Primary relevance to vitamin D Vitamin D is a stated subject of this paper.
Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.
Why this paper is included
Supporting source evidence:
In vitamin D sufficiency, median PTH was 31.9 pg/mL [range (2.5th: 97.5th percentile) 17.9 to 58.6] compared with 35.5 pg/mL (17.0 to 60.4) for insufficiency, and 39.8 pg/mL (19.5 to 86.4) for deficiency.
Source: Abstract. View original paper
Relevance classification does not establish study quality, causation or editorial approval.
Study design Study design awaiting verification.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.
Meta-analysis unclear · Blinding unclear / not reported · Human research reported
How this paper was classified
Automatic source-based classification; awaiting editorial verification. This is not a quality score.
Volunteers were enrolled at three geographic sites across the USA (Century Clinical Research Inc., Daytona Beach, Florida, USA; NB Research, Indianapolis, Indiana, USA; Prism Research, LLC., St Paul, Minnesota, USA).
Source: Methods.
What the study types mean
- Systematic review
- Uses explicit methods to identify, assess and summarise research on a defined question.
- Scoping review
- Maps the extent and characteristics of research on a topic.
- Narrative review
- Discusses existing research; systematic-review methods have not been established by this classification.
- Review / evidence synthesis
- Reviews existing research; the exact review methods need further assessment.
- Randomised controlled trial
- Assigns participants or groups to comparison interventions by chance.
- Non-randomised intervention study
- Examines an intervention without random allocation.
- Cohort study
- Examines exposures and outcomes over time within a defined group.
- Case-control study
- Compares people with an outcome against people without it, examining exposures.
- Cross-sectional study
- Examines a population at a particular point in time.
- Observational study
- Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
- Case report
- Describes an individual case.
- Case series
- Describes a group of individual cases.
- Secondary analysis
- Analyses existing study data; this paper is not automatically another independent trial.
- Laboratory study
- Investigates biological processes in a laboratory setting.
- Qualitative study
- Examines experiences or meanings using qualitative methods.
- Genetic instrumental-variable study
- Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
- Study protocol
- Describes planned methods and is not evidence that the planned study has reported results.
- Multiple reported designs
- More than one design is explicitly reported; examine the supporting methods.
- Study design awaiting verification
- The available source does not establish a sufficiently clear study design.
Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.
Abstracts
Parathyroid hormone reference ranges in healthy individuals classified by vitamin D status
Study design awaiting verification · Journal of Endocrinological Investigation · 2019
Original publication title
Parathyroid hormone reference ranges in healthy individuals classified by vitamin D status
© The Author(s) 2019
Original publication · Publisher record · CC BY 4.0
Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.
At a glance
Abstract: What objectives does the paper state?
Parathyroid hormone (PTH) concentrations are routinely measured in the diagnosis and management of bone and kidney diseases, but reference ranges can be overestimated if determined in otherwise healthy individuals for whom vitamin D deficiency was not evaluated. We establish PTH reference ranges in apparently healthy, normocalcemic, normophosphatemic individuals categorized by 25-hydroxyvitamin D (25(OH)D) status using the Elecsys® PTH (cobas e 601) and Elecsys® Vitamin D total II electrochemiluminescence immunoassays (cobas e 411).
Source: PurposeAbstract: What methods does the paper describe?
This prospective, non-interventional study measured PTH in serum from 653 apparently healthy adults [56.7% female; 68.2% white/Caucasian; 28.6% African American; median age 44 years (range 21 to 83)] from three diverse geographic sites across the USA during summer and winter months. Subjects were classified by concomitant vitamin D sufficiency (≥ 30 ng/mL), insufficiency (> 20 to < 30 ng/mL) or deficiency (≤ 20 ng/mL).
Source: MethodsAbstract: Results
In vitamin D sufficiency, median PTH was 31.9 pg/mL [range (2.5th: 97.5th percentile) 17.9 to 58.6] compared with 35.5 pg/mL (17.0 to 60.4) for insufficiency, and 39.8 pg/mL (19.5 to 86.4) for deficiency. A significant inverse relationship was found between PTH and 25(OH)D (P < 0.001). After accounting for vitamin D, potential effects of race or season as covariates were relatively small or absent.
Source: ResultsAbstract: Conclusions
Upper reference limits (URL) for PTH in vitamin D sufficiency/insufficiency were similar and lower than current values. Clinically important PTH elevations were observed in vitamin D deficiency, where revised reference ranges with a higher URL may be appropriate. These data may help to distinguish vitamin D-related PTH elevations from other causes [e.g., primary (normocalcemic) or secondary hyperparathyroidism].
Source: ConclusionsAuthors’ abstract
Purpose
Parathyroid hormone (PTH) concentrations are routinely measured in the diagnosis and management of bone and kidney diseases, but reference ranges can be overestimated if determined in otherwise healthy individuals for whom vitamin D deficiency was not evaluated. We establish PTH reference ranges in apparently healthy, normocalcemic, normophosphatemic individuals categorized by 25-hydroxyvitamin D (25(OH)D) status using the Elecsys® PTH (cobas e 601) and Elecsys® Vitamin D total II electrochemiluminescence immunoassays (cobas e 411).
Methods
This prospective, non-interventional study measured PTH in serum from 653 apparently healthy adults [56.7% female; 68.2% white/Caucasian; 28.6% African American; median age 44 years (range 21 to 83)] from three diverse geographic sites across the USA during summer and winter months. Subjects were classified by concomitant vitamin D sufficiency (≥ 30 ng/mL), insufficiency (> 20 to < 30 ng/mL) or deficiency (≤ 20 ng/mL).
Results
In vitamin D sufficiency, median PTH was 31.9 pg/mL [range (2.5th: 97.5th percentile) 17.9 to 58.6] compared with 35.5 pg/mL (17.0 to 60.4) for insufficiency, and 39.8 pg/mL (19.5 to 86.4) for deficiency. A significant inverse relationship was found between PTH and 25(OH)D (P < 0.001). After accounting for vitamin D, potential effects of race or season as covariates were relatively small or absent.
Conclusions
Upper reference limits (URL) for PTH in vitamin D sufficiency/insufficiency were similar and lower than current values. Clinically important PTH elevations were observed in vitamin D deficiency, where revised reference ranges with a higher URL may be appropriate. These data may help to distinguish vitamin D-related PTH elevations from other causes [e.g., primary (normocalcemic) or secondary hyperparathyroidism].
Publication and source details
Original title: Parathyroid hormone reference ranges in healthy individuals classified by vitamin D status
N. Yalla; G. Bobba; G. Guo; A. Stankiewicz; R. Ostlund
Journal of Endocrinological Investigation · 2019
© The Author(s) 2019https://creativecommons.org/licenses/by/4.0/Open AccessThis article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.Roche Diagnostics International LtdRepository JATS snapshot; version as supplied
Source retrieved: 2026-11-11T18:54:50.722133+00:00
DOI: 10.1007/s40618-019-01075-w · PMC6790182