Secondary relevance to vitamin D This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.
This paper mainly addresses another topic and also reports a vitamin D analysis, result or scientific synthesis.
Why this paper is included
Supporting source evidence:
No difference in the content of 25(OH)D or 25(OH)D3 was found between venous serum and corrected capillary serum.
Source: Abstract. View original paper
Relevance classification does not establish study quality, causation or editorial approval.
Study design Study protocol.
Study protocol
Describes planned methods and is not evidence that the planned study has reported results.
Meta-analysis unclear · Blinding unclear / not reported · Research setting awaiting verification
How this paper was classified
Automatic source-based classification; awaiting editorial verification. This is not a quality score.
This study protocol was approved by the medical ethics committee of Shanghai Children's Medical Center affiliated with Shanghai Jiao Tong University School of Medicine, and all study participants provided written informed consent.
Source: Methods.
What the study types mean
- Systematic review
- Uses explicit methods to identify, assess and summarise research on a defined question.
- Scoping review
- Maps the extent and characteristics of research on a topic.
- Narrative review
- Discusses existing research; systematic-review methods have not been established by this classification.
- Review / evidence synthesis
- Reviews existing research; the exact review methods need further assessment.
- Randomised controlled trial
- Assigns participants or groups to comparison interventions by chance.
- Non-randomised intervention study
- Examines an intervention without random allocation.
- Cohort study
- Examines exposures and outcomes over time within a defined group.
- Case-control study
- Compares people with an outcome against people without it, examining exposures.
- Cross-sectional study
- Examines a population at a particular point in time.
- Observational study
- Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
- Case report
- Describes an individual case.
- Case series
- Describes a group of individual cases.
- Secondary analysis
- Analyses existing study data; this paper is not automatically another independent trial.
- Laboratory study
- Investigates biological processes in a laboratory setting.
- Qualitative study
- Examines experiences or meanings using qualitative methods.
- Genetic instrumental-variable study
- Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
- Study protocol
- Describes planned methods and is not evidence that the planned study has reported results.
- Multiple reported designs
- More than one design is explicitly reported; examine the supporting methods.
- Study design awaiting verification
- The available source does not establish a sufficiently clear study design.
Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.
Abstracts
Development of a sensitive HPLC‐MS/MS method for 25‐hydroxyvitamin D2 and D3 measurement in capillary blood
Study protocol · Journal of Clinical Laboratory Analysis · 2020
Original publication title
Development of a sensitive HPLC‐MS/MS method for 25‐hydroxyvitamin D2 and D3 measurement in capillary blood
© 2020 The Authors. Journal of Clinical Laboratory Analysis published by Wiley Periodicals LLC
Original publication · Publisher record · CC BY 4.0
Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.
At a glance
Abstract: What background does the paper provide?
Measurement of 25‐hydroxyvitamin D [25(OH)D)] levels is important. The current method requires a relatively large volume of serum. To minimize the amount of serum needed, we established a high‐performance liquid chromatography‐tandem mass spectrometry (HPLC‐MS/MS) method to measure 25(OH)D in capillary serum.
Source: BackgroundAbstract: What methods does the paper describe?
Venous blood and fingertip blood were collected from 90 participants. Volumes of 100 µL of venous serum and 20 µL of capillary serum were collected. The serum samples were pretreated by protein removal, extraction and concentration, and an HPLC‐MS/MS method based on chromatographic separation and multi reactive ion monitoring was conducted. The intra‐ and inter‐batch variation coefficients were less than 10% for both 25‐hydroxyvitamin D3[25(OH)D3] and 25‐hydroxyvitamin D2[25(OH)D2)]. For venous specimens, the accuracies were 3.87% and 4.91%, respectively.
For capillary specimens, the accuracies were 1.65% and 5.32%, respectively.
Source: MethodsAbstract: Results
The limit of detection (LOD) of 25(OH)D3 was 0.01 ng/mL, and the LOD of 25(OH)D2 was 0.05 ng/mL. The results showed that the mean concentration of 25(OH)D in venous blood was 22.56 ± 9.50 ng/mL, while the mean concentration of 25(OH)D in capillary blood was 18.14 ± 7.86 ng/mL. Furthermore, the adjusted capillary blood 25(OH)D level was 22.99 ± 10.24 ng/mL by the correction formula in our study. Similarly, the mean concentration of 25(OH)D3 in capillary blood was 17.98 ± 7.98 ng/mL.
The adjusted capillary blood 25(OH)D3 level was 22.85 ± 10.42 ng/mL. No difference in the content of 25(OH)D or 25(OH)D3 was found between venous serum and corrected capillary serum. The correlation coefficients between venous and corrected capillary concentrations of 25(OH)D and 25(OH)D3 were 0.7941 and 0.8103, respectively, and the areas under the receiver operating characteristic curve were 0.9367 and 0.9565, respectively.
Source: ResultsAbstract: Conclusions
This capillary blood method requires minimal sample preparation and is suitable for routine use in the 25(OH)D detection.
Source: ConclusionsAuthors’ abstract
Abstract
Background
Measurement of 25‐hydroxyvitamin D [25(OH)D)] levels is important. The current method requires a relatively large volume of serum. To minimize the amount of serum needed, we established a high‐performance liquid chromatography‐tandem mass spectrometry (HPLC‐MS/MS) method to measure 25(OH)D in capillary serum.
Methods
Venous blood and fingertip blood were collected from 90 participants. Volumes of 100 µL of venous serum and 20 µL of capillary serum were collected. The serum samples were pretreated by protein removal, extraction and concentration, and an HPLC‐MS/MS method based on chromatographic separation and multi reactive ion monitoring was conducted. The intra‐ and inter‐batch variation coefficients were less than 10% for both 25‐hydroxyvitamin D3[25(OH)D3] and 25‐hydroxyvitamin D2[25(OH)D2)]. For venous specimens, the accuracies were 3.87% and 4.91%, respectively.
For capillary specimens, the accuracies were 1.65% and 5.32%, respectively.
Results
The limit of detection (LOD) of 25(OH)D3 was 0.01 ng/mL, and the LOD of 25(OH)D2 was 0.05 ng/mL. The results showed that the mean concentration of 25(OH)D in venous blood was 22.56 ± 9.50 ng/mL, while the mean concentration of 25(OH)D in capillary blood was 18.14 ± 7.86 ng/mL. Furthermore, the adjusted capillary blood 25(OH)D level was 22.99 ± 10.24 ng/mL by the correction formula in our study. Similarly, the mean concentration of 25(OH)D3 in capillary blood was 17.98 ± 7.98 ng/mL.
The adjusted capillary blood 25(OH)D3 level was 22.85 ± 10.42 ng/mL. No difference in the content of 25(OH)D or 25(OH)D3 was found between venous serum and corrected capillary serum. The correlation coefficients between venous and corrected capillary concentrations of 25(OH)D and 25(OH)D3 were 0.7941 and 0.8103, respectively, and the areas under the receiver operating characteristic curve were 0.9367 and 0.9565, respectively.
Conclusions
This capillary blood method requires minimal sample preparation and is suitable for routine use in the 25(OH)D detection.
Publication and source details
Original title: Development of a sensitive HPLC‐MS/MS method for 25‐hydroxyvitamin D2 and D3 measurement in capillary blood
XianTing Jiao; Yichun Yuan; Xirui Wang; Juan Li; Bin Liu; Tao Yuan; XiaoDan Yu
Journal of Clinical Laboratory Analysis · 2020
* CorrespondenceXiaodan Yu, Department of Developmental and Behavioral Pediatrics, Pediatric Translation Medicine Institute, Shanghai Children’s Medical Center, Shanghai Jiao Tong University School of Medicine, 1678 Dongfang Road, Shanghai 200127, China.
Emails: xd_yu2003@126.com (or) yuxiaodan@scmc.com.cn
© 2020 The Authors. Journal of Clinical Laboratory Analysis published by Wiley Periodicals LLChttps://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.the Chinese National Natural Science Number81773411National Key Research Program of China2016YFC1305204Shanghai Pudong Health System Excellent Community Suitable Talent Cultivation ProgramPWRs2017‐35Shanghai Children's Health Services Capacity ProgramGDEK201708the Science and Technology Commission Project of Shanghai Pudong New AreaPKJ2017‐Y05Medical and Engineering Cooperation Project of Shanghai Jiao Tong UniversityYG2017ZD15Shanghai Jiao Tong University
Repository JATS snapshot; version as supplied
Source retrieved: 2026-11-11T16:37:21.160793+00:00
DOI: 10.1002/jcla.23451 · PMC7595913