Primary relevance to vitamin D Vitamin D is a stated subject of this paper.
Vitamin D is a stated subject of this paper; the supporting source evidence is shown below.
Why this paper is included
Supporting source evidence:
Cohen’s kappa (κ) for method agreement for vitamin D deficiency (tested cut-off values 20 ng/ml and 12 ng/ml), was κ = 0.291 (p < 0.001) and κ = 0.469 (p < 0.001), respectively.
Source: Abstract. View original paper
Relevance classification does not establish study quality, causation or editorial approval.
Study design Study design awaiting verification.
Study design awaiting verification
The available source does not establish a sufficiently clear study design.
Meta-analysis unclear · Blinding unclear / not reported · Human research reported
How this paper was classified
Automatic source-based classification; awaiting editorial verification. This is not a quality score.
Patients undergoing elective and acute procedures were included if patients were able to give informed consent preoperatively.
Source: Methods.
What the study types mean
- Systematic review
- Uses explicit methods to identify, assess and summarise research on a defined question.
- Scoping review
- Maps the extent and characteristics of research on a topic.
- Narrative review
- Discusses existing research; systematic-review methods have not been established by this classification.
- Review / evidence synthesis
- Reviews existing research; the exact review methods need further assessment.
- Randomised controlled trial
- Assigns participants or groups to comparison interventions by chance.
- Non-randomised intervention study
- Examines an intervention without random allocation.
- Cohort study
- Examines exposures and outcomes over time within a defined group.
- Case-control study
- Compares people with an outcome against people without it, examining exposures.
- Cross-sectional study
- Examines a population at a particular point in time.
- Observational study
- Observes exposures and outcomes without assigning the exposure; the subtype is not established here.
- Case report
- Describes an individual case.
- Case series
- Describes a group of individual cases.
- Secondary analysis
- Analyses existing study data; this paper is not automatically another independent trial.
- Laboratory study
- Investigates biological processes in a laboratory setting.
- Qualitative study
- Examines experiences or meanings using qualitative methods.
- Genetic instrumental-variable study
- Uses genetic variation as an instrument to investigate relationships; this is not a randomised treatment trial.
- Study protocol
- Describes planned methods and is not evidence that the planned study has reported results.
- Multiple reported designs
- More than one design is explicitly reported; examine the supporting methods.
- Study design awaiting verification
- The available source does not establish a sufficiently clear study design.
Meta-analysis combines numerical results from studies. Blinding describes who was unaware of treatment allocation. Neither is a separate quality grade. Study design, vitamin D relevance and document format are independent filters.
Abstracts
Vitamin D assessment in perioperative medicine and critical care
Study design awaiting verification · Wiener Klinische Wochenschrift · 2019
Original publication title
Vitamin D assessment in perioperative medicine and critical care
© The Author(s) 2019
Original publication · Publisher record · CC BY 4.0
Source wording retained. Formatting, section navigation and display-title punctuation adapted for this research record.
At a glance
Abstract: What background does the paper provide?
There is controversy about the impact of acute illness on vitamin D levels. This study was carried out to assess the influence of perioperative fluid loading on 25-hydroxy-vitamin D [25(OH)D] levels. The study evaluated the clinical utility of a commonly available chemiluminescence assay (ECLIA, IDS-iSYS) and liquid chromatography/mass spectrometry (LC-MS/MS) in the diagnosis of vitamin D deficiency in this setting.
Source: BackgroundAbstract: What methods does the paper describe?
In this prospective observational pilot study in adult patients undergoing cardiovascular surgery on cardiopulmonary bypass (CPB), blood samples drawn at preoperative baseline (t1), after weaning from CPB (t2), on intensive care unit (ICU) admission (t3) and on the first (t4) and second (t5) postoperative days were analyzed.
Source: MethodsAbstract: Results
A total of 26 patients (130 samples) were included in this study. Fluid loading by CPB led to a median reduction of 25(OH)D by −22.6% (range −54.5% to −19.5%) between t1 and t2. Cohen’s kappa (κ) for method agreement for vitamin D deficiency (tested cut-off values 20 ng/ml and 12 ng/ml), was κ = 0.291 (p < 0.001) and κ = 0.469 (p < 0.001), respectively. The mean difference between measurements by ECLIA and LC-MS/MS was 4.8 ng/ml (±5.7), Pearson’s r for correlation was 0.73 (p < 0.001).
The biologically inactive C3-epimer did not contribute to 25(OH)D levels assessed by LC-MS/MS.
Source: ResultsAbstract: Conclusion
The 25(OH)D measurements by chemiluminescence assays can noticeably deviate from those measured by LC-MS/MS, which can be considered the unequivocal gold standard. These assays may still be acceptably reliable in the screening for vitamin D deficiency, especially in the setting of low vitamin D levels. Stricter definitions, e.g. serum 25(OH)D levels lower than 12 ng/ml, may be used to diagnose deficiency with low false positive rate.
Source: ConclusionAuthors’ abstract
Summary
Background
There is controversy about the impact of acute illness on vitamin D levels. This study was carried out to assess the influence of perioperative fluid loading on 25-hydroxy-vitamin D [25(OH)D] levels. The study evaluated the clinical utility of a commonly available chemiluminescence assay (ECLIA, IDS-iSYS) and liquid chromatography/mass spectrometry (LC-MS/MS) in the diagnosis of vitamin D deficiency in this setting.
Methods
In this prospective observational pilot study in adult patients undergoing cardiovascular surgery on cardiopulmonary bypass (CPB), blood samples drawn at preoperative baseline (t1), after weaning from CPB (t2), on intensive care unit (ICU) admission (t3) and on the first (t4) and second (t5) postoperative days were analyzed.
Results
A total of 26 patients (130 samples) were included in this study. Fluid loading by CPB led to a median reduction of 25(OH)D by −22.6% (range −54.5% to −19.5%) between t1 and t2. Cohen’s kappa (κ) for method agreement for vitamin D deficiency (tested cut-off values 20 ng/ml and 12 ng/ml), was κ = 0.291 (p < 0.001) and κ = 0.469 (p < 0.001), respectively. The mean difference between measurements by ECLIA and LC-MS/MS was 4.8 ng/ml (±5.7), Pearson’s r for correlation was 0.73 (p < 0.001).
The biologically inactive C3-epimer did not contribute to 25(OH)D levels assessed by LC-MS/MS.
Conclusion
The 25(OH)D measurements by chemiluminescence assays can noticeably deviate from those measured by LC-MS/MS, which can be considered the unequivocal gold standard. These assays may still be acceptably reliable in the screening for vitamin D deficiency, especially in the setting of low vitamin D levels. Stricter definitions, e.g. serum 25(OH)D levels lower than 12 ng/ml, may be used to diagnose deficiency with low false positive rate.
Trial Registration
DRKS00009216, German Clinical Trials Registry (www.drks.de)
Publication and source details
Original title: Vitamin D assessment in perioperative medicine and critical care
Paul Zajic; Stefan Heschl; Michael Schörghuber; Petra Srekl-Filzmaier; Tatjana Stojakovic; Viktoria Weixler; Sieglinde Zelzer; Karin Amrein
Wiener Klinische Wochenschrift · 2019
© The Author(s) 2019https://creativecommons.org/licenses/by/4.0/Open Access This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made.Medical University of GrazOpen access funding provided by Medical University of Graz.
Repository JATS snapshot; version as supplied
Source retrieved: 2026-11-11T16:28:41.588515+00:00
DOI: 10.1007/s00508-019-01584-x · PMC7875852