Primary relevance to vitamin D Vitamin D is a stated subject of this paper.
Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.
Why this paper is included
Supporting source evidence:
Specifically, the different reagents were compared for LC: MS/MS analysis of five different vitamin D3 metabolites.
Source: Results and discussion. View original paper
Relevance classification does not establish study quality, causation or editorial approval.
Study design Study design awaiting verification.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.
Meta-analysis unclear · Blinding unclear / not reported · Research setting awaiting verification
How this paper was classified
Automatic source-based classification; awaiting editorial verification. This is not a quality score.
What the study types mean
- Systematic review
- Uses explicit methods to identify, assess and summarise research on a defined question.
- Scoping review
- Maps the extent and characteristics of research on a topic.
- Narrative review
- Discusses existing research; systematic-review methods have not been established by this classification.
- Review / evidence synthesis
- Reviews existing research; the exact review methods need further assessment.
- Randomised controlled trial
- Assigns participants or groups to comparison interventions by chance.
- Non-randomised intervention study
- Examines an intervention without random allocation.
- Cohort study
- Examines exposures and outcomes over time within a defined group.
- Case-control study
- Compares people with an outcome against people without it, examining exposures.
- Cross-sectional study
- Examines a population at a particular point in time.
- Observational study
- Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
- Case report
- Describes an individual case.
- Case series
- Describes a group of individual cases.
- Secondary analysis
- Analyses existing study data; this paper is not automatically another independent trial.
- Laboratory study
- Investigates biological processes in a laboratory setting.
- Qualitative study
- Examines experiences or meanings using qualitative methods.
- Genetic instrumental-variable study
- Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
- Study protocol
- Describes planned methods and is not evidence that the planned study has reported results.
- Multiple reported designs
- More than one design is explicitly reported; examine the supporting methods.
- Study design awaiting verification
- The available source does not establish a sufficiently clear study design.
Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.
Abstracts
Comparing derivatization reagents for quantitative LC-MS/MS analysis of a variety of vitamin D metabolites
Study design awaiting verification · Analytical and Bioanalytical Chemistry · 2023
Original publication title
Comparing derivatization reagents for quantitative LC: MS/MS analysis of a variety of vitamin D metabolites
© The Author(s) 2023
Original publication · Publisher record · CC BY 4.0
Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.
At a glance
What does the authors’ abstract report?
The present study systematically compares the sensitivity and selectivity of the analysis of multiple vitamin D metabolites after chemical derivatization using different reagents for liquid chromatography-tandem mass spectrometry (LC: MS/MS). Generally, chemical derivatization is applied to vitamin D metabolites to increase the ionization efficiency, which is particularly important for very low abundant metabolites. Derivatization can also improve the selectivity of the LC separation. A wide variety of derivatization reagents has been reported in recent years, but information on their relative performance and applicability to different vitamin D metabolites is, unfortunately, not available in the literature.
To fill this gap, we investigated vitamin D3, 3β-25-hydroxyvitamin D3 (3β-25(OH)D3), 3α-25-hydroxyvitamin D3 (3α-25(OH)D3), 1,25-dihydroxyvitamin D3 (1,25(OH)2D3), and 24,25-dihydroxyvitamin D3 (24,25(OH)2D3) and compared response factors and selectivity after derivatizing with several important reagents, including four dienophile reagents (4-phenyl-1,2,4-triazoline-3,5-dione (PTAD), 4-[2-(6,7-dimethoxy-4-methyl-3-oxo-3,4-dihydroquinoxalinyl)ethyl]-1,2,4-triazoline-3,5-dione (DMEQ-TAD), Amplifex, 2-nitrosopyridine (PyrNO)) as well as two reagents targeting hydroxyl groups: isonicotinoyl chloride (INC) and 2-fluoro-1-methylpyridinium-p-toluenesulfonate (FMP-TS). In addition, a combination of dienophiles and hydroxyl group reagents was examined.
For LC separations, reversed-phase C-18 and mixed-mode pentafluorophenyl HPLC columns using different compositions of the mobile phase were compared. With respect to detection sensitivity, the optimum derivatization reagent for the profiling of multiple metabolites was Amplifex. Nevertheless, FMP-TS, INC, PTAD, or PTAD combined with an acetylation reaction showed very good performance for selected metabolites. These reagent combinations provided signal enhancements on the order of 3: to 295-fold depending on the compound. Chromatographic separation of the dihydroxylated vitamin D3 species was readily achieved using any of the derivatization reactions, while for 25(OH)D3 epimers, only PyrNO, FMP, INC, and PTAD combined with acetylation enabled complete separation.
In conclusion, we believe this study can serve as a useful reference for vitamin D laboratories, to help analytical and clinical scientists decide which derivatization reagent to choose for their application.
Supplementary Information
The online version contains supplementary material available at 10.1007/s00216-023-04753-0.
Authors’ abstract
The present study systematically compares the sensitivity and selectivity of the analysis of multiple vitamin D metabolites after chemical derivatization using different reagents for liquid chromatography-tandem mass spectrometry (LC: MS/MS). Generally, chemical derivatization is applied to vitamin D metabolites to increase the ionization efficiency, which is particularly important for very low abundant metabolites. Derivatization can also improve the selectivity of the LC separation. A wide variety of derivatization reagents has been reported in recent years, but information on their relative performance and applicability to different vitamin D metabolites is, unfortunately, not available in the literature.
To fill this gap, we investigated vitamin D3, 3β-25-hydroxyvitamin D3 (3β-25(OH)D3), 3α-25-hydroxyvitamin D3 (3α-25(OH)D3), 1,25-dihydroxyvitamin D3 (1,25(OH)2D3), and 24,25-dihydroxyvitamin D3 (24,25(OH)2D3) and compared response factors and selectivity after derivatizing with several important reagents, including four dienophile reagents (4-phenyl-1,2,4-triazoline-3,5-dione (PTAD), 4-[2-(6,7-dimethoxy-4-methyl-3-oxo-3,4-dihydroquinoxalinyl)ethyl]-1,2,4-triazoline-3,5-dione (DMEQ-TAD), Amplifex, 2-nitrosopyridine (PyrNO)) as well as two reagents targeting hydroxyl groups: isonicotinoyl chloride (INC) and 2-fluoro-1-methylpyridinium-p-toluenesulfonate (FMP-TS). In addition, a combination of dienophiles and hydroxyl group reagents was examined.
For LC separations, reversed-phase C-18 and mixed-mode pentafluorophenyl HPLC columns using different compositions of the mobile phase were compared. With respect to detection sensitivity, the optimum derivatization reagent for the profiling of multiple metabolites was Amplifex. Nevertheless, FMP-TS, INC, PTAD, or PTAD combined with an acetylation reaction showed very good performance for selected metabolites. These reagent combinations provided signal enhancements on the order of 3: to 295-fold depending on the compound. Chromatographic separation of the dihydroxylated vitamin D3 species was readily achieved using any of the derivatization reactions, while for 25(OH)D3 epimers, only PyrNO, FMP, INC, and PTAD combined with acetylation enabled complete separation.
In conclusion, we believe this study can serve as a useful reference for vitamin D laboratories, to help analytical and clinical scientists decide which derivatization reagent to choose for their application.
Supplementary Information
The online version contains supplementary material available at 10.1007/s00216-023-04753-0.
Publication and source details
Original title: Comparing derivatization reagents for quantitative LC: MS/MS analysis of a variety of vitamin D metabolites
Anastasia Alexandridou; Pascal Schorr; Dietrich A. Volmer
Analytical and Bioanalytical Chemistry · 2023
© The Author(s) 2023https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/.http://dx.doi.org/10.13039/501100001659Deutsche ForschungsgemeinschaftVO 1355/5-2Alexandridou Anastasia Humboldt-Universität zu Berlin (1034)Open Access funding enabled and organized by Projekt DEAL.
Repository JATS snapshot; version as supplied
Source retrieved: 2026-11-11T06:48:09.383059+00:00
DOI: 10.1007/s00216-023-04753-0 · PMC10352403