Vitamin D3 for Life. Live Enlightened.

Research libraryVitamin D3 For Life
Study design and methods

Primary relevance to vitamin D Vitamin D is a stated subject of this paper.

Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.

Why this paper is included

Supporting source evidence:

A novel caged Cookson‐type reagent toward a practical vitamin D derivatization method for mass spectrometric analyses

Source: Article title. View original paper

Relevance classification does not establish study quality, causation or editorial approval.

Study design Study design awaiting verification.

Study design awaiting verification

The available source does not establish a sufficiently clear study design.

Meta-analysis unclear · Blinding unclear / not reported · Research setting awaiting verification

How this paper was classified

Automatic source-based classification; awaiting editorial verification. This is not a quality score.

View supporting evidence in the original paper

What the study types mean
Systematic review
Uses explicit methods to identify, assess and summarise research on a defined question.
Scoping review
Maps the extent and characteristics of research on a topic.
Narrative review
Discusses existing research; systematic-review methods have not been established by this classification.
Review / evidence synthesis
Reviews existing research; the exact review methods need further assessment.
Randomised controlled trial
Assigns participants or groups to comparison interventions by chance.
Non-randomised intervention study
Examines an intervention without random allocation.
Cohort study
Examines exposures and outcomes over time within a defined group.
Case-control study
Compares people with an outcome against people without it, examining exposures.
Cross-sectional study
Examines a population at a particular point in time.
Observational study
Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
Case report
Describes an individual case.
Case series
Describes a group of individual cases.
Secondary analysis
Analyses existing study data; this paper is not automatically another independent trial.
Laboratory study
Investigates biological processes in a laboratory setting.
Qualitative study
Examines experiences or meanings using qualitative methods.
Genetic instrumental-variable study
Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Multiple reported designs
More than one design is explicitly reported; examine the supporting methods.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.

Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.

Full studies

A novel caged Cookson‐type reagent toward a practical vitamin D derivatization method for mass spectrometric analyses

Study design awaiting verification · Rapid Communications in Mass Spectrometry · 2020

Original publication title

A novel caged Cookson‐type reagent toward a practical vitamin D derivatization method for mass spectrometric analyses

Masahiko Seki; Makoto Sato; Masaki Takiwaki; Koji Takahashi; Yoshikuni Kikutani; Mamoru Satoh; Fumio Nomura; Yutaka Kuroda; Seketsu Fukuzawa

© 2019 The Authors. Rapid Communications in Mass Spectrometry published by John Wiley & Sons Ltd

Original publication · Publisher record · CC BY 4.0

Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.

Authors’ conclusion

We screened several diene groups to develop the caged Cookson‐type reagent, DAP‐PA, which was stable enough for mid‐ to long‐term storage in solution. Highly stable reagents are essential for data reproducibility in clinical laboratories. The stability of the reagents in a solution is guaranteed by the production of pure products, which is generally achieved by crystallization, and the caged DAPTAD is easy to crystallize, which is a strong advantage in terms of quality control. In addition, from a practical viewpoint, the caged DAPTAD is available in large quantities, and thus market supply is stable and ample.

This advantage will contribute to the field of VD detection and quantification in clinical laboratories, and thus to the broader use of clinical mass spectrometry.24

An extract from the source publication. Read it in context.

At a glance

Abstract: What methods does the paper describe?

Caged 4‐(4′‐dimethylaminophenyl)‐1,2,4‐triazoline‐3,5‐dione (DAPTAD) analogues were prepared from 4‐(4′‐dimethylaminophenyl)‐1,2,4‐triazolidine‐3,5‐dione. Their stability and reactivity were examined. The optimized caged DAPTAD (14‐(4‐(dimethylamino)phenyl)‐9‐phenyl‐9,10‐dihydro‐9,10‐[1,2]epitriazoloanthracene‐13,15‐dione, DAP‐PA) was used for LC/MS/MS analyses of VD metabolites.

Source: Methods

Study background

What background does the paper provide?

Vitamin D (VD) metabolites play an important role in homeostatic maintenance, such as bone metabolism.1 Because VD deficiency is reportedly linked to a wide range of human diseases, the requirement for the evaluation of VD status is increasing in clinical medicine.1 25‐Hydroxylated VD (25(OH)D) is the best marker for VD status.2 Although 25‐hydroxyvitamin D3 (25(OH)D3) normally accounts for most of serum 25(OH)D, differential determination of 25‐hydroxyvitamin D2 (25(OH)D2) is desirable when VD2‐containing supplements are used by the subject (patient).

Because significant levels of the C‐3 epimer of 25(OH)D3, 3‐epi‐25(OH)D3, are present in the serum in both infants and adults,3 its presence may result in the overestimation of 25(OH)D if it is not properly resolved by chromatography. Furthermore, the accurate quantification of 24R,25‐dihydroxyvitamin D3 (24,25(OH)2D3) is essential for the differential diagnosis of infantile hypercalcemia of unknown etiology.4 Thus, there is an increasing demand for the quantitative and routine mass spectrometric measurement of differential VD metabolites.5 Because VD metabolites exhibit a low ionization efficiency under the conditions used in VD analysis by liquid chromatography/tandem mass spectrometry (LC/MS/MS), attempts to improve ionization efficiency by derivatization are being reported.6

VD metabolites have a particular structural feature: a conjugated s‐cis diene. Consequently, VD selective derivatization reagents that take advantage of the reactive dienophile, 1,2,4‐triazoline‐3,5‐dione (TAD), which is known as a Cookson‐type reagent, have been developed for enhancing their detection limits in mass spectrometric analyses.7, 8 4‐Phenyl‐1,2,4‐triazoline‐3,5‐dione (PTAD)9 is a well‐known VD metabolite selective derivatization reagent for LC/MS/MS, and its improved version, 4‐(4′‐dimethylaminophenyl)‐1,2,4‐triazoline‐3,5‐dione (DAPTAD),10, 11 developed by Higashi et al., enables a quantitative and differential detection of VD metabolites (Figure 1).

We previously described the quantitative measurement of four VD metabolites (25(OH)D3, 25(OH)D2, 3‐epi‐25(OH)D3, and 24,25(OH)2D3) in serum by LC/MS/MS using DAPTAD derivatization.12 DAPTAD, however, is not necessarily appropriate for routine use in the clinical laboratory because of the following reasons: it is difficult to isolate DAPTAD from the reaction mixture; DAPTAD solution without purification needs to be stored at −18°C and is recommended for use within 2 months.10 In addition, on‐site preparation of the chemicals is inherently associated with a risk of contamination, which may affect the yield of the derivatization reaction.

Furthermore, water condensation can also disturb or hamper the derivatization reaction, and ambient or near‐ambient temperature (refrigerator level) storage of the reagent solution is thus desirable, which, on the other hand, will affect the reagent's stability. Overcoming these limitations would enable not only an easier operational handling, but may also open the way to the automated and routine detection/quantification of VD metabolites. Effective TAD reagents, including DAPTAD, for VD metabolites have been reported;13, 14 however, their solution stability were often low or in many cases not investigated.

Although 2‐nitrosopyridine15 might be a better derivatization reagent for VD metabolites than TAD reagents, popularity and accumulated knowledge of 2‐nitrosopyridine as a derivatization reagent are still limited compared with those of well‐known and widely used TAD reagents. In addition, long‐term solution stability of 2‐nitrosopyridine has not yet been confirmed. These factors motivated us to use TAD in our experiment. The stability of TAD reagents is dependent on the TAD group and not on the conjugated aromatic functional group. Therefore, we focused on DAPTAD as a representative TAD molecule.

Figure 1

Derivatization of vitamin D (VD) metabolites using Cookson‐type reagents

Figure image at the original source: open the original paper. This file is not included in this text import.

We describe the development of a novel caged Cookson‐type reagent, 14‐(4‐(dimethylamino)phenyl)‐9‐phenyl‐9,10‐dihydro‐9,10‐[1,2]epitriazoloanthracene‐13,15‐dione (DAP‐PA), which can produce DAPTAD by thermal retro‐Diels‐Alder (RDA) reaction and present preliminary analytical performances of DAP‐PA when applied to the quantitative and differential measurement of the four VD metabolites in serum by LC/MS/MS.

Source: INTRODUCTION Source: INTRODUCTION Source: INTRODUCTION Source: INTRODUCTION

Abstract: Rationale

25‐Hydroxylated vitamin D is the best marker for vitamin D (VD). Due to its low ionization efficiency, a Cookson‐type reagent, 1,2,4‐triazoline‐3,5‐dione (TAD), is used to improve the detection/quantification of VD metabolites by liquid chromatography/tandem mass spectrometry (LC/MS/MS). However, the high reactivity of TAD makes its solution stability low and inconvenient for practical use. We here describe the development of a novel caged Cookson‐type reagent, and we assess its performances in the quantitative and differential detection of four VD metabolites in serum using LC/MS/MS.

Source: Rationale

EXPERIMENTAL

2.1

Characterization of synthetic compounds

1H‐NMR (nuclear magnetic resonance) spectra were recorded on a JEOL JNM‐ECA400II and a JEOL JNM‐ECA500 spectrometer (Akishima, Tokyo, Japan) operating at 400 MHz (1H) and 100 MHz (13C), respectively. Chemical shifts are reported in δ units and referenced to the solvent, that is, 7.24 (1H) and 77.0 (13C) for CDCl3. Multiplicities are indicated as br (broadened), s (singlet), d (doublet), t (triplet), or m (multiplet). Coupling constants (J) are reported in Hertz (Hz).

High‐resolution mass spectra (HRMS) were recorded on a JEOL T100LP mass spectrometer (Akishima, Tokyo, Japan) under fast atom bombardment (FAB) conditions using m‐nitrobenzyl alcohol as a matrix. IR spectra were recorded on a Spectrum One spectrometer (Perkin Elmer, Waltham, MA, USA).

2.2

Preparation of caged DAPTAD

4‐(4′‐Dimethylaminophenyl)‐1,2,4‐triazolidine‐3,5‐dione10 (0.5 g, 2.27 mmol), iodosylbenzene (0.5 g, 2.27 mmol), anhydrous magnesium sulfate (2 g), and 9‐phenylanthracene or 1,4‐diphenyl‐1,3‐butadiene (1 eq) were added to a nitrogen‐purged ethyl acetate solution (Figure 2). The resultant reaction mixture was stirred at room temperature in the dark until the solution turned dark red. After 4 h, the mixture was transferred into a separation funnel, washed with 5% sodium hydrogen carbonate (80 mL), and again washed with water (80 mL × 2) and brine.

The organic layer was dried over anhydrous magnesium sulfate, filtrated, and concentrated under reduced pressure. Purification by silica gel chromatography (hexane/ethyl acetate [7:3, v/v]) produced the caged DAPTAD as white crystals. The yields were 52% for the 9‐phenylanthracene adduct (DAP‐PA) and 61% for the 1,4‐diphenyl‐1,3‐butadiene adduct (2‐(4‐(dimethylamino)phenyl)‐5,8‐diphenyl‐5,8‐dihydro‐1H‐[1,2,4]triazolo[1,2‐a]pyridazine‐1,3(2H)‐dione, DAP‐DP).

Figure 2

Preparation of caged 4‐(4′‐dimethylaminophenyl)‐1,2,4‐triazoline‐3,5‐dione (DAPTAD)

Figure image at the original source: open the original paper. This file is not included in this text import.
2.3

Physical properties of DAP‐PA

1H‐NMR (CDCl3) δ 7.85 (d, J = 7.6 Hz, 2H), 7.59 to 7.49 (m, 5H), 7.31 (td, J = 7.6, 1.2 Hz, 2H), 7.22 (td, J = 7.6, 1.2 Hz, 2H), 7.03 (d, J = 7.6 Hz, 2H), 6.78 (ddd, J = 9.0, 3.2, 2.4 Hz, 2H), 6.56 (ddd, J = 9.0, 3.2, 2.4 Hz, 2H), 6.40 (s, 4H), 2.87 (s, 6H); 13C‐NMR (CDCl3) δ 158.2, 157.3, 150.3, 139.3, 132.5, 129.8, 128.8, 128.1, 128.0, 127.8, 126.6, 124.5, 123.9, 119.4, 112.2, 72.6, 62.6, 40.5; IR (KBr, cm−1) 3062, 1774, 1714, 1613, 1526, 1460, 1448, 1417, 1361, 1248, 1230, 1181, 1158, 1039, 1004, 946, 846, 805, 784, 764, 753, 702, 679, 634, 541; HRMS (FAB) calculated for C30H25N4O2 [(M + H)+] 473.19775, found 473.19683.

2.4

Physical properties of DAP‐DP

1H‐NMR (CDCl3) δ 7.52 (brd, J = 8.4 Hz, 4H), 7.42 to 7.32 (m, 6H), 7.18 (ddd, J = 9.2, 3.2, 2.4 Hz, 2H), 6.63 (ddd, J = 9.2, 3.2, 2.4 Hz, 2H), 5.99 (d, J = 1.2 Hz, 2H), 5.53 (d, J = 1.2 Hz, 2H), 2.89 (s, 6H); 13C‐NMR (CDCl3) δ 152.6, 137.4, 128.8, 128.6, 127.9, 126.4, 125.4, 112.3, 58.3, 40.5; IR (KBr, cm−1) 3031, 2941, 2802, 1771, 1701, 1614, 1523, 1493, 1447, 1420, 1352, 1289, 1193, 1158, 1143, 1063, 946, 878, 846, 819, 753, 698, 610, 588, 517; HRMS (FAB) calculated for C26H25N4O2 [(M + H)+] 425.19775, found 425.18956.

2.5

Analytical high‐performance liquid chromatography (HPLC)

The chromatographic analysis of the RDA reaction was performed using an Alliance HPLC system equipped with a model 2489 UV: Vis detector (Waters, Milford, MA, USA). Chromatography was performed using an Inertsil ODS‐3 column (4.6 mm I.D. × 250 mm (5 μm; GL Sciences, Tokyo, Japan) with a binary gradient system with water (A) and acetonitrile (B) and a flow rate of 1.0 mL/min. The detection wavelength was 210 nm, and the elution program was as follows: 0 → 10 min, 50% B; 10 → 20 min, 50 → 5% B; 20 → 50 min, 5% B; 50 → 55 min, 50% B; 55 → 60 min, 50% B.

2.6

Kinetic analysis of the RDA reaction

The rate constant k 1 was determined using the following equation describing the irreversible diene tag, 1,4‐diphenyl‐1,3‐buthadiene (Figures 3 and 4).

dx/dt=k1aNot reportedx.
lna/aNot reportedx=k1t.
Figure 3

Thermal retro‐Diels‐Alder (RDA) reaction of the caged DAPTAD

Figure image at the original source: open the original paper. This file is not included in this text import.
Figure 4

Kinetic analysis of the RDA reaction

Figure image at the original source: open the original paper. This file is not included in this text import.
2.7

Materials for LC/MS/MS

The JeoQuant kit for LC/MS/MS analysis of vitamin D metabolites including calibrators (25(OH)D3, 25(OH)D2, 3‐epi‐25(OH)D3, and 24,25(OH)2D3); internal standards (25(OH)D3‐[23,24,25,26,27‐13C5], 25(OH)D2‐[25,26,27‐13C3], 3‐epi‐25(OH)D3‐[23,24,25,26,27‐13C5], and 24,25(OH)2D3‐[26,26,26,27,27,27‐2H6]); quality controls; and the derivatization reagent (DAP‐PA ethyl acetate solution [0.5 mg/mL]) were obtained from JEOL (Akishima, Tokyo, Japan; https://www.jeol.co.jp/en/support/support_system/contact_jeoquantkit.html).

The calibrator concentrations for 25(OH)D3, 25(OH)D2, 3‐epi‐25(OH)D3, and 24,25(OH)2D3 were as follows: 0.873, 0.0920, 0.0940, and 0.0960 ng/mL for calibrator level 1; 8.80, 0.924, 0.938, and 0.962 ng/mL for calibrator level 2; 44.0, 4.62, 4.69, and 4.81 ng/mL for calibrator level 3; and 88.0, 9.23, 9.37, and 9.61 ng/mL for calibrator level 4. These concentrations were determined by quantitative NMR measurements.16 Human Serum Standard Reference Material (SRM972a) was obtained from the National Institute of Standards and Technology (NIST, Gaithersburg, MD, USA).

LC/MS‐grade acetonitrile and formic acid were purchased from Wako Pure Chemical Industries (Osaka, Japan). HPLC‐grade distilled water was obtained from Nacalai Tesque (Kyoto, Japan).

2.8

DAPTAD derivatization

DAP‐PA solution (100 μL) was added to the dried samples, and the resultant mixture was heated at 80°C for 15 min. Ethanol (20 μL) was added to the mixture to terminate the reaction, and the solvent was removed by centrifuged evaporation. The residue was dissolved in 50 μL of 30% aqueous acetonitrile for LC/MS/MS analyses.

2.9

Extraction of VD metabolites from SRM972a level 2 serum

SRM972a level 2 serum (50 μL) and internal standards (250 μL) were mixed and vortexed for 1 min. Each sample was loaded into a supported liquid extraction column (ISOLUTE® SLE+ 400 μL sample volume, Biotage, Uppsala, Sweden) and eluted three times with 600 μL ethyl acetate/hexane (1:1, v/v) using a PRESSURE+48 positive pressure manifold (Biotage). The combined eluents were evaporated to dryness using a centrifuged evaporator. DAPTAD derivatization of the obtained samples was carried out as described above.

2.10

LC/MS/MS analyses

LC/MS/MS analyses were performed using an QTRAP4500® triple quadruple mass spectrometer (AB SCIEX, Framingham, MA, USA) equipped with a model 1290 Infinity liquid chromatography system (Agilent Technologies, Santa Clara, CA, USA). Chromatography was performed using a binary gradient system with 0.1% formic acid (A) and 0.1% formic acid in acetonitrile (B) or methanol (C). Samples were dissolved in 50 μL of 30% aqueous acetonitrile and loaded into a CAPCELL CORE C18 (2.7 μm) 2.1 mm I.D. × 100 mm column (OSAKA SODA, Osaka, Japan) equilibrated with 0.1% formic acid 30% acetonitrile with a flow rate of 0.3 mL/min.

The injection volume was 20 μL. The elution program was as follows: 0.01 → 0.5 min, 30 → 58% B; 0.5 → 7.0 min, 58% B; 7.0 → 7.01 min, 58 → 90% B; 7.01 → 8.0 min, 90% B; 8.0 → 8.01 min, 90 → 30% B; 8.01 → 9.0 min, 30% B. For analyses of non‐derivatized VD metabolites, an InertSustain PFP HP (3 μm) 2.1 mm I.D. × 150 mm column (GL Sciences, Tokyo, Japan) was used. The flow rate was 0.4 mL/min, and the elution program was as follows: 0.01 → 0.5 min, 50 → 67% C; 0.5 → 9.0 min, 67% C; 9.0 → 9.01 min, 67 → 90% C; 9.01 → 11.0 min, 90% C; 11.0 → 11.01 min, 90 → 50% C; 11.01 → 13.0 min, 50% C.

Ionization was done with the positive ion mode, and selected reaction monitoring (SRM) was used for quantification. The transitions (m/z) and collision energies (CE) for the VD metabolites are summarized in Table 1. Operation and quantification analyses were done using Analyst® (version 1.7) and SCIEX OS software (AB SCIEX), respectively. The limit of detection (LOD) was determined from duplicate measurements of the authentic VD metabolite solution diluted with water as follows: 1:1 (not diluted), 1:8, 1:16, 1:32, 1:64, 1:128, 1:200, 1:256, 1:400, and 1:800.

The LODs were defined as the concentration of VD metabolites per injection giving a signal‐to‐noise ratio (S/N) of 10, which was manually calculated as the peak height divided by the noise level around the peak. The lower limit of quantification (LLOQ) was determined from three replicate measurements of SRM972a level 2 serum diluted with water as follows: 1:1 (not diluted), 1:2, 1:4, 1:8, 1:10, 1:16, 1:20, 1:32, 1:40, 1:64, 1:80, 1:160, 1:320, and 1:640. The LLOQs were set to the minimum level at which dilution linearity was confirmed and the coefficient of the variance was at most 15% and given by the concentration of VD metabolites per injection giving the S/N of 15.

Table 1

Tandem mass spectrometry parameters of vitamin D (VD) metabolites with and without 4‐(4′‐dimethylaminophenyl)‐1,2,4‐triazoline‐3,5‐dione (DAPTAD) derivatization

With derivatizationWithout derivatization
m/z CE m/z CE
25(OH)D3 and 3‐epi‐25(OH)D3 619.3 > 341.135401.2 > 91.089
25(OH)D3Not reported13C5 and 3‐epi‐25(OH)D3Not reported13C5 624.5 > 341.135
25(OH)D2 631.3 > 341.133417.1 > 105.165
25(OH)D2‐13C3 634.3 > 341.233
24,25(OH)2D3 635.3 > 341.137417.1 > 105.165
24,25(OH)2D3‐d 6 641.5 > 341.137

CE, collision energy.

Source: EXPERIMENTAL Source: EXPERIMENTAL Source: EXPERIMENTAL Source: EXPERIMENTAL Source: EXPERIMENTAL Source: EXPERIMENTAL Source: EXPERIMENTAL Source: EXPERIMENTAL Source: EXPERIMENTAL Source: EXPERIMENTAL

Solution stability of DAPTAD and DAP‐PA

RESULTS AND DISCUSSION: Solution stability of DAPTAD and DAP‐PA

Although TAD is one of the most reactive dienophiles and provides an excellent derivatization tag, its solution instability has been reported.17, 18, 19, 20 In nucleophilic solvent systems (alcohols or water), it undergoes a nucleophilic attack of its oxygen functional groups or a loss of nitrogen‐yielding dimeric compounds. We first examined the solution stability of DAPTAD, which was synthesized according to the published protocol,10 using NMR. The amount of residual DAPTAD was estimated by the integration of aromatic proton peaks (Figures 5 and S1, supporting information).

As expected, a time‐dependent decrease in the proton signals was observed in ethyl acetate, which is a common solvent for DAPTAD derivatization.10 The addition of molecular sieves 4A at 4°C increased the solution stability of DAPTAD, which strongly suggested that a nucleophilic attack by residual moisture occurred in the non‐caged TAD. On the other hand, the solution stability of DAP‐PA in ethyl acetate dramatically improved (Figure 6) in comparison with that of the non‐caged TAD, which indicated that a DA‐type protection (Figure 3) of the dienophile, TAD, was effective.

Figure 5

Solution stability of DAPTAD in ethyl acetate‐d 8 with (●: 4°C; ▲: 25°C) and without (■: 4°C; ◆: 25°C) molecular sieves 4A monitored using NMR spectroscopy [Color figure can be viewed at http://wileyonlinelibrary.com]

Figure image at the original source: open the original paper. This file is not included in this text import.
Figure 6

Solution stability of DAP‐PA monitored by HPLC.: 22.5°C (●), 6.8°C (▲), 25°C (■), 40°C (◆) [Color figure can be viewed at http://wileyonlinelibrary.com]

Figure image at the original source: open the original paper. This file is not included in this text import.
Source: Solution stability of DAPTAD and DAP‐PA Source: Solution stability of DAPTAD and DAP‐PA Source: Solution stability of DAPTAD and DAP‐PA

RESULTS AND DISCUSSION: RDA reaction of caged DAPTAD

The RDA reaction is a reversible reaction, which can be controlled by thermal regulation (Figure 3).21, 22 This dynamic, reversible covalent bond formation and cleavage makes it possible to consider thermal protection and deprotection. The thermal RDA reaction enabling the release of DAPTAD was examined using analytical HPLC. DAPTAD itself was difficult to detect using reversed‐phase HPLC due to its instability in aqueous solvents, and we thus monitored the presence of 1,4‐diphenyl‐1,3‐butadiene and 9‐phenylanthracene at 70°C in ethyl acetate, which showed that the reaction with 1,4‐diphenyl‐1,3‐butadiene was irreversible (Figure 3).

On the other hand, the release of 9‐phenylanthracene was observed using the irreversible diene tag, 1,4‐diphenyl‐1,3‐buthadiene (Figures 4 and S8, supporting information). The release rate of 9‐phenylanthracene from DAP‐PA in ethyl acetate was temperature‐dependent (Table 2).21, 22 The reaction temperature (Table S9, supporting information), time (Table S10, supporting information), solvent (Table S2, supporting information), and concentration (Figure S11, supporting information) were also investigated using LC/MS/MS. The reaction was saturated in about 15 min. Although the reaction with aromatic solvents (toluene, anisole, and o‐dichlorobenzene) gave better rate constants than that with ethyl acetate (Table S2, supporting information), the peak area in the SRM chromatogram of derivatized VD metabolites produced in ethyl acetate was larger than that produced in toluene (Figure S11, supporting information).

Considering their boiling points (indicating the easiness to remove), we concluded that ethyl acetate at 80°C was the best reaction condition.

Table 2

Release rate of 9‐phenylanthracene from DAP‐PA in ethyl acetate

Reaction temperature (°C)Rate constant k 1 (h−1)
500.07
600.18
701.01
77a 2.50
a

Boiling point of ethyl acetate.

Source: RDA reaction of caged DAPTAD Source: RDA reaction of caged DAPTAD

LC/MS/MS analyses of VDs without serum

RESULTS AND DISCUSSION: LC/MS/MS analyses of VDs without serum

Four VD metabolites with and without DAPTAD derivatization in the absence of serum were detected using the previously reported procedure.12 Their retention time (t R), LOD values, and sensitivity increase are summarized in Table 3.

Table 3

LODs for VD metabolites with and without DAPTAD derivatization in the absence of serum

With derivatizationWithout derivatization
t R a (min)LOD (ng/mL) t R a (min)LOD (ng/mL)Sensitivity increase
25(OH)D3 5.590.0556.971.425
25(OH)D2 6.700.0367.604.6128
3‐epi‐25(OH)D3 5.270.0377.490.5916
24,25(OH) 2D3 2.970.0374.260.308

LOD, limit of detection.

a

Derivatized and non‐derivatized VD metabolites were analyzed using CAPCELL CORE C18 and InertSustain PFP HP columns, respectively.

Source: LC/MS/MS analyses of VDs without serum Source: LC/MS/MS analyses of VDs without serum

LC/MS/MS analyses of VDs in SRM972a level 2 serum

RESULTS AND DISCUSSION: LC/MS/MS analyses of VDs in SRM972a level 2 serum

LLOQs of four VD metabolites in SRM972a level 2 serum with DAPTAD derivatization are summarized in Table 4. Their SRM chromatograms are shown in Figure 7. In our study 1α, 25‐dihydroxyvitamin D3 (1,25(OH)2D3) could not be detected quantitatively due to its extremely low concentration and the difficulty in chromatographic separation of 1,25(OH)2D3 and other dihydroxylated VD metabolites such as 4β, 25‐dihydroxyvitamin D.23 This problem could be solved by combining our present protocol with immunoaffinity extraction.23

Table 4

LLOQs for VD metabolites with DAPTAD derivatization in SRM972a level 2 serum

LLOQ (ng/mL)
25(OH)D3 0.12
25(OH)D2 0.045
3‐epi‐25(OH)D3 0.065
24,25(OH)2D3 0.072

LLOQ, lower limit of quantification.

Figure 7

Selected reaction monitoring chromatograms of DAPTAD‐derivatized VDs in SRM972a level 2 serum

Figure image at the original source: open the original paper. This file is not included in this text import.
Source: LC/MS/MS analyses of VDs in SRM972a level 2 serum Source: LC/MS/MS analyses of VDs in SRM972a level 2 serum Source: LC/MS/MS analyses of VDs in SRM972a level 2 serum

RESULTS AND DISCUSSION

3.1

Solution stability of DAPTAD and DAP‐PA

Although TAD is one of the most reactive dienophiles and provides an excellent derivatization tag, its solution instability has been reported.17, 18, 19, 20 In nucleophilic solvent systems (alcohols or water), it undergoes a nucleophilic attack of its oxygen functional groups or a loss of nitrogen‐yielding dimeric compounds. We first examined the solution stability of DAPTAD, which was synthesized according to the published protocol,10 using NMR. The amount of residual DAPTAD was estimated by the integration of aromatic proton peaks (Figures 5 and S1, supporting information).

As expected, a time‐dependent decrease in the proton signals was observed in ethyl acetate, which is a common solvent for DAPTAD derivatization.10 The addition of molecular sieves 4A at 4°C increased the solution stability of DAPTAD, which strongly suggested that a nucleophilic attack by residual moisture occurred in the non‐caged TAD. On the other hand, the solution stability of DAP‐PA in ethyl acetate dramatically improved (Figure 6) in comparison with that of the non‐caged TAD, which indicated that a DA‐type protection (Figure 3) of the dienophile, TAD, was effective.

Figure 5

Solution stability of DAPTAD in ethyl acetate‐d 8 with (●: 4°C; ▲: 25°C) and without (■: 4°C; ◆: 25°C) molecular sieves 4A monitored using NMR spectroscopy [Color figure can be viewed at http://wileyonlinelibrary.com]

Figure image at the original source: open the original paper. This file is not included in this text import.
Figure 6

Solution stability of DAP‐PA monitored by HPLC.: 22.5°C (●), 6.8°C (▲), 25°C (■), 40°C (◆) [Color figure can be viewed at http://wileyonlinelibrary.com]

Figure image at the original source: open the original paper. This file is not included in this text import.
3.2

RDA reaction of caged DAPTAD

The RDA reaction is a reversible reaction, which can be controlled by thermal regulation (Figure 3).21, 22 This dynamic, reversible covalent bond formation and cleavage makes it possible to consider thermal protection and deprotection. The thermal RDA reaction enabling the release of DAPTAD was examined using analytical HPLC. DAPTAD itself was difficult to detect using reversed‐phase HPLC due to its instability in aqueous solvents, and we thus monitored the presence of 1,4‐diphenyl‐1,3‐butadiene and 9‐phenylanthracene at 70°C in ethyl acetate, which showed that the reaction with 1,4‐diphenyl‐1,3‐butadiene was irreversible (Figure 3).

On the other hand, the release of 9‐phenylanthracene was observed using the irreversible diene tag, 1,4‐diphenyl‐1,3‐buthadiene (Figures 4 and S8, supporting information). The release rate of 9‐phenylanthracene from DAP‐PA in ethyl acetate was temperature‐dependent (Table 2).21, 22 The reaction temperature (Table S9, supporting information), time (Table S10, supporting information), solvent (Table S2, supporting information), and concentration (Figure S11, supporting information) were also investigated using LC/MS/MS. The reaction was saturated in about 15 min. Although the reaction with aromatic solvents (toluene, anisole, and o‐dichlorobenzene) gave better rate constants than that with ethyl acetate (Table S2, supporting information), the peak area in the SRM chromatogram of derivatized VD metabolites produced in ethyl acetate was larger than that produced in toluene (Figure S11, supporting information).

Considering their boiling points (indicating the easiness to remove), we concluded that ethyl acetate at 80°C was the best reaction condition.

Table 2

Release rate of 9‐phenylanthracene from DAP‐PA in ethyl acetate

Reaction temperature (°C)Rate constant k 1 (h−1)
500.07
600.18
701.01
77a 2.50
a

Boiling point of ethyl acetate.

3.3

LC/MS/MS analyses of VDs without serum

Four VD metabolites with and without DAPTAD derivatization in the absence of serum were detected using the previously reported procedure.12 Their retention time (t R), LOD values, and sensitivity increase are summarized in Table 3.

Table 3

LODs for VD metabolites with and without DAPTAD derivatization in the absence of serum

With derivatizationWithout derivatization
t R a (min)LOD (ng/mL) t R a (min)LOD (ng/mL)Sensitivity increase
25(OH)D3 5.590.0556.971.425
25(OH)D2 6.700.0367.604.6128
3‐epi‐25(OH)D3 5.270.0377.490.5916
24,25(OH) 2D3 2.970.0374.260.308

LOD, limit of detection.

a

Derivatized and non‐derivatized VD metabolites were analyzed using CAPCELL CORE C18 and InertSustain PFP HP columns, respectively.

3.4

LC/MS/MS analyses of VDs in SRM972a level 2 serum

LLOQs of four VD metabolites in SRM972a level 2 serum with DAPTAD derivatization are summarized in Table 4. Their SRM chromatograms are shown in Figure 7. In our study 1α, 25‐dihydroxyvitamin D3 (1,25(OH)2D3) could not be detected quantitatively due to its extremely low concentration and the difficulty in chromatographic separation of 1,25(OH)2D3 and other dihydroxylated VD metabolites such as 4β, 25‐dihydroxyvitamin D.23 This problem could be solved by combining our present protocol with immunoaffinity extraction.23

Table 4

LLOQs for VD metabolites with DAPTAD derivatization in SRM972a level 2 serum

LLOQ (ng/mL)
25(OH)D3 0.12
25(OH)D2 0.045
3‐epi‐25(OH)D3 0.065
24,25(OH)2D3 0.072

LLOQ, lower limit of quantification.

Figure 7

Selected reaction monitoring chromatograms of DAPTAD‐derivatized VDs in SRM972a level 2 serum

Figure image at the original source: open the original paper. This file is not included in this text import.
Source: RESULTS AND DISCUSSION Source: RESULTS AND DISCUSSION Source: RESULTS AND DISCUSSION Source: RESULTS AND DISCUSSION

CONCLUSIONS

We screened several diene groups to develop the caged Cookson‐type reagent, DAP‐PA, which was stable enough for mid‐ to long‐term storage in solution. Highly stable reagents are essential for data reproducibility in clinical laboratories. The stability of the reagents in a solution is guaranteed by the production of pure products, which is generally achieved by crystallization, and the caged DAPTAD is easy to crystallize, which is a strong advantage in terms of quality control. In addition, from a practical viewpoint, the caged DAPTAD is available in large quantities, and thus market supply is stable and ample.

This advantage will contribute to the field of VD detection and quantification in clinical laboratories, and thus to the broader use of clinical mass spectrometry.24

Source: CONCLUSIONS
Authors’ abstract

Rationale

25‐Hydroxylated vitamin D is the best marker for vitamin D (VD). Due to its low ionization efficiency, a Cookson‐type reagent, 1,2,4‐triazoline‐3,5‐dione (TAD), is used to improve the detection/quantification of VD metabolites by liquid chromatography/tandem mass spectrometry (LC/MS/MS). However, the high reactivity of TAD makes its solution stability low and inconvenient for practical use. We here describe the development of a novel caged Cookson‐type reagent, and we assess its performances in the quantitative and differential detection of four VD metabolites in serum using LC/MS/MS.

Methods

Caged 4‐(4′‐dimethylaminophenyl)‐1,2,4‐triazoline‐3,5‐dione (DAPTAD) analogues were prepared from 4‐(4′‐dimethylaminophenyl)‐1,2,4‐triazolidine‐3,5‐dione. Their stability and reactivity were examined. The optimized caged DAPTAD (14‐(4‐(dimethylamino)phenyl)‐9‐phenyl‐9,10‐dihydro‐9,10‐[1,2]epitriazoloanthracene‐13,15‐dione, DAP‐PA) was used for LC/MS/MS analyses of VD metabolites.

Results

The solution stability of DAP‐PA in ethyl acetate dramatically improved compared with that of the non‐caged one. We measured the thermal retro‐Diels‐Alder reaction enabling the release of DAPTAD and found that the derivatization reaction was temperature‐dependent. We also determined the detection limit and the lower limit of quantifications for four VD metabolites with DAPTAD derivatization.

Conclusions

DAP‐PA was stable enough for mid‐ to long‐term storage in solution. This advantage shall contribute to the detection and quantification of VD in clinical laboratories, and as such to the broader use of clinical mass spectrometry.

Read the full paper
1

INTRODUCTION

Vitamin D (VD) metabolites play an important role in homeostatic maintenance, such as bone metabolism.1 Because VD deficiency is reportedly linked to a wide range of human diseases, the requirement for the evaluation of VD status is increasing in clinical medicine.1 25‐Hydroxylated VD (25(OH)D) is the best marker for VD status.2 Although 25‐hydroxyvitamin D3 (25(OH)D3) normally accounts for most of serum 25(OH)D, differential determination of 25‐hydroxyvitamin D2 (25(OH)D2) is desirable when VD2‐containing supplements are used by the subject (patient).

Because significant levels of the C‐3 epimer of 25(OH)D3, 3‐epi‐25(OH)D3, are present in the serum in both infants and adults,3 its presence may result in the overestimation of 25(OH)D if it is not properly resolved by chromatography. Furthermore, the accurate quantification of 24R,25‐dihydroxyvitamin D3 (24,25(OH)2D3) is essential for the differential diagnosis of infantile hypercalcemia of unknown etiology.4 Thus, there is an increasing demand for the quantitative and routine mass spectrometric measurement of differential VD metabolites.5 Because VD metabolites exhibit a low ionization efficiency under the conditions used in VD analysis by liquid chromatography/tandem mass spectrometry (LC/MS/MS), attempts to improve ionization efficiency by derivatization are being reported.6

VD metabolites have a particular structural feature: a conjugated s‐cis diene. Consequently, VD selective derivatization reagents that take advantage of the reactive dienophile, 1,2,4‐triazoline‐3,5‐dione (TAD), which is known as a Cookson‐type reagent, have been developed for enhancing their detection limits in mass spectrometric analyses.7, 8 4‐Phenyl‐1,2,4‐triazoline‐3,5‐dione (PTAD)9 is a well‐known VD metabolite selective derivatization reagent for LC/MS/MS, and its improved version, 4‐(4′‐dimethylaminophenyl)‐1,2,4‐triazoline‐3,5‐dione (DAPTAD),10, 11 developed by Higashi et al., enables a quantitative and differential detection of VD metabolites (Figure 1).

We previously described the quantitative measurement of four VD metabolites (25(OH)D3, 25(OH)D2, 3‐epi‐25(OH)D3, and 24,25(OH)2D3) in serum by LC/MS/MS using DAPTAD derivatization.12 DAPTAD, however, is not necessarily appropriate for routine use in the clinical laboratory because of the following reasons: it is difficult to isolate DAPTAD from the reaction mixture; DAPTAD solution without purification needs to be stored at −18°C and is recommended for use within 2 months.10 In addition, on‐site preparation of the chemicals is inherently associated with a risk of contamination, which may affect the yield of the derivatization reaction.

Furthermore, water condensation can also disturb or hamper the derivatization reaction, and ambient or near‐ambient temperature (refrigerator level) storage of the reagent solution is thus desirable, which, on the other hand, will affect the reagent's stability. Overcoming these limitations would enable not only an easier operational handling, but may also open the way to the automated and routine detection/quantification of VD metabolites. Effective TAD reagents, including DAPTAD, for VD metabolites have been reported;13, 14 however, their solution stability were often low or in many cases not investigated.

Although 2‐nitrosopyridine15 might be a better derivatization reagent for VD metabolites than TAD reagents, popularity and accumulated knowledge of 2‐nitrosopyridine as a derivatization reagent are still limited compared with those of well‐known and widely used TAD reagents. In addition, long‐term solution stability of 2‐nitrosopyridine has not yet been confirmed. These factors motivated us to use TAD in our experiment. The stability of TAD reagents is dependent on the TAD group and not on the conjugated aromatic functional group. Therefore, we focused on DAPTAD as a representative TAD molecule.

Figure 1

Derivatization of vitamin D (VD) metabolites using Cookson‐type reagents

Figure image at the original source: open the original paper. This file is not included in this text import.

We describe the development of a novel caged Cookson‐type reagent, 14‐(4‐(dimethylamino)phenyl)‐9‐phenyl‐9,10‐dihydro‐9,10‐[1,2]epitriazoloanthracene‐13,15‐dione (DAP‐PA), which can produce DAPTAD by thermal retro‐Diels‐Alder (RDA) reaction and present preliminary analytical performances of DAP‐PA when applied to the quantitative and differential measurement of the four VD metabolites in serum by LC/MS/MS.

2

EXPERIMENTAL

2.1

Characterization of synthetic compounds

1H‐NMR (nuclear magnetic resonance) spectra were recorded on a JEOL JNM‐ECA400II and a JEOL JNM‐ECA500 spectrometer (Akishima, Tokyo, Japan) operating at 400 MHz (1H) and 100 MHz (13C), respectively. Chemical shifts are reported in δ units and referenced to the solvent, that is, 7.24 (1H) and 77.0 (13C) for CDCl3. Multiplicities are indicated as br (broadened), s (singlet), d (doublet), t (triplet), or m (multiplet). Coupling constants (J) are reported in Hertz (Hz).

High‐resolution mass spectra (HRMS) were recorded on a JEOL T100LP mass spectrometer (Akishima, Tokyo, Japan) under fast atom bombardment (FAB) conditions using m‐nitrobenzyl alcohol as a matrix. IR spectra were recorded on a Spectrum One spectrometer (Perkin Elmer, Waltham, MA, USA).

2.2

Preparation of caged DAPTAD

4‐(4′‐Dimethylaminophenyl)‐1,2,4‐triazolidine‐3,5‐dione10 (0.5 g, 2.27 mmol), iodosylbenzene (0.5 g, 2.27 mmol), anhydrous magnesium sulfate (2 g), and 9‐phenylanthracene or 1,4‐diphenyl‐1,3‐butadiene (1 eq) were added to a nitrogen‐purged ethyl acetate solution (Figure 2). The resultant reaction mixture was stirred at room temperature in the dark until the solution turned dark red. After 4 h, the mixture was transferred into a separation funnel, washed with 5% sodium hydrogen carbonate (80 mL), and again washed with water (80 mL × 2) and brine.

The organic layer was dried over anhydrous magnesium sulfate, filtrated, and concentrated under reduced pressure. Purification by silica gel chromatography (hexane/ethyl acetate [7:3, v/v]) produced the caged DAPTAD as white crystals. The yields were 52% for the 9‐phenylanthracene adduct (DAP‐PA) and 61% for the 1,4‐diphenyl‐1,3‐butadiene adduct (2‐(4‐(dimethylamino)phenyl)‐5,8‐diphenyl‐5,8‐dihydro‐1H‐[1,2,4]triazolo[1,2‐a]pyridazine‐1,3(2H)‐dione, DAP‐DP).

Figure 2

Preparation of caged 4‐(4′‐dimethylaminophenyl)‐1,2,4‐triazoline‐3,5‐dione (DAPTAD)

Figure image at the original source: open the original paper. This file is not included in this text import.
2.3

Physical properties of DAP‐PA

1H‐NMR (CDCl3) δ 7.85 (d, J = 7.6 Hz, 2H), 7.59 to 7.49 (m, 5H), 7.31 (td, J = 7.6, 1.2 Hz, 2H), 7.22 (td, J = 7.6, 1.2 Hz, 2H), 7.03 (d, J = 7.6 Hz, 2H), 6.78 (ddd, J = 9.0, 3.2, 2.4 Hz, 2H), 6.56 (ddd, J = 9.0, 3.2, 2.4 Hz, 2H), 6.40 (s, 4H), 2.87 (s, 6H); 13C‐NMR (CDCl3) δ 158.2, 157.3, 150.3, 139.3, 132.5, 129.8, 128.8, 128.1, 128.0, 127.8, 126.6, 124.5, 123.9, 119.4, 112.2, 72.6, 62.6, 40.5; IR (KBr, cm−1) 3062, 1774, 1714, 1613, 1526, 1460, 1448, 1417, 1361, 1248, 1230, 1181, 1158, 1039, 1004, 946, 846, 805, 784, 764, 753, 702, 679, 634, 541; HRMS (FAB) calculated for C30H25N4O2 [(M + H)+] 473.19775, found 473.19683.

2.4

Physical properties of DAP‐DP

1H‐NMR (CDCl3) δ 7.52 (brd, J = 8.4 Hz, 4H), 7.42 to 7.32 (m, 6H), 7.18 (ddd, J = 9.2, 3.2, 2.4 Hz, 2H), 6.63 (ddd, J = 9.2, 3.2, 2.4 Hz, 2H), 5.99 (d, J = 1.2 Hz, 2H), 5.53 (d, J = 1.2 Hz, 2H), 2.89 (s, 6H); 13C‐NMR (CDCl3) δ 152.6, 137.4, 128.8, 128.6, 127.9, 126.4, 125.4, 112.3, 58.3, 40.5; IR (KBr, cm−1) 3031, 2941, 2802, 1771, 1701, 1614, 1523, 1493, 1447, 1420, 1352, 1289, 1193, 1158, 1143, 1063, 946, 878, 846, 819, 753, 698, 610, 588, 517; HRMS (FAB) calculated for C26H25N4O2 [(M + H)+] 425.19775, found 425.18956.

2.5

Analytical high‐performance liquid chromatography (HPLC)

The chromatographic analysis of the RDA reaction was performed using an Alliance HPLC system equipped with a model 2489 UV: Vis detector (Waters, Milford, MA, USA). Chromatography was performed using an Inertsil ODS‐3 column (4.6 mm I.D. × 250 mm (5 μm; GL Sciences, Tokyo, Japan) with a binary gradient system with water (A) and acetonitrile (B) and a flow rate of 1.0 mL/min. The detection wavelength was 210 nm, and the elution program was as follows: 0 → 10 min, 50% B; 10 → 20 min, 50 → 5% B; 20 → 50 min, 5% B; 50 → 55 min, 50% B; 55 → 60 min, 50% B.

2.6

Kinetic analysis of the RDA reaction

The rate constant k 1 was determined using the following equation describing the irreversible diene tag, 1,4‐diphenyl‐1,3‐buthadiene (Figures 3 and 4).

dx/dt=k1aNot reportedx.
lna/aNot reportedx=k1t.
Figure 3

Thermal retro‐Diels‐Alder (RDA) reaction of the caged DAPTAD

Figure image at the original source: open the original paper. This file is not included in this text import.
Figure 4

Kinetic analysis of the RDA reaction

Figure image at the original source: open the original paper. This file is not included in this text import.
2.7

Materials for LC/MS/MS

The JeoQuant kit for LC/MS/MS analysis of vitamin D metabolites including calibrators (25(OH)D3, 25(OH)D2, 3‐epi‐25(OH)D3, and 24,25(OH)2D3); internal standards (25(OH)D3‐[23,24,25,26,27‐13C5], 25(OH)D2‐[25,26,27‐13C3], 3‐epi‐25(OH)D3‐[23,24,25,26,27‐13C5], and 24,25(OH)2D3‐[26,26,26,27,27,27‐2H6]); quality controls; and the derivatization reagent (DAP‐PA ethyl acetate solution [0.5 mg/mL]) were obtained from JEOL (Akishima, Tokyo, Japan; https://www.jeol.co.jp/en/support/support_system/contact_jeoquantkit.html).

The calibrator concentrations for 25(OH)D3, 25(OH)D2, 3‐epi‐25(OH)D3, and 24,25(OH)2D3 were as follows: 0.873, 0.0920, 0.0940, and 0.0960 ng/mL for calibrator level 1; 8.80, 0.924, 0.938, and 0.962 ng/mL for calibrator level 2; 44.0, 4.62, 4.69, and 4.81 ng/mL for calibrator level 3; and 88.0, 9.23, 9.37, and 9.61 ng/mL for calibrator level 4. These concentrations were determined by quantitative NMR measurements.16 Human Serum Standard Reference Material (SRM972a) was obtained from the National Institute of Standards and Technology (NIST, Gaithersburg, MD, USA).

LC/MS‐grade acetonitrile and formic acid were purchased from Wako Pure Chemical Industries (Osaka, Japan). HPLC‐grade distilled water was obtained from Nacalai Tesque (Kyoto, Japan).

2.8

DAPTAD derivatization

DAP‐PA solution (100 μL) was added to the dried samples, and the resultant mixture was heated at 80°C for 15 min. Ethanol (20 μL) was added to the mixture to terminate the reaction, and the solvent was removed by centrifuged evaporation. The residue was dissolved in 50 μL of 30% aqueous acetonitrile for LC/MS/MS analyses.

2.9

Extraction of VD metabolites from SRM972a level 2 serum

SRM972a level 2 serum (50 μL) and internal standards (250 μL) were mixed and vortexed for 1 min. Each sample was loaded into a supported liquid extraction column (ISOLUTE® SLE+ 400 μL sample volume, Biotage, Uppsala, Sweden) and eluted three times with 600 μL ethyl acetate/hexane (1:1, v/v) using a PRESSURE+48 positive pressure manifold (Biotage). The combined eluents were evaporated to dryness using a centrifuged evaporator. DAPTAD derivatization of the obtained samples was carried out as described above.

2.10

LC/MS/MS analyses

LC/MS/MS analyses were performed using an QTRAP4500® triple quadruple mass spectrometer (AB SCIEX, Framingham, MA, USA) equipped with a model 1290 Infinity liquid chromatography system (Agilent Technologies, Santa Clara, CA, USA). Chromatography was performed using a binary gradient system with 0.1% formic acid (A) and 0.1% formic acid in acetonitrile (B) or methanol (C). Samples were dissolved in 50 μL of 30% aqueous acetonitrile and loaded into a CAPCELL CORE C18 (2.7 μm) 2.1 mm I.D. × 100 mm column (OSAKA SODA, Osaka, Japan) equilibrated with 0.1% formic acid 30% acetonitrile with a flow rate of 0.3 mL/min.

The injection volume was 20 μL. The elution program was as follows: 0.01 → 0.5 min, 30 → 58% B; 0.5 → 7.0 min, 58% B; 7.0 → 7.01 min, 58 → 90% B; 7.01 → 8.0 min, 90% B; 8.0 → 8.01 min, 90 → 30% B; 8.01 → 9.0 min, 30% B. For analyses of non‐derivatized VD metabolites, an InertSustain PFP HP (3 μm) 2.1 mm I.D. × 150 mm column (GL Sciences, Tokyo, Japan) was used. The flow rate was 0.4 mL/min, and the elution program was as follows: 0.01 → 0.5 min, 50 → 67% C; 0.5 → 9.0 min, 67% C; 9.0 → 9.01 min, 67 → 90% C; 9.01 → 11.0 min, 90% C; 11.0 → 11.01 min, 90 → 50% C; 11.01 → 13.0 min, 50% C.

Ionization was done with the positive ion mode, and selected reaction monitoring (SRM) was used for quantification. The transitions (m/z) and collision energies (CE) for the VD metabolites are summarized in Table 1. Operation and quantification analyses were done using Analyst® (version 1.7) and SCIEX OS software (AB SCIEX), respectively. The limit of detection (LOD) was determined from duplicate measurements of the authentic VD metabolite solution diluted with water as follows: 1:1 (not diluted), 1:8, 1:16, 1:32, 1:64, 1:128, 1:200, 1:256, 1:400, and 1:800.

The LODs were defined as the concentration of VD metabolites per injection giving a signal‐to‐noise ratio (S/N) of 10, which was manually calculated as the peak height divided by the noise level around the peak. The lower limit of quantification (LLOQ) was determined from three replicate measurements of SRM972a level 2 serum diluted with water as follows: 1:1 (not diluted), 1:2, 1:4, 1:8, 1:10, 1:16, 1:20, 1:32, 1:40, 1:64, 1:80, 1:160, 1:320, and 1:640. The LLOQs were set to the minimum level at which dilution linearity was confirmed and the coefficient of the variance was at most 15% and given by the concentration of VD metabolites per injection giving the S/N of 15.

Table 1

Tandem mass spectrometry parameters of vitamin D (VD) metabolites with and without 4‐(4′‐dimethylaminophenyl)‐1,2,4‐triazoline‐3,5‐dione (DAPTAD) derivatization

With derivatizationWithout derivatization
m/z CE m/z CE
25(OH)D3 and 3‐epi‐25(OH)D3 619.3 > 341.135401.2 > 91.089
25(OH)D3Not reported13C5 and 3‐epi‐25(OH)D3Not reported13C5 624.5 > 341.135
25(OH)D2 631.3 > 341.133417.1 > 105.165
25(OH)D2‐13C3 634.3 > 341.233
24,25(OH)2D3 635.3 > 341.137417.1 > 105.165
24,25(OH)2D3‐d 6 641.5 > 341.137

CE, collision energy.

3

RESULTS AND DISCUSSION

3.1

Solution stability of DAPTAD and DAP‐PA

Although TAD is one of the most reactive dienophiles and provides an excellent derivatization tag, its solution instability has been reported.17, 18, 19, 20 In nucleophilic solvent systems (alcohols or water), it undergoes a nucleophilic attack of its oxygen functional groups or a loss of nitrogen‐yielding dimeric compounds. We first examined the solution stability of DAPTAD, which was synthesized according to the published protocol,10 using NMR. The amount of residual DAPTAD was estimated by the integration of aromatic proton peaks (Figures 5 and S1, supporting information).

As expected, a time‐dependent decrease in the proton signals was observed in ethyl acetate, which is a common solvent for DAPTAD derivatization.10 The addition of molecular sieves 4A at 4°C increased the solution stability of DAPTAD, which strongly suggested that a nucleophilic attack by residual moisture occurred in the non‐caged TAD. On the other hand, the solution stability of DAP‐PA in ethyl acetate dramatically improved (Figure 6) in comparison with that of the non‐caged TAD, which indicated that a DA‐type protection (Figure 3) of the dienophile, TAD, was effective.

Figure 5

Solution stability of DAPTAD in ethyl acetate‐d 8 with (●: 4°C; ▲: 25°C) and without (■: 4°C; ◆: 25°C) molecular sieves 4A monitored using NMR spectroscopy [Color figure can be viewed at http://wileyonlinelibrary.com]

Figure image at the original source: open the original paper. This file is not included in this text import.
Figure 6

Solution stability of DAP‐PA monitored by HPLC.: 22.5°C (●), 6.8°C (▲), 25°C (■), 40°C (◆) [Color figure can be viewed at http://wileyonlinelibrary.com]

Figure image at the original source: open the original paper. This file is not included in this text import.
3.2

RDA reaction of caged DAPTAD

The RDA reaction is a reversible reaction, which can be controlled by thermal regulation (Figure 3).21, 22 This dynamic, reversible covalent bond formation and cleavage makes it possible to consider thermal protection and deprotection. The thermal RDA reaction enabling the release of DAPTAD was examined using analytical HPLC. DAPTAD itself was difficult to detect using reversed‐phase HPLC due to its instability in aqueous solvents, and we thus monitored the presence of 1,4‐diphenyl‐1,3‐butadiene and 9‐phenylanthracene at 70°C in ethyl acetate, which showed that the reaction with 1,4‐diphenyl‐1,3‐butadiene was irreversible (Figure 3).

On the other hand, the release of 9‐phenylanthracene was observed using the irreversible diene tag, 1,4‐diphenyl‐1,3‐buthadiene (Figures 4 and S8, supporting information). The release rate of 9‐phenylanthracene from DAP‐PA in ethyl acetate was temperature‐dependent (Table 2).21, 22 The reaction temperature (Table S9, supporting information), time (Table S10, supporting information), solvent (Table S2, supporting information), and concentration (Figure S11, supporting information) were also investigated using LC/MS/MS. The reaction was saturated in about 15 min. Although the reaction with aromatic solvents (toluene, anisole, and o‐dichlorobenzene) gave better rate constants than that with ethyl acetate (Table S2, supporting information), the peak area in the SRM chromatogram of derivatized VD metabolites produced in ethyl acetate was larger than that produced in toluene (Figure S11, supporting information).

Considering their boiling points (indicating the easiness to remove), we concluded that ethyl acetate at 80°C was the best reaction condition.

Table 2

Release rate of 9‐phenylanthracene from DAP‐PA in ethyl acetate

Reaction temperature (°C)Rate constant k 1 (h−1)
500.07
600.18
701.01
77a 2.50
a

Boiling point of ethyl acetate.

3.3

LC/MS/MS analyses of VDs without serum

Four VD metabolites with and without DAPTAD derivatization in the absence of serum were detected using the previously reported procedure.12 Their retention time (t R), LOD values, and sensitivity increase are summarized in Table 3.

Table 3

LODs for VD metabolites with and without DAPTAD derivatization in the absence of serum

With derivatizationWithout derivatization
t R a (min)LOD (ng/mL) t R a (min)LOD (ng/mL)Sensitivity increase
25(OH)D3 5.590.0556.971.425
25(OH)D2 6.700.0367.604.6128
3‐epi‐25(OH)D3 5.270.0377.490.5916
24,25(OH) 2D3 2.970.0374.260.308

LOD, limit of detection.

a

Derivatized and non‐derivatized VD metabolites were analyzed using CAPCELL CORE C18 and InertSustain PFP HP columns, respectively.

3.4

LC/MS/MS analyses of VDs in SRM972a level 2 serum

LLOQs of four VD metabolites in SRM972a level 2 serum with DAPTAD derivatization are summarized in Table 4. Their SRM chromatograms are shown in Figure 7. In our study 1α, 25‐dihydroxyvitamin D3 (1,25(OH)2D3) could not be detected quantitatively due to its extremely low concentration and the difficulty in chromatographic separation of 1,25(OH)2D3 and other dihydroxylated VD metabolites such as 4β, 25‐dihydroxyvitamin D.23 This problem could be solved by combining our present protocol with immunoaffinity extraction.23

Table 4

LLOQs for VD metabolites with DAPTAD derivatization in SRM972a level 2 serum

LLOQ (ng/mL)
25(OH)D3 0.12
25(OH)D2 0.045
3‐epi‐25(OH)D3 0.065
24,25(OH)2D3 0.072

LLOQ, lower limit of quantification.

Figure 7

Selected reaction monitoring chromatograms of DAPTAD‐derivatized VDs in SRM972a level 2 serum

Figure image at the original source: open the original paper. This file is not included in this text import.
4

CONCLUSIONS

We screened several diene groups to develop the caged Cookson‐type reagent, DAP‐PA, which was stable enough for mid‐ to long‐term storage in solution. Highly stable reagents are essential for data reproducibility in clinical laboratories. The stability of the reagents in a solution is guaranteed by the production of pure products, which is generally achieved by crystallization, and the caged DAPTAD is easy to crystallize, which is a strong advantage in terms of quality control. In addition, from a practical viewpoint, the caged DAPTAD is available in large quantities, and thus market supply is stable and ample.

This advantage will contribute to the field of VD detection and quantification in clinical laboratories, and thus to the broader use of clinical mass spectrometry.24

Supporting information

Figure S1. 1H‐NMR spectra of the aromatic region of DAPTAD in ethyl acetate‐d 8. DAPTAD signals assigned to aromatic protons are indicated by arrows.

Figure S2. 1H‐NMR spectrum of DAP‐PA in CDCl3.

Figure S3. 13C‐NMR spectrum of DAP‐PA in CDCl3.

Figure S4. IR spectrum of DAP‐PA.

Figure S5. 1H‐NMR spectrum of DAP‐DP in CDCl3.

Figure S6. 13C‐NMR spectrum of DAP‐DP in CDCl3.

Figure S7. IR spectrum of DAP‐DP.

Figure S8. HPLC chromatograms of the retro‐DA reaction products.

Figure S9. Peak area of DAPTAD‐derivatized VD metabolites on SRM chromatograms. The reaction condition was 0.25 mg/mL in ethyl acetate for 60 min (n=2). Data were obtained using a Waters Xevo TQ‐XS mass spectrometer.

Figure S10. Peak area of DAPTAD‐derivatized VD metabolites on SRM chromatograms. The reaction condition was 0.25 mg/mL in ethyl acetate at 80°C (n=2). Data were obtained using a Waters Xevo TQ‐XS mass spectrometer.

Figure S11. Peak area of DAPTAD‐derivatized VDs on SRM chromatograms. The reaction was performed at 80°C for 15 min (n=2). Data were obtained by using a Waters Xevo TQ‐XS mass spectrometer.

Table S1. Kinetics of anthracene analogues in ethyl acetate at 70°C.

Table S2. Solvent effect for the retro‐DA reaction of DAP‐PA at 70°C.

Click here for additional data file.

Supplement file at the original source: open the original paper. This file is not included in this text import.

ACKNOWLEDGEMENTS

The authors are very grateful to Mr. Kiyotaka Fujino of JEOL for organizing this project. Thanks are due to Mr. Kazunori Ozaki at JEOL for help in the measurement of HRMS. The authors would also like to thank Mr. Shin Watanabe of TOKUYAMA and Mr. Kentaro Abe of JEOL for significant administrative assistance and Ms. Patricia McGahan for English language editing.

REFERENCES

1 Bikle DD . Vitamin D metabolism, mechanism of action, and clinical applications . Chem Biol . 2014 ;21 (3 ):319 ‐329 . 24529992 10.1016/j.chembiol.2013.12.016 PMC3968073
2 Holick MF . Vitamin D deficiency . N Engl J Med . 2007 ;357 (3 ):266 ‐281 . 17634462 10.1056/NEJMra070553
3 Lensmeyer G , Poquette M , Wiebe D , Binkley N . The C‐3 epimer of 25‐hydroxyvitamin D3 is present in adult serum . J Clin Endocrinol Metab . 2012 ;97 (1 ):163 ‐168 . 22013102 10.1210/jc.2011-0584
4 Dauber A , Nguyen TT , Sochett E , et al. Genetic defect in CYP24A1, the vitamin D 24‐hydroxylase gene, in a patient with severe infantile hypercalcemia . J Clin Endocrinol Metab . 2012 ;97 (2 ):E268 ‐E274 . 22112808 10.1210/jc.2011-1972 PMC3275367
5 Müller MJ , Volmer DA . Mass spectrometric profiling of vitamin D metabolites beyond 25‐hydroxyvitamin D . Clin Chem . 2015 ;61 (8 ):1033 ‐1048 . 26130585 10.1373/clinchem.2015.241430
6 Higashi T , Shimada K . Application of Cookson‐type reagents for biomedical HPLC and LC/MS analyses: A brief overview . Biomed Chromatogr . 2017 ;31 (1 ):1 ‐10 . 10.1002/bmc.3808 27511712
7 Wilson SR , Lu Q , Tulchinsky ML , Wu Y . Analysis of vitamin D and its metabolites: Derivatization and detection by electrospray ionization mass spectrometry . Chem Commun . 1993 ;(8 ):664 ‐665 .
8 Higashi T , Shimada K . Derivatization of neutral steroids to enhance their detection characteristics in liquid chromatography: mass spectrometry . Anal Bioanal Chem . 2004 ;378 (4 ):875 ‐882 . 14598004 10.1007/s00216-003-2252-z
9 Cookson RC , Gilani SSH , Stevens IDR . 4‐Phenyl‐1,2,4‐triazolin‐3,5‐dione a powerful dienophile . Tetrahedron Lett . 1962 ;3 (14 ):615 ‐618 .
10 Ogawa S , Ooki S , Morohashi M , Yamagata K , Higashi T . A novel Cookson‐type reagent for enhancing sensitivity and specificity in assessment of infant vitamin D status using liquid chromatography/tandem mass spectrometry . Rapid Commun Mass Spectrom . 2013 ;27 (21 ):2453 ‐2460 . 24097402 10.1002/rcm.6708
11 Ogawa S , Kittaka H , Shinoda K , Ooki S , Nakata A , Higashi T . Comparative evaluation of new Cookson‐type reagents for LC/ESI‐MS/MS assay of 25‐hydroxyvitamin D3 in neonatal blood samples . Biomed Chromatogr . 2016 ;30 (6 ):938 ‐945 . 26451531 10.1002/bmc.3633
12 Satoh M , Ishige T , Ogawa S , et al. Development and validation of the simultaneous measurement of four vitamin D metabolites in serum by LC: MS/MS for clinical laboratory applications . Anal Bioanal Chem . 2016 ;408 (27 ):7617 ‐7627 . 27526091 10.1007/s00216-016-9821-4
13 Kim JH , Woenker T , Adamec J , Regnier FE . Simple, miniaturized blood plasma extraction method . Anal Chem . 2013 ;85 (23 ):11501 ‐11508 . 24156552 10.1021/ac402735y
14 Hedman CJ , Wiebe DA , Dey S , Plath J , Kemnitz JW , Ziegler TE . Development of a sensitive LC/MS/MS method for vitamin D metabolites: 1,25 dihydroxyvitamin D2&3 measurement using a novel derivatization agent . J Chromatogr B . 2014 ;953 to 954 :62 ‐67 . 10.1016/j.jchromb.2014.01.045 PMC4050665 24576767
15 Wan D , Yang J , Barnych B , et al. A new sensitive LC/MS/MS analysis of vitamin D metabolites using a click derivatization reagent, 2‐nitrosopyridine . J Lipid Res . 2017 ;58 (4 ):798 ‐808 . 28148721 10.1194/jlr.D073536 PMC5392736
16 Yamazaki T , Ohtsuki T , Miura T , et al. Study of sample preparation method using internal standard solution to accurate quantitative analysis with 1H NMR spectroscopy . BUNSEKI KAGAKU . 2014 ;63 (4 ):323 ‐329 .
17 Pirkle WH , Stickler JC . The reaction of 1,2,4‐triazoline‐3,5‐diones with mono‐olefins . Chem Commun . 1967 ;(15 ):760 ‐761 .
18 Dao LH , Mackay D . Duality of pathways in the reaction of N‐phenyltriazolinedione with alcohols . Chem Commun . 1976 ;(9 ):326 ‐327 .
19 Izydore RA , Johnson HE , Horton RT . Decomposition reactions of a cis‐diacyl diimide. 4‐phenyl‐1,2,4‐triazoline‐3,5‐dione . J Org Chem . 1985 ;50 (23 ):4589 ‐4595 .
20 Borhani DW , Greene FD . Triazolinediones. Conversion to deaza dimers by electron‐transfer catalysis. A possible radical anion Diels‐Alder reaction . J Org Chem . 1986 ;51 (9 ):1563 ‐1570 .
21 Reutenauer P , Boul PJ , Lehn J‐M . Dynamic Diels: Alder reactions of 9,10‐dimethylanthracene: Reversible adduct formation, dynamic exchange processes and thermal fluorescence modulation . Eur J Org Chem . 2009 ;(11 ):1691Not reported1697 .
22 Kiselev VD , Kornilov DA , Kashaeva EA , et al. Features of the Diels: Alder reaction between 9,10: diphenylanthracene and 4‐phenyl‐1,2,4‐triazoline‐3,5‐dione . Russ J Phys Chem A . 2014 ;88 (12 ):2073 ‐2080 .
23 Ishige T , Satoh M , Ogawa S , et al. Improved sensitivity of serum/plasma 1α,25‐dihydroxyvitamin D quantification by DAPTAD derivatization . Clin Chim Acta . 2017 ;473 :173 ‐179 . 28864231 10.1016/j.cca.2017.08.033
24 Satoh M , Nomura F . Applications of mass spectrometry in clinical chemistry . Med Mass Spectrom . 2019 ;3 (1 ):2 ‐10 .
Publication and source details

Original title: A novel caged Cookson‐type reagent toward a practical vitamin D derivatization method for mass spectrometric analyses

Masahiko Seki; Makoto Sato; Masaki Takiwaki; Koji Takahashi; Yoshikuni Kikutani; Mamoru Satoh; Fumio Nomura; Yutaka Kuroda; Seketsu Fukuzawa

Rapid Communications in Mass Spectrometry · 2020

* Correspondence
S. Fukuzawa, Department of Biotechnology and Life Science, Faculty of Technology, Tokyo University of Agriculture and Technology, 2‐24‐16 Naka‐cho, Koganei. Tokyo 184‐8588, Japan and Open Innovation Promotion Department, Management Strategy Planning Division, JEOL Ltd., 3‐1‐2 Musashino, Akishima, Tokyo 196‐8558, Japan.
Email: s-fukuzawa@m2.tuat.ac.jp; sfukuzaw@jeol.co.jp
© 2019 The Authors. Rapid Communications in Mass Spectrometry published by John Wiley & Sons Ltdhttps://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.

Repository JATS snapshot; version as supplied

Source retrieved: 2026-11-11T17:40:24.525047+00:00

DOI: 10.1002/rcm.8648 · PMC7064983