Vitamin D3 for Life. Live Enlightened.

Research libraryVitamin D3 For Life
Study design and methods

Primary relevance to vitamin D Vitamin D is a stated subject of this paper.

Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.

Why this paper is included

Supporting source evidence:

The When, What & How of Measuring Vitamin D Metabolism in Clinical Medicine

Source: Article title. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Review / evidence synthesis.

Review / evidence synthesis

Reviews existing research; the exact review methods need further assessment.

Meta-analysis unclear · Blinding not applicable to this review · Research setting awaiting verification

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

Publisher article type: review-article

Source: Publisher publication metadata.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Full studies

The When, What & How of Measuring Vitamin D Metabolism in Clinical Medicine

Review / evidence synthesis · Nutrients · 2018

Original publication title

The When, What & How of Measuring Vitamin D Metabolism in Clinical Medicine

Niek F. Dirks; Mariëtte T. Ackermans; Paul Lips; Renate T. de Jongh; Marc G. Vervloet; Robert de Jonge; Annemieke C. Heijboer

© 2018 by the authors.

Original publication · Publisher record · CC BY 4.0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

At a glance

Study background

What background does the paper provide?

With the ever-growing family of measurable vitamin D metabolites and techniques to assess them, comes a predicament. How does a clinician decide when measurement of vitamin D metabolism benefits the diagnostic process? What metabolic product of vitamin D provides the necessary answers, and how best to measure it? The goal of this review is to clarify the value of measuring vitamin D metabolites in diagnostics and to illustrate which metabolite is to be measured under which circumstances, and why. Additionally, the choice of method is discussed, as this is an important aspect of appropriate vitamin D metabolism measurement.

The paper is structured as follows. Section 2 is dedicated to the metabolism of vitamin D. Knowledge of the processes and the stimulatory and inhibitory factors involved in this ingenious metabolic pathway is a prerequisite for understanding the benefits and relevance of measuring the different metabolites. Section 3 focuses on the when and what, situations where the major vitamin D metabolites may contribute to a fitting diagnosis or monitoring of a disease. Section 4, on the how, explores the different methods a present-day laboratory may offer to measure the desired metabolites.

As not all available methods are suitable for every situation, knowing the flaws and pitfalls of the various measurement procedures is important to prevent a misdiagnosis or missed diagnosis. In the end, everyone benefits from a faster, more reliable and more economical way to achieve proper diagnosis by knowing when to measure, what to measure and how to measure vitamin D metabolites in a clinical setting.

Source: 1. Introduction Source: 1. Introduction

Vitamin D Metabolism

Vitamin D metabolism (Figure 1) is a complex and ingenious process proceeding inside multiple organs within the human body to maintain calcium homeostasis and control bone metabolism. It all starts with 7-dehydrocholesterol which, when exposed to UVB light in the human skin, transforms into vitamin D3 through intermediate isomer pre-vitamin D3. Alternatively, a small portion of vitamin D3 may be directly ingested by the consumption of animal products. Another isomeric form, vitamin D2, is not synthesised by our own body, but may be extracted from some plants and fungi.

Both forms behave similarly and undergo the same metabolic process. Both activated forms also bind to the vitamin D receptor (VDR), although the active metabolite of vitamin D3 has proven to be more potent [1]. From here, if there is no need for the distinction between the two isomers, vitamin D and associated metabolic products refer to both species. Cutaneously synthesised or ingested vitamin D is subsequently transported to the liver, usually bound to a vitamin D binding protein (DBP), where hydroxylation on the 25-position by hepatic CYP2R1 (25-hydroxylase) yields 25-hydroxyvitamin D (25(OH)D).

The hormonally active 1,25-dihydroxyvitamin D (1,25(OH)2D) is produced in the proximal renal tubule by the mitochondrial CYP27B1 enzyme (1α-hydroxylase), after a second hydroxylation at the 1-position. To retain 1,25(OH)2D concentrations within the strict boundaries required for appropriate calcium homeostasis and bone metabolism, both 1,25(OH)2D and 25(OH)D may undergo further hydroxylation by renal CYP24A1 (24-hydroxylase), leading, respectively, to 1,24,25-trihydroxyvitamin D and 24(R),25-dihydroxyvitamin D (24,25(OH)2D), with negligible affinity for the VDR. In addition, all of the aforementioned metabolites are subject to C-3 epimerisation resulting in products with lower VDR and DBP binding affinities and reduced activity compared to their unepimerised counterparts [2].

This metabolic process is tightly controlled by a number of regulators. Parathyroid hormone (PTH) stimulates production of 1,25(OH)2D by upregulating CYP27B1 gene expression, while inhibiting expression of CYP24A1. Fibroblast growth factor 23 (FGF23) inhibits CYP27B1 and stimulates CYP24A1, thus preventing the production of 1,25(OH)2D and stimulating its catabolism [3]. Calcium decreases CYP27B1 activity directly and through inhibition of the action as exerted by PTH, all leading to lower 1,25(OH)2D concentrations. Lack of phosphate (hypophosphatemia) results in the opposite, by stimulating CYP27B1 and inhibiting CYP24A1 expression. 1,25(OH)2D itself supresses CYP27B1 and stimulates CYP24A1, thereby promoting its own degradation when excessively present.

Apart from the well-documented renal conversion of 25(OH)D to 1,25(OH)2D for endocrine purposes under the regulatory control of PTH, FGF23 and 1,25(OH)2D, other vitamin D activating sites exist. In fact, many tissues harbour cells capable of metabolising 25(OH)D and additionally express the VDR, resulting in the possibility of intracrine, autocrine and paracrine effects [4]. These include immune cells, different types of epithelial cells, bone cells and parathyroid cells. Control of 1,25(OH)2D production in these extrarenal cells differs from regulation within the kidneys, as receptors for PTH are lacking.

Here, the most important limiting factor is the availability of substrate [5]. The non-classical actions of 1,25(OH)2D in these cells involve local regulation of PTH secretion in the parathyroid gland, local regulation of insulin secretion in the pancreatic beta cells, modulating immune cell response in activated inflammatory cells and regulation of proliferation and differentiation in the keratinocytes [4].

Regulation of 25(OH)D metabolism, mediated by the two cytochrome P450 enzymes, is of crucial importance. When out of balance, serious complications may occur. Too high 1,25(OH)2D concentrations result in increased calcium absorption from the intestines leading to hypercalcaemia and associated serious effects. Too low concentrations will mean a shortage of free calcium or hypocalcaemia and the accompanying symptoms. As such, 1,25(OH)2D, is almost perpetually within normal limits, even when, based on 25(OH)D concentrations, the patient displays vitamin D deficiency.

Source: 2. Vitamin D Metabolism Source: 2. Vitamin D Metabolism Source: 2. Vitamin D Metabolism

Assessing Vitamin D Metabolism Misbalance

When & What: Assessing Vitamin D Metabolism Misbalance

3.1. 25(OH)D

Serum total 25(OH)D, the summation of 25(OH)D2 and 25(OH)D3, is the best reflection of vitamin D status. It is a better marker for vitamin D status than circulating 1,25(OH)2D, as the latter is tightly regulated and its levels are strictly kept between limits even when adverse effects start to occur. Next to renal 25(OH)D metabolism, the local extrarenal conversion of 25(OH)D into 1,25(OH)2D, accounts for the hormone’s non-calcaemic effects. Notably, these extrarenally produced 1,25(OH)2D levels will not be mirrored by the concentration of 1,25(OH)2D in the systemic circulation if the locally produced 1,25(OH)2D does not leave the extracellular confinements to enter the bloodstream.

In contrast, circulating 25(OH)D concentrations reflect the cellular 25(OH)D concentrations prior to conversion and as such, represent the available substrate for extrarenal 1,25(OH)D synthesis.

Advantageously, as 25(OH)D is the main circulating metabolite of vitamin D, high concentration facilitates its measurement.

Experts in the field of vitamin D have provided us with several reviews on the measurement of vitamin D status and interpretation of the results [6,7,8,9]. Nevertheless, disagreement still prevails, as consensus on the precise 25(OH)D concentrations representing vitamin D deficiency, insufficiency, sufficiency and intoxication has not yet been reached. One could argue that the 25(OH)D concentrations found in representative groups of individuals, asymptomatic for disease, are to be considered normal and desired [10,11,12].

However, many experts believe, as a result of changing diets and reduced levels of sun exposure, a large part of the world population is not vitamin D sufficient, and should therefore be supplemented [7,8,9,13,14]. They are convinced these higher 25(OH)D concentrations are necessary to prevent morbidity. According to the Institute of Medicine, serum 25(OH)D levels of 50 nmol/L (20 ng/mL) are sufficient to ensure skeletal health and only levels below 30 nmol/L (12 ng/mL) are to be considered universally inadequate, while levels between 30 and 50 nmol/L (12–20 ng/mL) potentially are, depending on the individual [15].

The Endocrine Society defines deficiency as 25(OH)D levels below 50 nmol/L (20 ng/mL) but recommends at least levels above 75 nmol/L (30 ng/mL), and preferably between 100 and 150 nmol/L (40–60 ng/mL), achieved by daily supplementation. However, both institutes deem population wide screening for vitamin D deficiency unnecessary and advise only to screen populations at risk [16]. Such groups include obese individuals, pregnant and lactating women, individuals with darker skin pigmentation, older adults with a history of falls or fractures, patients with rickets, osteomalacia, osteoporosis, chronic kidney disease (CKD), liver failure, hyperparathyroidism, granuloma-forming disorders, some lymphomas, malabsorption issues or nephrotic syndrome and patients on a wide range of medications, including anticonvulsants, glucocorticoids, antifungals and medication to treat HIV/AIDS [15,16].

3.2. 1,25(OH)2D

Counterintuitively, measuring 1,25(OH)2D as a marker for vitamin D homeostasis is irrelevant in most cases, as it will be within reference range, even when one is considered vitamin D deficient and experiences associated adverse effects. Specific conditions, however, may require the assessment of 1,25(OH)2D, of which concentrations normally range between 59 and 159 pmol/L (25–66 pg/mL) [17]. Several diseases may either increase or decrease 1,25(OH)2D concentration to undesirable levels [6].

These are all characterised by disturbed vitamin D metabolism on the level of 1,25(OH)2D production, which is often not reflected by altered 25(OH)D concentrations. The disorders may be classified according to three distinct origins of the 1,25(OH)2D production imbalance. First, and most common are disorders of the 1,25(OH)2D producing CYP27B1 enzyme. A second arises from mutations in the vitamin D receptor (VDR), rendering it unresponsive or less responsive to its substrate. Finally, a third category consists of conditions characterised by excessive extrarenal conversion of 25(OH)D into 1,25(OH)2D. 1α-hydroxylase deficiency, also known as vitamin D-dependent rickets type 1 or pseudo-vitamin D deficiency rickets, is an autosomal recessive disorder exemplary for the first category.

This rare disease is caused by an inactivating mutation in CYP27B1, resulting in abnormally low 1,25(OH)2D concentrations and early onset of rickets [18]. A number of disorders presenting as hypophosphatemic syndromes also belong to the first category. Many, but not all, of these syndromes are mediated by FGF23, and 1,25(OH)2D is an excellent marker to differentiate between the FGF23-mediated and non-FGF23-mediated syndromes. The genetic disorders X-linked hypophosphatemia (XLH), autosomal dominant hypophosphatemic rickets (ADHR), and autosomal recessive hypophosphatemic rickets 1,2 and 3 (ARHR1, ARHR2 and ARHR3), are all examples of the FGF23-mediated kind, as is the acquired tumour induced osteomalacia (TIO) [19,20,21,22,23,24,25,26].

Additionally, other rare disorders may manifest as FGF23-mediated hypophosphatemia, including osteoglophonic dysplasia, McCune–Albright syndrome, epidermal nevus syndrome, neurofibromatosis, hypophosphatemic rickets with hyperparathyroidism and Jansen metaphyseal chondrodysplasia [27,28,29,30,31,32]. Elevated FGF23 levels result in inhibition of CYP27B1 and subsequent low or inappropriately normal 1,25(OH)2D concentrations [33]. The non-FGF23-mediated disorders displaying hypophosphatemia, including hereditary hypophosphatemic rickets with hypercalciuria, idiopathic hypercalciuria and Fanconi syndrome display similar phenotypes yet, in contrast to the FGF23-mediated syndromes, result in normal FGF23 levels and normal or appropriately elevated 1,25(OH)2D concentrations [34,35,36].

Hereditary vitamin D-resistant rickets, also known as vitamin D-dependent rickets type 2 belongs to the second category and is caused by a mutation in VDR, rendering it unresponsive to its substrate, resulting in hypocalcaemia and early onset rickets. Very high 1,25(OH)2D concentrations are found in these individuals. Examples of the third category, sarcoidosis, tuberculosis, rheumatoid arthritis, inflammatory bowel disease and the lymphoproliferative disorders, are all characterised by the formation of lumps of inflammatory cells, or granulomas, with the capability of hydroxylation of 25(OH)D to form 1,25(OH)2D, facilitating antimicrobial and anti-inflammatory immune responses.

This extrarenal 1α-hydroxylation by local CYP27B1 is not controlled by PTH, FGFG23, phosphate or 1,25(OH)2D, but is regulated by local factors such as IFN-γ and IL15 and dependent on the availability of substrate [37]. When excessive, the locally produced 1,25(OH)2D may escape the confinements of the intracellular space, spill over to the systemic circulation, and raise blood 1,25(OH)2D concentrations to abnormally high levels [38]. Importantly, extrarenal 1α-hydroxylation is often associated with low bone mineral density. 1,25(OH)2D assessment is therefore not only of great clinical value in the diagnosis of the disease but also in the prevention of complications in the form of bone disorders [39,40].

In summary, requesting measurement of 1,25(OH)2D could be of use on suspicion of 1α-hydroxylase deficiency where very low 1,25(OH)2D concentrations are found. 1,25(OH)2D measurement also aids in separating the disorders presenting as hypophosphatemic syndromes mediated by FGF23, where normal to low 1,25(OH)2D concentrations are found, from the non-FGF23-mediated disorders with normal to high 1,25(OH)2D concentrations. Very high 1,25(OH)2D concentrations indicate hereditary vitamin D-resistant rickets or the presence of excessive extrarenal 1α-hydroxylation by granulomatous or lymphoproliferative diseases.

3.3. 24,25(OH)2D

The CYP24A1 enzyme catabolises excess 25(OH)D by converting it to the inactive 24,25(OH)2D. Its expression is not limited to the kidneys. Similar to CYP27B1, it expands to many different cell types, allowing for the local regulation of 25(OH)D and 1,25(OH)2D in target cells [41]. In a group of 92 healthy individuals evenly covering all age decades between 20 and 70 years, the 95% confidence interval of measured 24,25(OH)2D concentrations ranged from 0.5 to 11 nmol/L (0.2–4.6 ng/mL) and the 25(OH)D/24,25(OH)2D ratio ranged from eight to 27.

Concentrations of 24,25(OH)2D appeared to be independent from the presence or absence of vitamin D deficiency (own data).

Two articles by St Arnaud in the late nineties elaborately postulated 24,25(OH)2D as an additional active metabolite of 25(OH)D. A role in cartilage development, embryogenesis and in regulating bone growth, development and repair was proposed [42,43]. How 24,25(OH)2D exerted these effects remained unclear, which led the authors to theorise on the existence of a specific nuclear or membrane receptor for 24,25(OH)2D. To this day, researchers are still questioning the active physiological role of 24,25(OH)2D and the possible existence of a dedicated receptor.

Nonetheless, irrespective of its supposed activity, measuring 24,25(OH)2D undeniably has value, as several studies have proven during the years following St Arnaud’s articles. Unsurprisingly, the 25(OH)D/24,25(OH)2D ratio is an indicator of CYP24A1 activity and vitamin D catabolism therewith [44,45]. In that capacity, the ratio can identify a rare genetic disorder, idiopathic infantile hypercalcaemia (IIH). Infants suffering from this disorder display severe hypercalcaemia and suppressed PTH levels due to their severely impaired capacity to catabolise 25(OH)D and 1,25(OH)2D, as a result of an inactivating mutation in the gene coding for CYP24A1 [45,46].

Similarly, less harsh inactivating mutations may result in nephrocalcinosis and nephrolithiasis in adult life, secondary to hypercalciuria and often hypercalcaemia [47,48,49]. The effectiveness of the 25(OH)D/24,25(OH)2D ratio was further established in a cohort of hypercalcaemic patients, in which it correctly identified those patients harbouring an inactivating CYP24A1 mutation [50]. Aditionally, an elevated 25(OH)D/24,25(OH)2D ratio predicts vitamin D defiency to at least a similar extent as increased PTH does, and might be of potential use as an indicator of vitamin D deficiency [45,51].

In conclusion, the 25(OH)D/24,25(OH)2D ratio is an unambiguous marker for vitamin D catabolism and may identify patients with hypercalcaemia secondary to CYP24A1 mutations, such as patients with IIH.

3.4. Other Metabolites

Beyond 25(OH)D, 1,25(OH)2D and 24,25(OH)2D many more vitamin D metabolites have been identified, yet these are scarcely measured. With the current state of techniques, many of the metabolites circulating at concentrations below that of 1,25(OH)2D will be unquantifiable and the value of these metabolites for diagnostics remains elusive. Nevertheless, future studies may find ways of detecting and using these metabolites to provide new diagnostic tools in the years to come.

Source: 3. When & What: Assessing Vitamin D Metabolism Misbalance Source: 3. When & What: Assessing Vitamin D Metabolism Misbalance Source: 3. When & What: Assessing Vitamin D Metabolism Misbalance Source: 3. When & What: Assessing Vitamin D Metabolism Misbalance

How: Importance of the Choice of Method

4.1. 25(OH)D

25(OH)D can be measured in many different ways, yet two techniques dominate: automated immunoassay and liquid chromatography coupled to tandem-mass spectrometry (LC-MS/MS). According to the Vitamin D External Quality Assessment Scheme (DEQAS), overseeing method comparability across 54 countries, in October 2017, ~76% of the 871 participating laboratories used an automated immunoassay to measure their 25(OH)D, while ~18% used LC-MS/MS, ~3% used a manual immunoassay and ~2% used HPLC. During recent years, several studies addressed the limitations of the automated, and less frequently the manual immunoassays, when measuring in patients [52,53,54,55,56,57].

While in healthy individuals, the assays correlate nicely with the standardised LC-MS/MS method, measuring 25(OH)D in patient groups has revealed huge deviations [52,55,56,58]. This brings to light some of the major issues with the automated and manual immunoassays. First, the lack of sample preparation in the automated immunoassays allows for the emergence of severe interferences from miscellaneous origins. Differing concentrations of DBP, which are greatly affected in certain populations, such as in pregnant women, intensive care patients and patients with liver failure, may be a common problem affecting results [55,58,59].

Similarly, the automated immunoassays often have incomprehensible difficulties measuring 25(OH)D in haemodialysis patients and osteoporotic patients [52,55,57]. Unlike with the automated immunoassays, sample preparation for the HPLC, manual immunoassays and LC-MS/MS methods is adaptable and can be optimised to reduce any adverse effects that varying DBP concentrations or other contributing factors may bring. A second origin of bias for both the automated and manual immunoassays is related to the specificity of the used antibodies.

As mentioned before, 25(OH)D may be present in one of two forms, 25(OH)D2 or 25(OH)D3. Immunoassays are generally not able to distinguish the two, and report these together as total 25(OH)D. As the antibodies in the immunoassay do not bind 25(OH)D2 to a similar extent as they bind 25(OH)D3, this leads to the under- or over-estimation of total 25(OH)D [60,61,62,63,64]. Alarmingly, many automated immunoassay manufacturers report considerably different cross-reactivity percentages for 25(OH)D2 compared to the observed values by independent researchers [65,66].

This is particularly problematic in countries were supplementing with vitamin D2 is more common, for example the USA. On the contrary, LC-MS/MS has no problem measuring 25(OH)D2 alongside 25(OH)D3, as the mass difference of 12 Da is easily separated by mass spectrometry. Another inherent specificity problem for the assays using antibodies, is cross-reactivity with other vitamin D metabolites. 24,25(OH)2D3, present in about 10–15% of the 25(OH)D concentration, has proven to greatly impact immunoassays and produces falsely high results [51,67,68].

Similar to 25(OH)D2, 24,25(OH)2D3, has a different mass to 25(OH)D3 and poses no threat to the reliability of LC-MS/MS methods [67]. Epi-25(OH)D, the result of epimerisation of 25(OH)D, with levels that are highest in neonates up to one year of age and present in most adults at about 9% of 25(OH)D, does not influence the results of immunoassays, as antibodies do not recognise it [61,69,70].

Many LC-MS/MS assays, on the other hand, experience difficulties distinguishing the two epimers due to their equal mass and their similar affinity for most LC columns, resulting in an overestimation, and potential misclassification, of total 25(OH)D [61,69,71,72]. Several LC-MS/MS assays now use non-C18 columns enabling them to chromatographically separate the epimer and measure it independently of 25(OH)D, despite the identical masses [45,68,73,74,75,76].

When the first LC-MS/MS methods for 25(OH)D made their entry, DEQAS reported unflatteringly high interlaboratory differences in the measurement of 25(OH)D. Carter and Jones showed these differences were often attributable to the use of in-house calibrated standards, and significantly abated after the use of a shared standard [77]. Indeed, another study showed LC-MS/MS methods for 25(OH)D generally correlated nicely and small biases originated from differences in calibration procedures [78]. Thanks to the Vitamin D Standardization Program (VDSP) and the target value DEQAS now provides for participants, laboratories operating miscalibrated LC-MS/MS methods have the possibility to standardise their methods using the reference measurement procedure, which is crucial for their performance.

In earlier years, automated immunoassays had largely replaced manual assays with their easy operation and higher throughput. However, all the aforementioned flaws of the immunoassays that were brought to light in certain patient groups, have now tipped the scales in favour of the LC-MS/MS. Today, LC-MS/MS is slowly replacing automated immunoassays in clinical laboratories. Due to the necessity of more complex and expensive equipment and highly skilled technicians, most of the smaller laboratories still depend on the manual and automated immunoassays.

Manual immunoassays may still be well-suited for 25(OH)D measurement in patient groups where adequate sample preparation resolves the specificity issues of the technique. Automated immunoassays may still be suitable for the determination of 25(OH)D concentrations in large cohorts of healthy individuals, where interferences and supplementation are less frequent. We must conclude however, that measuring 25(OH)D in a clinical setting benefits greatly from the transition from automated immunoassays to LC-MS/MS. Still, attention to the specifications and quality of LC-MS/MS methods is advised.

Particular specifications, such as separately quantifying epi-25(OH)D3 in neonates, may be crucial. Standardisation and the resulting good agreement with the DEQAS target value or performance within the VDSP defines high quality methods. Without data on method agreement, DEQAS performance or standardisation, the quality and suitability of a method is indefinable and the possibility of misclassification exists.

Of note, a few laboratories still run HPLC methods for their 25(OH)D determination. While most of the advantages of LC-MS/MS over immunoassays also hold true for HPLC, mass spectrometers have largely replaced the UV detectors used in combination with HPLC, for their superior sensitivity and specificity. The advantages and disadvantages of today’s two most widely used techniques, immunoassays and LC-MS/MS for 25(OH)D measurement are summarised in Table 1.

All things considered, LC-MS/MS is the preferred technique for 25(OH)D measurement in patients, without the knowledge of any present interferences that might hinder its determination. The use of immunoassays is not advised in specific patient groups, including IC, haemodialysis, osteoporotic and liver failure patients, pregnant women, neonates and individuals on D2 supplementation, and caution is warranted in unstudied patient groups.

4.2. 1,25(OH)2D

As a result of the very low concentrations of circulating 1,25(OH)2D and the specialised circumstances under which its analysis is deemed necessary, fewer laboratories conduct this measurement. Of the 165 methods that participated in the DEQAS distribution of October 2017, ~75% of laboratories used an automated immunoassay to measure 1,25(OH)2D, ~17% used a manual immunoassay and ~9% used LC-MS/MS. Similar to measuring 25(OH)D, the methods for measuring 1,25(OH)2D each have their advantages and disadvantages (Table 1), making the selection of one of them difficult and relevant.

Previously, the field of 1,25(OH)2D measurement was dominated by radio-immunoassays. These assays often suffered from substantial cross-reactivity with other vitamin D metabolites and were unable to produce evincive results [79,80]. In the case of the 1,25(OH)2D assays, the newest automated immunoassays perform similarly to LC-MS/MS and no apparent specificity problem exists. Here, the overall unaccountable lack of good correlations between assays on all platforms is most problematic [17,81,82].

Without the presence of a reference method, identifying the methods that deviate is very difficult, if not impossible. A recently developed automated immunoassay shows good correlations to some of the LC-MS/MS methods that include an immunopurification step in their sample preparation, while lesser correlations are found with others that do not [82,83,84]. LC-MS/MS methods without immunopurification included in their sample preparation might suffer from isobaric interferences, such as 1β-25-dihydroxyvitamin D3, which would not be co-captured by the antibodies in the automated immunoassay [85].

Additionally, as with 25(OH)D, differences in calibration procedures are a likely cause of deviations and methods would substantially benefit from a target value provided by DEQAS and subsequent standardisation.

While immunoassays are quite easily capable of measuring very low concentrations of 1,25(OH)2D due to the inherent amplifying nature of the technique, LC-MS/MS assays struggle gaining enough sensitivity to accurately measure in the lower ranges of physiological concentrations. One way to overcome this is the use of more sophisticated chromatography. By making use of a 2D chromatography system, background noise is reduced and befouling of the MS instrument diminished. It comprises of two parallel connected columns. Only when the analytes of interest elute from the first column is it connected to the second column.

Before and after this moment, flow is directed towards a waste. Another option is derivatisation of the vitamin D molecule. By chemical transformation of the molecule into something more easily ionised, sensitivity is improved. For the vitamin D molecules, several derivatisation agents are available. Most of them are based on the same Diels–Alder reaction taking place on the diene structure adjacent to the A-ring in the backbone of vitamin D. The diophenile molecules differ in the groups attached to their triazole backbone.

The two most widely used derivatisation agents are PTAD and Amplifex.

As expected, the assays using a derivatisation agent generally report lower limits of quantification (LOQs), with levels up to 2.5 pmol/L [17,75,80,86,87,88]. The assays not using derivatisation require more elaborative sample preparation (immunopurification), increased sample volume (>0.5 mL), more sophisticated LC-MS/MS systems (µLC or 2D chromatography) or do not reach desirable LOQs [74,88,89,90,91,92]. The lowest LOQs have been reached using immunopurification followed by PTAD derivatisation [17,80].

Using Amplifex has the advantage of not requiring an immunopurification step, which makes it possible to include additional vitamin D metabolites aside from 1,25(OH)D3 and 1,25(OH)D2, but impedes the chromatographic separation of epimers.

It is difficult to convincingly argue in favour of one technique over the other in the case of 1,25(OH)2D. When separate quantification of 1,25(OH)2D3 and 1,25(OH)2D2 is preferable, in countries with vitamin D2 supplementation, LC-MS/MS is the only option. Notwithstanding, in the case of 25(OH)D, standardisation and subsequent amelioration of LC-MS/MS methods exposed the pitfalls of the immunoassays. With the 1,25(OH)2D methods, a similar chain of insights may lay ahead.

Without the availability of a reference method, though, standardisation is not an option and identifying the origin of biases between methods and prescribing necessities for 1,25(OH)2D measurements in clinical diagnostics is difficult. Nonetheless, three things are evident from the available data. First, there is no incontestable difference of outcome between the newest automated immunoassays and LC-MS/MS. Second, when using a dedicated LC-MS/MS method for 1,25(OH)2D, incorporation of immunopurification in the sample preparation generally leads to a method with greater sensitivity and specificity.

Third, when measuring multiple vitamin D metabolites at the same time, immunopurification is not applicable and LC conditions and sensitivity optimisation need considerable attention to accurately measure each metabolite at endogenous concentrations.

4.3. 24,25(OH)2D

Several laboratories have developed methods for the quantification of 24,25(OH)2D. Those participating in the DEQAS distribution all use LC-MS/MS, despite the existence of a 24,25(OH)2D radio-immunoassay. The advantages and disadvantages of LC-MS/MS methods are depicted in Table 1. Most of them, but not all, use an isotopically labelled standard to aid them in accurate measurement. The methods measuring 24,25(OH)2D have usually incorporated additional vitamin D metabolites in their analysis. One thing to consider is the application of a derivatisation agent. 24,25(OH)2D is present at about 10% of the 25(OH)D concentration.

As a result, similar to 1,25(OH)2D, it is not easily measured by our current high-end LC-MS/MS systems without extra efforts to improve sensitivity. One of the options is derivatising the metabolite with a derivatisation agent, like PTAD, DMEQ-TAD or Amplifex [45,75,88,93]. This increases sensitivity considerably, yet unfortunately PTAD thwarts the separate quantification of epi-25(OH)D3. Without derivatisation, higher LOQs are reported, additional efforts in other areas have to be undertaken to acquire similar LOQs, or higher sample volumes are required [44,68,73,74,86,94,95].

A candidate reference method was published by Tai and Nelson with high precision and accuracy [96]. Using five serum samples identified by the NIST as Standard Reference Material (SRM) and 30 samples from the DEQAS distribution, the candidate reference method and five laboratories routinely measuring 24,25(OH)2D assessed their comparability [97]. Mean biases of the participants ranged from −15% to 36% for the SRM samples and from 6% to 15% for the DEQAS samples. A significant SD of the mean bias for some of the laboratories indicated room for precision improvement.

Overall, significant biases with the candidate reference method for 24,25(OH)2D shows we are long from uniform measurement of the metabolite. This is especially problematic when measuring the 25(OH)D/24,25(OH)2D ratio as it becomes unreliable and inaccurate when either one of the two methods is unstandardised. Further efforts for standardisation, including the availability of the SRMs and provision of a target value by DEQAS, are a necessity for uniform measurement and interpretation.

The measurement of 24,25(OH)2D remains mainly research driven instead of clinical, and data on method comparison is scarce. In consequence, designating high quality methods is difficult. In the coming years, 24,25(OH)2D will probably be more widely incorporated in clinical laboratories and attention to standardisation will lead to its solid anchoring within vitamin D metabolism diagnostics.

4.4. Other Metabolites

A number of the aforementioned LC-MS/MS methods measure additional metabolites. Where, in the case of epi-25(OH)D3, the value of measurement in neonates is well established, for other metabolites, such as 4β,25(OH)2D3, 23(R),25(OH)2D3 and 24(OH)D, the significance is not clear. These metabolites are usually incorporated in LC-MS/MS methods after being identified as an interference, and subsequently chromatographically separated and quantified. To date, a real reason to quantitatively measure these additional vitamin D metabolites is lacking, and nothing can be stated about the importance of the choice of method.

Table 1

Advantages and disadvantages of current LC-MS/MS methods and immunoassays for vitamin D metabolism determination.

MetaboliteLC-MS/MSImmunoassay
25(OH)DAdvantages:
  • Sample preparation adaptable

  • Specificity

Disadvantages:
  • Complexity

  • Difficult to separate epi-25(OH)D3 from 25(OH)D3 (same mass and chromatographic behaviour)

Advantages *:
  • Fast

  • Easy operation

  • No cross reactivity with epi-25(OH)D

Disadvantages:
  • Patient group-dependent deviations

  • No distinction between 25(OH)D2 and 25(OH)D3

  • Cross-reactivity of other vitamin D metabolites recognised by the antibody, such as 24,25(OH)2D

1,25(OH)2DAdvantages:
  • Sample preparation adaptable

  • Specificity

Disadvantages:
  • Complexity

  • Sensitivity

  • Possible cross-reactivity from isobaric interferences

Advantages:
  • Fast

  • Easy operation

  • Sensitivity

Disadvantages:
  • No distinction between 1,25(OH)2D2 and 1,25(OH)2D3

  • Cross-reactivity of other vitamin D metabolites recognised by the antibody, such as 25(OH)D3 and 24,25(OH)2D

24,25(OH)2DAdvantages:
  • Sample preparation adaptable

  • Specificity

Disadvantages:
  • Complexity

N/A †N/A †

* The advantages listed are limited to the automated immunoassays. † Although 24,25(OH)2D immunoassays exist, too little information on their performance is available.

Source: 4. How: Importance of the Choice of Method Source: 4. How: Importance of the Choice of Method Source: 4. How: Importance of the Choice of Method Source: 4. How: Importance of the Choice of Method Source: 4. How: Importance of the Choice of Method

Discussion and Conclusions

While the reasons for measuring 25(OH)D have often been described, the value of measuring its metabolites, 1,25(OH)2D and especially 24,25(OH)2D, remains largely unappreciated. In short, indications where measurement of 1,25(OH)2D may contribute to diagnosis or aid in monitoring treatment include conditions where production of 1,25(OH)2D is heavily disturbed, resulting in either a shortage of 1,25(OH)2D, such as in 1α-hydroxylase deficiency, or an overabundance of 1,25(OH)2D, such as in hereditary vitamin D-resistant rickets, sarcoidosis, tuberculosis, rheumatoid arthritis, inflammatory bowel disease and lymphoproliferative diseases. 1,25(OH)2D also helps to identify the hypophosphatemic syndromes mediated by FGF23, including XLH, ADHR, ARHR and TIO.

Measuring 24,25(OH)2D enables identification of CYP24A1 mutations leading to impaired catabolism of the hormone and associated hypercalcaemia, such as in IIH.

For determination of these analytes in the clinical laboratory, we have long relied on immunoassays. The automation of assays increased throughput and reduced complexity. However, the emergence of LC-MS/MS has provided us with new insight into their limitations. Yes, automated immunoassays may be fast, less laborious and sensitive, but the superiority of LC-MS/MS assays regarding specificity is evident and has revealed some serious issues that hinder immunoassays from producing reliable results in certain patient groups. The problems that may arise when selecting a method without the necessary characteristics are less obvious but no less important.

In a number of patient groups, including pregnant women, intensive care patients, patients with liver failure, haemodialysis patients and osteoporotic patients, automated immunoassays have proven unreliable. Measuring 25(OH)D in these patients with an automated immunoassay is therefore not advised. As there is usually no prior knowledge of the possible interferences in a patient sample, LC-MS/MS is the preferred method for 25(OH)D determination in patient diagnostics.

All in all, measuring vitamin D metabolism has greatly benefitted from the entry of LC-MS/MS in clinical laboratories. It enabled us to drastically improve specificity and accuracy, and provided us with the ability to co-measure multiple metabolites simultaneously. It has already proven very useful in the diagnosis of numerous conditions and new generations of more sensitive LC-MS/MS instruments will enable us to further meticulously study, to date unexplained, vitamin D metabolism-related conditions. If immunoassay manufacturers succeed in improving their newer generations of automated immunoassays, as has happened with the 2nd generation testosterone immunoassays, they may overcome the problems they face today and prove reliable in patient diagnostics [98].

By the same token, the disadvantages of today’s LC-MS/MS instruments, being quite laborious, may be resolved by more easy to use instruments and the introduction of fully automated LC-MS/MS systems. Additionally, further efforts in the standardisation of assays are needed to raise the overall quality of these methods and provide clinicians with reliable results.

Conclusively, measuring vitamin D metabolites is, and will be important, to diagnose a number of different conditions. Attention to the when, the what and the how of measuring vitamin D metabolism greatly benefits diagnostic and research power.

Source: 5. Discussion and Conclusions Source: 5. Discussion and Conclusions Source: 5. Discussion and Conclusions Source: 5. Discussion and Conclusions
Authors’ abstract

We now have the ability to measure a number of different vitamin D metabolites with very accurate methods. The most abundant vitamin D metabolite, 25-hydroxyvitamin D, is currently the best marker for overall vitamin D status and is therefore most commonly measured in clinical medicine. The added value of measuring metabolites beyond 25-hydroxyvitamin D, like 1,25-, and 24,25-dihydroxyvitamin D is not broadly appreciated. Yet, in some more complicated cases, these metabolites may provide just the information needed for a legitimate diagnosis.

The problem at present, is knowing when to measure, what to measure and how to measure. For 25-hydroxyvitamin D, the most frequently used automated immunoassays do not meet the requirements of today’s standards for certain patient groups and liquid chromatography-tandem mass spectrometry is the desired method of choice in these individuals. The less frequently measured 1,25-dihydroxyvitamin D metabolite enables us to identify a number of conditions, including 1α-hydroxylase deficiency, hereditary vitamin D-resistant rickets and a number of granulomatous diseases or lymphoproliferative diseases accompanied by hypercalcaemia.

Furthermore, it discriminates between the FGF23-mediated and non-FGF23-mediated hypophosphatemic syndromes. The 24,25-dihydroxyvitamin D metabolite has proven its value in the diagnosis of idiopathic infantile hypercalcaemia and has the potential of having value in identifying other diseases. For both metabolites, the understanding of the origin of differences between assays is limited and requires further attention. Nonetheless, in every way, appropriate measurement of vitamin D metabolism in the clinical laboratory hinges eminently on the comprehension of the value of the different metabolites, and the importance of the choice of method.

Read the full paper

1. Introduction

With the ever-growing family of measurable vitamin D metabolites and techniques to assess them, comes a predicament. How does a clinician decide when measurement of vitamin D metabolism benefits the diagnostic process? What metabolic product of vitamin D provides the necessary answers, and how best to measure it? The goal of this review is to clarify the value of measuring vitamin D metabolites in diagnostics and to illustrate which metabolite is to be measured under which circumstances, and why. Additionally, the choice of method is discussed, as this is an important aspect of appropriate vitamin D metabolism measurement.

The paper is structured as follows. Section 2 is dedicated to the metabolism of vitamin D. Knowledge of the processes and the stimulatory and inhibitory factors involved in this ingenious metabolic pathway is a prerequisite for understanding the benefits and relevance of measuring the different metabolites. Section 3 focuses on the when and what, situations where the major vitamin D metabolites may contribute to a fitting diagnosis or monitoring of a disease. Section 4, on the how, explores the different methods a present-day laboratory may offer to measure the desired metabolites.

As not all available methods are suitable for every situation, knowing the flaws and pitfalls of the various measurement procedures is important to prevent a misdiagnosis or missed diagnosis. In the end, everyone benefits from a faster, more reliable and more economical way to achieve proper diagnosis by knowing when to measure, what to measure and how to measure vitamin D metabolites in a clinical setting.

2. Vitamin D Metabolism

Vitamin D metabolism (Figure 1) is a complex and ingenious process proceeding inside multiple organs within the human body to maintain calcium homeostasis and control bone metabolism. It all starts with 7-dehydrocholesterol which, when exposed to UVB light in the human skin, transforms into vitamin D3 through intermediate isomer pre-vitamin D3. Alternatively, a small portion of vitamin D3 may be directly ingested by the consumption of animal products. Another isomeric form, vitamin D2, is not synthesised by our own body, but may be extracted from some plants and fungi.

Both forms behave similarly and undergo the same metabolic process. Both activated forms also bind to the vitamin D receptor (VDR), although the active metabolite of vitamin D3 has proven to be more potent [1]. From here, if there is no need for the distinction between the two isomers, vitamin D and associated metabolic products refer to both species. Cutaneously synthesised or ingested vitamin D is subsequently transported to the liver, usually bound to a vitamin D binding protein (DBP), where hydroxylation on the 25-position by hepatic CYP2R1 (25-hydroxylase) yields 25-hydroxyvitamin D (25(OH)D).

The hormonally active 1,25-dihydroxyvitamin D (1,25(OH)2D) is produced in the proximal renal tubule by the mitochondrial CYP27B1 enzyme (1α-hydroxylase), after a second hydroxylation at the 1-position. To retain 1,25(OH)2D concentrations within the strict boundaries required for appropriate calcium homeostasis and bone metabolism, both 1,25(OH)2D and 25(OH)D may undergo further hydroxylation by renal CYP24A1 (24-hydroxylase), leading, respectively, to 1,24,25-trihydroxyvitamin D and 24(R),25-dihydroxyvitamin D (24,25(OH)2D), with negligible affinity for the VDR. In addition, all of the aforementioned metabolites are subject to C-3 epimerisation resulting in products with lower VDR and DBP binding affinities and reduced activity compared to their unepimerised counterparts [2].

This metabolic process is tightly controlled by a number of regulators. Parathyroid hormone (PTH) stimulates production of 1,25(OH)2D by upregulating CYP27B1 gene expression, while inhibiting expression of CYP24A1. Fibroblast growth factor 23 (FGF23) inhibits CYP27B1 and stimulates CYP24A1, thus preventing the production of 1,25(OH)2D and stimulating its catabolism [3]. Calcium decreases CYP27B1 activity directly and through inhibition of the action as exerted by PTH, all leading to lower 1,25(OH)2D concentrations. Lack of phosphate (hypophosphatemia) results in the opposite, by stimulating CYP27B1 and inhibiting CYP24A1 expression. 1,25(OH)2D itself supresses CYP27B1 and stimulates CYP24A1, thereby promoting its own degradation when excessively present.

Apart from the well-documented renal conversion of 25(OH)D to 1,25(OH)2D for endocrine purposes under the regulatory control of PTH, FGF23 and 1,25(OH)2D, other vitamin D activating sites exist. In fact, many tissues harbour cells capable of metabolising 25(OH)D and additionally express the VDR, resulting in the possibility of intracrine, autocrine and paracrine effects [4]. These include immune cells, different types of epithelial cells, bone cells and parathyroid cells. Control of 1,25(OH)2D production in these extrarenal cells differs from regulation within the kidneys, as receptors for PTH are lacking.

Here, the most important limiting factor is the availability of substrate [5]. The non-classical actions of 1,25(OH)2D in these cells involve local regulation of PTH secretion in the parathyroid gland, local regulation of insulin secretion in the pancreatic beta cells, modulating immune cell response in activated inflammatory cells and regulation of proliferation and differentiation in the keratinocytes [4].

Regulation of 25(OH)D metabolism, mediated by the two cytochrome P450 enzymes, is of crucial importance. When out of balance, serious complications may occur. Too high 1,25(OH)2D concentrations result in increased calcium absorption from the intestines leading to hypercalcaemia and associated serious effects. Too low concentrations will mean a shortage of free calcium or hypocalcaemia and the accompanying symptoms. As such, 1,25(OH)2D, is almost perpetually within normal limits, even when, based on 25(OH)D concentrations, the patient displays vitamin D deficiency.

3. When & What: Assessing Vitamin D Metabolism Misbalance

3.1. 25(OH)D

Serum total 25(OH)D, the summation of 25(OH)D2 and 25(OH)D3, is the best reflection of vitamin D status. It is a better marker for vitamin D status than circulating 1,25(OH)2D, as the latter is tightly regulated and its levels are strictly kept between limits even when adverse effects start to occur. Next to renal 25(OH)D metabolism, the local extrarenal conversion of 25(OH)D into 1,25(OH)2D, accounts for the hormone’s non-calcaemic effects. Notably, these extrarenally produced 1,25(OH)2D levels will not be mirrored by the concentration of 1,25(OH)2D in the systemic circulation if the locally produced 1,25(OH)2D does not leave the extracellular confinements to enter the bloodstream.

In contrast, circulating 25(OH)D concentrations reflect the cellular 25(OH)D concentrations prior to conversion and as such, represent the available substrate for extrarenal 1,25(OH)D synthesis.

Advantageously, as 25(OH)D is the main circulating metabolite of vitamin D, high concentration facilitates its measurement.

Experts in the field of vitamin D have provided us with several reviews on the measurement of vitamin D status and interpretation of the results [6,7,8,9]. Nevertheless, disagreement still prevails, as consensus on the precise 25(OH)D concentrations representing vitamin D deficiency, insufficiency, sufficiency and intoxication has not yet been reached. One could argue that the 25(OH)D concentrations found in representative groups of individuals, asymptomatic for disease, are to be considered normal and desired [10,11,12].

However, many experts believe, as a result of changing diets and reduced levels of sun exposure, a large part of the world population is not vitamin D sufficient, and should therefore be supplemented [7,8,9,13,14]. They are convinced these higher 25(OH)D concentrations are necessary to prevent morbidity. According to the Institute of Medicine, serum 25(OH)D levels of 50 nmol/L (20 ng/mL) are sufficient to ensure skeletal health and only levels below 30 nmol/L (12 ng/mL) are to be considered universally inadequate, while levels between 30 and 50 nmol/L (12–20 ng/mL) potentially are, depending on the individual [15].

The Endocrine Society defines deficiency as 25(OH)D levels below 50 nmol/L (20 ng/mL) but recommends at least levels above 75 nmol/L (30 ng/mL), and preferably between 100 and 150 nmol/L (40–60 ng/mL), achieved by daily supplementation. However, both institutes deem population wide screening for vitamin D deficiency unnecessary and advise only to screen populations at risk [16]. Such groups include obese individuals, pregnant and lactating women, individuals with darker skin pigmentation, older adults with a history of falls or fractures, patients with rickets, osteomalacia, osteoporosis, chronic kidney disease (CKD), liver failure, hyperparathyroidism, granuloma-forming disorders, some lymphomas, malabsorption issues or nephrotic syndrome and patients on a wide range of medications, including anticonvulsants, glucocorticoids, antifungals and medication to treat HIV/AIDS [15,16].

3.2. 1,25(OH)2D

Counterintuitively, measuring 1,25(OH)2D as a marker for vitamin D homeostasis is irrelevant in most cases, as it will be within reference range, even when one is considered vitamin D deficient and experiences associated adverse effects. Specific conditions, however, may require the assessment of 1,25(OH)2D, of which concentrations normally range between 59 and 159 pmol/L (25–66 pg/mL) [17]. Several diseases may either increase or decrease 1,25(OH)2D concentration to undesirable levels [6].

These are all characterised by disturbed vitamin D metabolism on the level of 1,25(OH)2D production, which is often not reflected by altered 25(OH)D concentrations. The disorders may be classified according to three distinct origins of the 1,25(OH)2D production imbalance. First, and most common are disorders of the 1,25(OH)2D producing CYP27B1 enzyme. A second arises from mutations in the vitamin D receptor (VDR), rendering it unresponsive or less responsive to its substrate. Finally, a third category consists of conditions characterised by excessive extrarenal conversion of 25(OH)D into 1,25(OH)2D. 1α-hydroxylase deficiency, also known as vitamin D-dependent rickets type 1 or pseudo-vitamin D deficiency rickets, is an autosomal recessive disorder exemplary for the first category.

This rare disease is caused by an inactivating mutation in CYP27B1, resulting in abnormally low 1,25(OH)2D concentrations and early onset of rickets [18]. A number of disorders presenting as hypophosphatemic syndromes also belong to the first category. Many, but not all, of these syndromes are mediated by FGF23, and 1,25(OH)2D is an excellent marker to differentiate between the FGF23-mediated and non-FGF23-mediated syndromes. The genetic disorders X-linked hypophosphatemia (XLH), autosomal dominant hypophosphatemic rickets (ADHR), and autosomal recessive hypophosphatemic rickets 1,2 and 3 (ARHR1, ARHR2 and ARHR3), are all examples of the FGF23-mediated kind, as is the acquired tumour induced osteomalacia (TIO) [19,20,21,22,23,24,25,26].

Additionally, other rare disorders may manifest as FGF23-mediated hypophosphatemia, including osteoglophonic dysplasia, McCune–Albright syndrome, epidermal nevus syndrome, neurofibromatosis, hypophosphatemic rickets with hyperparathyroidism and Jansen metaphyseal chondrodysplasia [27,28,29,30,31,32]. Elevated FGF23 levels result in inhibition of CYP27B1 and subsequent low or inappropriately normal 1,25(OH)2D concentrations [33]. The non-FGF23-mediated disorders displaying hypophosphatemia, including hereditary hypophosphatemic rickets with hypercalciuria, idiopathic hypercalciuria and Fanconi syndrome display similar phenotypes yet, in contrast to the FGF23-mediated syndromes, result in normal FGF23 levels and normal or appropriately elevated 1,25(OH)2D concentrations [34,35,36].

Hereditary vitamin D-resistant rickets, also known as vitamin D-dependent rickets type 2 belongs to the second category and is caused by a mutation in VDR, rendering it unresponsive to its substrate, resulting in hypocalcaemia and early onset rickets. Very high 1,25(OH)2D concentrations are found in these individuals. Examples of the third category, sarcoidosis, tuberculosis, rheumatoid arthritis, inflammatory bowel disease and the lymphoproliferative disorders, are all characterised by the formation of lumps of inflammatory cells, or granulomas, with the capability of hydroxylation of 25(OH)D to form 1,25(OH)2D, facilitating antimicrobial and anti-inflammatory immune responses.

This extrarenal 1α-hydroxylation by local CYP27B1 is not controlled by PTH, FGFG23, phosphate or 1,25(OH)2D, but is regulated by local factors such as IFN-γ and IL15 and dependent on the availability of substrate [37]. When excessive, the locally produced 1,25(OH)2D may escape the confinements of the intracellular space, spill over to the systemic circulation, and raise blood 1,25(OH)2D concentrations to abnormally high levels [38]. Importantly, extrarenal 1α-hydroxylation is often associated with low bone mineral density. 1,25(OH)2D assessment is therefore not only of great clinical value in the diagnosis of the disease but also in the prevention of complications in the form of bone disorders [39,40].

In summary, requesting measurement of 1,25(OH)2D could be of use on suspicion of 1α-hydroxylase deficiency where very low 1,25(OH)2D concentrations are found. 1,25(OH)2D measurement also aids in separating the disorders presenting as hypophosphatemic syndromes mediated by FGF23, where normal to low 1,25(OH)2D concentrations are found, from the non-FGF23-mediated disorders with normal to high 1,25(OH)2D concentrations. Very high 1,25(OH)2D concentrations indicate hereditary vitamin D-resistant rickets or the presence of excessive extrarenal 1α-hydroxylation by granulomatous or lymphoproliferative diseases.

3.3. 24,25(OH)2D

The CYP24A1 enzyme catabolises excess 25(OH)D by converting it to the inactive 24,25(OH)2D. Its expression is not limited to the kidneys. Similar to CYP27B1, it expands to many different cell types, allowing for the local regulation of 25(OH)D and 1,25(OH)2D in target cells [41]. In a group of 92 healthy individuals evenly covering all age decades between 20 and 70 years, the 95% confidence interval of measured 24,25(OH)2D concentrations ranged from 0.5 to 11 nmol/L (0.2–4.6 ng/mL) and the 25(OH)D/24,25(OH)2D ratio ranged from eight to 27.

Concentrations of 24,25(OH)2D appeared to be independent from the presence or absence of vitamin D deficiency (own data).

Two articles by St Arnaud in the late nineties elaborately postulated 24,25(OH)2D as an additional active metabolite of 25(OH)D. A role in cartilage development, embryogenesis and in regulating bone growth, development and repair was proposed [42,43]. How 24,25(OH)2D exerted these effects remained unclear, which led the authors to theorise on the existence of a specific nuclear or membrane receptor for 24,25(OH)2D. To this day, researchers are still questioning the active physiological role of 24,25(OH)2D and the possible existence of a dedicated receptor.

Nonetheless, irrespective of its supposed activity, measuring 24,25(OH)2D undeniably has value, as several studies have proven during the years following St Arnaud’s articles. Unsurprisingly, the 25(OH)D/24,25(OH)2D ratio is an indicator of CYP24A1 activity and vitamin D catabolism therewith [44,45]. In that capacity, the ratio can identify a rare genetic disorder, idiopathic infantile hypercalcaemia (IIH). Infants suffering from this disorder display severe hypercalcaemia and suppressed PTH levels due to their severely impaired capacity to catabolise 25(OH)D and 1,25(OH)2D, as a result of an inactivating mutation in the gene coding for CYP24A1 [45,46].

Similarly, less harsh inactivating mutations may result in nephrocalcinosis and nephrolithiasis in adult life, secondary to hypercalciuria and often hypercalcaemia [47,48,49]. The effectiveness of the 25(OH)D/24,25(OH)2D ratio was further established in a cohort of hypercalcaemic patients, in which it correctly identified those patients harbouring an inactivating CYP24A1 mutation [50]. Aditionally, an elevated 25(OH)D/24,25(OH)2D ratio predicts vitamin D defiency to at least a similar extent as increased PTH does, and might be of potential use as an indicator of vitamin D deficiency [45,51].

In conclusion, the 25(OH)D/24,25(OH)2D ratio is an unambiguous marker for vitamin D catabolism and may identify patients with hypercalcaemia secondary to CYP24A1 mutations, such as patients with IIH.

3.4. Other Metabolites

Beyond 25(OH)D, 1,25(OH)2D and 24,25(OH)2D many more vitamin D metabolites have been identified, yet these are scarcely measured. With the current state of techniques, many of the metabolites circulating at concentrations below that of 1,25(OH)2D will be unquantifiable and the value of these metabolites for diagnostics remains elusive. Nevertheless, future studies may find ways of detecting and using these metabolites to provide new diagnostic tools in the years to come.

4. How: Importance of the Choice of Method

4.1. 25(OH)D

25(OH)D can be measured in many different ways, yet two techniques dominate: automated immunoassay and liquid chromatography coupled to tandem-mass spectrometry (LC-MS/MS). According to the Vitamin D External Quality Assessment Scheme (DEQAS), overseeing method comparability across 54 countries, in October 2017, ~76% of the 871 participating laboratories used an automated immunoassay to measure their 25(OH)D, while ~18% used LC-MS/MS, ~3% used a manual immunoassay and ~2% used HPLC. During recent years, several studies addressed the limitations of the automated, and less frequently the manual immunoassays, when measuring in patients [52,53,54,55,56,57].

While in healthy individuals, the assays correlate nicely with the standardised LC-MS/MS method, measuring 25(OH)D in patient groups has revealed huge deviations [52,55,56,58]. This brings to light some of the major issues with the automated and manual immunoassays. First, the lack of sample preparation in the automated immunoassays allows for the emergence of severe interferences from miscellaneous origins. Differing concentrations of DBP, which are greatly affected in certain populations, such as in pregnant women, intensive care patients and patients with liver failure, may be a common problem affecting results [55,58,59].

Similarly, the automated immunoassays often have incomprehensible difficulties measuring 25(OH)D in haemodialysis patients and osteoporotic patients [52,55,57]. Unlike with the automated immunoassays, sample preparation for the HPLC, manual immunoassays and LC-MS/MS methods is adaptable and can be optimised to reduce any adverse effects that varying DBP concentrations or other contributing factors may bring. A second origin of bias for both the automated and manual immunoassays is related to the specificity of the used antibodies.

As mentioned before, 25(OH)D may be present in one of two forms, 25(OH)D2 or 25(OH)D3. Immunoassays are generally not able to distinguish the two, and report these together as total 25(OH)D. As the antibodies in the immunoassay do not bind 25(OH)D2 to a similar extent as they bind 25(OH)D3, this leads to the under- or over-estimation of total 25(OH)D [60,61,62,63,64]. Alarmingly, many automated immunoassay manufacturers report considerably different cross-reactivity percentages for 25(OH)D2 compared to the observed values by independent researchers [65,66].

This is particularly problematic in countries were supplementing with vitamin D2 is more common, for example the USA. On the contrary, LC-MS/MS has no problem measuring 25(OH)D2 alongside 25(OH)D3, as the mass difference of 12 Da is easily separated by mass spectrometry. Another inherent specificity problem for the assays using antibodies, is cross-reactivity with other vitamin D metabolites. 24,25(OH)2D3, present in about 10–15% of the 25(OH)D concentration, has proven to greatly impact immunoassays and produces falsely high results [51,67,68].

Similar to 25(OH)D2, 24,25(OH)2D3, has a different mass to 25(OH)D3 and poses no threat to the reliability of LC-MS/MS methods [67]. Epi-25(OH)D, the result of epimerisation of 25(OH)D, with levels that are highest in neonates up to one year of age and present in most adults at about 9% of 25(OH)D, does not influence the results of immunoassays, as antibodies do not recognise it [61,69,70].

Many LC-MS/MS assays, on the other hand, experience difficulties distinguishing the two epimers due to their equal mass and their similar affinity for most LC columns, resulting in an overestimation, and potential misclassification, of total 25(OH)D [61,69,71,72]. Several LC-MS/MS assays now use non-C18 columns enabling them to chromatographically separate the epimer and measure it independently of 25(OH)D, despite the identical masses [45,68,73,74,75,76].

When the first LC-MS/MS methods for 25(OH)D made their entry, DEQAS reported unflatteringly high interlaboratory differences in the measurement of 25(OH)D. Carter and Jones showed these differences were often attributable to the use of in-house calibrated standards, and significantly abated after the use of a shared standard [77]. Indeed, another study showed LC-MS/MS methods for 25(OH)D generally correlated nicely and small biases originated from differences in calibration procedures [78]. Thanks to the Vitamin D Standardization Program (VDSP) and the target value DEQAS now provides for participants, laboratories operating miscalibrated LC-MS/MS methods have the possibility to standardise their methods using the reference measurement procedure, which is crucial for their performance.

In earlier years, automated immunoassays had largely replaced manual assays with their easy operation and higher throughput. However, all the aforementioned flaws of the immunoassays that were brought to light in certain patient groups, have now tipped the scales in favour of the LC-MS/MS. Today, LC-MS/MS is slowly replacing automated immunoassays in clinical laboratories. Due to the necessity of more complex and expensive equipment and highly skilled technicians, most of the smaller laboratories still depend on the manual and automated immunoassays.

Manual immunoassays may still be well-suited for 25(OH)D measurement in patient groups where adequate sample preparation resolves the specificity issues of the technique. Automated immunoassays may still be suitable for the determination of 25(OH)D concentrations in large cohorts of healthy individuals, where interferences and supplementation are less frequent. We must conclude however, that measuring 25(OH)D in a clinical setting benefits greatly from the transition from automated immunoassays to LC-MS/MS. Still, attention to the specifications and quality of LC-MS/MS methods is advised.

Particular specifications, such as separately quantifying epi-25(OH)D3 in neonates, may be crucial. Standardisation and the resulting good agreement with the DEQAS target value or performance within the VDSP defines high quality methods. Without data on method agreement, DEQAS performance or standardisation, the quality and suitability of a method is indefinable and the possibility of misclassification exists.

Of note, a few laboratories still run HPLC methods for their 25(OH)D determination. While most of the advantages of LC-MS/MS over immunoassays also hold true for HPLC, mass spectrometers have largely replaced the UV detectors used in combination with HPLC, for their superior sensitivity and specificity. The advantages and disadvantages of today’s two most widely used techniques, immunoassays and LC-MS/MS for 25(OH)D measurement are summarised in Table 1.

All things considered, LC-MS/MS is the preferred technique for 25(OH)D measurement in patients, without the knowledge of any present interferences that might hinder its determination. The use of immunoassays is not advised in specific patient groups, including IC, haemodialysis, osteoporotic and liver failure patients, pregnant women, neonates and individuals on D2 supplementation, and caution is warranted in unstudied patient groups.

4.2. 1,25(OH)2D

As a result of the very low concentrations of circulating 1,25(OH)2D and the specialised circumstances under which its analysis is deemed necessary, fewer laboratories conduct this measurement. Of the 165 methods that participated in the DEQAS distribution of October 2017, ~75% of laboratories used an automated immunoassay to measure 1,25(OH)2D, ~17% used a manual immunoassay and ~9% used LC-MS/MS. Similar to measuring 25(OH)D, the methods for measuring 1,25(OH)2D each have their advantages and disadvantages (Table 1), making the selection of one of them difficult and relevant.

Previously, the field of 1,25(OH)2D measurement was dominated by radio-immunoassays. These assays often suffered from substantial cross-reactivity with other vitamin D metabolites and were unable to produce evincive results [79,80]. In the case of the 1,25(OH)2D assays, the newest automated immunoassays perform similarly to LC-MS/MS and no apparent specificity problem exists. Here, the overall unaccountable lack of good correlations between assays on all platforms is most problematic [17,81,82].

Without the presence of a reference method, identifying the methods that deviate is very difficult, if not impossible. A recently developed automated immunoassay shows good correlations to some of the LC-MS/MS methods that include an immunopurification step in their sample preparation, while lesser correlations are found with others that do not [82,83,84]. LC-MS/MS methods without immunopurification included in their sample preparation might suffer from isobaric interferences, such as 1β-25-dihydroxyvitamin D3, which would not be co-captured by the antibodies in the automated immunoassay [85].

Additionally, as with 25(OH)D, differences in calibration procedures are a likely cause of deviations and methods would substantially benefit from a target value provided by DEQAS and subsequent standardisation.

While immunoassays are quite easily capable of measuring very low concentrations of 1,25(OH)2D due to the inherent amplifying nature of the technique, LC-MS/MS assays struggle gaining enough sensitivity to accurately measure in the lower ranges of physiological concentrations. One way to overcome this is the use of more sophisticated chromatography. By making use of a 2D chromatography system, background noise is reduced and befouling of the MS instrument diminished. It comprises of two parallel connected columns. Only when the analytes of interest elute from the first column is it connected to the second column.

Before and after this moment, flow is directed towards a waste. Another option is derivatisation of the vitamin D molecule. By chemical transformation of the molecule into something more easily ionised, sensitivity is improved. For the vitamin D molecules, several derivatisation agents are available. Most of them are based on the same Diels–Alder reaction taking place on the diene structure adjacent to the A-ring in the backbone of vitamin D. The diophenile molecules differ in the groups attached to their triazole backbone.

The two most widely used derivatisation agents are PTAD and Amplifex.

As expected, the assays using a derivatisation agent generally report lower limits of quantification (LOQs), with levels up to 2.5 pmol/L [17,75,80,86,87,88]. The assays not using derivatisation require more elaborative sample preparation (immunopurification), increased sample volume (>0.5 mL), more sophisticated LC-MS/MS systems (µLC or 2D chromatography) or do not reach desirable LOQs [74,88,89,90,91,92]. The lowest LOQs have been reached using immunopurification followed by PTAD derivatisation [17,80].

Using Amplifex has the advantage of not requiring an immunopurification step, which makes it possible to include additional vitamin D metabolites aside from 1,25(OH)D3 and 1,25(OH)D2, but impedes the chromatographic separation of epimers.

It is difficult to convincingly argue in favour of one technique over the other in the case of 1,25(OH)2D. When separate quantification of 1,25(OH)2D3 and 1,25(OH)2D2 is preferable, in countries with vitamin D2 supplementation, LC-MS/MS is the only option. Notwithstanding, in the case of 25(OH)D, standardisation and subsequent amelioration of LC-MS/MS methods exposed the pitfalls of the immunoassays. With the 1,25(OH)2D methods, a similar chain of insights may lay ahead.

Without the availability of a reference method, though, standardisation is not an option and identifying the origin of biases between methods and prescribing necessities for 1,25(OH)2D measurements in clinical diagnostics is difficult. Nonetheless, three things are evident from the available data. First, there is no incontestable difference of outcome between the newest automated immunoassays and LC-MS/MS. Second, when using a dedicated LC-MS/MS method for 1,25(OH)2D, incorporation of immunopurification in the sample preparation generally leads to a method with greater sensitivity and specificity.

Third, when measuring multiple vitamin D metabolites at the same time, immunopurification is not applicable and LC conditions and sensitivity optimisation need considerable attention to accurately measure each metabolite at endogenous concentrations.

4.3. 24,25(OH)2D

Several laboratories have developed methods for the quantification of 24,25(OH)2D. Those participating in the DEQAS distribution all use LC-MS/MS, despite the existence of a 24,25(OH)2D radio-immunoassay. The advantages and disadvantages of LC-MS/MS methods are depicted in Table 1. Most of them, but not all, use an isotopically labelled standard to aid them in accurate measurement. The methods measuring 24,25(OH)2D have usually incorporated additional vitamin D metabolites in their analysis. One thing to consider is the application of a derivatisation agent. 24,25(OH)2D is present at about 10% of the 25(OH)D concentration.

As a result, similar to 1,25(OH)2D, it is not easily measured by our current high-end LC-MS/MS systems without extra efforts to improve sensitivity. One of the options is derivatising the metabolite with a derivatisation agent, like PTAD, DMEQ-TAD or Amplifex [45,75,88,93]. This increases sensitivity considerably, yet unfortunately PTAD thwarts the separate quantification of epi-25(OH)D3. Without derivatisation, higher LOQs are reported, additional efforts in other areas have to be undertaken to acquire similar LOQs, or higher sample volumes are required [44,68,73,74,86,94,95].

A candidate reference method was published by Tai and Nelson with high precision and accuracy [96]. Using five serum samples identified by the NIST as Standard Reference Material (SRM) and 30 samples from the DEQAS distribution, the candidate reference method and five laboratories routinely measuring 24,25(OH)2D assessed their comparability [97]. Mean biases of the participants ranged from −15% to 36% for the SRM samples and from 6% to 15% for the DEQAS samples. A significant SD of the mean bias for some of the laboratories indicated room for precision improvement.

Overall, significant biases with the candidate reference method for 24,25(OH)2D shows we are long from uniform measurement of the metabolite. This is especially problematic when measuring the 25(OH)D/24,25(OH)2D ratio as it becomes unreliable and inaccurate when either one of the two methods is unstandardised. Further efforts for standardisation, including the availability of the SRMs and provision of a target value by DEQAS, are a necessity for uniform measurement and interpretation.

The measurement of 24,25(OH)2D remains mainly research driven instead of clinical, and data on method comparison is scarce. In consequence, designating high quality methods is difficult. In the coming years, 24,25(OH)2D will probably be more widely incorporated in clinical laboratories and attention to standardisation will lead to its solid anchoring within vitamin D metabolism diagnostics.

4.4. Other Metabolites

A number of the aforementioned LC-MS/MS methods measure additional metabolites. Where, in the case of epi-25(OH)D3, the value of measurement in neonates is well established, for other metabolites, such as 4β,25(OH)2D3, 23(R),25(OH)2D3 and 24(OH)D, the significance is not clear. These metabolites are usually incorporated in LC-MS/MS methods after being identified as an interference, and subsequently chromatographically separated and quantified. To date, a real reason to quantitatively measure these additional vitamin D metabolites is lacking, and nothing can be stated about the importance of the choice of method.

5. Discussion and Conclusions

While the reasons for measuring 25(OH)D have often been described, the value of measuring its metabolites, 1,25(OH)2D and especially 24,25(OH)2D, remains largely unappreciated. In short, indications where measurement of 1,25(OH)2D may contribute to diagnosis or aid in monitoring treatment include conditions where production of 1,25(OH)2D is heavily disturbed, resulting in either a shortage of 1,25(OH)2D, such as in 1α-hydroxylase deficiency, or an overabundance of 1,25(OH)2D, such as in hereditary vitamin D-resistant rickets, sarcoidosis, tuberculosis, rheumatoid arthritis, inflammatory bowel disease and lymphoproliferative diseases. 1,25(OH)2D also helps to identify the hypophosphatemic syndromes mediated by FGF23, including XLH, ADHR, ARHR and TIO.

Measuring 24,25(OH)2D enables identification of CYP24A1 mutations leading to impaired catabolism of the hormone and associated hypercalcaemia, such as in IIH.

For determination of these analytes in the clinical laboratory, we have long relied on immunoassays. The automation of assays increased throughput and reduced complexity. However, the emergence of LC-MS/MS has provided us with new insight into their limitations. Yes, automated immunoassays may be fast, less laborious and sensitive, but the superiority of LC-MS/MS assays regarding specificity is evident and has revealed some serious issues that hinder immunoassays from producing reliable results in certain patient groups. The problems that may arise when selecting a method without the necessary characteristics are less obvious but no less important.

In a number of patient groups, including pregnant women, intensive care patients, patients with liver failure, haemodialysis patients and osteoporotic patients, automated immunoassays have proven unreliable. Measuring 25(OH)D in these patients with an automated immunoassay is therefore not advised. As there is usually no prior knowledge of the possible interferences in a patient sample, LC-MS/MS is the preferred method for 25(OH)D determination in patient diagnostics.

All in all, measuring vitamin D metabolism has greatly benefitted from the entry of LC-MS/MS in clinical laboratories. It enabled us to drastically improve specificity and accuracy, and provided us with the ability to co-measure multiple metabolites simultaneously. It has already proven very useful in the diagnosis of numerous conditions and new generations of more sensitive LC-MS/MS instruments will enable us to further meticulously study, to date unexplained, vitamin D metabolism-related conditions. If immunoassay manufacturers succeed in improving their newer generations of automated immunoassays, as has happened with the 2nd generation testosterone immunoassays, they may overcome the problems they face today and prove reliable in patient diagnostics [98].

By the same token, the disadvantages of today’s LC-MS/MS instruments, being quite laborious, may be resolved by more easy to use instruments and the introduction of fully automated LC-MS/MS systems. Additionally, further efforts in the standardisation of assays are needed to raise the overall quality of these methods and provide clinicians with reliable results.

Conclusively, measuring vitamin D metabolites is, and will be important, to diagnose a number of different conditions. Attention to the when, the what and the how of measuring vitamin D metabolism greatly benefits diagnostic and research power.

Acknowledgments

The authors thank Evelyn Jonkman for language editing.

Author Contributions

N.F.D. drafted a first version of the manuscript. M.T.A., P.L., R.T.d.J., M.G.V., R.d.J. and A.C.H. critically reviewed the manuscript and contributed to the final version.

Conflicts of Interest

The authors declare no conflict of interest.

References

1. Heaney R.P. Recker R.R. Grote J. Horst R.L. Armas L.A. Vitamin D(3) is more potent than vitamin D(2) in humans J. Clin. Endocrinol. Metab. 2011 96 E447 E452 10.1210/jc.2010-2230 21177785
2. Kamao M. Tatematsu S. Hatakeyama S. Sakaki T. Sawada N. Inouye K. Ozono K. Kubodera N. Reddy G.S. Okano T. C-3 epimerization of vitamin D3 metabolites and further metabolism of C-3 epimers: 25-hydroxyvitamin D3 is metabolized to 3-epi-25-hydroxyvitamin D3 and subsequently metabolized through C-1alpha or C-24 hydroxylation J. Biol. Chem. 2004 279 15897 15907 10.1074/jbc.M311473200 14757768
3. Saito H. Kusano K. Kinosaki M. Ito H. Hirata M. Segawa H. Miyamoto K. Fukushima N. Human fibroblast growth factor-23 mutants suppress Na+-dependent phosphate co-transport activity and 1alpha,25-dihydroxyvitamin D3 production J. Biol. Chem. 2003 278 2206 2211 10.1074/jbc.M207872200 12419819
4. Bikle D. Nonclassic actions of vitamin D J. Clin. Endocrinol. Metab. 2009 94 26 34 10.1210/jc.2008-1454 18854395 PMC2630868
5. Liu P.T. Stenger S. Li H. Wenzel L. Tan B.H. Krutzik S.R. Ochoa M.T. Schauber J. Wu K. Meinken C. Toll-like receptor triggering of a vitamin D-mediated human antimicrobial response Science 2006 311 1770 1773 10.1126/science.1123933 16497887
6. Lips P. Relative value of 25(OH)D and 1,25(OH)2D measurements J. Bone Miner. Res. Off. J. Am. Soc. Bone Miner. Res. 2007 22 1668 1671 10.1359/jbmr.070716 17645404
7. Holick M.F. Vitamin D deficiency N. Engl. J. Med. 2007 357 266 281 10.1056/NEJMra070553 17634462
8. Holick M.F. Vitamin D status: Measurement, interpretation, and clinical application Ann. Epidemiol. 2009 19 73 78 10.1016/j.annepidem.2007.12.001 18329892 PMC2665033
9. Hollis B.W. Assessment and interpretation of circulating 25-hydroxyvitamin D and 1,25-dihydroxyvitamin D in the clinical environment Endocrinol. Metab. Clin. North Am. 2010 39 271 286 10.1016/j.ecl.2010.02.012 20511051 PMC2903449
10. Bouillon R. Van Schoor N.M. Gielen E. Boonen S. Mathieu C. Vanderschueren D. Lips P. Optimal vitamin D status: A critical analysis on the basis of evidence-based medicine J. Clin. Endocrinol. Metab. 2013 98 E1283 E1304 10.1210/jc.2013-1195 23922354
11. Ross A.C. Manson J.E. Abrams S.A. Aloia J.F. Brannon P.M. Clinton S.K. Durazo-Arvizu R.A. Gallagher J.C. Gallo R.L. Jones G. The 2011 report on dietary reference intakes for calcium and vitamin D from the institute of medicine: What clinicians need to know J. Clin. Endocrinol. Metab. 2011 96 53 58 10.1210/jc.2010-2704 21118827 PMC3046611
12. Manson J.E. Brannon P.M. Rosen C.J. Taylor C.L. Vitamin D deficiency—Is there really a pandemic? N. Engl. J. Med. 2016 375 1817 1820 10.1056/NEJMp1608005 27959647
13. Bischoff-Ferrari H.A. Giovannucci E. Willett W.C. Dietrich T. Dawson-Hughes B. Estimation of optimal serum concentrations of 25-hydroxyvitamin d for multiple health outcomes Am. J. Clin. Nutr. 2006 84 18 28 10.1093/ajcn/84.1.18 16825677
14. Norman A.W. Bouillon R. Whiting S.J. Vieth R. Lips P. 13th workshop consensus for vitamin D nutritional guidelines J. Steroid Biochem. Mol. Biol. 2007 103 204 205 10.1016/j.jsbmb.2006.12.071 17234402 PMC1906737
15. Ross A.C. The 2011 report on dietary reference intakes for calcium and vitamin D Public Health Nutr. 2011 14 938 939 10.1017/S1368980011000565 21492489
16. Holick M.F. Binkley N.C. Bischoff-Ferrari H.A. Gordon C.M. Hanley D.A. Heaney R.P. Murad M.H. Weaver C.M. Evaluation, treatment, and prevention of vitamin D deficiency: An endocrine society clinical practice guideline J. Clin. Endocrinol. Metab. 2011 96 1911 1930 10.1210/jc.2011-0385 21646368
17. Dirks N.F. Martens F. Vanderschueren D. Billen J. Pauwels S. Ackermans M.T. Endert E. Heijer M.D. Blankenstein M.A. Heijboer A.C. Determination of human reference values for serum total 1,25-dihydroxyvitamin D using an extensively validated 2D ID-UPLC-MS/MS method J. Steroid Biochem. Mol. Biol. 2016 164 127 133 10.1016/j.jsbmb.2015.12.003 26690787
18. Zalewski A. Ma N.S. Legeza B. Renthal N. Fluck C.E. Pandey A.V. Vitamin D-dependent rickets type 1 caused by mutations in CYP27B1 affecting protein interactions with adrenodoxin J. Clin. Endocrinol. Metab. 2016 101 3409 3418 10.1210/jc.2016-2124 27399352
19. Francis F. Hennig S. Korn B. Reinhardrdt R. de Jong P. Poustka A. Lehrach H. Rowe P.S.N. Goulding J.N. Summerfield T. A gene (PEX) with homologies to endopeptidases is mutated in patients with x-linked hypophosphatemic rickets. The HYP consortium Nat. Genet. 1995 11 130 136 10.1038/ng1095-130 7550339
20. Imel E.A. DiMeglio L.A. Hui S.L. Carpenter T.O. Econs M.J. Treatment of x-linked hypophosphatemia with calcitriol and phosphate increases circulating fibroblast growth factor 23 concentrations J. Clin. Endocrinol. Metab. 2010 95 1846 1850 10.1210/jc.2009-1671 20157195 PMC2853995
21. Chong W.H. Molinolo A.A. Chen C.C. Collins M.T. Tumor-induced osteomalacia Endocr.-Relat. Cancer 2011 18 R53 R77 10.1530/ERC-11-0006 21490240 PMC3433741
22. Nagata Y. Imanishi Y. Ishii A. Kurajoh M. Motoyama K. Morioka T. Naka H. Mori K. Miki T. Emoto M. Evaluation of bone markers in hypophosphatemic rickets/osteomalacia Endocrine 2011 40 315 317 10.1007/s12020-011-9512-z 21822687
23. Consortium A. Autosomal dominant hypophosphataemic rickets is associated with mutations in FGF23 Nat. Genet. 2000 26 345 348 11062477 10.1038/81664
24. White K.E. Carn G. Lorenz-Depiereux B. Benet-Pages A. Strom T.M. Econs M.J. Autosomal-dominant hypophosphatemic rickets (ADHR) mutations stabilize FGF-23 Kidney Int. 2001 60 2079 2086 10.1046/j.1523-1755.2001.00064.x 11737582
25. Levy-Litan V. Hershkovitz E. Avizov L. Leventhal N. Bercovich D. Chalifa-Caspi V. Manor E. Buriakovsky S. Hadad Y. Goding J. Autosomal-recessive hypophosphatemic rickets is associated with an inactivation mutation in the ENPP1 gene Am. J. Hum. Genet. 2010 86 273 278 10.1016/j.ajhg.2010.01.010 20137772 PMC2820183
26. Rafaelsen S.H. Raeder H. Fagerheim A.K. Knappskog P. Carpenter T.O. Johansson S. Bjerknes R. Exome sequencing reveals FAM20c mutations associated with fibroblast growth factor 23-related hypophosphatemia, dental anomalies, and ectopic calcification J. Bone Miner. Res. 2013 28 1378 1385 10.1002/jbmr.1850 23325605
27. Riminucci M. Collins M.T. Fedarko N.S. Cherman N. Corsi A. White K.E. Waguespack S. Gupta A. Hannon T. Econs M.J. FGF-23 in fibrous dysplasia of bone and its relationship to renal phosphate wasting J. Clin. Investig. 2003 112 683 692 10.1172/JCI18399 12952917 PMC182207
28. Farrow E.G. Davis S.I. Mooney S.D. Beighton P. Mascarenhas L. Gutierrez Y.R. Pitukcheewanont P. White K.E. Extended mutational analyses of FGFR1 in osteoglophonic dysplasia Am. J. Med. Genet. Part A 2006 140 537 539 10.1002/ajmg.a.31106 16470795
29. Avitan-Hersh E. Tatur S. Indelman M. Gepstein V. Shreter R. Hershkovitz D. Brick R. Bergman R. Tiosano D. Postzygotic HRAS mutation causing both keratinocytic epidermal nevus and thymoma and associated with bone dysplasia and hypophosphatemia due to elevated FGF23 J. Clin. Endocrinol. Metab. 2014 99 E132 E136 10.1210/jc.2013-2813 24243633
30. Gupta A. Dwivedi A. Patel P. Gupta S. Hypophosphatemic osteomalacia in von recklinghausen neurofibromatosis: Case report and literature review Indian J. Radiol. Imaging 2015 25 63 66 10.4103/0971-3026.150155 25709169 PMC4329691
31. Brownstein C.A. Adler F. Nelson-Williams C. Iijima J. Li P. Imura A. Nabeshima Y. Reyes-Mugica M. Carpenter T.O. Lifton R.P. A translocation causing increased alpha-klotho level results in hypophosphatemic rickets and hyperparathyroidism Proc. Natl. Acad. Sci. USA 2008 105 3455 3460 10.1073/pnas.0712361105 18308935 PMC2265125
32. Brown W.W. Juppner H. Langman C.B. Price H. Farrow E.G. White K.E. McCormick K.L. Hypophosphatemia with elevations in serum fibroblast growth factor 23 in a child with jansen’s metaphyseal chondrodysplasia J. Clin. Endocrinol. Metab. 2009 94 17 20 10.1210/jc.2008-0220 18854401 PMC2630869
33. Chanakul A. Zhang M.Y. Louw A. Armbrecht H.J. Miller W.L. Portale A.A. Perwad F. FGF-23 regulates CYP27B1 transcription in the kidney and in extra-renal tissues PLoS ONE 2013 8 e72816 10.1371/journal.pone.0072816 24019880 PMC3760837
34. Lorenz-Depiereux B. Benet-Pages A. Eckstein G. Tenenbaum-Rakover Y. Wagenstaller J. Tiosano D. Gershoni-Baruch R. Albers N. Lichtner P. Schnabel D. Hereditary hypophosphatemic rickets with hypercalciuria is caused by mutations in the sodium-phosphate cotransporter gene SLC34A3 Am. J. Hum. Genet. 2006 78 193 201 10.1086/499410 16358215 PMC1380229
35. Tieder M. Modai D. Shaked U. Samuel R. Arie R. Halabe A. Maor J. Weissgarten J. Averbukh Z. Cohen N. “Idiopathic” hypercalciuria and hereditary hypophosphatemic rickets. Two phenotypical expressions of a common genetic defect N. Engl. J. Med. 1987 316 125 129 10.1056/NEJM198701153160302 3796683
36. Goto S. Fujii H. Kono K. Watanabe K. Nakai K. Nishi S. Serum FGF23 levels may not be associated with serum phosphate and 1,25-dihydroxyvitamin D levels in patients with fanconi syndrome–induced hypophosphatemia Clin. Kidney J. 2016 9 677 681 10.1093/ckj/sfw086 27679714 PMC5036911
37. Adams J.S. Hewison M. Extrarenal expression of the 25-hydroxyvitamin d-1-hydroxylase Arch. Biochem. Biophys. 2012 523 95 102 10.1016/j.abb.2012.02.016 22446158 PMC3361592
38. Donovan P.J. Sundac L. Pretorius C.J. d’Emden M.C. McLeod D.S. Calcitriol-mediated hypercalcemia: Causes and course in 101 patients J. Clin. Endocrinol. Metab. 2013 98 4023 4029 10.1210/jc.2013-2016 23979953
39. Abreu M.T. Kantorovich V. Vasiliauskas E.A. Gruntmanis U. Matuk R. Daigle K. Chen S. Zehnder D. Lin Y.C. Yang H. Measurement of vitamin D levels in inflammatory bowel disease patients reveals a subset of crohn’s disease patients with elevated 1,25-dihydroxyvitamin D and low bone mineral density Gut 2004 53 1129 1136 10.1136/gut.2003.036657 15247180 PMC1774134
40. Karakelides H. Geller J.L. Schroeter A.L. Chen H. Behn P.S. Adams J.S. Hewison M. Wermers R.A. Vitamin D-mediated hypercalcemia in slack skin disease: Evidence for involvement of extrarenal 25-hydroxyvitamin D 1alpha-hydroxylase J. Bone Miner. Res. Off. J. Am. Soc. Bone Miner. Res. 2006 21 1496 1499 10.1359/jbmr.060608 16939409
41. Jones G. Strugnell S.A. DeLuca H.F. Current understanding of the molecular actions of vitamin D Physiol. Rev. 1998 78 1193 1231 10.1152/physrev.1998.78.4.1193 9790574
42. St-Arnaud R. Glorieux F.H. 24,25-dihydroxyvitamin D—Active metabolite or inactive catabolite? Endocrinology 1998 139 3371 3374 10.1210/endo.139.8.6185 9681484
43. St-Arnaud R. Novel findings about 24,25-dihydroxyvitamin D: An active metabolite? Curr. Opin. Nephrol. Hypertens. 1999 8 435 441 10.1097/00041552-199907000-00007 10491738
44. Wagner D. Hanwell H.E. Schnabl K. Yazdanpanah M. Kimball S. Fu L. Sidhom G. Rousseau D. Cole D.E. Vieth R. The ratio of serum 24,25-dihydroxyvitamin D(3) to 25-hydroxyvitamin D(3) is predictive of 25-hydroxyvitamin D(3) response to vitamin D(3) supplementation J. Steroid Biochem. Mol. Biol. 2011 126 72 77 10.1016/j.jsbmb.2011.05.003 21605672
45. Kaufmann M. Gallagher J.C. Peacock M. Schlingmann K.P. Konrad M. DeLuca H.F. Sigueiro R. Lopez B. Mourino A. Maestro M. Clinical utility of simultaneous quantitation of 25-hydroxyvitamin D and 24,25-dihydroxyvitamin D by LC-MS/MS involving derivatization with DMEQ-TAD J. Clin. Endocrinol. Metab. 2014 99 2567 2574 10.1210/jc.2013-4388 24670084 PMC4079315
46. Schlingmann K.P. Kaufmann M. Weber S. Irwin A. Goos C. John U. Misselwitz J. Klaus G. Kuwertz-Broking E. Fehrenbach H. Mutations in CYP24A1 and idiopathic infantile hypercalcemia N. Engl. J. Med. 2011 365 410 421 10.1056/NEJMoa1103864 21675912
47. Dinour D. Beckerman P. Ganon L. Tordjman K. Eisenstein Z. Holtzman E.J. Loss-of-function mutations of CYP24A1, the vitamin D 24-hydroxylase gene, cause long-standing hypercalciuric nephrolithiasis and nephrocalcinosis J. Urol. 2013 190 552 557 10.1016/j.juro.2013.02.3188 23470222
48. Sayers J. Hynes A.M. Srivastava S. Dowen F. Quinton R. Datta H.K. Sayer J.A. Successful treatment of hypercalcaemia associated with a CYP24A1 mutation with fluconazole Clin. Kidney J. 2015 8 453 455 10.1093/ckj/sfv028 26251716 PMC4515887
49. Nesterova G. Malicdan M.C. Yasuda K. Sakaki T. Vilboux T. Ciccone C. Horst R. Huang Y. Golas G. Introne W. 1,25-(OH)2D-24 hydroxylase (CYP24A1) deficiency as a cause of nephrolithiasis Clin. J. Am. Soc. Nephrol. CJASN 2013 8 649 657 10.2215/CJN.05360512 23293122 PMC3613951
50. Molin A. Baudoin R. Kaufmann M. Souberbielle J.C. Ryckewaert A. Vantyghem M.C. Eckart P. Bacchetta J. Deschenes G. Kesler-Roussey G. CYP24A1 mutations in a cohort of hypercalcemic patients: Evidence for a recessive trait J. Clin. Endocrinol. Metab. 2015 100 E1343 E1352 10.1210/jc.2014-4387 26214117
51. Cashman K.D. Hayes A. Galvin K. Merkel J. Jones G. Kaufmann M. Hoofnagle A.N. Carter G.D. Durazo-Arvizu R.A. Sempos C.T. Significance of serum 24,25-dihydroxyvitamin D in the assessment of vitamin D status: A double-edged sword? Clin. Chem. 2015 61 636 645 10.1373/clinchem.2014.234955 25710460
52. Depreter B. Heijboer A.C. Langlois M.R. Accuracy of three automated 25-hydroxyvitamin D assays in hemodialysis patients Clin. Chim. Acta Int. J. Clin. Chem. 2013 415 255 260 10.1016/j.cca.2012.10.056 23159781
53. Ong L. Saw S. Sahabdeen N.B. Tey K.T. Ho C.S. Sethi S.K. Current 25-hydroxyvitamin D assays: Do they pass the test? Clin. Chim. Acta Int. J. Clin. Chem. 2012 413 1127 1134 10.1016/j.cca.2012.03.009 22465235
54. Farrell C.J. Martin S. McWhinney B. Straub I. Williams P. Herrmann M. State-of-the-art vitamin D assays: A comparison of automated immunoassays with liquid chromatography-tandem mass spectrometry methods Clin. Chem. 2012 58 531 542 10.1373/clinchem.2011.172155 22230812
55. Heijboer A.C. Blankenstein M.A. Kema I.P. Buijs M.M. Accuracy of 6 routine 25-hydroxyvitamin D assays: Influence of vitamin d binding protein concentration Clin. Chem. 2012 58 543 548 10.1373/clinchem.2011.176545 22247500
56. Wise S.A. Phinney K.W. Tai S.S. Camara J.E. Myers G.L. Durazo-Arvizu R. Tian L. Hoofnagle A.N. Bachmann L.M. Young I.S. Baseline assessment of 25-hydroxyvitamin D assay performance: A vitamin D standardization program (VDSP) interlaboratory comparison study J. AOAC Int. 2017 100 1244 1252 10.5740/jaoacint.17-0258 28822355
57. Cavalier E. Lukas P. Bekaert A.C. Peeters S. Le Goff C. Yayo E. Delanaye P. Souberbielle J.C. Analytical and clinical evaluation of the new Fujirebio Lumipulse® G non-competitive assay for 25(OH)-vitamin D and three immunoassays for 25(OH)D in healthy subjects, osteoporotic patients, third trimester pregnant women, healthy African subjects, hemodialyzed and intensive care patients Clin. Chem. Lab. Med. 2016 54 1347 1355 26741345 10.1515/cclm-2015-0923
58. Elsenberg E. Ten Boekel E. Huijgen H. Heijboer A.C. Standardization of automated 25-hydroxyvitamin D assays: How successful is it? Clin. Biochem. 2017 50 1126 1130 10.1016/j.clinbiochem.2017.06.011 28668468
59. Freeman J. Wilson K. Spears R. Shalhoub V. Sibley P. Influence of vitamin d binding protein on accuracy of 25-hydroxyvitamin D measurement using the advia centaur vitamin d total assay Int. J. Endocrinol. 2014 2014 691679 25045351 10.1155/2014/691679 PMC4089903
60. Hsu S.A. Soldo J. Gupta M. Evaluation of two automated immunoassays for 25-OH vitamin D: Comparison against LC-MS/MS J. Steroid Biochem. Mol. Biol. 2013 136 139 145 10.1016/j.jsbmb.2012.11.005 23202147
61. Janssen M.J. Wielders J.P. Bekker C.C. Boesten L.S. Buijs M.M. Heijboer A.C. van der Horst F.A. Loupatty F.J. van den Ouweland J.M. Multicenter comparison study of current methods to measure 25-hydroxyvitamin D in serum Steroids 2012 77 1366 1372 10.1016/j.steroids.2012.07.013 22925701
62. Chouiali A. Mallet P.L. Fink G. Biron S. Langlois M.F. Comparison of two methods for measuring 25-OH vitamin D in the follow-up of patients after bilio-pancreatic diversion bariatric surgery Clin. Biochem. 2017 50 210 216 10.1016/j.clinbiochem.2016.11.010 27863211
63. Brock A.T. Strickland S.W. Bazydlo L.A.L. Haverstick D.M. An underestimation of 25-OH vitamin D in patients with renal disease by the abbott architect immunoassay J. Appl. Lab. Med. AACC Publ. 2017 2 449 451 10.1373/jalm.2017.024331 33636858
64. Shu I. Pina-Oviedo S. Quiroga-Garza G. Meng Q.H. Wang P. Influence of vitamin D2 percentage on accuracy of 4 commercial total 25-hydroxyvitamin D assays Clin. Chem. 2013 59 1273 1275 10.1373/clinchem.2013.206128 23695296
65. Tolan N.V. Yoon E.J. Brady A.R. Horowitz G.L. Price of high-throughput 25-hydroxyvitamin D immunoassays: Frequency of inaccurate results J. Appl. Lab. Med. AACC Publ. 2017 2 10.1373/jalm.2017.024323 33636826
66. Le Goff C. Peeters S. Crine Y. Lukas P. Souberbielle J.C. Cavalier E. Evaluation of the cross-reactivity of 25-hydroxyvitamin D2 on seven commercial immunoassays on native samples Clin. Chem. Lab. Med. 2012 50 2031 2032 10.1515/cclm-2012-0164 23096759
67. Carter G.D. Jones J.C. Shannon J. Williams E.L. Jones G. Kaufmann M. Sempos C. 25-hydroxyvitamin D assays: Potential interference from other circulating vitamin D metabolites J. Steroid Biochem. Mol. Biol. 2016 164 134 138 10.1016/j.jsbmb.2015.12.018 26718874
68. Dowling K.G. Hull G. Sundvall J. Lamberg-Allardt C. Cashman K.D. Improved accuracy of an tandem liquid chromatography-mass spectrometry method measuring 24R,25-dihydroxyvitamin D3 and 25-hydroxyvitamin D metabolites in serum using unspiked controls and its application to determining cross-reactivity of a chemiluminescent microparticle immunoassay J. Chromatogr. A 2017 1497 102 109 28372841 10.1016/j.chroma.2017.03.058
69. Burdette C.Q. Camara J.E. Nalin F. Pritchett J. Sander L.C. Carter G.D. Jones J. Betz J.M. Sempos C.T. Wise S.A. Establishing an accuracy basis for the vitamin D external quality assessment scheme (DEQAS) J. AOAC Int. 2017 100 1277 1287 10.5740/jaoacint.17-0306 28847346
70. Ooms N. van Daal H. Beijers A.M. Gerrits G.P. Semmekrot B.A. van den Ouweland J.M. Time-course analysis of 3-epi-25-hydroxyvitamin D3 shows markedly elevated levels in early life, particularly from vitamin D supplementation in preterm infants Pediatr. Res. 2016 79 647 653 10.1038/pr.2015.251 26709675
71. Van den Ouweland J.M. Beijers A.M. van Daal H. Overestimation of 25-hydroxyvitamin D3 by increased ionisation efficiency of 3-epi-25-hydroxyvitamin D3 in LC-MS/MS methods not separating both metabolites as determined by an LC-MS/MS method for separate quantification of 25-hydroxyvitamin D3, 3-epi-25-hydroxyvitamin D3 and 25-hydroxyvitamin D2 in human serum J. Chromatogr. B Anal. Technol. Biomed. Life Sci. 2014 967 195 202 10.1016/j.jchromb.2014.07.021 25125396
72. Carter G.D. Accuracy of 25-hydroxyvitamin D assays: Confronting the issues Curr. Drug Targets 2011 12 19 28 10.2174/138945011793591608 20795940
73. Fabregat-Cabello N. Farre-Segura J. Huyghebaert L. Peeters S. Le Goff C. Souberbielle J.-C. Cavalier É. A fast and simple method for simultaneous measurements of 25(OH)D, 24,25(OH)2D and the vitamin D metabolite ratio (VMR) in serum samples by LC-MS/MS Clin. Chim. Acta 2017 473 116 123 10.1016/j.cca.2017.08.024 28842174
74. Jenkinson C. Taylor A.E. Hassan-Smith Z.K. Adams J.S. Stewart P.M. Hewison M. Keevil B.G. High throughput LC-MS/MS method for the simultaneous analysis of multiple vitamin D analytes in serum J. Chromatogr. B Anal. Technol. Biomed. Life Sci. 2016 1014 56 63 10.1016/j.jchromb.2016.01.049 26874878 PMC4801106
75. Muller M.J. Stokes C.S. Lammert F. Volmer D.A. Chemotyping the distribution of vitamin D metabolites in human serum Sci. Rep. 2016 6 21080 10.1038/srep21080 26864540 PMC4750036
76. Van den Ouweland J.M. Beijers A.M. van Daal H. Fast separation of 25-hydroxyvitamin D3 from 3-epi-25-hydroxyvitamin D3 in human serum by liquid chromatography-tandem mass spectrometry: Variable prevalence of 3-epi-25-hydroxyvitamin D3 in infants, children, and adults Clin. Chem. 2011 57 1618 1619 10.1373/clinchem.2011.170282 21914787
77. Carter G.D. Jones J.C. Use of a common standard improves the performance of liquid chromatography-tandem mass spectrometry methods for serum 25-hydroxyvitamin-D Ann. Clin. Biochem. 2009 46 79 81 10.1258/acb.2008.008135 19103962
78. Dirks N.F. Vesper H.W. van Herwaarden A.E. van den Ouweland J.M. Kema I.P. Krabbe J.G. Heijboer A.C. Various calibration procedures result in optimal standardization of routinely used 25(OH)D ID-LC-MS/MS methods Clin. Chim. Acta Int. J. Clin. Chem. 2016 462 49 54 10.1016/j.cca.2016.08.016 27570062 PMC5703036
79. Hawkes C.P. Schnellbacher S. Singh R.J. Levine M.A. 25-hydroxyvitamin D can interfere with a common assay for 1,25-dihydroxyvitamin D in vitamin D intoxication J. Clin. Endocrinol. Metab. 2015 100 2883 2889 10.1210/jc.2015-2206 26120794 PMC4524983
80. Strathmann F.G. Laha T.J. Hoofnagle A.N. Quantification of 1alpha,25-dihydroxy vitamin D by immunoextraction and liquid chromatography-tandem mass spectrometry Clin. Chem. 2011 57 1279 1285 10.1373/clinchem.2010.161174 21768219 PMC3261234
81. Kimball S.M. Vieth R. A comparison of automated methods for the quantitation of serum 25-hydroxyvitamin D and 1,25-dihydroxyvitamin D Clin. Biochem. 2007 40 1305 1310 10.1016/j.clinbiochem.2007.07.015 17825808
82. Zittermann A. Ernst J.B. Becker T. Dreier J. Knabbe C. Gummert J.F. Kuhn J. Measurement of circulating 1,25-dihydroxyvitamin D: Comparison of an automated method with a liquid chromatography tandem mass spectrometry method Int. J. Anal. Chem. 2016 2016 8501435 10.1155/2016/8501435 27127512 PMC4835639
83. Valcour A. Zierold C. Podgorski A.L. Olson G.T. Wall J.V. DeLuca H.F. Bonelli F. A novel, fully-automated, chemiluminescent assay for the detection of 1,25-dihydroxyvitamin D in biological samples J. Steroid Biochem. Mol. Biol. 2016 164 120 126 10.1016/j.jsbmb.2015.08.005 26303747
84. Miller N. Gruson D. Implementation of automated testing for 1,25-dihydroxyvitamin D: Return of experience from a core-laboratory Clin. Biochem. 2016 49 298 301 10.1016/j.clinbiochem.2015.10.017 26519091
85. Pauwels S. Jans I. Billen J. Heijboer A. Verstuyf A. Carmeliet G. Mathieu C. Maestro M. Waelkens E. Evenepoel P. 1beta,25-dihydroxyvitamin D3: A new vitamin d metabolite in human serum J. Steroid Biochem. Mol. Biol. 2017 173 341 348 10.1016/j.jsbmb.2017.02.004 28193495
86. Duan X. Weinstock-Guttman B. Wang H. Bang E. Li J. Ramanathan M. Qu J. Ultrasensitive quantification of serum vitamin D metabolites using selective solid-phase extraction coupled to microflow liquid chromatography and isotope-dilution mass spectrometry Anal. Chem. 2010 82 2488 2497 10.1021/ac902869y 20151683
87. Hedman C.J. Wiebe D.A. Dey S. Plath J. Kemnitz J.W. Ziegler T.E. Development of a sensitive LC/MS/MS method for vitamin D metabolites: 1,25 dihydroxyvitamin D2&3 measurement using a novel derivatization agent J. Chromatogr. B Anal. Technol. Biomed. Life Sci. 2014 953–954 62 67 10.1016/j.jchromb.2014.01.045 PMC4050665 24576767
88. Wang Z. Senn T. Kalhorn T. Zheng X.E. Zheng S. Davis C.L. Hebert M.F. Lin Y.S. Thummel K.E. Simultaneous measurement of plasma vitamin D(3) metabolites, including 4beta,25-dihydroxyvitamin D(3), using liquid chromatography-tandem mass spectrometry Anal. Biochem. 2011 418 126 133 10.1016/j.ab.2011.06.043 21784054 PMC3164754
89. Casetta B. Jans I. Billen J. Vanderschueren D. Bouillon R. Development of a method for the quantification of 1alpha,25(OH)2-vitamin D3 in serum by liquid chromatography tandem mass spectrometry without derivatization Eur. J. Mass Spectrom. 2010 16 81 89 10.1255/ejms.1024 20065517
90. Fang H. Yu S. Cheng Q. Cheng X. Han J. Qin X. Xia L. Jiang X. Qiu L. Determination of 1,25-dihydroxyvitamin D2 and 1,25-dihydroxyvitamin D3 in human serum using liquid chromatography with tandem mass spectrometry J. Chromatogr. B Anal. Technol. Biomed. Life Sci. 2016 1027 19 26 10.1016/j.jchromb.2016.04.034 27240300
91. Kissmeyer A.M. Sonne K. Sensitive analysis of 1alpha,25-dihydroxyvitamin D3 in biological fluids by liquid chromatography-tandem mass spectrometry J. Chromatogr. A 2001 935 93 103 10.1016/S0021-9673(01)00985-2 11762789
92. Yuan C. Kosewick J. He X. Kozak M. Wang S. Sensitive measurement of serum 1alpha,25-dihydroxyvitamin D by liquid chromatography/tandem mass spectrometry after removing interference with immunoaffinity extraction Rapid Commun. Mass Spectrom. 2011 25 1241 1249 10.1002/rcm.4988 21488122
93. Tang J.C.Y. Nicholls H. Piec I. Washbourne C.J. Dutton J.J. Jackson S. Greeves J. Fraser W.D. Reference intervals for serum 24,25-dihydroxyvitamin D and the ratio with 25-hydroxyvitamin D established using a newly developed LC–MS/MS method J. Nutr. Biochem. 2017 46 21 29 10.1016/j.jnutbio.2017.04.005 28437713
94. Baecher S. Leinenbach A. Wright J.A. Pongratz S. Kobold U. Thiele R. Simultaneous quantification of four vitamin D metabolites in human serum using high performance liquid chromatography tandem mass spectrometry for vitamin D profiling Clin. Biochem. 2012 45 1491 1496 10.1016/j.clinbiochem.2012.06.030 22771503
95. Mena-Bravo A. Priego-Capote F. Luque de Castro M.D. Study of blood collection and sample preparation for analysis of vitamin D and its metabolites by liquid chromatography-tandem mass spectrometry Anal. Chim. Acta 2015 879 69 76 10.1016/j.aca.2015.03.012 26002479
96. Tai S.S. Nelson M.A. Candidate reference measurement procedure for the determination of (24R),25-dihydroxyvitamin D3 in human serum using isotope-dilution liquid chromatography-tandem mass spectrometry Anal. Chem. 2015 87 7964 7970 10.1021/acs.analchem.5b01861 26171884
97. Wise S.A. Tai S.S. Nelson M.A. Burdette C.Q. Camara J.E. Hoofnagle A.N. Laha T.J. Carter G.D. Jones J. Williams E.L. Interlaboratory comparison for the determination of 24,25-dihydroxyvitamin D(3) in human serum using liquid chromatography with tandem mass spectrometry J. AOAC Int. 2017 100 1308 1317 10.5740/jaoacint.17-0183 28741469
98. Groenestege W.M.T. Bui H.N. Kate J.T. Menheere P.P.C.A. Oosterhuis W.P. Vader H.L. Heijboer A.C. Janssen M.J.W. Accuracy of first and second generation testosterone assays and improvement through sample extraction Clin. Chem. 2012 58 1154 1156 10.1373/clinchem.2011.181735 22539807
Figure 1

Vitamin D metabolism. From the production of vitamin D in the human skin or ingestion from certain vitamin D-rich foods to the final metabolisation into active (1,25(OH)2D) and largely inactive metabolites (24,25(OH)2D and 1,24,25(OH)3D). 25(OH)D: 25-hydroxyvitamin D; 1,25(OH)2D: 1,25-dihydroxyvitamin D; 24,25(OH)2D: 24,25-dihydroxyvitamin D; 1,24,25(OH)3D: 1,24,25-trihydroxyvitamin D.

Figure image at the original source — open the original paper. This file is not included in this text import.
Table 1

Advantages and disadvantages of current LC-MS/MS methods and immunoassays for vitamin D metabolism determination.

MetaboliteLC-MS/MSImmunoassay
25(OH)DAdvantages:
  • Sample preparation adaptable

  • Specificity

Disadvantages:
  • Complexity

  • Difficult to separate epi-25(OH)D3 from 25(OH)D3 (same mass and chromatographic behaviour)

Advantages *:
  • Fast

  • Easy operation

  • No cross reactivity with epi-25(OH)D

Disadvantages:
  • Patient group-dependent deviations

  • No distinction between 25(OH)D2 and 25(OH)D3

  • Cross-reactivity of other vitamin D metabolites recognised by the antibody, such as 24,25(OH)2D

1,25(OH)2DAdvantages:
  • Sample preparation adaptable

  • Specificity

Disadvantages:
  • Complexity

  • Sensitivity

  • Possible cross-reactivity from isobaric interferences

Advantages:
  • Fast

  • Easy operation

  • Sensitivity

Disadvantages:
  • No distinction between 1,25(OH)2D2 and 1,25(OH)2D3

  • Cross-reactivity of other vitamin D metabolites recognised by the antibody, such as 25(OH)D3 and 24,25(OH)2D

24,25(OH)2DAdvantages:
  • Sample preparation adaptable

  • Specificity

Disadvantages:
  • Complexity

N/A †N/A †

* The advantages listed are limited to the automated immunoassays. † Although 24,25(OH)2D immunoassays exist, too little information on their performance is available.

Publication and source details

Original title: The When, What & How of Measuring Vitamin D Metabolism in Clinical Medicine

Niek F. Dirks; Mariëtte T. Ackermans; Paul Lips; Renate T. de Jongh; Marc G. Vervloet; Robert de Jonge; Annemieke C. Heijboer

Nutrients · 2018

* Correspondence: a.heijboer@vumc.nl© 2018 by the authors.2018https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-11T04:53:41.402404+00:00

DOI: 10.3390/nu10040482 · PMC5946267