (T2DM) patients with and without vitamin D deficiency. We found serum PTH fragments associated with vitamin D deficiency in patients with and without T2DM. We developed and validated the MRM-MSIA technique specifically designed for the detection and quantification (amino acid (aa38–44), (aa45–51), and (aa65–75)) of these fragments associated with vitamin D deficiency and T2DM.

This study is the first to accurately quantify plasma PTH fragments using MRM-MSIA, demonstrating its potential for clinical diagnostics.

Read the full paper

1. Introduction

The parathyroid hormone (PTH) is a peptide hormone that, along with 25-hydroxyvitamin D (VitD), is important for regulating bone metabolism and calcium homeostasis. Aside from their action on the bone, previous studies have linked altered levels of PTH and Vit D with increased insulin resistance and the risk of developing metabolic disease [1,2,3]. Metabolic diseases, including type 2 diabetes mellitus (T2DM), are known to cause metabolic derangements that potentially affect bone mineral metabolism and the parathyroid axis.

Several studies have extensively documented the link between a deficiency in vitamin D and the development of prediabetes and diabetes [4,5,6]. Vitamin D deficiency can be categorized as deficient if levels are less than 50 nmol/L, insufficient between 50 and 70 nmol/L, and sufficient if more than 75 nmol/L [7]. The concentration of extracellular calcium primarily regulates the release of PTH. However, it may also be influenced by blood phosphate and 1,25(OH)2D levels.

When vitamin D levels are low, it can lead to decreased calcium absorption in the intestines. Low vitamin D can also result in reduced calcium levels in the blood. In response to low blood calcium, the parathyroid glands release PTH [8], resulting in an inverse relationship between the Vit D and PTH levels, clinically referred to as secondary hyperparathyroidism [9]. Although this is seen in many cases, not all Vit D deficient individuals manifest with increased PTH levels, and about 10% of diabetic patients with severe vitamin D deficiency have a low PTH [10].

This raises the question of the measurement method and the proteoforms detected.

PTH is synthesized by the pituitary glands in a pre-pro form, which is cleaved to the active secreted hormone. The pre-PTH (115 amino acids) is trimmed by 25 amino-terminal residues (−6 to −31) to form pro-PTH (90 amino acids), which is further cleaved to the biologically active 84 amino acids and intact PTH (iPTH) (PTH1-84) [11]. PTH’s biological activity arises from PT binding, and several biologically active C-terminal and N-terminal fragments (proteoforms) have been identified in circulation. The term “proteoform” has recently gained recognition for protein derivatives arising from various processes, such as posttranslational processing, genetic polymorphisms, mutations, or truncations [12,13,14].

Several proteoforms of PTH have been identified in vivo, among which PTH (7–84) is the primary proteolytic PTH fragment produced by actions of cathepsins B and H. The current method of regulation for these proteoforms is as yet unidentified. Previously considered inert, these proteoforms are now known to have biochemical actions distinct from the active 84 amino acid hormone [15]. Recent studies indicate that the levels of PTH (7–84) and other amino-truncated PTH fragments increase considerably in diseases such as renal failure, chronic heart diseases, and bone disorders [16,17,18].

Moreover, a recombinant form of human PTH (1–34) was the first anabolic drug approved for the treatment of osteoporosis [19]. However, the precise identity of various PTH fragments and their clinical associations remains uncertain (Figure 1).

The quantitation of PTH is traditionally conducted using immunoassays to diagnose primary hyperparathyroidism and hypoparathyroidism and monitor disorders of the bone. PTH assays based on first-generation immunoassay utilize a single polyclonal antibody that targets PTH’s C-terminal or midterminal part. Since these assays measure several biologically inactive C-terminal fragments, specific PTH assays, such as second- and third-generation assays that differentiate between different truncated forms of PTH, are used instead of this approach [20,21]. Second-generation assays—termed intact PTH assays—suffer from interferences from multiple circulating fragments.

Recently, third-generation assays were developed, which were considered far more specific than their previous counterparts and were considered to differentiate between these truncated forms [22,23]. Although serum PTH determination assays have significantly advanced, several limitations are associated with the immunometric generations of assessment PTH fragments. These limitations include difficulties in accurately quantifying specific pieces, the possibility of interference from non-PTH molecules, and the requirement for standardized assays to enhance reliability in clinical interpretations. The task of standardization was taken up by the International Federation of Clinical Chemistry (IFCC) working group that is working on PTH standardization and has provided the perspectives and priorities for the improvement of PTH measurement [24,25].

Therefore, new analytical approaches are needed to assess known PTH variations accurately and evaluate additional potential proteoforms simultaneously. Previous studies have utilized mass spectrometry to identify the different proteoforms of PTH in the plasma and serum [26,27,28,29,30].

Mass spectrometric immunoassay (MSIA) has recently gained significant attention in bioanalysis and biomarker discovery due to its exceptional specificity and sensitivity [31,32]. MSIA is a powerful technique that combines the strengths of immunoassay and mass spectrometry (MS) detection. The first demonstration of MSIA with matrix-assisted laser desorption/ionization (MALDI)-MS method was used to detect myotoxin α, utilizing antibodies that were derivatized onto agarose beads [33]. In addition, various proteoforms have been identified and quantified by validated MSIA approaches, such as apolipoprotein A-I, apolipoprotein C-III, insulin-like growth factor 1, and serum amyloid A [34,35,36,37].

In this study, we describe MSIA, specially tailored for detecting PTH proteoforms, and assess additional microheterogeneity in PTH related to vitamin D deficiency among patients with diabetes mellitus.

2. Materials and Methods

2.1. Materials and Chemicals

The mouse anti-parathyroid hormone (PTH) antibody, clone 3H9 (Cat. No MA1-83384), was obtained from Thermofisher Scientific (Waltham, MA, USA). The 20X modified Dulbecco’s Phosphate buffered saline (PBS) buffer (Cat. No. 28344) was obtained from Thermofisher Scientific, 20X modified Dulbecco’s Phosphate buffered saline Tween-20 (PBST) buffer (Cat. No. 28346) was obtained from Thermofisher Scientific, MSIA D.A.R.T Protein A/G 96 tips (Cat. No. 991PRT15) (Thermo Scientific, Waltham, MA, USA), and Finnipipette Novus Multichannel Electronic Pipette and stand (Thermo scientific). Acetonitrile (ACN), methanol (MeOH), formic acid (FA) dithiothreitol (DTT), iodoacetamide (IAA), and ammonium bicarbonate (ABC) were purchased from Sigma-Aldrich (St.

Louis, MO, USA). RapiGest SF MS detergent was purchased from Waters Corporation (Milford, MA, USA). Both labeled (13C6, 15N2 labeled Lys and 13C6, 15N4 labeled Arg) and unlabeled peptides were synthesized by Biomatik Corporation (Kitchener, ON, Canada) with a minimum purity of 95%, aliquoted in 5 mg vials as dried pellets.

2.2. Subjects and Blood Samples

2.2.1. Ethical Approval and Participant Recruitment

All study procedures were followed as per ethical standards of the Declaration of Helsinki and the Universal International Conference on Harmonization-Good Clinical Practice (ICH-GCP) guidelines laid down for human participants. Samples were collected from the participants after obtaining the necessary approval from the Institutional Review Board College of Medicine, King Saud University Hospital (No E-16-1752) and after obtaining written informed consent.

2.2.2. Participant Recruitment and Sample Collection

We recruited forty patients with T2DM whose primary physician followed the King Saud University Medical City outpatient clinics. All patients had T2DM and no associated comorbidities. Samples were collected after a 10 h fast in EDTA tubes (Vacutainer, BD Biosciences, San Jose, CA, USA) by venipuncture. After centrifugation (15 min, 3000× g), plasma was separated, divided into several aliquots, and stored at −80 °C for further analysis. Routine laboratory investigations and estimations for 25 (OH) Vit D levels were carried out at the central biochemistry lab at KKUH.

Patients with T2DM were assessed for their Vit D levels and grouped according to their vitamin D status. Patients with Vit D more than 75 nmol/L were considered as T2DM with normal vitamin D (DN, n = 20), and those with VitD levels less than 50 nmol/L (DD, n = 20) were considered as T2DM with deficient VitD.

2.3. Signature Peptide Selection

The protein sequence of the human parathyroid hormone (PTH) from the species homo sapiens, identified by the accession number P01270, was acquired from the protein database of the National Center for Biotechnology Information (NCBI). To generate potential signature peptides, trypsin mediated in silico digestion was performed using the PeptideMass tool available on the Expasy bioinformatics resource portal [38]. The peptides were subsequently analyzed using the Basic Local Alignment Search Tool (BLAST) to compare them with other protein sequences in the NCBI database and verify their distinctiveness.

Selecting signature peptides involved a multi-step process. First, each signature peptide length range was between 5 and 25 amino acids for the best performance in experiments. Second, water solubility assessments were performed using Innovagen’s peptide calculator (https://pepcalc.com/). Thirdly, the ProtParam tool (http://web.expasy.org/protparam/, accessed on 1 June 2023) was used to monitor peptide stability. Fourthly, the SIM alignment tool was utilized to confirm that all chosen peptides belonged exclusively to PTH and did not match with any other proteins present in the sample.

Finally, posttranslational modifications (PTMs), including methylation, glycosylation, and phosphorylation, were verified using the UniProt and Phospho.ELM databases to ensure accuracy when measuring target proteins. Six distinct peptides, 32SVSEIQLMHNLGK44 (PTH-G1), 38LMHNLGK44 (PTH-G2), 45HLNSMER51 (PTH-G3), and 60DQVHNFVALGAPLAPR75 (PTH-G4), 65FVALGAPLAPR75 (PTH-G5), and 104ADVNVLTK111 (PTH-G6), were synthetically produced for the preparation of calibration curves. These peptides were produced in regular and stable-isotope-labeled forms, serving as internal standards (ISs). The materials, whose purity was greater than 95% as determined by high-performance liquid chromatography (HPLC), were subjected to peptide sequence identification.

This analysis focused specifically on determining the location of the labeling using high-resolution mass spectrometry (HRMS). The supplier certifies the quality of the standard materials, providing HPLC chromatograms and MS spectra for each standard material.

2.4. MRM Transition Development

2.4.1. Stock and Working Solution Preparation

For each labeled and unlabeled peptide, a 1.0 mg/mL stock solution in H2O was prepared. To tune the mass spectrometric conditions and optimize the chromatography, a 10.0 µg/mL working solution for each peptide was diluted in mobile phase A:B (0.1% FA in H2O:0.1% FA in 50% (v/v) ACN:MeOH).

2.4.2. LC-MS/MS Analysis

As previously described in our prior study [39], a 10.0 ug/mL working solution of each labeled and unlabeled peptide was introduced into an LC-MS system (Waters Acquity UPLC coupled with XEVO TQ-MS (Waters Corporation, Milford, MA, USA)), using positive-ionization electrospray (+ESI) at a 0.3 mL/min flow rate. Chromatographic separation occurred via ultra-high-pressure liquid chromatography UHPLC BEH C18 columns (1.7 μm, 2.1 × 100 mm). The chromatographic separation was performed using a gradient elution profile. The flow rate was set to 0.3 mL/min throughout the run.

The initial composition of the mobile phase was 90% solvent A (0.1% formic acid in H2O) and 10% solvent B (0.1% FA in 50% (v/v) ACN:MeOH). After 1 min, a linear gradient was applied over 10 min, shifting the composition to 10% solvent A and 90% solvent B. Afterward, the composition returned to the initial conditions (90% solvent A and 10% solvent B) within 1 min. The mobile phase remained at this composition for the final 3 min, making the total run time 15.

The injection volume was set at 10 µL. Modifications were made to the general mass spectrometry (MS) parameters for LC-MS/MS. The ion source desolvation temperature was maintained at 450 °C. The flow rates for the ion source desolvation and cone gasses were set at min900 L/h and 50 L/h, respectively. The MS capillary and cone voltages were also set at 2 kV and 40 V, respectively.

2.5. Preparation of Plasma Sample and Enrichment Using MSIA DARTs

The patient’s samples were taken and prepared according to the Thermo Scientific protocol using protein A/G MSIA Disposable Automation Research Tips (DARTs) to obtain the proteins of interest. The Novus i multichannel pipette was loaded with protein A/G MSIA™-Tips, and repeated cycles of aspiration and dispersion were carried out, as outlined in Table 1, for the immunopurification of the target protein. Briefly, the plasma samples were diluted ten times with PBST, and then the 15 μL from this was mixed with 135 μL of PBS (100×) and added into the column.

The tips were conditioned with PBS before binding 100 μL (0.05 mg/mL) of the mouse anti-PTH polyclonal antibody, clone 3H9 (100× plasma) that identifies the intact PTH peptide at the epitopes 1-34 and 1-84 (Cat-MA1-833384, Thermofisher, Waltham, MA, USA) to the protein’s A/G immobilized on the monolithic adsorbent surface (Figure 2). The target analytes (natural PTH proteoforms) were extracted from plasma by forming an antibody–antigen complex. Unbound antibody residues were removed with PBS and water after four consecutive washing steps.

The natural PTH proteoforms from the samples were then eluted into tubes using an elution buffer (40% acetonitrile and 0.4% TFA in distilled water) (Table 1). They were dried using a speed vacuum centrifuge.

2.5.1. In-Solution Tryptic Digestion

The tryptic digestion protocol was carried out by initially dissolving the proteins in 40 μL ammonium bicarbonate (50 mM) followed by incubation in the presence of dithiothreitol (DTT) (Sigma, St. Louis, MO, USA) (10 mM) at 56 °C for 1 h to reduce the disulfide bonds. Protein samples were next alkylated with iodoacetamide (IAA) (Sigma, St. Louis, MO, USA) (20 mM) at room temperature in the dark for another hour and were then digested using trypsin (Promega, Madison, WI, USA) in a 1:50 trypsin-to-protein ratio and incubated at 37 °C overnight.

Lastly, 7 µL of 10% formic acid was added to stop the reaction.

2.5.2. Solid-Phase Extraction (SPE)

Solid-phase extraction (SPE) was used to purify and concentrate the tryptic peptides following our standard protocol [40]. The Oasis HLB 1 cc 30 mg cartridge (Waters Oasis PRiME, Milford, MA, USA) was first conditioned with 100% methanol and then dH2O to wet the sorbent. Before running the samples through the sorbent, they were mixed with labeled peptides and diluted using a loading buffer (0.1% FA in dH2O). Unwanted substances were washed with dH2O twice.

Tryptic peptides were eluted using a solution comprising 0.1% formic acid (FA) in 50% acetonitrile (ACN). Following drying using the Savant(tm) DNA Concentrator SpeedVac (Thermo Scientific, USA), dried extracts were reconstitution in a 100 μL mixture consisting of 90% A (0.1% formic acid in H2O) before being analyzed using LC-MSMS.

2.6. LC-MS/MS Method Validation Protocol

The validation study followed the FDA guideline [41,42], and the samples were analyzed on LC-MSMS, as detailed in Section 2.4.2.

2.6.1. Linearity Verification

A mixture of unlabeled peptides with a concentration of 20 µg/mL was used to generate a calibration curve (0.1–1000 nM) and QC samples (1.5, 35, and 75 nM) prepared in an extracted matrix. This matrix was prepared from pooled serum samples, where the proteins were precipitated with an equal volume of acetone, and the pellets were resuspended with PBS buffer and digested tryptic. A constant amount (20 µL) of internal standard (20 µg/mL) was added to each sample and was run on the method detailed in Section 2.4.2.

Calibration curves for peptides were generated over three consecutive days and executed to evaluate linearity. The peptide signals, expressed as area ratios (standard area/internal standard area, IS), were plotted on the y-axis. In contrast, the nominal concentrations of the standard solutions were plotted on the x-axis. The linearity of the peptide signals was determined through regression analysis, measuring the correlation coefficient (R2) and the precision and accuracy at different calibration levels.

2.6.2. Limits of Detection

Three-day calibration curves provided an opportunity to establish limits of detection (LOD) and lower limits of quantification (LLOQ) for each peptide. LLOQ was defined as the lowest point on a calibration curve with signal at or exceeding 10× standard deviation of blank signal; S/N ratios were at least three or ten, depending on the concentration level for both concentrations; accuracy should range between 80 and 120% with daily variance less than 20%. Consequently, LLOD was adjusted so as to achieve an S/N ratio ≥3.

2.6.3. Inter- and Intraday Validation

Three quality control (QC) concentration levels—low (LQC), medium (MQC), and high (HQC)—were utilized to evaluate the precision and accuracy of the method. This involved the analysis of six samples from each QC level, both on the same day, to assess intraday precision (repeatability) and over three different days for interday precision (reproducibility) to determine repeatability. The signal variability in this study was evaluated using the percent relative standard deviation (RSD). For each quality control (QC) sample, the intraday precision was calculated by the following formula: [(standard deviation of measured QC concentrations on a given day x)/(mean of measured concentrations on day x)] × 100%.

Similarly, the interday precision was calculated as follows: [(standard deviation of measured QC concentrations over three days)/(mean of these measured concentrations over the three days)] × 100%. This study aimed to maintain a day-to-day variation below 20%. Intraday accuracy for each QC was calculated using the following formula: [(mean measured concentration)/(nominal concentration)] × 100%. The interday accuracy calculation followed the formula: [(mean measured concentration over three days)/(nominal QC concentration)] × 100%. For calibrators, accuracy within the 80–120% range for the limit of quantitation (LOQ) and 85–115% for other standard levels was considered acceptable.

2.6.4. Stability of Peptide

Three quality control (QC) samples (high, medium, and low) were extracted and stored at different temperatures, such as room temperature (RT), refrigeration (4 °C), and freezing (−20 °C), to test the storage stability of selected signature peptides. These conditions were compared with those of freshly prepared QC samples. The assessment of storage stability for each QC level involved determining the molecular stability. This was accomplished by multiplying the average area ratio of the analyzed sample with that of the fresh sample and multiplying the result by 100%.

2.6.5. Carryover

The highest standard was injected six times to assess the assay carryover, followed by injecting three blank samples. Carryover should not exceed 20% of LLOQ [43].

2.7. Data and Statistical Analysis

Statistical data analysis was performed using the Statistical Package for Social Sciences (SPSS) version 26 (SPSS Inc., Armonk, NY, USA) for the clinical variables between the two groups, and a p-value of less than 0.05 was considered statistically significant.

The LC-MS/MS MassLynx software, version 4.1 (Waters Corporation, Milford, MA, USA), was used to acquire, process, and visualize the data. The data for quantitative signals were displayed as mean values and SD. The protein levels of PTH G1-6 in patients with T2DM associated with vitamin D deficiency were compared to those in a group with normal vitamin D levels LC-MS/MS. Statistical analysis was performed using GraphPad Prism 6.01 (La Jolla, CA, USA), and p-values of less than 0.05 were considered significant.

3. Results and Discussion

3.1. Basic and Biochemical Characteristics

The basic characteristics and results of the biochemical parameters of the patients are described in Table 2. All the patients in the study had T2DM with either normal vitamin D levels or vitamin D deficiency. The mean age of patients with vitamin D deficiency was 45.3 ± 10.6, while those with normal vitamin D levels were 50.3 ± 13.2. There was no significant difference in the ages between the two groups and other biochemical parameters. A significant difference was noted only in the vitamin D levels between the groups (p < 0.01).

3.2. Signature Peptide Selection and LC-MS/MS Method Development

The protein sequences and isoforms of PTH (UniProt ID: P01270) were obtained from the human UniProt-FASTA database. Following the performance of in silico tryptic digestion on the PTH using PeptideMass, we could select signature peptides, which we confirmed with Skyline Software (version 19.1, Washington, DC, USA). The PTH’s signature peptides were chosen according to well-established criteria in the Methods section [39].

Table S1 details the characteristics of PTH-specific signature peptides selected for absolute quantification purposes, with light and heavy signature peptides acting as standards and internal standards (ISs). Calibration curves were constructed to measure signals using standard reference materials; furthermore, heavy isotopically labeled peptides have identical amino acid sequences and physical/chemical properties as the light peptides to maintain consistent ionization efficiency between unknown samples and calibration curves [44].

In this study, an internal standard (IS) version of each peptide was utilized, co-eluting at a similar retention time [45]. This approach corrected various analytical discrepancies, including differences in ionization efficiency, suppression, and the normalization of the signal. Thus, it helped determine concentrations using a calibration curve, where the response is based on the area ratio of the signature peptides to their internal standard [46].

3.3. Validation of LC-MS/MS Method

The method validation was performed in accordance with the guidelines set by the FDA [41,42].

3.3.1. Curve Linearity

A calibration curve is used to set the quantification range and linearity of measurements for each of the chosen PTH signal peptides that correspond to each PTH variant (aa32–44, aa38–44, aa45–51, aa60–75, aa65–75, and aa104–111).

Figure 3A,B show the extracted ion chromatograms of the PTH signature peptides (1 to 6), along with their labeled internal standards. The calibration curves for PTH variants exhibited excellent linearity over the range of 2.0 to 1000 nM with good linearity (r2 = 0.9999, 0.9982, 0.9990, 0.9999, 0.9999, and 0.9999, respectively).

3.3.2. Specificity and Sensitivity

Table S2 summarizes the findings of the method’s sensitivity evaluation, which was conducted according to the procedures outlined in the Methods Section 2.

PTH signature peptides were assessed over three days with an LLOQ of 2.0 nM, which was confirmed through triplicate measurement over multiple trips in triplicate, along with method linearity analysis that yielded coefficients of determination (R2) values between 0.9999, 0.9982, 0.9990, 0.9999, 0.9999 and 0.9999.

The absence of interferences with identical MRM transition and retention times characterizes specificity. The method’s specificity was assessed using LC-MS/MS. Furthermore, the blank sample from the carryover experiment described in the Methods section did not show any significant signal, amounting to less than 20% of the LLOQ.

3.3.3. Inter- and Intraday Precision

Accuracy and precision were measured for PTH variants by analyzing six replicates of LQC, MQC, and HQC samples (25 nM, 150 nM, and 750 nM, respectively) on the same day (intraday) and three other days (interday) to meet the acceptance limits set by ICH; interday variability for selected signature peptides ranged between 15 and 17% while accuracy ranged between 80 and 120% among the quality controls (Table S3) [31]. Intraday accuracy ranged between 95.69 and 104.07%, with precision levels below 15 (Table S4).

3.3.4. Peptide Stability Study

Three QC samples were used at three different concentrations (1.5, 35.0, and 75.0 nM) to evaluate the stability of the PTH signature peptides for the six variants. A stability assessment was conducted under various storage circumstances, including 24 h at room temperature, one week at 4 °C, two weeks at −20 °C, and one month at −20 °C. The stability of the selected signature peptides varied between 76.7% and 113.1% (Table S5).

3.4. Evaluation of Clinical Samples

PTH variant concentrations were measured using their corresponding signature peptides (PTH-G-1-G-5). There was a significant increase in PTH-G-2 (aa38–44), PTH-G-3 (aa45–51), and PTH-G-5 (aa65–75) among the patients with T2DM associated with vitamin D deficiency compared to the normal vitamin D group (p < 0.0001) (Figure 4).

The diagnostic values of PTH-G-2, PTH-G-3, and PTH-G-5 were assessed using receiver-operating characteristic (ROC) curves, as shown in Figure 5. The ROC curve plots the sensitivity (true positive rate) on the y-axis and the specificity (false positive rate) on the x-axis. The top left corner of the diagram represents the “ideal” position, characterized by zero false positives and one real positive. An ideal test has a maximum area under the receiver operating characteristic (ROC) curve (AUC) of one.

The area under the curve (AUC) values for PTH-G-2, PTH-G-3, and PTH-G-5 in individuals with T2DM and vitamin D deficiency, as well as those with T2DM and normal vitamin D levels, were 0.9950 (95% confidence interval [CI], p < 0.0001), 0.9375 (95% CI, p < 0.0001), and 1.000 (95% CI, p < 0.0001), respectively. Thus, PTH-G-2, PTH-G-3, and PTH-G-5 showed superior diagnostic and analytical capabilities in distinguishing between individuals with T2DM and vitamin D deficiency and those with T2DM and normal vitamin D levels.

The expression ratios for the peptides between people with diabetes with vitamin D deficiency (DD) and with normal (DN) levels ranged from 0.91 for ADVNVLTK (aa104–111) to 26.09 for FVALGAPLAPR (aa65–75) (Table S1).

Many clinical approaches use immobilized antibodies to quantify biomarkers, which are then detected by another antibody tagged with a fluorophore, radioisotope, or reporter enzyme. The capacity of antibodies to distinguish between different biomarker polymorphic variants and truncated proteoforms in a single analysis limits these approaches. This study reports the first use of MSIA to accurately identify and quantify PTH fragments between patients with T2DM and those with vitamin D deficiency and with normal vitamin D levels, and this method was successfully validated.

Vitamin D deficiency is a risk factor for developing and worsening T2DM [47]. Lowering vitamin D levels, in turn, affects the levels of PTH and can lead to secondary hyperparathyroidism. This effect of alteration in PTH is not reflected in the conventional assays for PTH, which do not consider the presence of other PTH peptides that are biologically active. In this regard, our study shows the ability of different PTH fragments, including PTH-G-2 (aa38–44), PTH-G-3 (aa45–51), and PTH-G-5 (aa65–75), to discriminate between T2DM with vitamin D deficiency and T2DM patients with normal vitamin D levels.

Moreover, vitamin D supplementation improves calcium absorption and reduces the stimulus for PTH secretion; this may alter the balance of PTH proteoforms. Specifically, with less demand for calcium regulation, there might be a reduction in the overall secretion of PTH, which could lead to a decrease in the levels of certain PTH fragments or changes in the relative proportions of these proteoforms. However, further studies are required to establish a definitive link between vitamin D supplementation and PTH proteoform distribution.

Despite MSIA’s power to distinguish between truncated proteoforms, this method has some limitations, such as the availability of high-quality antibodies, experimental design, and the absence of signals in mass spectra [48].

4. Conclusions

Utilizing this technique may provide significant benefits to clinical research laboratories, particularly in methods requiring the monitoring of numerous PTH variants or when analyzing samples that consist of a complex mixture of PTH-derived peptides and components resulting from the digestion of compounds within the sample matrix.

In addition, our findings suggest that PTH proteoforms have significant potential as biomarkers for monitoring calcium homeostasis, particularly in patients with T2DM who also experience vitamin D deficiency. Future research should focus on validating these proteoforms in larger cohorts to establish their clinical utility and potential for improving patient outcomes.

Disclaimer/Publisher’s Note: The statements, opinions and data contained in all publications are solely those of the individual author(s) and contributor(s) and not of MDPI and/or the editor(s). MDPI and/or the editor(s) disclaim responsibility for any injury to people or property resulting from any ideas, methods, instructions or products referred to in the content.

Supplementary Materials

The following are available online at https://www.mdpi.com/article/10.3390/proteomes12040030/s1. Table S1: List of PTH signature peptides and their internal standard details; Table S2: Linearity and sensitivity summary over three days.; Table S3: Interday validation summary; Table S4: Intra-day validation summary. SD: Standard deviation. Table S5: Summary of PTH peptides’ stability at different storage conditions for a determined period.

Supplement file at the original source — open the original paper. This file is not included in this text import.

Author Contributions

A.A.A., A.M. and H.B. conceived and designed the study. A.A.A. and A.M. were involved in patient recruitment. H.B., A.M., M.A.M. and A.M.A.R. performed the proteomic lab work. A.M., H.B., A.A.A., A.M.A.R. and R.M.N. conducted the data analysis and wrote the manuscript. All authors have read and agreed to the published version of the manuscript.

Institutional Review Board Statement

The study procedures and protocols were reviewed and approved by the Institutional Review Board at the College of Medicine, King Saud University. Written, informed consent was obtained from all the participants (IRB number: No E-16-1752).

Informed Consent Statement

Informed consent was obtained from all participants involved in the study.

Data Availability Statement

The datasets used and/or analyzed during the current study are available from the corresponding author on reasonable request.

Conflicts of Interest

The authors declare no conflicts of interest.

Abbreviations

PTHParathyroid hormone CLIAClinical Laboratory Improvement Amendments MSIAMass spectrometric immunoassay T2DMType 2 diabetes mellitus VDRsVitamin D receptors MeOHMethanol FAFormic acid ABCAmmonium bicarbonate ICH-GCPInternational Conference on Harmonization-Good Clinical Practice DNDiabetic patients with normal vitamin D DDDiabetic patients with deficient vitamin D ISInternal standard D.A.R.T.Disposable Automation Research Tips RSDRelative standard deviation QCQuality control

References

1. Chiu K.C. Chuang L.M. Lee N.P. Ryu J.M. McGullam J.L. Tsai G.P. Saad M.F. Insulin sensitivity is inversely correlated with plasma intact parathyroid hormone level Metabolism 2000 49 1501 1505 10.1053/meta.2000.17708 11092519
2. Chiu K.C. Chu A. Go V.L. Saad M.F. Hypovitaminosis D is associated with insulin resistance and beta cell dysfunction Am. J. Clin. Nutr. 2004 79 820 825 10.1093/ajcn/79.5.820 15113720
3. Sass M.R. Wewer Albrechtsen N.J. Pedersen J. Hare K.J. Borbye-Lorenzen N. Kiss K. Vilsboll T. Knop F.K. Poulsen S.S. Jorgensen N.R. Secretion of parathyroid hormone may be coupled to insulin secretion in humans Endocr. Connect. 2020 9 747 754 10.1530/EC-20-0092 32698134 PMC7424341
4. Vijay G.S. Ghonge S. Vajjala S.M. Palal D. Prevalence of Vitamin D Deficiency in Type 2 Diabetes Mellitus Patients: A Cross-Sectional Study Cureus 2023 15 e38952 10.7759/cureus.38952 37313077 PMC10258395
5. Klahold E. Penna-Martinez M. Bruns F. Seidl C. Wicker S. Badenhoop K. Vitamin D in type 2 diabetes: Genetic susceptibility and the response to supplementation Horm. Metab. Res. 2020 52 492 499 32542627 10.1055/a-1157-0026 PMC7746514
6. Talaei A. Mohamadi M. Adgi Z. The effect of vitamin D on insulin resistance in patients with type 2 diabetes Diabetol. Metab. Syndr. 2013 5 8 10.1186/1758-5996-5-8 23443033 PMC3586569
7. Holick M.F. Binkley N.C. Bischoff-Ferrari H.A. Gordon C.M. Hanley D.A. Heaney R.P. Murad M.H. Weaver C.M. Endocrine S. Evaluation, treatment, and prevention of vitamin D deficiency: An Endocrine Society clinical practice guideline J. Clin. Endocrinol. Metab. 2011 96 1911 1930 10.1210/jc.2011-0385 21646368
8. Jacquillet G. Unwin R.J. Physiological regulation of phosphate by vitamin D, parathyroid hormone (PTH) and phosphate (Pi) Pflügers Arch.-Eur. J. Physiol. 2019 471 83 98 10.1007/s00424-018-2231-z 30393837 PMC6326012
9. Lips P. Vitamin D deficiency and secondary hyperparathyroidism in the elderly: Consequences for bone loss and fractures and therapeutic implications Endocr. Rev. 2001 22 477 501 10.1210/edrv.22.4.0437 11493580
10. Hussain A. Latiwesh O.B. Ali A. Tabrez E. Mehra L. Nwachukwu F. Parathyroid Gland Response to Vitamin D Deficiency in Type 2 Diabetes Mellitus: An Observational Study Cureus 2018 10 e3656 10.7759/cureus.3656 30723655 PMC6351110
11. Vilardaga J.-P. Friedman P.A. Chapter 30—Molecular Biology of Parathyroid Hormone Textbook of Nephro-Endocrinology 2nd ed. Singh A.K. Williams G.H. Academic PressCambridge, MA, USA2018 523 537 10.1016/B978-0-12-803247-3.00031-3
12. Smith L.M. Kelleher N.L. Proteoform: A single term describing protein complexity Nat. Methods 2013 10 186 187 10.1038/nmeth.2369 23443629 PMC4114032
13. Aebersold R. Agar J.N. Amster I.J. Baker M.S. Bertozzi C.R. Boja E.S. Costello C.E. Cravatt B.F. Fenselau C. Garcia B.A. How many human proteoforms are there? Nat. Chem. Biol. 2018 14 206 214 10.1038/nchembio.2576 29443976 PMC5837046
14. D’Amour P. Brossard J.-H. Rousseau L. Nguyen-Yamamoto L. Nassif E. Lazure C. Gauthier D. Lavigne J.R. Zahradnik R.J. Structure of non-(1-84) PTH fragments secreted by parathyroid glands in primary and secondary hyperparathyroidism Kidney Int. 2005 68 998 1007 10.1111/j.1523-1755.2005.00493.x 16105030
15. Usatii M. Rousseau L. Demers C. Petit J.L. Brossard J.H. Gascon-Barre M. Lavigne J.R. Zahradnik R.J. Nemeth E.F. D’Amour P. Parathyroid hormone fragments inhibit active hormone and hypocalcemia-induced 1,25(OH)2D synthesis Kidney Int. 2007 72 1330 1335 10.1038/sj.ki.5002532 17805236
16. Evenepoel P. Bover J. Torres P.U. Parathyroid hormone metabolism and signaling in health and chronic kidney disease Kidney Int. 2016 90 1184 1190 10.1016/j.kint.2016.06.041 27653840
17. Geng S. Kuang Z. Peissig P. Page D. Maursetter L. Hansen K. Parathyroid hormone independently predicts fracture, vascular events, and death in patients with stage 3 and 4 chronic kidney disease Osteoporos. Int. 2019 30 2019 2025 10.1007/s00198-019-05033-3 31190122
18. Fraser W.D. Walsh C.A. Birch M.A. Durham B. Dillon J.P. McCreavy D. Gallagher J.A. Parathyroid hormone-related protein in the aetiology of fibrous dysplasia of bone in the McCune Albright syndrome Clin. Endocrinol. 2000 53 621 628 10.1046/j.1365-2265.2000.01112.x 11106924
19. Chew C.K. Clarke B.L. Abaloparatide: Recombinant human PTHrP (1–34) anabolic therapy for osteoporosis Maturitas 2017 97 53 60 10.1016/j.maturitas.2016.12.003 28159062
20. Smit M.A. van Kinschot C.M.J. van der Linden J. van Noord C. Kos S. Clinical Guidelines and PTH Measurement: Does Assay Generation Matter? Endocr. Rev. 2019 40 1468 1480 10.1210/er.2018-00220 31081903
21. Borges C.R. Rehder D.S. Jarvis J.W. Schaab M.R. Oran P.E. Nelson R.W. Full-length characterization of proteins in human populations Clin. Chem. 2010 56 202 211 10.1373/clinchem.2009.134858 19926773
22. Ljungdahl N. Haarhaus M. Linder C. Magnusson P. Comparison of 3 third-generation assays for bio-intact parathyroid hormone Clin. Chem. 2006 52 903 904 10.1373/clinchem.2005.065821 16638963
23. Boudou P. Ibrahim F. Cormier C. Sarfati E. Souberbielle J.C. Unexpected serum parathyroid hormone profiles in some patients with primary hyperparathyroidism Clin. Chem. 2006 52 757 760 10.1373/clinchem.2005.060962 16497941
24. Sturgeon C.M. Sprague S. Almond A. Cavalier E. Fraser W.D. Algeciras-Schimnich A. Singh R. Souberbielle J.C. Vesper H.W. PTH I.W.G.f. Perspective and priorities for improvement of parathyroid hormone (PTH) measurement—A view from the IFCC Working Group for PTH Clin. Chim. Acta 2017 467 42 47 10.1016/j.cca.2016.10.016 27746210 PMC5695551
25. Cavalier E. Farre-Segura J. Lukas P. Gendebien A.S. Peeters S. Massonnet P. Le Goff C. Bouquegneau A. Souberbielle J.C. Delatour V. Unveiling a new era with liquid chromatography coupled with mass spectrometry to enhance parathyroid hormone measurement in patients with chronic kidney disease Kidney Int. 2024 105 338 346 10.1016/j.kint.2023.09.033 37918791
26. Kumar V. Barnidge D.R. Chen L.S. Twentyman J.M. Cradic K.W. Grebe S.K. Singh R.J. Quantification of serum 1-84 parathyroid hormone in patients with hyperparathyroidism by immunocapture in situ digestion liquid chromatography-tandem mass spectrometry Clin. Chem. 2010 56 306 313 10.1373/clinchem.2009.134643 20007860
27. Lopez M.F. Rezai T. Sarracino D.A. Prakash A. Krastins B. Athanas M. Singh R.J. Barnidge D.R. Oran P. Borges C. Selected reaction monitoring-mass spectrometric immunoassay responsive to parathyroid hormone and related variants Clin. Chem. 2010 56 281 290 10.1373/clinchem.2009.137323 20022981
28. Farre-Segura J. Le Goff C. Lukas P. Cobraiville G. Fillet M. Servais A.C. Delanaye P. Cavalier E. Validation of an LC-MS/MS Method Using Solid-Phase Extraction for the Quantification of 1-84 Parathyroid Hormone: Toward a Candidate Reference Measurement Procedure Clin. Chem. 2022 68 1399 1409 10.1093/clinchem/hvac135 36056745
29. Kritmetapak K. Losbanos L.A. Hines J.M. O’Grady K.L. Ulmer C.Z. Vesper H.W. Enders F.T. Singh R.J. Kumar R. Chemical Characterization and Quantification of Circulating Intact PTH and PTH Fragments by High-Resolution Mass Spectrometry in Chronic Renal Failure Clin. Chem. 2021 67 843 853 10.1093/clinchem/hvab013 33693557 PMC8167341
30. Ulmer C.Z. Kritmetapak K. Singh R.J. Vesper H.W. Kumar R. High-Resolution Mass Spectrometry for the Measurement of PTH and PTH Fragments: Insights into PTH Physiology and Bioactivity J. Am. Soc. Nephrol. 2022 33 1448 1458 10.1681/ASN.2022010036 35396262 PMC9342634
31. Liu M. Miao D. Qin S. Liu H. Bai Y. Mass tag-based mass spectrometric immunoassay and its bioanalysis applications TrAC Trends Anal. Chem. 2022 157 116745 10.1016/j.trac.2022.116745
32. Gao J. Meyer K. Borucki K. Ueland P.M. Multiplex immuno-MALDI-TOF MS for targeted quantification of protein biomarkers and their proteoforms related to inflammation and renal dysfunction Anal. Chem. 2018 90 3366 3373 10.1021/acs.analchem.7b04975 29420882
33. Nelson R.W. Krone J.R. Bieber A.L. Williams P. Mass spectrometric immunoassay Anal. Chem. 1995 67 1153 1158 10.1021/ac00103a003 15134097
34. Yassine H.N. Jackson A.M. Reaven P.D. Nedelkov D. Nelson R.W. Lau S.S. Borchers C.H. The application of multiple reaction monitoring to assess ApoA-I methionine oxidations in diabetes and cardiovascular disease Transl. Proteom. 2014 4 18 24 10.1016/j.trprot.2014.10.001 25705587 PMC4331021
35. Yassine H.N. Trenchevska O. Ramrakhiani A. Parekh A. Koska J. Walker R.W. Billheimer D. Reaven P.D. Yen F.T. Nelson R.W. The association of human apolipoprotein C-III sialylation proteoforms with plasma triglycerides PLoS ONE 2015 10 e0144138 10.1371/journal.pone.0144138 26633899 PMC4669142
36. Oran P.E. Trenchevska O. Nedelkov D. Borges C.R. Schaab M.R. Rehder D.S. Jarvis J.W. Sherma N.D. Shen L. Krastins B. Parallel workflow for high-throughput (>1,000 samples/day) quantitative analysis of human insulin-like growth factor 1 using mass spectrometric immunoassay PLoS ONE 2014 9 e92801 10.1371/journal.pone.0092801 24664114 PMC3963945
37. Yassine H.N. Trenchevska O. He H. Borges C.R. Nedelkov D. Mack W. Kono N. Koska J. Reaven P.D. Nelson R.W. Serum amyloid a truncations in type 2 diabetes mellitus PLoS ONE 2015 10 e0115320 10.1371/journal.pone.0115320 25607823 PMC4301920
38. Guideline I.H.T. Validation of analytical procedures: Text and methodology Q2 (R1) 2005 1 05
39. Nimer R.M. Sumaily K.M. Almuslat A. Abdel Jabar M. Sabi E.M. Al-Muhaizea M.A. Abdel Rahman A.M. Dystrophin Protein Quantification as a Duchenne Muscular Dystrophy Diagnostic Biomarker in Dried Blood Spots Using Multiple Reaction Monitoring Tandem Mass Spectrometry: A Preliminary Study Molecules 2022 27 3662 10.3390/molecules27123662 35744792 PMC9231037
40. Malkawi A.K. Nimer R.M. Almogren M. Masood A. Alarfaj A.S. Benabdelkamel H. Abdel Rahman A.M. Siaj M. Quantitative analysis of soluble costimulatory molecules as potential diagnostic biomarkers for rheumatoid arthritis using LC-MS/MS in MRM mode Clin. Chim. Acta 2023 548 117501 10.1016/j.cca.2023.117501 37516334
41. U.S. Food and Drug Administration Bioanalytical Method Validation Guidance for Industry US Department of Health and Human Services Food and Drug Administration Center for Drug Evaluation and Research and Center for Veterinary MedicineRockville, MD, USA2018
42. U.S. Food and Drug Administration Guidance for Industry. Q2B Validation of Analytical Procedures: Methodology. US Department of Health and Human Services U.S. Food and Drug Administration Center for Drug Evaluation and Research, Center for Biologics Evaluation and ResearchRockville, MD, USA1996
43. U.S. Food and Drug Administration M10 Bioanalytical Method Validation and Study Sample Analysis U.S. Food and Drug Administration Center for Drug Evaluation and Research, Center for Biologics Evaluation and ResearchRockville, MD, USA2022
44. Hopfgartner G. Lesur A. Varesio E. Analysis of biopharmaceutical proteins in biological matrices by LC-MS/MS II. LC-MS/MS analysis TrAC Trends Anal. Chem. 2013 48 52 61 10.1016/j.trac.2013.03.008
45. Sumaily K.M. Nimer R. Alzahrani M. Abdel Jabar M. Alodib A. Sabi E.M. Nizami I. Abdel Rahman A.M. CFTR protein quantification as a cystic fibrosis diagnostic biomarker in dried blood spots using multiple reaction monitoring tandem mass spectrometry J. Pharm. Biomed. Anal. 2022 216 114801 10.1016/j.jpba.2022.114801 35504217
46. Galal M.A. Jabar M.A. Zhra M. Rahman A.M.A. Aljada A. Absolute quantification of senescence mediators in cells using multiple reaction monitoring liquid chromatography-Tandem mass spectrometry Anal. Chim. Acta 2021 1184 339009 10.1016/j.aca.2021.339009 34625254
47. Afzal S. Bojesen S.E. Nordestgaard B.G. Low 25-hydroxyvitamin D and risk of type 2 diabetes: A prospective cohort study and metaanalysis Clin. Chem. 2013 59 381 391 10.1373/clinchem.2012.193003 23232064
48. Trenchevska O. Nelson R.W. Nedelkov D. Mass Spectrometric Immunoassays in Characterization of Clinically Significant Proteoforms Proteomes 2016 4 13 10.3390/proteomes4010013 28248223 PMC5217360
Figure 1

PTH variant map. (A) Truncated PTH variants identified previously. (B) Tryptic fragments were chosen for SRM- MSIA.

Figure image at the original source — open the original paper. This file is not included in this text import.
Figure 2

Experimental workflow for mass spectrometric immunoassay PTH. ****; p < 0.0001.

Figure image at the original source — open the original paper. This file is not included in this text import.
Figure 3

Representative extracted ion chromatography (C = 1000 nM) and calibration curves: (A) extracted ion chromatograms for the quantitative transitions for PTH-G-1 SP (486.03 > 187.06), PTH-G-2 SP (271.64 > 165.97), PTH-G-3 SP (296.31 > 435.2), PTH-G-4 SP (569.32 > 553.38), PTH-G-5 SP (556.63 > 247.14), PTH-G-6 SP (430.45 > 248.17), and their labeled internal standard transitions (488.84 > 187.07, 274.25 > 207.05, 299 > 445, 572 > 562.34, 561 > 247.13, 434 > 256.16, respectively); (B) calibration curves of PTH-G-1, PTH-G-2, PTH-G-3, PTH-G-4, PTH-G-5, and PTH-G-6.

Figure image at the original source — open the original paper. This file is not included in this text import.
Figure 4

Bar graph of PTH-G-1, PTH-G-2, PTH-G-3, PTH-G-4, PTH-G-5, and PTH-G-6 levels in the serum of patient samples who were diabetic or had vitamin D deficiency (DD), and normal levels (DN). ****, p < 0.0001, ns; nonsignificant.

Figure image at the original source — open the original paper. This file is not included in this text import.
Figure 5

The receiver-operating characteristic (ROC) curve of (A) PTH-G-2, (95% CI, 0.9818–1.000), (B) PTH-G-3, (95% CI, 0.8629–1.000), and (C) PTH-G-5 (95% CI, 1.000–1.000) serum levels of patient samples who were diabetic or had vitamin D deficiency (DD).

Figure image at the original source — open the original paper. This file is not included in this text import.
Table 1

Pipetting scheme for PTH purification using a Thermo Finnpipette™ Novus i Multichannel Electronic Pipette equipped with Protein A/G MSIA™-Tips.

1
Wash
2
Immobilization of Antibody
3
Wash
4
Antigen Capture
5
Wash
6
Wash
7
Wash
8
Wash
9
Elution
LiquidPBS100 μL (0.05 mg/mL) of the Mouse Anti Parathyroid Hormone (PTH) Antibody10 mM PBS150 μL of 100× Diluted Plasma in PBST10 mM PBS10 mM PBSLC/MS Grade WaterLC/MS Grade Water40% Acetonitrile and 0.4% TFA LC/MS Grade Water
Asp/Disp cycles10×250×10×100×10×10×10×10×10×
Cycle volume (μL)150801501001501501501507
Total well volume (μL)20010020010020020020020010
Table 2

Biochemical parameters of patients with T2DM and without vitamin D deficiency.

ParameterVitamin D Deficiency (n = 20)Normal Vitamin D (n = 20)p-Value
Male/Female (%)60/4070/30NA
Age (years) 45.3 ± 10.650.3 ± 13.20.12
Glucose (mmol/L)6.3 ± 0.87.2 ± 0.50.09
Urea (mmol/L)4.3 ± 0.94.6 ± 0.80.26
Creatinine (umol/L)71.1 ± 12.775.3 ± 12.00.074
Sodium (mmol/L)132.6 ± 5.1136.3 ± 5.90.13
Potassium (mmol/L)4.2 ± 0.24.3 ± 0.40.40
Aspartate transaminase (IU/L)44.8 ± 9.141.8 ± 4.50.38
Alanine transaminase (IU/L)19.5 ± 518.8 ± 2.00.4
Alkaline phosphatase (IU/L)97.6 ± 13.793.2 ± 28.90.3
Total cholesterol (mmol/L)4.6 ± 1.04.9 ± 0.80.10
HDL cholesterol (mmol/L)1.2 ± 0.21.4 ± 0.20.2
LDL cholesterol (mmol/L)2.8 ± 0.93.1 ± 0.70.09
Triglycerides (mmol/L)1.8 ± 0.62.5 ± 0.20.07
vitamin D (nmol/L)27.7 ± 9.397.5 ± 22.9<0.01 *

Values are presented as mean ± SD. * p  < 0.05.

Publication and source details

Original title: Multiple Reaction Monitoring–Mass Spectrometric Immunoassay Analysis of Parathyroid Hormone Fragments with Vitamin D Deficiency in Patients with Diabetes Mellitus

Hicham Benabdelkamel; Refat M. Nimer; Afshan Masood; Maha Al Mogren; Anas M. Abdel Rahman; Assim A. Alfadda

Proteomes · 2024

* Correspondence: aabdelrahman46@kfshrc.edu.sa (A.M.A.R.); aalfadda@ksu.edu.sa (A.A.A.)© 2024 by the authors.2024https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).National Plan for Science, Technology, and Innovation (MAARIFAH), King Abdulaziz City for Science and Technology, Saudi Arabia14-MED-543-02This project was funded by the National Plan for Science, Technology, and Innovation (MAARIFAH), King Abdulaziz City for Science and Technology, Saudi Arabia, (Project no. 14-MED-543-02).

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-11T03:30:45.183768+00:00

DOI: 10.3390/proteomes12040030 · PMC11503337